RAID 1(+0): breaking mirrors and rebuilding drives



Similar documents
RAID 1(+0): breaking mirrors and rebuilding drives

HP Array Configuration Utility User Guide

HP Embedded SATA RAID Controller

HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers

RAID 5 rebuild performance in ProLiant

HP Smart Array B110i SATA RAID Controller User Guide

Using HP ProLiant Network Teaming Software with Microsoft Windows Server 2008 Hyper-V or with Microsoft Windows Server 2008 R2 Hyper-V

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

RAID 6 with HP Advanced Data Guarding technology:

Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers

This user guide describes features that are common to most models. Some features may not be available on your computer.

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

HP Embedded SATA RAID Controller

HP VMware ESXi 5.0 and Updates Getting Started Guide

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

HP Recommended SMART Array Rebuilding/Restoring Techniques

HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation

HP ProLiant Cluster for MSA1000 for Small Business Hardware Cabling Scheme Introduction Software and Hardware Requirements...

RocketRAID esata 3G HBA Series Bootable RAID. Installation Guide.

Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers

HP Smart Array P400 Controller User Guide

How to use Data Protector 6.0 or 6.10 with Exchange Recovery Storage Groups to restore a single mailbox

Instructions for installing Microsoft Windows Small Business Server 2003 R2 on HP ProLiant servers

QuickSpecs. HP Smart Array 5312 Controller. Overview

HP One-Button Disaster Recovery Solution for ProLiant Servers

Installing Microsoft Windows

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD A February 2007

RAID Technology Overview

This user guide describes features that are common to most models. Some features may not be available on your computer.

Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

How to register. Who should attend Services, both internal HP and external

HP Data Replication Solution Service for 3PAR Virtual Copy

HP Smart Array Controllers and basic RAID performance factors

HP Smart Storage Administrator User Guide

HP Personal Workstations Step-By- Step Instructions for Upgrading Windows Vista or Windows XP Systems to Windows 7

RAID-01 (ciss) B mass storage driver release notes, edition 2

Software Update, Backup, and Recovery

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS

UTC3100 and 3170 POS RAID Information

QuickSpecs. What's New. At A Glance. Models. HP StorageWorks SB40c storage blade. Overview

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

Using ATI Array Management Software (WebPAM)

Backup and Recovery User Guide

Guide to SATA Hard Disks Installation and RAID Configuration

VIA RAID Installation Guide

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology

Serial ATA RAID PCI. User's Manual

How To Use A Raid

WHITE PAPER. HP Guide to System Recovery and Restore

How to Restore a Windows System to Bare Metal

System Release Notes Express5800/320LB System Release Notes

HP StoreVirtual 4630 Storage Maintenance Guide

HP ProLiant power supply technology

SATARAID5 Serial ATA RAID5 Management Software

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

NVIDIA RAID Installation Guide

HP Z220, Z420, Z620, and Z820 Workstations Microsoft Windows XP Installation Reference Guide

Backup and Recovery User Guide

HP Online ROM Flash. User Guide

HP Smart Array E200 Controller User Guide

QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller

VIA / JMicron RAID Installation Guide

AMD RAID Installation Guide

HP External Hard Disk Drive Backup Solution by Seagate User Guide. November 2004 (First Edition) Part Number

HP Notebook Hard Drives & Solid State Drives. Identifying, Preventing, Diagnosing and Recovering from Drive Failures. Care and Maintenance Measures

This user guide describes features that are common to most models. Some features may not be available on your computer.

Configuring ThinkServer RAID 100 on the Lenovo TS130

HP Thin Client Imaging Tool

SMART INSTALL CONTENTS. Questions and answers

Getting Started. rp5800, rp5700 and rp3000 Models

RAID OPTION ROM USER MANUAL. Version 1.6

HP Smart Array SAS Controllers for Integrity Servers Support Guide

AMD RAID Installation Guide

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

BrightStor ARCserve Backup for Windows

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later

ITE RAID Controller USER MANUAL

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

HP Compaq notebook common image white paper

Windows 8 Backup, Restore & Recovery By John Allen

HP OpenView Internet Services. SNMP Integration with HP Operations Manager for Windows White Paper

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

HP Common Slot power supply technology

Smart Array technology: advantages of battery-backed cache

About Backing Up a Cisco Unity System

How To Use The Enhanced Write Filter On Windows Xp Embedded (Dota) With A Powerbook (Dot) And Powerbook 2 (Windows Xp) With An Overlay (Powerbook) With The Write Filter (Wfmgr) On A

HP PolyServe Software upgrade guide

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

This chapter explains how to update device drivers and apply hotfix.

Backup and Recovery User Guide

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

QuickSpecs. What's New HP 3TB 6G SAS 7.2K 3.5-inch Midline Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives. Overview

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

HP Array Technologies

Transcription:

RAID 1(+0): breaking mirrors and rebuilding drives How to, 3 rd edition Introduction... 2 Splitting a mirrored array using the Array Configuration Utility... 3 Recombining a split mirrored array using ACU... 4 Breaking a mirror and rebuilding the array using the manual method... 5 Reverting to a previous copy of a mirrored set using the manual method... 7 For more information... 9 Call to action... 9

Introduction When using a configuration with RAID 1(+0) volumes attached to Smart Array controllers, it may be necessary to break a mirror and rebuild the drives. For eample: When a drive in a RAID 1(+0) volume fails, the controller essentially breaks the mirror. An administrator subsequently can regain fault tolerance and resynchronize the mirror by inserting a replacement drive and allowing the controller to rebuild the drive automatically. As a precaution against a future failure situation, an administrator can break a mirror by removing half of the mirrored drives (which are saved as the system backup), replace them with other drives, and allow the controller to automatically rebuild the new drives to restore fault tolerance. (Reverting to a previous backup is more comple and is eplained later in this paper.) When increased capacity is required, an administrator can replace half of the drives in a RAID 1 or RAID 1+0 array with larger capacity drives and rebuild the new drives. Afterwards, the administrator can replace the other half of the drives and allow them to rebuild in the other direction. Once all drives in the array are of larger capacity, the administrator can use the Array Configuration Utility (ACU) to increase the logical drive size or to configure additional volumes. When troubleshooting drives or testing software configurations, an administrator can use half the mirror drives as a backup copy and then revert to that backup copy if a software configuration (for eample, an operating system patch) is unsuccessful. HP provides two utilities for configuring an array on a Smart Array controller: Options ROM for Configuring Arrays (ORCA) A simple ROM-Based configuration utility that runs on all operating systems Array Configuration Utility (ACU) A versatile, browser-based utility that provides maimum control over configuration parameters This paper eplains two methods for safely breaking a RAID 1(+0) mirror and rebuilding drives in configurations with RAID1(+0) volumes. The new ACU splitting mirror feature is available only on newer controller models and with the latest ACU versions. The legacy method for manually breaking a RAID 1(+0) mirror is supported on all Smart Array controller models. Table 1 shows which Smart Array controller models support the new ACU "Splitting a Mirrored Array" mechanism and which controllers support the manual mechanism described in this white paper. 2

Table 1. Smart Array controllers supporting ACU and manual methods of breaking RAID 1(+0) mirrors Supported Controllers ACU Method Manual Method All SAS Smart Array controller models Smart Array 6i, 641, 642, 6402, 6404 (with firmware version 2.58 or higher only) Integrated Smart Array SMART-2/P, SMART-2/E, SMART-2SL, SMART-2DH Smart Array 221, 3100ES, 3200, 431, 4200, 4250ES, 5i, 5i Plus, 532, 5312, 5302, 5304 Splitting a mirrored array using the Array Configuration Utility This functionality, available in some controller models and ACU versions, splits an array that consists of one or more RAID 1(+0) logical drives into two identical new arrays consisting of RAID 0 logical drives. This functionality is useful when replicating a configuration or building a backup before performing a risky operation. Note that this is a bit different from the manual method, in which the volumes remain in their original RAID 1 or RAID 1+0 configuration after being split. Also note that this method does not require splitting other arrays attached to the controller at the same time. IMPORTANT You cannot split an array if it contains logical drives in RAID 0, RAID 5, or RAID ADG configurations. You can split or remirror an array only when the server is offline and operating in the Standard configuration mode of the ACU GUI. To split a mirrored array using the Array Configuration Utility, complete the following steps: 1. Take the server offline. 2. Insert the CD that contains ACU into the CD-ROM drive. 3. Open ACU, and stay in Standard configuration mode (the default). 4. Select the controller that contains the array to be split. 5. In the Configuration View panel, select the array. 6. In the Select a Task panel, click Split Mirrored Array. 7. Click OK. 8. When ACU has finished splitting the array, shut down system. 3

9. Remove the physical drives that constitute one of the new arrays. IMPORTANT If you do not remove one of the arrays, the server will be unable to distinguish between the two new arrays after the server is restarted (net step) because the arrays will be identical. 10. Restart the server. Recombining a split mirrored array using ACU You can split or remirror an array only when the server is offline and operating in the Standard configuration mode of the ACU GUI. To remirror an array using ACU, complete the following steps: 1. Take the server offline. 2. Insert the drives that contain the other half of the split array. 3. Insert the CD that contains ACU into the CD-ROM drive. 4. Open ACU, and stay in Standard configuration mode (the default). 5. Select the controller that contains the array to be remirrored. 6. In the Configuration View panel, select the array to use as the source array in the recombined mirrored array. 7. In the Select a Task panel, click Re-Mirror Array. 8. Select the array that is to be mirrored to the source array. (This is usually the array that was originally split out of the original mirrored array. However, it can be another array if it is of the correct size.) CAUTION All data on the second array will be destroyed. 9. Click OK. 10. When ACU has finished recombining the split array, restart the server. For more information or to download the Array Configuration Utility, please refer to this URL: http://h18004.www1.hp.com/products/servers/proliantstorage/software-management/acumatri/inde.html 4

Breaking a mirror and rebuilding the array using the manual method CAUTION Use the following procedure for configurations with only one array on the controller. If multiple arrays are configured on a single controller, all arrays (and consequently all logical drives within each array) must be broken and restored together. Because of the added compleity, this method of creating a quick backup of the logical drives is strongly discouraged in configurations with multiple arrays per controller. A mirror can be broken simply by removing a drive while the server is online. However, to preserve the data on drives being removed, it is necessary to shut down the system first. If the removed drives will be used to restore the system, or if the data on the drives will be required for any reason, follow these steps eactly to break a mirror: 1. Verify that the controller is configured with RAID 1 (or RAID 1+0) logical drives only. 2. Shut down the operating system (to ensure clean file system shutdown) and the server. 3. With the power off, remove one half of the mirror (the backup) label each of the removed drives with its respective drive bay number, and store these drives in a safe place. For two-drive configurations, just remove one drive. For RAID 1+0 configurations, the first n/2 drives are always mirrored to the second n/2 drives. If the array contains more than two drives, do not remove drives that are mirrored to one another. 4. Restart the system with the remaining half of the mirror. 5. During boot-up, a message will indicate that the drives are not responding (Figure 1). Press F2 to fail the missing drive(s) and continue in recovery mode. All drives on the controller will remain disabled until F2 is pressed. If you press F1 by mistake, simply reboot again and press F2 to fail the drives. 5

Figure 1. A boot-up message indicates that the logical drive is still available but missing physical drives. If the logical drive is failed at this point and the system will not boot, most likely two drives that were mirrored to one another have been removed. If this occurs, shut down the system, reinstall all drives, and turn the system back on. The drives that were mirrored to one another will be marked okay and all data should still be intact. Start again at step 1, being careful not to remove any drives that are mirrored to one another. 6. Insert a new drive into the open drive bay and the array rebuild should start automatically. If the rebuild does not start automatically, run the Array Configuration Utility to initiate the rebuild. For complete information about running ACU, refer to the resources cited at the end of this document. The drive-online LED will blink during the rebuild process. When it stops blinking and turns solid green, the rebuild is complete. On a 36-GB Ultra 320 drive, depending on the number of IOPS the server is submitting to the controller, it takes about 6 minutes to rebuild a mirrored array when the controller rebuild priority is set to high. 7. After the rebuild is complete, proceed with the OS boot. Rebuilding the array will bring the array back into a fault-tolerant state. If the mirror was broken simply to try an operating system patch, it is normally not necessary to make the array fault-tolerant again until after the patch is tested. 6

Reverting to a previous copy of a mirrored set using the manual method This method only works if the mirrored set was originally broken using the manual method (not the new ACU method). CAUTION Before inserting the backup drives (in step 1 below), verify that all drives from the current array have been removed. Any drive that became part of the array during a rebuild process can OVERWRITE the BACKUP drive. Be especially careful in using hot spares, where the rebuild may have happened automatically and it is unclear whether another drive is now part of the array. To simplify this process, HP strongly recommends removing any spares before breaking the mirror and reinstalling the spares only after the array is rebuilt. To revert to a previous copy of a mirrored set, complete the following steps: 1. With the system off, remove all drives from the array, and insert the drives containing the backup data (the image the array will revert to). The backup drives must be installed in their original locations. (If it is unclear which drive bay a backup drive came from, insert the drive into one of the drive bays where the array was created and continue with caution; it may be necessary to move it if a logical drive is not detected during boot-up). 2. Restart the system with only the backup drives installed. If no logical drives are found during boot-up (Figure 2), a drive is most likely in the wrong drive bay. If that happens, turn off the server, pull the drive out, and place it into another slot; then turn the server back on again. 7

Figure 2. Boot-up message indicating no logical drives were found and that the backup drives are probably in the wrong drive bays 3. During boot-up, the message will indicate that the drives are not responding (Figure 12). Press F2 to fail the missing drive and continue with one drive in recovery mode. 4. Insert the drive to be overwritten into the open drive bay, and the array rebuild should start automatically. If the rebuild does not start automatically, run the Array Configuration Utility to initiate the rebuild. CAUTION It is critical that the drives to be overwritten are hot inserted; they must not be installed while the server is off. The drive-online LED will blink during the rebuild process. When it stops blinking and turns solid green, the rebuild is complete. On a 36-GB Ultra 320 drive, depending on the number of IOPS the server is submitting to the controller, it takes about 6 minutes to rebuild a mirrored array when the controller s rebuild priority is set to high. 5. After the rebuild is complete, proceed with the OS boot. 8

For more information For additional information, refer to the resources listed below. Resource description Business Support Center for HP Array Configuration Utility Configuring Arrays on HP Smart Array Controllers Reference Guide Web address http://h20000.www2.hp.com/bizsupport/techsupport/home.jsp?lang=en& cc=us&prodtypeid=18964&prodseriesid=468780 http://h20000.www2.hp.com/bc/docs/support/supportmanual/c00 729544/c00729544.pdf Call to action Send comments about this paper to TechCom@HP.com. 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the epress warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. TC070201HT, February 2007