Energy Conservation through Introduction of Highly Efficient Air Separator and Use of Large Compressor



Similar documents
Energy Conservation Measures due to Industrial Gas Supply Business Model Innovation

Energy-efficient Products for Better use of Energy in the Home

Oxygen generation. By Vacuum Pressure Swing Adsorption.

How does solar air conditioning work?

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Transportation of Hydrogen by Pipeline - Kunihiro Takahashi TRANSPORTATION OF HYDROGEN BY PIPELINE

Efficiency of Hydrogen Liquefaction Plants

Top Technology for Industry, Agriculture, Business and Communities

TABLE OF CONTENT

Biogas as transportation fuel

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

AdSORPTION CHILLER NAK

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

ECONOMICAL OPTIONS FOR RECOVERING NGL / LPG AT LNG RECEIVING TERMINALS

HELIAL liquefiers. Range of automatic helium liquefiers.

Kompressoren. Oil Water Separators OWS

ThermoStar Refrigeration Air Dryers

Kompressoren. Adsorption Dryer AD

VACUUM REFRIGERATION SYSTEMS

Applying Life Cycle Assessment to Drinking Water Treatment

Lasline, Nitrocut, Oxycut gases for laser cutting, Expertise that gets right to the point

GREEN PROCUREMENT GUIDELINES

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Tokyo Steel s Views to Global Warming revised on June 25, 2010 with the latest data

Fujitsu Group s Environmental Management: Outline of Environmental Protection Program (Stage IV)

State of the Art Energy Efficient Data Centre Air Conditioning

UOP Gas Processing. Realizing the Value of Your Natural Gas and Synthesis Gas Resources

With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

GAS HEATING IN COMMERCIAL PREMISES

LG Electronics AE Company, Commercial Air Conditioning

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

Fujitsu Semiconductor Technology Inc. Sustainability Report

Desiccant Air Dryers Heatless, Heated and Heated Blower

UNIT 2 REFRIGERATION CYCLE

John KW Hou, Ph.D. World- Wide Director, Industry Solutions Member of IBM Industry Academy IBM Corporation. José R. Favilla Jr

This chapter is devided into two sections:

ENVIRONMENTAL IMPACTS OF CARBON DIOXIDE AND DRY ICE PRODUCTION

How Ground/Water Source Heat Pumps Work

Environmental Performance Data Calculation Standards

Future. Future-Oriented Strategies

How To Make A High Co 2 Gas Blend

Bio-CNG plant. Spectrum Renewable Energy Limited, Kodoli, Kolhapur

We make rational and conscientious use of our

GTI Small-Scale Liquefaction Technology. March 2013

Saeid Rahimi. Effect of Different Parameters on Depressuring Calculation Results. 01-Nov Introduction. Depressuring parameters

Development of Coal Gasification System for Producing Chemical Synthesis Source Gas

Putting a chill on global warming

Optimization of Natural Gas Processing Plants Including Business Aspects

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Description of Thermal Oxidizers

Hydrogen Production via Steam Reforming with CO 2 Capture

Industrial Gases Praxair, Inc.

CRG CONSERVE RESOURCES GROUP ECO ENVIRONMENTAL ENGINEERING TECHNOLOGIES. NEW State of the Art. Advanced OIL REFINERY TECHNOLOGY & PROCESSES

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

NATURAL GAS EXPERIENCE

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Dry-out Design Considerations and Practices for Cryogenic Gas Plants

Lecture 35: Atmosphere in Furnaces

The Second Law of Thermodynamics

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Glossary of Heating, Ventilation and Air Conditioning Terms

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Chapter 3.4: HVAC & Refrigeration System

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal

Wastewater Reuse. Typical treated wastewater is:

Dry Ice Cleaning. New opportunities with FerroČrtalič d.o.o.

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

Year project completed or estimated year of completion: October 2014

Validation of process gas systems

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Sondex Welded heat exchangers:

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Production of R-134a

A/C refrigerant system, overview

Innovative to the Core

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Coal-To-Gas & Coal-To-Liquids

North American Stainless

ARP Food Industry, Portugal

ThermoSorb Desiccant Dryers

Gas Detection for Refining. HA University

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Instrument Gas to Instrument Air Conversion Protocol October 2009 SPECIFIED GAS EMITTERS REGULATION OCTOBER Version 1.0.

HIGH STANDARD VALVES FOR NON-STANDARD CONDITIONS.

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

Natural Gas Information Contents

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Experimental Study on Super-heated Steam Drying of Lignite

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

History of Chlorofluorocarbons

THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY

FACTS ABOUT CLIMATE CHANGE

CONDENSATE MANAGEMENT

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Crowne Plaza Copenhagen Towers The world s greenest hotel

Thermostatic valve Type AVTA

Gas processing plants

Transcription:

2007 Prize of Director General of Agency for Natural Resources and Energy Energy Conservation through Introduction of Highly Efficient Air Separator and Use of Large Compressor Air Water Inc. Plant Division Onsite Department, Wakayama Manufacturing Plant, Manufacturing Section Keywords: Others (rationalization of introduction of highly efficient facilities and use of highly efficient equipment) Outline of Theme A significant amount of energy was conserved by introducing highly efficient compressors to raw material air compressors and oxygen compressors as well as by introducing a highly efficient cryogenic air separator that adopts a raw material air preprocessing system and packing tray method. Furthermore, energy was further conserved through diverting the large raw material air compressor, which became redundant due to the introduction of a highly efficient cryogenic air separator, to compressor for compressed air only, thereby making it possible to terminate the operation of the compact compressors scattered throughout the manufacturing plant. Implementation period for the Said Example April 2003 through December 2008 Project Planning Period: April 2003 through December 2004 Total of 14 months. Implementation period: July 2004 through February 2006 Total of 19 months. Effect verification period: March 2006 through December 2008 Total of 33 months. Outline of the Business Establishment Production items: Gas and liquefied gas. Number of employees: 32 persons. Annual energy consumption: 438,946 Mwh/year (actual record for 2006). Type 1 Designated Energy Management Factory. 1

Process Flow of Target Facility Compressed air Compact air compressors (operation terminated) Compres sed air (high pressure) Compressed air (low pressure) Oxygen compressor Sumitomo Metal Industries, Ltd. (1) Air (2) Oxygen (3) Low purity (waste) nitrogen (4) High purity nitrogen (5) Argon Atmospheric air Room temperatu Room temperature MS absorber Raw material air compressor Main heat exchanger Main condenser Argon purification Argon tanks (packed column) Figure 1: flow diagram 1. Reasons for Theme Selection As the energy conservation activity in line with a voluntary activity plan formulated by the Japan Chemical Industry Association, to which this company belongs, company set the target to reduce energy intensity by 90% from 1990 figure by the year 2010 through making every effort.. This energy conservation project contributes to a reduction of energy intensity of the factory by 11.9 %, therefore the project offers the greatest contribution to the global environment among various energy conservation activities we promote. 2. Understanding and Analysis of Current Situation The target to reduce energy intensity by 90% from 1990 figure by the year 2010 was already greatly exceeded with a reduction of about 40%. Due to the increased amount of production, however, the actual electric power consumption increased in 2006 by 3 % over that of 1990. In order to suppress the emission of the carbon dioxide, which is the cause of global warming, it is essential to reduce electric power consumption. It is necessary to set the future targets and to consider the plans for attaining such targets. 2

3. Progress of activities (1) Implementation Structure The Wakayama Manufacturing Plant is playing a central role in this major energy conservation project, as shown in Figure 2, and discussions are being held freely and unrestrainedly among other corporate organizations and group companies to promote this big energy conservation project with becoming unity. Onsite Department Wakayama Manufacturing Plant Plant Engineering Planning Department Air Water Plant & Engineering Inc. (1) Design (2) Order Plant Manager Manufacturing AW Section Maintenance (Clerical office) Inc. Maintenance Planning Department AW Maintenance Inc. Solution Technologies Office (1) Foundation construction (2) Installation work (1) Process analysis Manufacturing Section (Operations Team) Procurement Office (1) Procurement Figure 2: Framework for activities (2) Target Settings [1] The NEDO energy conservation target of 14,000 kiloliters/year, reduction by 6550 kw (energy intensity reduction of 12 %). [2] A 10 % reduction of the energy intensity of 1990 by the year 2010 is an energy conservation target in line with voluntary activity plans formulated by the Japan Chemical Industry Association. (3) Problem Points and their Investigation As described in Section 2, Understanding Current Status and Analysis, it will be possible to achieve the target in terms of energy intensity, as long as the current trend is maintained. Since it is critical for the actual electric power consumption to be reduced in order to suppress the emission of carbon dioxide, which is the cause of global warming, it is necessary to set energy reduction targets for the future and consider plans for attaining such targets. It is necessary to reduce the electric power consumption in 1990 (carbon dioxide 3

emission) by 6 % or less by 2012 in accordance with the Kyoto Protocol. This is the most crucial target for the future. Since achieving this figure is extremely difficult, drastic structural reforms for energy usage are unavoidable. For this reason, an energy conservation plan was formulated and put into action, which is introduced as the case example. [1] Introduction of highly efficient cryogenic air separator [2] Conversion of large raw material air compressor to a compressor for compressed air only 4. Details of Measures Improvements were made to the operations of three units, plant numbers 10, 11 and 12 (terminating the operation of plant numbers 8 and 9, which had energy intensity) by introducing highly efficient compressors as the raw material air compressors and oxygen compressors, as well as introducing a highly efficient cryogenic air separator (plant number 12) that adopts a raw material air preprocessing system and packing tray method. Also, the highly efficient cryogenic air separator was not merely introduced but its pervasion was also pursued. Furthermore, through diverting the large raw material air compressor, which became redundant due to the introduction of a highly efficient cryogenic air separator, to compressor for compressed air only, the inefficient compact compressors scattered throughout the manufacturing plant was terminated. (1) Increasing efficiency of framework for supplying compressed air by utilizing large air compressors Compressed air is currently being supplied through two systems. Through cooperation granted by Sumitomo Metal, it is now possible to supply compressed air with a low pressure, except for some destinations that require compressed air with a high pressure. This made it possible to supply an excessive amount of raw material air to the plant as compressed air. Furthermore, compact air compressors could be taken out of operation by supplying an excessive amount of air from large compressors. Large raw material air compressors have a lot more superior energy intensity than that of compact ones, thereby providing a substantial conservation of energy. Since the discharge pressure of the raw material air compressor (plant number 12) at the 4

newly established plant of this division is low, cooperation has been requested of Sumitomo Metal to accept an even lower pressure for the supply of compressed air. (This time: 0.42 MPa 0.38 MPa) Compact air compressors are taken out of operation (standby units) Air booster Compressed air (high pressure) 0.6 MPa Air Compressed air (low pressure) 0.38 MPa Large air compressor Air Raw material air compressor No. 7 (plant No. 8) Taken out of operation (standby unit) Raw material air compressor No. 9 Raw material air compressor No. 10 (plant No. 9) Taken out of operation (disposed of) (plant No. 10) Sumitomo Metal Industries, Ltd. Raw material air compressor No. 11 (plant No. 11) Raw material air compressor No. 12 (plant No. 12) New installation Figure 3: Framework for supply of gas (2) Increasing efficiency by adopting raw material air preprocessing system Losses arising from switching the reversible heat exchanger and liquid oxygen adsorber were eliminated by the adoption of the raw material air preprocessing system, resulting in an improvement of the product recovery rate. 5

<Before implementation> Rivex (reversible exchanger) (1) Removal of moisture and carbon dioxide in raw material air. (2) Heat is exchanged between raw material air at room temperature and separated cryogenic gas a. Raw b. Raw Room temperature Room temperature <Time I> Heat exchange Switchover time Approx. 10 min. Heat exchange <Time II> Low temperature High purity nitrogen Oxygen Low temperature High purity nitrogen Oxygen Switching valve Switching valve Low purity nitrogen Low purity nitrogen The alternated switching of gases from route a and b is performed by time control, with the moisture and carbon dioxide from the eliminated raw material oxygen scavenged outside of the system with a low purity nitrogen. Figure 4: Swtchover of Rivex (reversible heat exchanger) <After implementation> MS adsorption tower Moisture, carbon dioxide gas and hydrocarbons in raw material air are removed. Main heat exchange Heat is exchanged between raw material air at room temperature and separated cryogenic gas. Room temperature Raw material air Heat exchange MS adsorption tower (preprocessing) One tower used, one tower for recycling Switchover frequency: Four hours. Low purity nitrogen High purity nitrogen Oxygen Figure 5: Raw material air preprocessing system and main heat exchanger (3) Introduction of highly efficient cryogenic air separator It was possible to reduce the power of compressors by about 10 %, through the lowering of the discharge pressure of the raw material air compressor, since the introduced packing tray-type (filler) air separator has little pressure losses in comparison with the conventional sheave tray-type (porous plate). 6

Conventional (fractioning plate-type) porous plate-type Flow direction of liquid Flow direction of gas Fractioning plate Schematic diagram Rising gas (heat exchange with gas from below results in partial conversion into gas) Liquid (rising gas from below is liquefied) Porous plate Rising gas (from lower levels) Schematic diagram of fractioning principle Figure 6: Type comparison diagrams for cryogenic air separators (conventional) After introduction (filler-type packing tray) Descending liquid Fillers (comprised of thin plates processed in ribbed form) One element (180 to 200 mm) Plate Descending liquid Rising gas Schematic diagram Rising gas Descending liquid becomes a thin membrane on the surface of fillers Figure 6-b: Type comparison diagrams for cryogenic air separators (after implementation) 7

(4) Energy conservation with adopting of lower purity standard for oxygen gas (99.6 99.4 %) The rated oxygen purity for cryogenic air separator is 99.6 % or more. However, by lowering the purity, it is possible to reduce the amount of raw material air required to manufacture oxygen at 1 Nm 3 /h. On the other hand, issues induced by the lowering of oxygen purity at the steel mill were as follows: [1] A rise of nitrogen concentration in the steel due to a rise in the concentration of nitrogen contained in oxygen gas. [2] A reduction of the production amount due to an extension in the blowing and welding time. Such issues were considered and tested in collaboration with Sumitomo Metal, which led to the conclusion that as long as the purity is maintained at 99.4 % or higher, no operational problems occur. Accordingly, the purity standard of oxygen gas for the implemented cryogenic air separator was set to 99.4 % or more. (5) Effects arising from termination of operation of medium and high pressure oxygen plants The operations of the medium pressure oxygen plant (number 8) and the high pressure oxygen plant (number 9), with an extremely low air separation intensity, were terminated. Furthermore, the waste disposal of oil absorption mats and lubricating oil became unnecessary as the operation of the high pressure oxygen plant was terminated, making it possible to terminate the operation of the Freon refrigerator (R-22). 5. Effects achieved after Implementing Measures Targeted figures: [1] The NEDO energy conservation target of 14,000 kiloliters/year, reduction by 6,550 kw (energy intensity reduced by 12 %). [2] A 10 % reduction in the energy intensity of 1990, by the year 2010, is an energy conservation target set in line with voluntary activity plans formulated by the Japan Chemical Industry Association. These targets have been reached, as indicated in the Table.1. As long as the current trend is maintained, the national target which intends to 8

reduce the energy intensity of 1990 by 10% by the year 2012 will be attained, since the target already being greatly exceeded with a reduction of about 40 %. Table 1: Results of energy conservation by relevant party NEDO (Actual standard record) FY1990 FY2003 FY2004 FY2005 FY2006 Oxygen consumption knw 3 /h 32.3 52.0 50.2 54.2 59.0 Energy Intensity kwh/nm 3 1.498 1.013 1.050 0.971 0.849 (energy unit consumption) Energy intensity rate % 100 67.6 70.1 64.8 56.7 Electric power consumption MWh/year 423,786 462,769 461,886 461,165 438,946 Electric power consumption rate % 100 109.2 109.0 108.8 103.6 figures recorded Actual Table 2: Crude oil equivalent Crude oil equivalent kl/year Actual consumption for FY2003 117,543 FY2006 Actual consumption (after project implementation) 111,492 Unit consumption base 103,341 Amount of conserved energy (figures provided inside brackets) 14,202 Intensity base (14,000) Electric power kw 6,558 (6,550) Table 3: Comparison of unit consumption amounts Actual record for FY2003 (before project implementation) Actual record for FY2006 (after project implementation) Overall Intensity for raw material air compressors 0.0880 0.0806 Overall air separation intensity for plants kwh/nm 3 0.579 0.483 6. Summary A subsidy was obtained from NEDO to conduct this project, with the operation of a new plant starting in January 2006. It was possible to attain the energy conservation target of NEDO, in terms of crude oil equivalent, 14,000 kiloliters/year, a reduction by 6,550 kw (energy intensity reduction of 12%) or more. It was possible to significantly exceed the target for reducing the 1990 energy intensity by 9

90 % by the year 2010, an energy conservation target set in line with a voluntary activity plan formulated by the Japan Chemical Industry Association, to which this company belongs. This was possible due not only to the energy conservation activities implemented by the company, but rather, as a result of cooperation with the customer Sumitomo Metal. 7. Future Plans As described in the previous section, the targeted energy intensity has been attained. Due to the increased amount of production, however, the electric power consumption increased in 2006 by 3 % over that of 1990. In order to suppress the emission of carbon dioxide, which is the cause of global warming, it is essential for this electric power consumption to be reduced. In order to ensure that the target of reducing the 1990 carbon dioxide emissions by 6 % by the year 2012, as stipulated by the Kyoto Protocol, energy reduction targets will be set and plans for attaining such targets will be considered (For example, the building of highly efficient plants equivalent to the one built for this project or optimized operational combinations with existing plants, etc.). 10