Instructions for creating Silva Cell 2 layouts using AutoCAD



Similar documents
Layouts, Plotting, Printing

Geometry Notes VOLUME AND SURFACE AREA

SketchUp Instructions

Calculating Area, Perimeter and Volume

Interlocking Concrete Paving Stones

SECTION 5 DRAFTING STANDARDS

All I Ever Wanted to Know About Circles

Road Rehabilitation and Reconstruction Using AutoCAD Civil 3D

Basic Elements of Reading Plans

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

CATIA Drafting TABLE OF CONTENTS

Creating Smart Models From Scan Data

PERC-RITE DRIP DISPERSAL DESIGN GUIDE FOR SEPTIC TANK OR ADVANCED TREATMENT EFFLUENT MAINE

Interlocking Concrete Paving Stones

Student Outcomes. Lesson Notes. Classwork. Exercises 1 3 (4 minutes)

Area of Parallelograms, Triangles, and Trapezoids (pages )

Generative Drafting. Page DASSAULT SYSTEMES. IBM Product Lifecycle Management Solutions / Dassault Systemes

CATIA Functional Tolerancing & Annotation TABLE OF CONTENTS

LS 2540 SEWER LATERALS AND INSPECTION TEES

Storm Drainage Systems

Characteristics of the Four Main Geometrical Figures

Geometry Notes PERIMETER AND AREA

Area of Parallelograms (pages )

BMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.

3D Drawing. Single Point Perspective with Diminishing Spaces

Area and Circumference

Volume of Right Prisms Objective To provide experiences with using a formula for the volume of right prisms.

Tallahassee Community College PERIMETER

12-1 Representations of Three-Dimensional Figures

DESIGN GUIDELINES FOR EARTH RETENTION

Introduction to CATIA V5

Geometry Solve real life and mathematical problems involving angle measure, area, surface area and volume.

CATIA Electrical Harness Design TABLE OF CONTENTS

ACTIVITY: Finding a Formula Experimentally. Work with a partner. Use a paper cup that is shaped like a cone.

What s New V 11. Preferences: Parameters: Layout/ Modifications: Reverse mouse scroll wheel zoom direction

Green Streets, Places, and Spaces

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES

Using Hydraflow Storm Sewers Extension with AutoCAD Civil 3D 2008: A Recommended Workflow

MATH 110 Landscape Horticulture Worksheet #4

Chapter 3 SENSITIVE AREAS AND VEGETATED CORRIDORS

Volume of Pyramids and Cones

Weld Design. CATIA V5 Training Foils. Weld Design. Copyright DASSAULT SYSTEMES 1. Instructor Notes:

Drawing a Bedroom Floorplan

SECTION INLETS INLET LOCATIONS

DESIGN AND ASSEMBLY OF A CELL-PHONE USING CATIA V5-R17 AMER MOUSTAPHA EL SANKARI. Under supervision of Professor Dr. Chevy Zezhong Chen

Perimeter. 14ft. 5ft. 11ft.

Chapter 19. Mensuration of Sphere

Circumference CHAPTER. 1

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

Dimensioning and Estimating Brick Masonry

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

8 th Grade Task 2 Rugs

Geometry - Calculating Area and Perimeter

3D Laser Scanning for Manufacturing Facilities Developing the Business Case. By Bill Campbell Founder, Digital Dimensions 360, LLC

Perimeter, Area, and Volume

Mensuration. The shapes covered are 2-dimensional square circle sector 3-dimensional cube cylinder sphere

7.2 Quadratic Equations

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

AB Courtyard Collection

CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING DEVELOPMENT WITH OPEN SPACE PROVISION

3D Modeling in Vectorworks 2009 by Jonathan Pickup. mple

Sample Punch List. Garth Ruffner Landscape Architect (916) Page 1 of 5

VOLUME of Rectangular Prisms Volume is the measure of occupied by a solid region.

Inv 1 5. Draw 2 different shapes, each with an area of 15 square units and perimeter of 16 units.

Fig. 1. Background. Name: Class: Date:

MD5-26 Stacking Blocks Pages

HOW TO TAKE A COMPASS READING

How To Create A View Frame In 3D

Lesson 21. Circles. Objectives

MECHANICAL PRINCIPLES HNC/D MOMENTS OF AREA. Define and calculate 1st. moments of areas. Define and calculate 2nd moments of areas.

Table 4.9 Storm Drain Inlet Protetion Applicable for

3D Drawing. Single Point Perspective with Diminishing Spaces

Geometry Unit 6 Areas and Perimeters

Chapter 12: Three Methods for Computing the Volume of a Lake

CHAPTER 8, GEOMETRY. 4. A circular cylinder has a circumference of 33 in. Use 22 as the approximate value of π and find the radius of this cylinder.

How To Find The Area Of A Shape

Area & Volume. 1. Surface Area to Volume Ratio

Toronto's New Soil and Tree-based Standards for Boulevards

Micromanagement of Stormwater in a Combined Sewer Community for Wet Weather Control The Skokie Experience

NEW GENERATION OF COMPUTER AIDED DESIGN IN SPACE PLANNING METHODS A SURVEY AND A PROPOSAL

An introduction to 3D draughting & solid modelling using AutoCAD

ENGLISH CONTENT. Instructions for Using Your Computer Watch

APPENDIX M-2 SANITARY SEWER TECHNICAL MEMORANDUM. Stadium Reconstruction EIR

Measurement: Converting Distances

Layout Tutorial. Chapter 10: Getting Started

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

Measurement of Length, Mass, Volume and Density

Diametral Pitch Gear Ratios Herringbone Gears Idler Gear Involute Module Pitch Pitch Diameter Pitch Point. GEARS-IDS Optional Gear Set Straight Edge

GYM PLANNER. User Guide. Copyright Powerzone. All Rights Reserved. Software & User Guide produced by Sharp Horizon.

THE DEWALT RAFTER SQUARE

WFTDA TRACK LAYOUT GUIDE

Imperial Length Measurements

Introduction to Autodesk Inventor for F1 in Schools

Application Example: Quality Control. Turbines: 3D Measurement of Water Turbines

The process components and related data characteristics addressed in this document are:

Lesson 4: Surface Area

DRAFTING MANUAL. Gears (Bevel and Hypoid) Drafting Practice

Transcription:

Instructions for creating Silva Cell 2 layouts using AutoCAD Part 1: Setup, Layout Information, and Constraints Part 2: Laying Out the Silva Cell System in Regular Tree Openings Part 3: Laying Out Silva Cells in Irregular Tree Openings

How to Create a Silva Cell 2 Layout in AutoCAD Note: We are assuming the user has prior CAD knowledge, and won t be going through the basics of set up. We are using AutoCAD 2015; please adjust for the version that you re running. Part 1: Setup, Layout Information, and Constraints 1) Open the project CAD base file and define tree location(s) Open the project CAD base plan that you will be using to produce the Silva Cell site design.this example depicts a streetscape, but the Silva Cell System can be used on other sites besides streetscapes, including plazas, parking areas, and more. Be sure that the base plan includes the location of the trees and the extents of the tree root package, if known. FIGURE 1-1. Setting up CAD Base File.

2_ Assign drawing units to CAD base Ensure the correct drawing units are assigned to your base CAD file. This step is essential to ensure that the Silva Cell CAD block comes in to your drawing at the correct scale in Part 2 (see Figure 1-2). Note: The Silva Cell CAD blocks are provided in decimal units - millimeters (mm), meters (m), feet (ft), and inches (in) as well as architectural inches (in) FIGURE 1-2. Assigning Drawing Units to CAD Base File.

3) Define and locate the edges of all tree openings/planters Locate and define both the inside and the outside edges of each tree opening on the plan (see Figure 1-3). It is critical that the tree opening is fully supported by Silva Cells, and by defining the inside and outside edges you will ensure full support of the entire opening. The inner edge will be the starting point for laying out the Silva Cells in Part 2. FIGURE 1-3. Locating the Inner and Outer Edges of the Tree Opening.

4) Identify all subsurface features located within the layout area Determine what information about subsurface features you need to include in your base CAD drawing that could affect the location and depth of the Silva Cell layout. Figure 1-4 shows that the example CAD file contains some critical information about features that will need to be integrated into the layout or worked around when producing the Silva Cell layout. Note: Because they are modular, independent stacks, Silva Cells can be laid out to accommodate many subsurface features. FIGURE 1-4. Common subsurface features notes for Silva Cell consideration on the project site

5) Define areas where Silva Cells cannot be located Determine the location and extents of the site areas or features that cannot accommodate Silva Cells. For example, your site may have accessibility ramps or other common features such as building foundations, catch basins, or utility vaults that need to be avoided when installing Silva Cells and therefore must be delineated in your layout. Other common site features include required offsets or setback distances from utilities, curbs, pipes, or other features. You will need to provide space between the back of the curb and the face of the Silva Cells for proper soil compaction around the system. As shown in Figure 1-5, DeepRoot recommends a minimum of 12 (300mm) for the compaction area. The orange lines shown in Figure 1-5 define the No Silva Cell locations. Try to integrate all of those constraints to delineate the area where we will actually be using Silva Cells. FIGURE 1-5. Delineating the locations of subsurface areas unsuitable for Silva Cells on the project site.

6) Define the areas where Silva Cells can be located Now that the No Work areas have now been determined, what remains is the area(s) where Silva Cells can be located. The dashed area shown in Figure 1-6 indicates the areas on the site appropriate for Silva Cells. FIGURE 1-6. Defining the area(s) suitable for Silva Cell layout on the project site.

Part 2: Laying Out the Silva Cell System in Regular Tree Openings 1) Bring in the Silva Cell CAD block These blocks are provided in a number of standard formats on the DeepRoot website. You assigned the project drawing units to your CAD file in Part 1.2. Using these assigned units as a reference, select and insert the correct Silva Cell block into your CAD file. If the assigned CAD drawing units and the selected Silva Cell block match, the Silva Cell block should come in at the correct scale. FIGURE 2-1a. Insert the scaled CAD block in the project drawing. FIGURE 2-1b. Note the reference standard Silva Cells spacing lines on the scaled CAD block. Note: In this example, we have the drawing units shown in decimal feet in Figure 2-1. The Silva Cell dimensions are shown on each of these blocks, with the extents of each Silva Cell outlined in red. Deep- Root recommends typical spacing of 1 4 (25 mm - 100 mm) between cells as measured at the base, which is indicated in gray in the image to the left. Keep in mind that the blocks should not be right up against each other.

2) Start the layout at the edge of the tree opening Start your layout at the inside of the tree opening, and work outward from there. The Silva Cells need to align with the inner edge and completely support the entire tree opening. Make sure that the tree opening is completely supported at the edge. The orientation of the Silva Cells does not matter, so adjust them as necessary to fit your tree opening and limit of work. If your planters have different dimensions than the ones depicted here, simply adjust the orientation and/or spacing of the cells to support that edge. For circular or irregular shaped planters, refer to Part 3. FIGURE 2-2. Layout the Silva Cells defined in Part 1-6, starting with supporting the tree opening inner edge.

3) Complete the Silva Cell layout for all tree openings If your tree opening is typical and repeated in your site design, you can grab and copy the Silva Cell layout created for the first tree and apply it to other like tree openings. Fine-tune the layout as necessary to provide continuous support of the tree opening edges and work around the constraints in the Silva Cell layout area that you defined in Step 1-6. FIGURE 2-3. Complete the layout for all tree openings, working outward from the inner edge. 4) Infill Silva Cells between tree openings Once the support of tree opening edges is established (Steps 2-2 and 2-3), work outward from the tree openings to the extents of the limits of work, maintaining the typical 1-4 (25 mm - 100 mm) spacing between adjacent Silva Cells. Where possible, we recommend connecting tree openings using Silva Cells. If the tree is adjacent to soil volumes such as lawns or parks, use Silva Cells to create an access channel for roots to grow from the tree opening to those areas. Trees don t care about the configuration of the Silva Cells; just the overall quantity and access to the available soil volume. Adjust the extents, locations, and quantities of Cells as necessary per your individual project design parameters and soil volume/stormwater management goals. FIGURE 2-4. Infill Silva Cells between tree opening areas, making spacing adjustments as necessary.

5) Review the Silva Cell layout Once the layout is completed, remove the bounding lines on the block that indicate the spacing, and the internal structural pieces such as the posts, in order to see how the layout is configured. Since you set up the constraints in Steps 1-4 and 1-5, you should be able to verify that the layout is located outside of those areas. Edit as necessary. After this review, you should be able to construct the layout as drawn and with minimal field adjustments. FIGURE 2-5. Review and revise the completed Silva Cell layout to meet project goals.

Part 3: Laying Out Silva Cells in Irregular Tree Openings When working on a layout that uses circular, diamond-shaped, or other irregular tree openings, the same steps in Parts 1 and 2 still apply you will simply need to allow for some extension of the Silva Cells beyond the circular edge and into the planters. The steps to a successful layout for common irregular tree openings are below. A. Circular Tree Openings 1) Start the layout at the edge of the tree opening The Silva Cells will need to extend into the tree opening to completely support the inner edge. Start your Silva Cell layout at the tree opening, rotating and adjusting the spacing of the Silva Cell blocks along the inner edge of the tree opening. It is usually easiest to work from this inner edge outwards in a more-or-less geometric pattern inscribed in the circular opening. This geometry allows you to maintain the standard 1-4 (25mm - 100mm) spacing between Silva Cells while minimizing their extensions into the tree opening. Note: There will be some necessary extension of the layout into the tree opening with circular planters. Try to keep that to a minimum by experimenting with various orientations and configurations. The larger the diameter of the planter, the less extension of the Silva Cells into the tree opening should be necessary. Be sure that the tree opening is completely supported at the edge. Again, the orientation of the Silva Cells do not matter, so adjust them as necessary to fit your tree opening and limits of work. 2) Work Silva Cells outward to connect tree openings Once the support of tree opening edges is established (Step 3.1), work outward to the extents of the Limits of Work while maintaining the typical 1-4 (25mm - 100mm) spacing between adjacent Silva Cells. Adjust the extents, locations, and quantities of Silva Cells as necessary per project design parameters. Note: Where possible, we recommend connecting tree openings using Silva Cells. If adjacent to soil volumes such as lawns or parks, use Silva Cells to create an access channel for roots to grow from the tree opening to those areas. FIGURE 3-1. Laying out the Silva Cells for a circular tree opening.

B. Diamond-Shaped Tree Openings 1) Start the layout by supporting the edge of the tree opening The only differenec between rectangular/square and diamond-shaped layouts is the orientation of the tree opening. The Silva Cell layout for a diamond-shaped tree opening will still need to completely support the tree opening edge. Start your Silva Cell layout at the tree opening, rotating and adjusting the spacing of the Silva Cell blocks along the inner edge of the tree opening. It is easiest to align the Silva Cell layout geometry with one edge of the tree opening. Work outwards from the inner edge of the tree opening in a more-or-less geometric pattern, sliding the Cells along the edge of the tree opening. Keeping a standard geometry will allow you to maintain the standard 1-4 (25mm - 100mm) spacing between Silva Cells while minimizing any extension into the tree opening. 2) Work Silva Cells outward to connect tree openings Now that the support of tree opening edges has been establish (Step 3-1), you can complete the Silva Cell layout outward, potentially linking adjacent Silva Cell areas per site design, soil volume, and budget goals. Work outward from the tree openings to the extents of the Limits of Work while maintaining the typical 1-4 (25 mm - 100 mm) spacing between adjacent Silva Cells. Adjust the extents, locations, and quantities of Silva Cells as necessary per project design parameters. Note: Where possible, we recommend connecting tree openings using Silva Cells. If adjacent to soil volumes such as lawns or parks, use Silva Cells to create an access channel for roots to grow from the tree opening to those areas. FIGURE 3-2. Laying out the Silva Cells for a diamond-shaped tree opening.

DeepRoot Green Infrastructure, LLC 101 Montgomery Street, Suite 2850 San Francisco, CA 94104 www.deeproot.com info@deeproot.com Tel: 415 781 0191 Deep Root Canada Corp. Suite 341 550 West Broadway Vancouver, BC V5Z 0E9 www.deeproot.com mjames@deeproot.com Tel: 604 687 0899 DeepRoot Urban Solutions, Ltd. 43-45 Portman Square London W1H 6HN www.deeproot.com steve@deeproot.com Tel: +44 207 969 2739