Rotating Vane Anemometers



Similar documents
Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Wireless Indoor/ Outdoor Thermometer

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Installation Instructions

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

LCD5500Z / PKP-LCD v3.x Installation Instructions

TABLE OF CONTENTS 11.0 WARRANTY

Periodic Verification System Model 775PVS

Part I - Installation

Tipping Bucket Rain Gauge Models 6011-A 6011-B

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Global Water Instrumentation, Inc.

Thermistor Thermometer MODEL NO

Dual Laser InfraRed (IR) Thermometer

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Air Conditioning Systems Warranty Manual. Version 1.8

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

CA-125 Owner's Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Model SRMD Setra Remote Monitoring Display

DBF 4XL Dryer Booster Fans

Brushless Motors Instructions

Light Meter (Foot Candles)

RT-200 HI-TEST ROPE TESTER

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

VK-250 WARRANTY REGISTRATION FORM

High Temperature InfraRed Thermometer with Laser Pointer

LOS 2500 SUPER CEILING SENSOR. Installation Manual

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

ExStik TM ph Waterproof Meters

User's Guide. Integrating Sound Level Datalogger. Model Introduction

OAK WORKBENCH WITH 2 DRAWERS

03-07 Ford 6.0 Powerstroke Installation Instructions and Manual P/N: 10401

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL

BroadBand PowerShield. User Manual

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Digital Fingerprint safe

15 Digital Photo Frame Instructional Manual

Wireless Home Security System Product Manual (Model #80355)

Alarm Clock USER GUIDE

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

User's Guide Integrating Sound Level Datalogger Model

Ozone Generator Manual

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

Mini-led spotlight with magnetic base

AP IR Remote Control Installation & Operation Manual

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

FP111-FP211-FP311 Global Water Flow Probe User s Manual

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Park 250 Brushless Outrunner Instructions

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation and Operation Guide for PD4100 Series Power Control Centers

CT-001, CT-001-Solar Owner s Manual

12 Volt 30 Amp Digital Solar Charge Controller

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Table of Contents WARNING SYMBOLS AND DEFINITIONS

3 WATT LED SPOTLIGHT Model No. SLM

Universal Wireless Effects Controller USER S GUIDE SA115

Single Station Remote Alarm

IR Repeater. Operation Manual P8620

ATS Overhead Table Shelf System INSTRUCTION MANUAL

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

24.2L M.A.N. V12 Engine Module

PAPER SHREDDER PRS-F-01 USER MANUAL

Microwave Meter. Instruction Manual

AM/FM PLL Clock/Table Radio

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Compaq Presario Desktop Products. Upgrading and Servicing Guide

About this Manual. Support for Your Product

, User s Manual

Owner s Manual & Safety Instructions

MTX-D, Oil Temperature/Pressure Gauge

8 Digital Photo Frame Instructional Manual

Die-Cast Metal, Motion- Activated Post Light

SURROUNDVIEW Installation and Setup User s Guide

Installation Guide Smart-UPS X External Battery Pack SMX120BP

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Architect/Contractor Information Package

INSTRUCTION MANUAL DTH Fax: (503)

MTX-D, Boost/Shift Gauge

Dual-Cool Notebook Cooler Pad. User s Manual

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

Transcription:

OWNER S MANUAL Rotating Vane Anemometers Models RV, RVA, RVR A TSI Company

Table of Contents General Description 2 Using Rotating Vane Anemometers Safely 3 Getting Started 4 Battery Information 4 To Remove a Battery 4 Low Battery Indication 4 Metric/English Switch 5 Using the Model RV Instrument 5 Using the Model RVA or RVR Instrument 5 Velocity Mode 5 Volume Flow Rate Mode 6 General Usage Instructions 8 Checking Air Velocity or Volume Flow Rate in Small Areas 8 Checking Air Velocity or Volume Flow Rate Over Larger Areas 8 Use on Grilles 8 Use in Airways 9 Calculating Volume Flow Rate 10 Recalibration 11 Repair Information 12 Instructions for Return 13 Ownership/Calibration Log 15 1

General Description The Alnor RV series of Rotating Vane Anemometers are intended for direct measurement of air flow at diffusers, grilles, and fume hoods. Air movement causes rotation of a multi-blade fan mounted in low-friction bearings. A non-contact sensor translates fan blade movement into actual air velocity. All models are battery operated and feature LCD readout of measured parameters. Each RV instrument can be operated with one hand, using the single switch plate control on the handle. Individual model features may vary. 2

Using Rotating Vane Anemometers Safely All ordinary precautions must be observed when operating Rotating Vane Anemometers near moving equipment such as motors and blowers. Exercise care to ensure that the instrument does not interfere with any moving equipment.! WARNING The operational range of these instruments is 50 to 122 F (10 to 50 C) and must not be exceeded. Storing instruments beyond these limits may affect balance and accuracy. These instruments are NOT designed for gas mixtures other than air. Use with corrosive or other dangerous gas mixtures is not recommended and is at the user s risk. Although the sensing element is protected, it can be damaged if subjected to abuse. It is not repairable. 3

Getting Started Battery Information All models require a 9V battery (RV and RVA use NEDA type 1604, RVR uses IEC 6F22 zinc/carbon, or equivalent). The battery is not installed when the instrument is shipped. To install the battery, press firmly on the battery compartment cover and slide it in the direction of the arrow. RVR instruments require the removal of a retaining screw as shown in Figure 1. To Remove a Battery Remove the battery from the connector using a small screwdriver or similar tool. Do not disconnect it by pulling on the wires. Low Battery Indication If the battery voltage falls below a predetermined level, the display will show four zeroes on the Model RV, and bat in the top left-hand corner on the Models RVA and RVR. These models will still operate correctly, but only for a limited time. However, the Model RV battery must be replaced before further readings can be taken. Note: Do not leave a discharged battery in the instrument. Always remove the battery if the instrument is to be out of use for an extended period of time. Figure 1: Battery compartment detail Metric/English Switch Optional Retaining Screw 4

Metric/English Switch (Models RVA and RVR only) The instrument can display readings in either metric or English units. The metric/english switch is in the battery compartment (see Figure 1). When the switch position is changed, any value in the memory will be converted from metric to English or vice versa. Using the Model RV Instrument Hold the rotating vane in the airstream noting the direction-of-flow arrow on the head of the instrument. Keep the vane in the airstream about five seconds to enable it to reach steady speed. Press and hold down the switch plate. After a period of three seconds (metric model) or six seconds (English model), an average velocity over this period of time will be displayed. The reading will remain displayed until the switch plate is released. Repeat this process to take a new average reading. Note: Do not touch the fan blades within the anemometer ring while reading, as this may cause errors. Using the Model RVA or RVR Instrument Velocity Mode Switch on the instrument to VEL using the slide switch below the display. Hold the rotating vane in the airstream according to the direction of the flow arrow on the side of the instrument. Keep the vane in the airstream about five seconds to enable it to reach a steady speed. 5

The instrument may then be used in either of two modes: 1. A momentary push on the switch plate will display the average velocity over about a two-second period. 2. Pushing and holding the switch plate will display the average velocity over the period of time it is depressed. During this time the instrument is programmed to display the current average reading about every two seconds. Volume Flow Rate Mode Before switching on the instrument, determine the effective cross-sectional area of the duct, grille, etc. for which the volume flow rate is required. Consult the manufacturer s data for the outlet in use. Switch on the instrument to +area and observe the area figure displayed from the memory. If the new area required is larger, remain in the + position and press the switch plate to increase the displayed area to the calculated figure. If the area is less than the figure displayed, move the slide switch to the area position and press the switch plate to reduce the displayed area to the calculated figure. When the correct area is displayed, move the slide switch to Vol. Note: If working in metric units, calculations must be in m 2. If working in English units, calculations must be in ft 2. The last area value will be retained in the memory even when the instrument is switched off. If the battery is removed, the area value will be reset to 1.000 m 2 or 1.000 ft 2. 6

The instrument may then be used in either of two modes: 1. A momentary push on the switch plate will display the average volume flow rate over about a two-second period. 2. Pushing and holding the switch plate will display the average volume flow rate over the period that it is depressed. During this time, the instrument is programmed to display the current average reading about every two seconds. If the instrument is used in this mode for long time periods, the memory will become full after about 12 minutes and the display will indicate full. The last valid reading will be displayed when the switch plate is released. This reading will continue to be displayed until the instrument is switched off. This erases the memory, extinguishes the display, and makes the instrument ready for use again. Note: If the instrument is used in higher velocities than its specified range, VEL HI will appear on the display. Do not touch the fan blades within the anemometer ring while using the instrument as this may cause errors. 7

General Usage Instructions Checking Air Velocity or Volume Flow Rate in Small Areas The instruments will function satisfactorily in any angular position but should not be used in airstreams which are smaller than the entire face area of the measuring head (113 mm or 4.5 in. diameter). The instruments are calibrated for use in free air conditions. For smaller airstreams, the Alnor CompuFlow anemometers are recommended. Checking Air Velocity or Volume Flow Rate Over Larger Areas When checking air velocity or volume flow rate over larger areas, a number of spot readings should be taken and recorded as described in Velocity Mode or Volume Flow Rate Mode to give coverage over the whole area. When taking spot readings, it should be noted that large variations may be observed between individual readings. In general, the more readings taken, the more accurate the result will be. It does not matter if the positions of the readings overlap somewhat, so long as they are equally spread to cover the entire area. Alternatively, the RVA or RVR will provide the mathematical average automatically when steadily scanned across the whole area, if used as described in Velocity Mode or Volume Flow Rate Mode. Use on Grilles Note: See comments under Possible Error Sources. 8

Avoid intrusion of the hand, arm, or handle of the instrument into the face area of the grille. The blockage effect created by this would cause artificially high velocity over the remainder of the grille, leading to additional errors. Better measuring conditions can be obtained on grilles with adjustable direction vanes if the vanes on the grilles are temporarily straightened before making measurements. This should not significantly affect the flow rate as long as any built-in dampers are not accidentally disturbed. It is advisable to use the aperture, not the surface area of the grill, in any flow rate calculations. The instruments are suitable for both supply and exhaust grilles, and the procedure for both is the same except that the direction arrow on the measuring head must be aligned correctly. While it is acceptable to hold the anemometer head against the grille on exhaust, it is usually better to hold it slightly away from the grille face on supply to avoid excessive turbulence and any vena-contracta effects. Use in Airways In large airways, the presence of the instrument will have a negligible effect, but in small airways the blockage caused by the instrument, hand and arm will force the airstream to accelerate slightly as it passes the rotating vane. This effect is somewhat variable depending on the size of the airway and the distance from the duct walls. The error can be virtually eliminated by mathematical correction to allow for the reduction of free area caused by the obstruction. For this purpose the effective front area of the instrument (not including hand or arm) can be taken as 0.019 m 2 (0.204 ft 2 ). The effect can be ignored completely if the duct exceeds about 500 mm diameter (1'9"). 9

Calculating Volume Flow Rate Volume flow rate through airways or apertures may be calculated if the cross-sectional area of the airstream and its average velocity are known. To arrive at volume flow rate, the cross-sectional area of the airstream is multiplied by the average airstream velocity, using the same units of linear measurement throughout the calculation. Example: A rectangular duct measures 600 mm x 400 mm and twelve readings of velocity have been taken, as shown in the diagram below. The readings are added together and the result is divided by the numbers of readings to give an average velocity for the whole duct. In this example, the average velocity is 3.025 meters per second. 2.5 2.9 3.1 3.0 2.9 3.1 3.3 3.1 400 mm 3.0 3.2 3.2 3.0 600 mm The duct cross-sectional area is: 0.600 x 0.400 = 0.240 meters 2, therefore, the volume flow rate is 0.240 x 3.025 = 0.726 cubic meters per second. This figure should be multiplied by 3600 to arrive at cubic meters per hour, or by 1000 to give the answer in liters per second. 0.726 x 3600 = 2613.6 m 3 /h or 0.726 x 1000 = 726 liters/s. The procedure is the same when working in English units, but the velocity readings will be in ft/min. The duct area should be calculated in square feet, and the answer will be in cubic ft/min. 10

Recalibration If an instrument s calibration becomes suspect because of accidental mishandling, it should be returned to Alnor for recalibration to original standards. It is recommended that the instrument be checked/calibrated at least once a year. 11

Repair Information Contact the distributor in your country, or Alnor Instrument Company directly, before returning your instrument. See INSTRUCTIONS FOR RETURN. Follow the procedure carefully as it will expedite processing. Failure to follow the procedure may cause return of the unit unrepaired. Send your instrument to Alnor transportation prepaid. To assure fast turn-around time, photocopy and fill out this form with as much detail as possible and attach it to the instrument. RMA Number Instrument Model Serial Number Date of Purchase Where Purchased Describe Malfunction Describe Environment Return Instrument to: Name Company Address Telephone Address Correspondence to: Name Company Address Telephone 12

Instructions for Return Damaged in Transit All shipments are examined by Alnor s Service Department and carefully packed for shipment. On receipt, if the shipping container appears to have been damaged during shipment, the instrument should be thoroughly inspected. The delivering carrier s papers should be signed noting the apparent damage. If the instrument itself has been damaged, a claim should be promptly filed against the carrier by the customer. The selling agent will assist the customer by supplying all pertinent shipping information; however, the claim must be filed by the insured. If the instrument is damaged beyond use, a new order should be placed with Alnor while awaiting reimbursement from the carrier for the damaged instrument. Call Alnor directly for assistance if necessary. Repair/Calibration Please follow these steps should you require factory service or repair of your Alnor instrument: 1. Contact the Alnor distributor in your country for the cost of repair or recalibration and shipping instructions. Obtain a purchase order number from your Purchasing Department showing instrument model number and cost of repair and/or recalibration. Securely package your instrument in a strong container surrounded by at least two inches (5 cm) of suitable shock-absorbing material. Reference the purchase order number on your packing slip. Forward the instrument prepaid. See back cover for address. OR 2. Contact the Service Department at Alnor for the cost of repair or recalibration, Return Material Authorization (RMA) number, and 13

shipping instructions. For instruments being returned to the factory for recalibration, determine whether you prefer: Certificate of Calibration, no data (states instrument checked and found to be within accuracy claimed and specifications listed in current literature). Certificate of Traceability to National Institute of Standards and Technology (NIST, formerly NBS) with data (states instrument compared with factory standard traceable to NIST, lists of calibration data, i.e., Standards reads... and This instrument reads... ) Obtain a purchase order number from your Purchasing Department showing instrument model number and cost of repair and/or recalibration. Securely package your instrument in a strong container surrounded by at least two inches (5 cm) of suitable shockabsorbing material. Reference the purchase order number on your packing slip. Mark the outside of the shipping container with the RMA number. Forward the instrument prepaid. See back cover for address. Please note that instruments received improperly marked or without an accompanying purchase order may be returned at your expense. Please also note that if an RMA number has been assigned, it will be canceled if the instrument is not received by Alnor within 60 days. 14

Ownership/Calibration Log Equipment Log Date of Purchase Calibration Record 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Notes: 15

Warranty Alnor Instrument Company (Alnor) warrants this product to be free of defects in material and workmanship for a period of one year from the date of original purchase. If the product should become defective during the warranty period, Alnor will repair it or elect to replace it free of charge under the following conditions: 1. Product is returned postpaid per the instructions for return, located in the owner s manual. 2. Owner submits proof of original date of purchase. 3. Alnor will inspect product for defects in material and workmanship. Alnor s decision as to existence of defect, and in the case of defect, to repair or replace will be final. THIS WARRANTY IS EXCLUSIVE. THERE ARE NO OTHER WARRANTIES EITHER EXPRESSED OR IM- PLIED. SPECIFICALLY AND WITHOUT LIMITATION, THERE IS NO WARRANTY, EXPRESSED OR IMPLIED, OF MERCHANTABILITY OR FITNESS FOR PARTICU- LAR PURPOSE. This warranty is void if product is misused, used contrary to procedures set forth in the owner s manual, or if product is serviced by anyone other than Alnor s authorized service. This warranty does not cover consumables such as light bulbs, paper, batteries, etc. Alnor s liability for this product is limited to the above stated warranty and shall not in any event exceed the cost of the product. In no event will Alnor be liable for any direct or consequential damages, including but not limited to lost profits, loss of use, inaccuracies, loss of data, dismantling or reinstallation. 16 ALNOR INSTRUMENT COMPANY 7555 North Linder Avenue Skokie, Illinois, 60077 USA February 1998 Toll-Free (800) 424-7427 Printed in USA Telephone (847) 677-3500 Part No. 116-159-201 Rev. 2 Fax (847) 677-3539 Copyright 1997 Alnor Instrument Company