Trace Humidity Monitoring up to -90 C td



Similar documents
testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Duct Humidity Transmitter

testo 6383 Ethernet differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

Measurement data monitoring system

testo 6383 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

Pressure Dew Point Probe / Application Information

testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2

ThermoSorb Desiccant Dryers

Instruction Manual. T3111 T3111L T3111P T3111Ex

testo 6681 Humidity transmitters testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Dew-Point Measurement Solutions

clean and quiet dental

Committing to the future. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

Online Infrared Flue Gas Analyzer Gasboard 3000

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PRODUCT PROFILE FEATURES

COMBIMASS. Technical Data COMBIMASS eco-bio +

API Marine. BMS Presentation. Ballast Measurement Systems

Adsorption air dryers ADS 1 215

Centro-Matic Automatic Lubrication Systems System Controls

How To Use A Ds340 (Dsp)

Multifunction HVAC and IAQ Meter

testo 6381 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Kompressoren. Adsorption Dryer AD

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

4 Posiflow Proportional Solenoid Valves

How is Dew Point Measured Reliably?

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Battery Powered Thermal Mass Flow Meters for Gases

Models SFP33 & SFP32 Pressure Transmitters

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Series DFMT Digital Paddlewheel Flowmeter

Rotary screw compressors kw 5,5 7, , bar MODULO

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Measurement data monitoring system testo Saveris.

Vacuum drying oven for non-flammable solvents

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Temperature & Humidity SMS Alert Controller

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Measurement data monitoring system testo Saveris.

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Basic Hydraulics and Pneumatics

Digital inductive conductivity transmitter

Electronic Control Devices The European Product Catalogue 2007

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Refrigeration Compressed Air Dryer Buran Ultrapulse

Pressure transmitter For general industrial applications Model A-10

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 4 v2.2 / Modification rights reserved EE210

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Measurement Solutions for Refrigeration Technology.

Proportional pressure regulators VPPE

Electronic Flow Switches

Turbine Flow Sensor Series VTR

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Multi-Range Programmable DC Power Supplies 9115 Series

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Electronic Pressure Switch EDS 3000

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

REGTRONIC OPERATING INSTRUCTIONS

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Liquid Level Limit Switch liquiphant T FTL 20

USB-500 Series Stand-Alone, Low-Cost Data Loggers

MP-4000 Alarm List (Software version or later)

Rense Product Range. Customized Humidity Solutions. Rense Product Range

Micro Motion 3098 Gas Specific Gravity Meter

PAJ GROUP DEVELOPMENT OF ADVANCED MECHATRONICS

T0118 T2118 T3118. Instruction Manual

S300 Series Dust Monitors

Thermal Mass Flow Meter (Series MST)

PIEZOMETER AIRFLOW MEASURING RING

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Membrane air dryers MS-LDM1, MS series

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

In-Line Electronic Flow Switches

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Refrigerated Air Dryers. Catalogue

Contents. Document information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Battery Powered Thermal Mass Flow Meters for Gases

Electronic Control Devices The European Product Catalogue 2007

Plastic tube flowmeters Series PT/PS

For Multi-Parameter Meters see mvx

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Material test chamber with mechanical convection

Transcription:

Committing to the future Trace Humidity Monitoring up to -90 C td New, condensation-proof sensor with sol-gel technology

Highest compressed air quality requirements Monitor trace humidity, avoid damage Air, compressed air and gases are used in all areas of industry. Humidity is normally undesirable because it can cause damage or impair the quality of the end product, as the adjacent graphic shows. Optimizing the regulation of adsorption dryers The regeneration cycle can be reduced by controlling the parameter trace humidity ( C td ). That saves energy costs! Manufacture Distribution Consumer Compressor >> Dryer Corrosion in pipes and components Pneumatic drives: Interrupted lubrication Mechanical damage Formation of ice in outside and low- Trace humidity monitoring with avoids follow-on damage caused by humidity e.g. transport air for pharma. powder e.g. medical compressed air Damp powder sticks together Bacterial growth (European drug legislation) What is compressed air quality? The international standard ISO 8573 defines seven classes of compressed air quality and defines the humidity, the oil content, the particle content etc. which the compressed air is allowed to have. Class 1 represents the highest requirements. Class 2, for example, is fulfilled when the pressure dewpoint does not exceed -40 C td or -40 F td, or an absolute humidity of 0.12 g of water vapour per m 3 or 18 ppm V (parts per million by volume) (see table on right). The main way of ensuring compliance with a quality class involves installing a suitable dryer e. adsorption dryer). Its monitoring and, where appropriate, its control, is handled by the. ISO 8573 Class 1 2 3 4 5 6-70 -40-20 3 7 10 Trace humidity C td F td g/m 3 ppm v (at 7 bar) -94-40 -4 37 44 50 0,003 0,12 0,88 5,51 7,28 8,93 0,37 18 147 1083 1432 1756 Typical application Semi-conductor prod. Granule dryer Transport air Working/energy air 7 Blow air Action Monitoring/controlling Compressed air drying Applications in the monitoring of compressed air quality 2 Compressed air systems: dryer monitoring to avoid damage caused by humidity Medical compressed air: minimum humidity as a hygiene requirement Granulate drying: dry air is a requirement for product quality Gas engineering: humidity causes damage and reduces the value of the gas in the system

Pressure dewpoint transmitter up to -90 C td Measurement of dewpoints in the measuring range -90 to +30 C td New, very condensation-proof sensor with sol-gel technology guarantees highest process security and fast response Display with multi-language user menu. Atomatic self-adjustment ensures high accuracy and long reliability Self-monitoring guarantees high systam availability The P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance Areas of application: Pressure dewpoint measurement in the ISO Classes 1 (<-70 C td ) and 2 (<-40 C td ) Monitoring of adsorbtion dryers, granulate dryers and medical compressed air Quality assurance for noble gas preparation Configuration options for the Axx Process connection Bxx Analog display/supply Cxx Display Fxx Humidity parameter / min limit value / max-limit value / hysteresis (pre-set) Kxx IM languages (for bilingual printed IMs) Mxx Protective filter Order no. 0555 6781 A01 Bxx Cxx Fxx Kxx Mxx A01 A02 B02 B03 B04 B05 B06 C00 C02 C03 C04 C05 C06 C07 C08 Process connection G1/2 Process connection NPT 1/2 0 to 1 V (4-wire, 24 VAC/DC) 0 to 5 V (4-wire, 24 VAC/DC) 0 to 10 V (4-wire, 24 VAC/DC) 0 to 20 ma (4-wire, 24 VAC/DC) 4 to 20 ma (4-wire, 24 VAC/DC) without display with display/english with display/german with display/french with display/spanish with display/italian with display/japanese with display / Swedish F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 F11 K01 K02 K03 K04 K05 K06 K07 K08 C td F td % RH/Min/Max %RH C tda F tda ppmv g/m³ g/ft³ g/kg g/lb German/English instruction manual French/English instruction manual Spanish/English instruction manual Italian/English instruction manual Dutch/English instruction manual Japanese/English instruction manual Chinese/English instruction manual Swedish/English instruction manual This results in a typical ordering code: 0555 6781 AXX BXX CXX FXX KXX MXX M01 M03 Sintered stainless steel cap Sintered PTFE filter 3

Pressure dewpoint transmitter up to -90 C td Technical data Parameters Humidity/trace humidity Units Calculated variables * Determination measurement inaccuracy according to GUM GUM (Guide to the Expression of Uncertainty in Measurement): ISO guideline for the determination of measurement inaccuracy, in order to make measurements comparable worldwide. The following inaccuracies are used for the determination: - Hysteresis - Linearity - Reproducibility Measuring range Measurement uncertainty* Response time Autom. self-adjustment This total view results in an additional dewpoint-dependent and process-dependent inaccuracy contribution of ±0.03 K x measurement value (in Ctd) + 0.2 K x (25 C - process temperature in C). Outside the stated measuring range, a measurement inaccuracy of ±5 K applies (typically). Inputs/outputs Analog outputs Current/accuracy - Adjustment site/factory calibration - Test site C td, F td, %rf, %RH C tda, F tda (normed atmosph. dewpoint), ppmv, g/m³, g/ft³, g/kg, g/lb -90 to 30 Ctd / -130 to 86 Ftd -20 C td to -40 C td : ±1,5K -40 C td to -60 C td : ±2K -60 C td to -75 C td : ±2,5K t63 3s for switch from -75 C td to -30 C td t90 9s for switch from -75 C td to -30 C td t63 300s for switch from -30 C td to -75 C td t90 1080s for switch from -30 C td to -75 C td Cycle adjustable: 1 h / 6 h / 12 h / 24 h 0 to 20 ma ±0.03 ma (4-wire) 4 to 20 ma ± 0.03 ma (4-wire) General technical data Model Material Dimensions Weight Display Without display With display Display Resolution Operating conditions Metal housing 208 x 60 x 35 mm 0.5 kg optional: 2-line LCD with multi-language operating menu Measuring range Resolution 0 to +100 %RH 0,001 0,001 to 28 g/kg 0,001 0,01 to 194 g/lb 0,01 0 to 31 g/m3 0,001 0,001 to 14 g/ft3 0,001 1 to 42500 ppm(v) 1-90 to +30 Ctd 0,1-130 to +86 Ftd 0,1-110 to +30 CtdA 0,1-165 to +86 FtdA 0,1-40 to +70 C 0,01-40 to +158 F 0,01 Miscellaneous Protection class IP 65 EMC EU guideline 2004/108/EC Process temperature -40 to +70 C / -40 to +158 F Process pressure max. 50 bar Operation temperature -40 to +70 C / -40 to +158 F Storage temperature -40 to +80 C / -40 to +176 F Operation temperature -20 to +80 C / -4 to +176 F Storage temperature 0 to +50 C / +32 to +122 F Output type Meas. cycle Resolution Load Other outputs Digital Supply Voltage supply 0 to 1 V ±1.5 mv (4-wire) 0 to 5 V ± 7.5 mv (4-wire) 0 to 10 V ±15 mv (4-wire) 1/sec 12 bit max. 500 Ω Mini-DIN for P2A software 20 to 30 VAC/DC, 300 ma current consumption, galvanically separate signal and supply line 4

Accessories tailored to every application Accessories for Order no. Precision measurement chamber up to 35 bar (ideal for lowest humidity) for optimum flow impact onto sensor with freely adjustable flow valve Pre-setting of valve: 1 l/min at 7 bar 0554 3312 Flow-through gauge for precision measurement chamber for adjusting specific flow impact onto sensor when process pressure deviates from pre-setting of flow valve 0554 3313 2 m PTFE hose with compressed air connections up to +140 C / +284 F (max. 9 bar / 130psi), only with measurement chamber (only up to -60 C td ) 0699 2824/4 Preliminary filter to protect measurement chamber and sensors against contamination 0554 3311 Cooling coil for process temperatures higher than 50 C (up to 200 C), only with measurement chamber 0554 3304 Mains unit (desktop instrument) 110 to 240 VAC/24 VDC (350 ma) 0554 1748 Mains unit (top-hat rail mounting) 90 to 264 VAC/24 VDC (2.5 A) 0554 1749 Process display testo 54-2 AC, two relay outputs (to 250 VAC / 300 VDC, 3A), mains supply 90 to 230 VAC 5400 7553 Process display testo 54-7 AC, two relay outputs (to 250 VAC / 300 VDC, 3 A), mains supply 90 to 260 VAC, with RS485 output for online monitoring and with totalizer display 54007555 Certificates ISO calibration certificate, two adjustment points -10/-40 C tpd at 6 bar 0520 0136 Humidity ISO calibration certificate, pressure dewpoint measuring instruments, freely selectable calibration points 0520 0116 from -40 to 0 C tpd at 6 bar (-40 to 32 F tpd ) at 87 psi Selection assistance for applications A Use of precision measurement chamber for clean air and when process pressure corresponds to pre-setting B Flow-through gauge is additionally used when air is clean and process pressure deviates from pre-setting of precision measurement chamber (1 to 35 bar) C D Pre-filter is additionally used for contaminated air and when process pressure corresponds to pre-setting of precision measurement chamber For dry air (e.g. granulate dryers, max. 140 C), a PTFE tube is additionally used and the valve of the measuring chamber is opened fully (suitable up to -60 C td ). G ½- thread E The cooling coil is additionally used for process temperatures >50 C (to 200 C) and process pressure corresponding to the pre-setting NPT ½ -thread 5

Optimizing processes and saving time in commissioning and maintenance On-site adjustment The Testo transmitters are delivered ready to use. For professional application, the following functions are available via the easy-to-use software Parameterization of unit and scale Sensor adjustment (1-point) and adjustment of the analog outputs Parameterization and adjustment history of all activities of the P2A software are registered in the PC P2A software = P aramerization A djustment A nalysis P2A software A selected working point can be easily adjusted by manually entering a reference value. Just a few operatring steps are sufficient in the P2A software to carry out the adjustment. Conclusion: Saved time and lower operating costs! Using the P2A software, unit and scale can be easily parameterized, for example. Integrate the into testo Saveris TM The measurement data monitoring system measures temperature and humidity values in the environment and in processes. In industrial processes, exact temperatures, humidity values and pressure relationships play a crucial role. In a multitude of applications, testo Saveris helps to collect, safely store and present these data wirelessly or via Ethernet. A selection of alarms that can be used flexibly supports the responsible parties to keep the values in the required range. find out more at: www.testo.com/saveris Now new: Integrate the into testo Saveris TM using the testo Saveris analog coupler Integration of transmitters for all measurement parameters with standardized current and voltage interfaces, e. g. 4 to 20 ma, 0 to 10 V testo Saveris analog coupler available as a wireless or Ethernet version 0981 6284/msp/R/Q/02.2010 Subject to change without notice.