Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL48PM



Similar documents
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Meaco 30L and Meaco 40L dehumidifier instruction manual

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Portable Air Conditioner

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Use and Care Manual. Model CPA12KH AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER

Dehumidifier Users manual. For Models: DH45S DH65S

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

PORTABLE AIR CONDITIONER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

PORTABLE AIR CONDITIONER

Important Safeguards

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

INSTRUCTION MANUAL. Manufactured for: Phoenix Manufacturing Inc. 90% Less energy consumption

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Instruction manual for Firstline FCS12000CH

Get Me Cool Now Portable Air Conditioner User s Manual

Operating Instructions Split System Air Conditioner

15GAL STEEL OIL DRAIN WITH 110V PUMP

Operating Instructions Air Conditioner

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

VACUUM CLEANER INSTRUCTION MANUAL

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Split Type Room Air Conditioner. KSWM units

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SWIMMING POOL HEAT PUMP

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

OWNER S MANUAL HH200M 6.12

2KW CERAMIC HEATER DHCER20. User Manual

CARING FOR YOUR WATER HEATER

PORTABLE AIR CONDITIONER (LOCAL)

Taurus Series YORK Window Air Conditioners

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

USER S MANUAL HSC-24A

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Dehumidifier D 850E. - Instruction manual version 02

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

HYLA NST Cleaning System

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Carpet Washer. vax.co.uk. Rapide Ultra series

Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

OPERATION MANUAL OFFICE PRO 18 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.

Digital Photo Picture Frame. Operation Manual

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

Safety, Operation and Maintenance Manual with Parts List

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

LG Room Air Conditioner OWNER'S MANUAL

Read This First! OWNER S GUIDE

2-SLICE COOL TOUCH TOASTER

GenStore Archive Cabinet

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Room Air Conditioners

3000W Power Inverter

W850. Maintenance Guide

Carpet Shampooer 500w

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Operating Instructions Air Conditioner

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

AIR CONDITIONER (SPLIT TYPE)

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

rainbowsystem.com Rexair LLC Troy, Michigan 2011 Rexair LLC R14388A-0 Printed in U.S.A.

Reverse Cycle Inverter Split System Air Conditioner

Room Air Conditioners

Transcription:

Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL48PM Power rating: 130 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C.

QUICK START GUIDE Fill with water and plug into a standard power outlet. Note: Please make sure the household power voltage matches the product specifications. Place near an open door or window. Note : Evaporative air cooler requires cross ventilation. Turn ON and enjoy the cooling breeze. Note: Start with LOW speed and gradually increase to higher speed for optimum cooling performance.

INDEX Read all instructions carefully before setting up and operating the cooler, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. SECTION PAGE THANK YOU... 2 USER TIPS... 3 SAFETY... 5 PARTS DESCRIPTION... 7 USE & OPERATION... 8 Control Panel... 8 Control Knobs... 9 Filling Water... 10 CLEANING & MAINTENANCE... 12 TROUBLESHOOTING GUIDE... 14 TECHNICAL SPECIFICATIONS... 15 ELECTRICAL WIRING DIAGRAM... 15 SERVICE AND WARRANTY... 16 1

THANK YOU Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling from your cooler, fill the water tank to maximum level and load ice inside the ice compartment before you turn on your air cooler. Cooler Location (Important - Please Read!) Place the cooler in front of an open door or window. Ensure that there is adequate cross - ventilation in the room by leaving a door or window open opposite the cooler. Following these guideline will ensure your cooler will work as effectively as possible. Not an Air Conditioner (Important - Please Read!) The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner. 2

USER TIPS Energy efficient, No compressor Honeywell Evaporative Air Coolers are built to maximize energy efficiency and keep costs low. Warm air is drawn into the cooler through a dust and odor-reducing carbon filter and enters the Honeycomb Cooling Media. Water pumped from the tank pours over the honeycomb media. As the warm air passes through the media, the water absorbs the heat, naturally cooling and humidifying the air. A fan propels the cooled air out into the room. This no-compressor system cools naturally, efficiently and inexpensively. Honeycomb Cooling Media Warm and dry air Cool and humid air Pump Water Evaporative Air Cooling Mechanism 3

USER TIPS The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low. The evaporative air cooler should not be used in enclosed spaces. It must be kept level and there must be water in the water tank. The room should have doors and windows opened to allow free air flow. The evaporative air cooler works best when placed near an open window, so that outside air is drawn into the evaporative air cooler, the air circulates in the room, then exits via the door. The maximum cooling effect is felt when a person is in the flow of air coming out of the evaporative air cooler. The evaporative air cooler can also be used to humidify dry air during cool weather. To be used for humidification the windows and doors should be closed to allow the humidified air to accumulate. Room with open windows & door (RECOMMENDED) Room with closed windows & door (NOT-RECOMMENDED) NOTE When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a week or so of initial use. 4

SAFETY READ AND SAVE THESE INSTRUCTIONS: When using electrical appliances, basic safety precautions should always be followed: Your cooler runs on 230 Volt AC, 50 Hz current. Check the household voltage to ensure it matches the appliance's rate specification. Before operating the product remove it from its packaging and check that it is in good condition. DO NOT operate any product with a damaged cord or plug. We recommend not using an extension cord with this appliance. DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from areas where it may be tripped over. Always unplug the product before refilling the water tank. Always unplug the appliance from the power source before cleaning, servicing or relocating the unit. Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug-end only, never pull the cord. DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are stored. When using the ''COOL'' setting, check the water tank to ensure that it is full. Operation of this cooler on the ''COOL'' setting with an empty tank may result in damage to the water pump. 230 Volt AC 50Hz SHOCK HAZARD WATER LEVEL INDICATOR 5

SAFETY DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler, as this may void the warranty. DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage. DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire. DO NOT operate with the Honeycomb media removed as this will overload and damage the motor. DO NOT leave the operating appliance unattended for any extended period of time. DO NOT let children play with this appliance, packaging or plastic bags. If the unit is damaged or it malfunctions, do not continue to operate it. Refer to the troubleshooting section and seek professional advice. Place the unit on a level floor. This product is not intended for use in wet or damp locations. DO NOT use in bathrooms. Never locate the product where it may fall into a bathtub or other water container. Store in a dry area when not in use. This appliance is not intended for use by persons (including children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Always grip the side handles to move the cooler. FLOOR LEVEL 6

PARTS DESCRIPTION 16 9 1 2 14 13 10 8 15 3 4 11 5 6 12 7 1 Manual Water / Ice Inlet 2 Handle 3 Left Honeycomb Panel 4 Lever for Horizontal Louvers 5 Water Tank 6 Casters 7 Horizontal Louvers 8 Water Level Indicator 9 Mechanical Control Panel 10 Right Honeycomb Panel 11 Continuous Water Inlet 12 Water Drain Plug 13 Back Honeycomb Panel 14 Power Cord & Plug 15 Rear Grill Removal Screws 16 Water Fill Door 7

USE & OPERATION CONTROL PANEL NOTE: Speed control may be marked as High / Med / Low in certain units. 8

USE & OPERATION CONTROL KNOBS SPEED / ON - OFF Connect to the power supply and turn the SPEED knob. The fan will start. Change the speed from 1 for Low to 2 for Medium to 3 for High. To switch the unit OFF, turn the SPEED to 0. COOL Turn the COOL knob to ON to start the cooling. It takes a few minutes to obtain the full effect from this mode. 0 3 SPEED OFF 2 1 ON SWING Vertical Louvers Turn the SWING knob to 'ON'. The louvers will begin to move from right to left automatically. HORIZONTAL LOUVERS Manually adjust the horizontal louvers to change vertical airflow. COOL OFF SWING ON 9

USE & OPERATION CAUTION Unplug from power when refilling. FILLING WATER Water can be filled into the air cooler by: Water / Ice compartment (Manual Refill) Water / ice can be put into the tank though the top opening. There is a hole for water to flow into the tank. Continuous water supply (Auto Refill) Connect a garden hose to the continuous water supply inlet. FILLING WATER ( MANUALLY) To refill the water tank, pull out the Water/Ice Fill Door located on the top side of your cooler (refer to page 7) and fill water till the Max, as indicated on the Water Level Indicator. Do not fill water above the Max water level mark. For better cooling performance, we suggest putting ice cubes inside the ice compartment located on the top side of your cooler (refer to page 7). 10 Water Inlet Water Fill Door Ice Loading Compartment

USE & OPERATION FILLING WATER (CONTINUOUS WATER SUPPLY CONNECTION) Connect water pipe to the continuous water supply connector located on the lower left side panel. Secure the connector with the pipe so that there is no leakage and turn on the water supply. With the help of the water auto-refill mechanism, water inside the tank will refill automatically. Everytime the water comes below the minimum level, the water float valve will detect it and will start the water flow inside the tank. In the same way it also stops water in-flow when reaching the maximum level. This is an automated process and will not require you to refill the water tank manually. Plug the unit into the power supply and turn the unit on. INSTALLING HOSE ADAPTER AND FLOAT VALVE Connect the garden hose Connector and turn on the water. Verify water tight connections by visually examining both the float/hose connections. Hose Connector 11

CLEANING & MAINTENANCE IMPORTANT The cooler is supplied with Honeycomb Cooling Media. The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water reservoir and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs. fresh water if the water has been standing in the tank for an extended period of time. cool function 15 minutes before turning the unit off. Do not run the unit in COOL mode with stale water in the tank. Empty the tank and refill it with For best results, allow the Honeycomb Cooling Media to dry after each use by turning off the Draining the water reservoir and refilling with fresh water at least once a week will greatly reduce mineral deposits in the pads and help to extend the life of Honeycomb Cooling Media. WARNING Before cleaning the unit, switch it to the ''off'' position and remove the plug from the power socket. To clean the outside, use a damp cloth to remove dirt and dust. Never use corrosive elements or any chemicals to clean this product. When the product is not in use, store the unit in a dry place out of direct sunlight. 12

CLEANING & MAINTENANCE DRAINING AND CLEANING THE WATER TANK Turn the power off and disconnect the air cooler from the power supply. Move the unit to a location where it can be drained. Remove the cap from the water drain plug and allow the tank to empty (see parts description on page 7). After you have drained the water tank, please connect the water drain plug to its original position. Now refill the water tank up to Max level, wait for 5 min. and then drain the entire water once again. Use clean water for this procedure, so that maximum dust particles and remains are completely removed. If your cooler has not been used for a long duration, we advise you to clean the water tank at least 2 times before it is used again. CLEANING THE FILTER AND HONEYCOMB Turn off the unit, and unplug the power cord from wall outlet. Rotate the unit facing the back panel, and locate the Rear Grill Removal Screws (refer page 7., #15). Remove both the screws with a screw driver. Pull the rear grill panel upwards, until it is completely removed. Now, the carbon filter and Honeycomb Media can be seen. Clean both the filters with a clean cloth to remove all the dust & dirt particles. Once the cleaning has been completed, assemble the unit as described above. Plug into the power supply and turn on unit. Water Drain Plug Open Screws 13

TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION No discharge of air Cord is not plugged in. Make sure power cord is plugged in and the supply switch is on. Not Cooling / Unit is making noise Power is not on. Pump is not turned ON. Low or no water in tank, when COOL is selected. Damaged Pump or Calcium deposits on blower. Turn the unit ON by pressing buttons on the control panel. On Control Panel, Turn COOL FUNCTION to ON. Refill water tank. Contact service center. Odor omission When the Cooler is new. When the unit is used for the first time, the Honeycomb Cooling Media will have an odor, which will dissipate within a week of initial use. If the Cooler has been used. There may be an algae issue, Replace the Honeycomb Cooling Media. Contact service center. 14

TECHNICAL SPECIFICATIONS MODEL NO. Voltage Frequency Wattage Water Tank Capacity Cooling Media Product Dimension Net Weight CL48PM 230V 50Hz 130 Watts 40 Litre Honeycomb 600 (L) x 490 (W) x 830 (H) 13.3 Kg ELECTRICAL WIRING DIAGRAM 15

: 2012 AirTek International Corporation Limited The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product. Manufactured by AirTek International Corporation Limited.