PCRHK0664. Split Type Air Conditioners FTXR-E Series With DC Inverter Power Control Heat Pump [50 Hz] GOOD DESIGN AWARD IN JAPAN



Similar documents
RKS25G RKS35G RKS50G RKS60G RKS71H PCRSG0708B

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

FTXS. Wall Mount Heat Pump or Cooling Only

FHQ. Ceiling Suspended Heat Pump or Cooling Only

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

FCQ. Roundflow Cassette Heat Pump or Cooling Only

FTQ. Daikin Inverter Ducted Heat Pump

FBQ. DC Duct Heat Pump or Cooling Only

york air-conditioning products Residential & VRF News 2015

Ururu Sarara. The best of the best

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Samsung Room Air Conditioning

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

USER S MANUAL HSC-24A

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

emura Form. redefined.

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Instruction manual for Firstline FCS12000CH

All the best brands all under one roof

Split Type Room Air Conditioner. KSWM units

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

DUCTED AIR CONDITIONING SOLUTIONS

Operating Instructions Split System Air Conditioner

Unico Inverter. Unique and efficient.

PCRNZ0710H. the. ultimate. heat pump air conditioning guide

Operating Instructions Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Inverter Air Conditioning for Light Commercial Use

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

Operating Instructions Air Conditioner

Portable Air Conditioner

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

ECO-AIR AIR CONDITIONING

Celxia. a s. Artcool uses state-of-the art technology to assure customer satisfaction.

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Happiness starts at home.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

PORTABLE AIR CONDITIONER

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

SiUS Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Important Safeguards

HEAT PUMPS PCSPNZ0516 HEATING & COOLING SOLUTIONS

Ducted and Duct-Free Cooling and Heating Solutions for all your Construction Needs R-410A INVERTER

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

2014 Performance RAK-PPA/PPB. 19th December 2013 RAC Product Planning Division

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

AIR-CONDITIONER SPLIT TYPE

LG Wireless Remote Controller

Technology that works fast. Hi-Wall Split Systems

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

PORTABLE AIR CONDITIONER

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

DUCT TYPE AIR CONDITIONER

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

Split Air Conditioner

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

FULL DC INVERTER SYSTEMS

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

Use and Care Manual. Model CPA12KH AIR CONDITIONER

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX

Room Air Conditioners

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Air Conditioners Technical Data

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

R410A SPLIT SERIES DC INVERTER

WINDOW ROOM AIR CONDITIONER

USER S INFORMATION MANUAL

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

air conditioners how to choose a cooling system

Glossary of Heating, Ventilation and Air Conditioning Terms

Lesson 36 Selection Of Air Conditioning Systems

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

AIR CONDITIONER Duct Type OPERATING MANUAL

CRAC Precision climate control units for data centres

Transcription:

PCRHK0664 Split Type Air Conditioners FTXR-E Series With DC Inverter Power Control Heat Pump [50 Hz] GOOD DESIGN AWARD IN JAPAN

Ready for new comfort? GOOD DESIGN AWARD IN JAPAN Daikin's Ururu Sarara series of air conditioners is the first in the world* to offer humidifying and drying functions for humidity control along with fresh air supply ventilation. It provides advanced climate control for an optimally comfortable indoor environment. Sarara drying operation This function maintains a comfortable and refreshing indoor environment by removing moisture from the air without lowering the temperature. It is ideal for rainy weather and summer nights, maintaining a comfortable environment without making the air chilly. Ururu humidifying operation This new type of humidifying system uses moisture from outdoor air to raise the indoor humidity level, so does not need a separate water supply. It maintains a comfortable humidity level even during dry weather. Fresh air supply ventilation With the room windows closed, this function gently infuses the room with fresh air from outdoors. Energy savings The latest technology enables Ururu Sarara to achieve a high COP of 5.00 during cooling and 5.14 during heating operation for the 2.8 kw class. Clean air The Flash streamer air purifying unit effectively eliminates allergens, such as pollen and dust mites, and even adjuvants from the air. 1 * As of October 1999 when released in Japan.

Heat Pump Type FTXR28EV1B/RXR28EV1B 2. 8 (1. 55-3. 6) kw 9, 600 (5, 300-12, 300) Btu/h 3. 6 (1. 3-5. 0) kw 12, 300 (4, 400-18, 800) Btu/h FTXR42EV1B/RXR42EV1B 4. 2 (1. 55-4. 6) kw 14, 300 (5, 300-15, 700) Btu/h 5. 1 (1. 3-5. 6) kw 17, 400 (4, 400-19, 100) Btu/h FTXR50EV1B/RXR50EV1B 5. 0 (1. 55-5. 5) kw 17, 100 (5, 300-18, 800) Btu/h 6. 0 (1. 3-6. 2) kw 20, 500 (4, 400-21, 200) Btu/h RXR28/42/50EV1B GOOD DESIGN AWARD IN JAPAN The "Good Design Award" is Japan's only synthetic design evaluation/recommendation system and is sponsored by the Japan Industrial Design Promotion Organization. 2

Ururu humidifying operation Adds moisture to the air to maintain a comfortable humidity level even during dry weather. Humidifies the indoor air. Extracts moisture from outdoor air. 3

Daikin s exclusive system requires no separate water supply, * 1 so there is no need to add water and no worries about mould. Using a humidifier unit in the outdoor unit, the Ururu humidifying operation function extracts moisture from outdoor air and uses it to raise the moisture level of the indoor air throughout the room. The system is very hygienic because there is no water tank requiring periodic refilling. Humidification volume (volume of moisture added to air per hour* 2 ) FTXR28E 400 ML/h FTXR42E 425 ML/h FTXR50E 450 ML/h Above figures are for c ontinuous humidific ation operation. B ec ause the Ururu S arara uses a different humidific ation method from c onventional humidifiers, the ac tual humidific ation volume varies depending on outdoor c onditions and installation details. Humidific ation volume is reduc ed by approximately 15% when the outdoor temperature drops by 5 C. Humidific ation volume is reduc ed by approximately 20% when the outdoor relative humidity drops by 20%. A humidifier hose length (piping length) of 7.5 metres is used as the standard. E xtending the hose length by 2 metres will Outdoor unit Extracts moisture from outdoor air. Humidifier unit Humidifies the indoor air. No need to replenish water supply. Moisture is added to the warm air flowing into the room, so even a large living room is humidified evenly. Ururu humidifying operation is the ideal form of winter heating because it combines the functions of an air conditioner (heater) and a humidifier in a single system. The powerful humidifying function spreads warm, moisturised air evenly to every corner of the room. Humidity is maintained at the ideal level for skin that is sensitive to dryness. Tendency to humidify unevenly Humidified heating Even humidification Humidifier only Humidified air tends to collect near the ceiling. Humidified heating Humidified air spreads evenly throughout the room. Perceived warmth is heightened, helping to avoid excess heating. Humidified heating is gentle to the human body. The dryer the air, the less our bodies perceive the warmth around us. Ururu humidifying operation humidifies the indoor air just the right amount so that you feel comfortably warm even at a relatively low temperature setting. Feels chilly Room temperature: 28 C Relative humidity: 20% Humidified heating Feels pleasantly warm Room temperature: 22 C Relative humidity: 50% The thermograph shows the temperature distribution on the skin surface 30 minutes after entering the room. S tudies by Daikin show that at 30% relative humidity, perc eived warmth c hanges by approximately 1 C. 30.0 35.0 C (Results of Daikin experiment) If the air is dry, you don t feel warm even if the temperature is raised. If the air is moist, you feel warm even at a lower temperature. The humidity may not reach the exact level due to the effects of indoor or outdoor conditions. Dry air is ideal for the spread of viruses. Ururu humidifying operation lets you keep the air optimally moist.* 3 It is understood that the mortality rate of viruses rises when the relative humidity is 40% or higher. Ururu humidifying operation maintains the moisture in the air so that viruses have difficulty propagating.* 2 *1. Household air conditioners using a humidification system not requiring a separate water supply (current as of April, 2006). *2. Humidification capacity measurement conditions: Outdoor temperature 7 CDB, 6 C WB (heating capacity measurement conditions). Humidification capacity drops when outdoor temperature and humidity are low. Actual humidity may not reach the exact level if the ventilation air volume is high or the temperature setting is high. Maximum power consumption of humidifier heater is approximately 560 W. Level is controlled between 0 W and maximum power consumption. Operation pattern during humidifying operation may differ due to factors such as customer settings, room size, ventilation frequency, and temperature and humidity conditions. *3. Ururu Sarara is not intended for use as a medical device. 4

Sarara drying operation Sarara drying operation removes moisture from the air without lowering the temperature, keeping the indoor environment fresh and comfortable. Removes moisture from the indoor air. Air is a comfortable temperature, not too chilly. 5

Sarara drying operation dehumidifies without making the room chilly. * 1 When the weather is rainy or on summer nights, using the air conditioner s cooling and dehumidifying function can end up making the air uncomfortably chilly. Sarara drying operation (dehumidifying with reheating)* 1 uses waste heat from the outdoor unit to warm the cold dehumidified air, and then sends it into the room at precisely the right temperature. *1. A reheating system that does not lower the room temperature, as defined by the Japan Refrigeration and Air Conditioning Industry Association. Indoor unit Warms air to regulate temperature. Chills air to remove moisture. Comfortable air at just the right temperature. Refreshingly dry without lowering the temperature. The programme dry operating mode of a conventional air conditioner removes moisture by operating in a reduced capacity cooling mode. This causes the indoor temperature to drop. Sarara drying operation removes moisture from the air without lowering the indoor temperature. It is ideal for humid times such as during rainy weather when the temperature is not particularly high. Feels chilly Conventional programme dry Sarara drying operation Refreshing and comfortable Sarara drying operation Room temperature: 19 C Relative humidity: 50% Air feels chilly because the air conditioner cools the air while dehumidifying. Room temperature: 22 C Relative humidity: 50% Air does not feel chilly because the air conditioner dehumidifies without cooling the air. At the same room temperature, with lower relative humidity you feel cooler and fresher. Even at the same room temperature, if the relative humidity is high you feel hot and clammy. Sarara drying operation lowers the humidity only so you feel cool and refreshed. Hot and clammy Sarara drying operation Cool and refreshing The thermograph shows the temperature distribution on the skin surface 30 minutes after entering the room. 30.0 35.0 40.0 C (Results of Daikin experiment) Room temperature: 25 C Relative humidity: 80% The high humidity makes you feel hot and clammy. Room temperature: 25 C Relative humidity: 50% You feel comfortable, though the temperature is the same. Dry cooling operation dehumidifies and cools the air at the same time. On hot summer days when dehumidifying alone would leave the air uncomfortably warm, the dry cooling operation mode lowers moisture and cools the air at the same time for maximum comfort. Time when Sarara drying operation is appropriate Dry cooling operation makes it too cold. Time when Dry cooling operation is appropriate Dehumidifying alone makes it too hot. The humidity may not reac h the exac t level due to the effec ts of indoor or outdoor c onditions. S arara drying operation c onsumes more power than dry c ooling operation. Rainy weather and summer nights (outdoor temp. approx. 10 C to 27 C) Midsummer (outdoor temp. 27 C and above) 6

Fresh air supply ventilation Powerful ventilation from fresh air, with the windows closed. Large air volume of 32 m 3 /h (32,000 L /h) 7

Large ventilation air volume Ururu Sarara's fresh air supply ventilation function is powerful enough to completely replace the air in a room* 1 measuring approximately 26 m 2 in two hours. It can quickly ventilate spaces like a living room, where the whole family gathers, by pumping in plenty of fresh air. You can use Ururu Sarara as a replacement for a conventional ventilation fan. Fresh Air Supply Ventilation Volume* 2 Setting Normal High FTXR28/42/50E 24m 3 /h 32m 3 /h The actual air volume may be reduced under certain installation conditions and room usage conditions. The amount of air a person breathes in an hour is about 600 L* 3. When the whole family is gathered in the living room, you want to make sure there is plenty of fresh air. Eliminates pollen, dust, and odours. Only pure air is supplied. Ururu Sarara uses a powerful fresh air supply ventilation method. This two-stage air purifying process, involving both the outdoor and indoor units, rapidly introduces fresh air from outdoors into the room. How Fresh air supply ventilation works Outdoor unit Heat catalyst Indoor unit Air supply filter Unpleasant odours and pollen A heat catalyst effectively eliminates odours. Fresh air Plenty of clean, fresh air is introduced into the room. Pollen Odours Dust Fresh air supply ventilation lets you freshen the air in the room without opening the windows. During fresh air supply ventilation operation, outdoor air is taken in by the outdoor unit, warmed by the indoor unit during heating operation and cooled during cooling operation, and supplied to the room. Unlike conventional ventilation fans, this system prevents hot or cold air from entering through gaps under doors and the like. During heating operation Using a ventilation fan or opening the windows Fresh air supply ventilation Drafts Cold air from outdoors enters the room, lowering the overall temperature. Cold air from outdoors is warmed by the indoor unit's heat exchanger before being supplied to the room. *1. Ceiling height of 2.4 m *2. Measuring conditions as specified in Japan Refrigeration and Air Conditioning Industry Association standards (JIS B8330 compliant). Measuring conditions: Standard ducts, hose length of 5 metres with 5 bends (including indoor connection cuffs) and open to the outdoor air. Airflow volume drops under certain installation conditions and usage conditions. *3. Assuming that an adult at rest takes into the lungs 0.5 L of air per breath (10 ml/kg and body weight of 50 kg) and takes 20 breaths per minute (0.5 L x 20 breaths x 60 minutes = 600 L). These figures are calculated based on normal food intake and maximum lung activity and number of breaths. Actual results may differ due to factors such as type of activity and temperature. 8

Clean air A first* 1 in an air conditioner! The Flash streamer air purifying function removes both allergens and adjuvants. The comprehensive air purifying function, Flash streamer is employed in an air conditioner for the first time* 1. The powerful Flash streamer rapidly removes not only pollen and dust mites, but adjuvants like diesel soot and car exhaust that accompany allergens as well. Removal of Allergens Pollen, dust mites, mould, etc. Removal of Adjuvants Diesel exhaust particles, exhaust gas, etc. Deodorising Odours of household trash, pets, cigarettes, etc. Removal of Bacteria Bacteria, viruses, mould spores, etc. New air purifying system with Flash streamer The Flash streamer s electrical discharge delivers an oxidative decomposition speed over 1,000 times that of conventional plasma (glow) discharge systems, while using the same electrical power. The rapid outflow of electrons strikes allergens and odour particles, breaking them down and eliminating them. Air purifying by Flash streamer Air filter Flash streamer unit Titanium Apatite Photocatalytic air-purifying filter Deodorising filter Speedy deodorising Remainder (%) 100 80 60 40 20 Lifestyle odour elimination rate Natural reduction Over 90% eliminated in approx. 10 min. 0 5 10 15 Time (min.) Ammonia: Pet and toilet odours Trimethylamine: Fish odours Methylmercaptan: Odour of decay Hydrogen sulfide: Rotten egg odour * Odour components remaining in 1 m 3 box as measured using FTXR42E (tests performed by Daikin). Mould shock operation to keep your room clean and sanitary This function rapidly lowers the humidity within the room and keeps it low for two hours to eliminate residual moisture. It is very effective on humid days and during rainy weather. Mould shock operation eliminates residual dampness at a stroke. R apidly lowers the humidity within the room to c reate an environment that inhibits mould growth. Mould shoc k operation is not 100% effec tive in preventing new mould growth, nor will it kill off mould that has already bec ome established. Operating outdoor temperature range: 12 C to 40 C It is rec ommended that you leave the room empty when this powerful anti-mould func tion is operating. Moist air collects inside due to super-insulation of houses. Ururu Sarara Mould shock operation eliminates residual dampness at a stroke. Approximately once every two weeks after cooling and dehumidifying operation has finished for the day, the air conditioner automatically* 2 expels internal moisture outdoors in order to dry itself out. This prevents it from emitting a mouldy smell when it starts to operate. *1 As of April 2006. *2 Must be set using the remote control. Frequency may be three weeks or more depending on conditions. 9 Mould proof operation runs for internal cleaning of indoor units

Energy savings All models incorporate the most advanced energy saving technology. High COP rating Features such as the new swing compressor and reluctance DC motor provide excellent energy efficiency, achieving high COPs. C O P (W/W) 5.00 4.00 5.00 5.14 4.00 4.32 3.42 3.97 3.00 2.00 1.00 FTXR28E FTXR42E FTXR50E Incorporates new energy saving technology Outdoor unit with new twist grille The grille is angled to match the outflow stream from the outdoor unit s fan. This reduces wind resistance and improves energy efficiency. The right and left portions of the grille are eac h parallel to the airflow path. This reduc es wind resistanc e and inc reases effic ienc y. Right portion of grille Left portion of grille The grille fins are oriented upward to matc h the upward airflow. The grille fins are oriented downward to matc h the downward airflow. Conventional grille R ight portion The grille fins are oriented horizontally, resulting in inc reased wind resistanc e and reduc ed effic ienc y. Left portion Indoor unit with slide-opening panel and saw edged fan The compact indoor unit is only 209 mm deep (when not operating). Features such as the slide-opening panel and saw edged fan make possible its high COP rating. During operation Silde-opening system The front panel has a slide-opening mechanism that allows it to take in a sufficient volume of air. Saw edged fan The fan blades have a sawtooth edge configuration that reduces wind resistance. This results in improved efficiency and reduced noise. 10

Valuable new functions Moisturising operation The moisturising operation mode is a special version of Ururu humidifying operation with a higher humidity setting during heating operation. It surrounds your skin in humidified air that gently moisturises dry skin. During cooling operation, the moisturising operation mode boosts the humidity setting to keep your skin feeling good through the summer. Humidity control keeps provides optimum conditions year round for sensitive people s skin. Normal Ururu humidifying operation Moisturising operation Extra gentle Moisturising operation This feature controls the indoor temperature while you are asleep, helping to produce the pattern of body temperatures most conducive to restful sleep. The comfortable sleep programme controls the temperature in a V-shaped pattern. (Assuming 6 hours of sleep) Temperature setting vv 2 C Comfort sleep operation ON User sets wakeup time. (2) You awake feeling refreshed. Raises the room temperature. (1) Accelerates onset of deep sleep. Lowers the room temperature so you fall into a deep sleep quickly. 3 Hours 2 Hours 1 Hour Awakening Sleep time 0 1 2 3 4 5 6 (1)Accelerates onset of deep sleep. The room temperature drops slowly as you begin to sleep, lowering your body temperature while you are asleep. (2) You awake feeling refreshed. The room temperature slowly rises as your wakeup time approaches, causing your body temperature to rise immediately before you awake. breeze operation Comfortable mode In winter the warm air is directed straight downward to your feet. In summer the cool air descends from the ceiling gradually throughout the entire room. The comfortable mode prevents air from blowing directly on the skin, which provides a gentle and comfortable environment. The outflow sways gently up and down in a 1/f rhythm. This frequency provides a comfortable cool breeze that feels natural and makes the room feel cool even though the temperature is set higher. Air purifying operation The air purifying function can be used alone or in combination with heating or cooling operation. It effectively cleans the air, eliminating microorganisms as well as unpleasant odours. Home leave ventilation Down from above during cooling operation Air supply filter incorporates vitamins and hyaluronic acid,* 1 and provides an environment with comfortable air that is gentle to your skin. 11 Air supply filter Air supply filter incorporating vitamins and hyaluronic acid* 1 Straight to the floor during heating operation Note: Shown with front panel removed. *1. It is recommended that the air supply filter be replaced about once a year. This function uses a timer to control the ventilation function. It allows you to freshen the indoor air while you are out, for example during the summer when the air can become hot and dank. Mould proof stick Often a haven for mould in conventional air conditioners, the drain pan of the Ururu Sarara is equipped with a mould proof stick that effectively prevents buildup of mould, bacteria, and viruses. Child proof lock This function allows you to lock the operation of the air conditioner by pressing a button on the remote control. The setting is controlled using the SET UP button.

Easy Control Temperature/humidity level display Countdown off timer Sarara Dry Temperature setting Ventilation/air purifying Air flow volume setting Comfortable mode/ breeze operation Set up Child proof lock Mould proof automatic Monitor brightness setting Beep volume setting LCD contrast setting 24Hr ON/OFF timer Clock setting Closed Opened Temperature and humidity level information display Using the INFO button on the remote control, you can display the current indoor temperature and humidity level. The display serves as a reference during humidifying or dehumidifying operation and allows detailed checking of the humidity level to help you prevent mould or dust mite proliferation. Multi-coloured indicator The colour of the indicator lamp on the indoor unit changes to match the current operating mode. It always shows the current mode even when operation is set to automatic. Countdown off timer ON/OFF Ururu humidifying Automatic operation (cooling/heating) Inverter powerful operation Humidity setting Vertical swing Horizontal swing Moisturising operation Home leave ventilation Mould shock operation Mould proof operation Comfort sleep operation Filter cleaning indicator (LED) reset Set the time until shutdown to up to a duration of 9.5 hours with the touch of a single button. Function list Worry Free Timers Cleanliness Lifestyle Convenience Comfort Control Comfortable Airflow Humidity control Ururu humidifying operation Moisturising operation Sarara drying operation Dry cooling operation breeze operation Comfortable mode Power-airflow dual flaps Wide-angle louvres Vertical auto-swing (up and down) Horizontal auto-swing (left and right) 3-D airflow Comfort sleep operation Auto fan speed Indoor unit quiet operation Automatic operation Multi-coloured indicator Monitor brightness setting Temperature & humidity level information display Child proof lock Inverter powerful operation Indoor unit on/off switch Air purifying operation Titanium apatite photocatalytic air-purifying filter Air supply filter Flash streamer air purifying Mould proof air filter Wipe-clean flat panel Filter cleaning indicator Mould shock operation Mould proof operation Mould proof stick Fresh air supply ventilation Home leave ventilation Countdown off timer 24-hour on/off timer Night set mode Auto-restart after power failure Self-diagnosis with digital display Anticorrosion treatment of outdoor heat exchanger fins 12

Specifications Heat pump Model name Capacity Power supply Running current (220 V) Power consumption COP Indoor unit Front panel colour Airflow rate (H) Fan speed Sound levels (H/L/SL) Dimensions (H x W x D) Machine weight Outdoor unit Casing colour Compressor Refrigerant charge (R-410A) Sound levels (H) Dimensions (H x W x D) Machine weight Operation range Piping connections Max. piping length Max. height difference Indoor unit Outdoor unit Rated kw (Min.-Max.) Btu/h Rated kw (Min.-Max.) Btu/h Rated Rated (Min.-Max.) Rated Type Motor output Liquid Gas Drain A W W/W m 3 /min (cfm) db (A) mm kg W kg db (A) mm kg CDB CWB mm m m FTXR28EV1B RXR28EV1B 2.8 (1.55-3.6) 9,600 (5,300-12,300) 3.6 (1.3-5.0) 12,300 (4,400-16,400) 3.2 3.9 560 (250-800) 700 (220-1,410) 5.00 5.14 FTXR28EV1B 11.1 (392) 12.4 (438) 39/26/23 41/28/25 RXR28EV1B 46 46 FTXR42EV1B RXR42EV1B 4.2 (1.55-4.6) 14,300 (5,300-15,700) 5.1 (1.3-5.6) 17,400 (4,400-19,100) 1 phase, 220-240 V, 50 Hz 5.3 5.9 1,050 (260-1,320) 1,180 (220-1,600) 4.00 4.32 FTXR42EV1B White 12.4 (438) 12.9 (456) 5 steps, quiet and automatic 42/27/24 42/29/26 305 x 890 x 209 14 RXR42EV1B Ivory white Hermetically sealed swing type 1,100 1.4 48 48 693 x 795 x 285 48-10 to 43-20 to 24 ø6.4 ø9.5 ø18.0 10 8 FTXR50EV1B RXR50EV1B 5.0 (1.55-5.5) 17,100 (5,300-18,800) 6.0 (1.3-6.2) 20,500 (4,400-21,200) 7.2 7.4 1,460 (260-1,800) 1,510 (230-1,770) 3.42 3.97 FTXR50EV1B 13.3 (470) 14.0 (494) 44/29/26 44/31/28 RXR50EV1B 48 50 Measurement conditions 1. capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m. 2. capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m. 3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions. Specifications are subject to change. GOOD DESIGN AWARD IN JAPAN RXR28/42/50EV1B 13

Options Indoor units No. 1 2 3 4 5 Item 5-room centralised controller* 1 Wiring adaptor for time clock/remote controller* 2 (Normal open pulse contact/normal open contact) Air purifying filter set* 3 Air supply filter with frame Remote controller loss prevention chain FTXR28EV1B FTXR42EV1B KRC72A KRP413AA1S KAF974B42S KAF963A43 KKF936A4 FTXR50EV1B Notes: *1. A wiring adaptor (KRP413AA1S) is also required for each indoor unit. *2. Wiring adaptor supplied by DAIKIN. Time clock and other devices should be obtained locally. *3. A set of a frameless Titanium Apatite Photocatalytic air-purifying filter and a frameless deodorising filter for the Flash streamer unit. Both filters are standard accessories. 5-room centralised controller KRC72A Air purifying filter set KAF974B42S Air supply filter with frame KAF963A43 Outdoor units No. 1 2 3 4 5 6 Air direction adjustment grille Drain plug* 1 Humidity hose extension joint* 2 Humidity hose L cuff* 2 Humidity hose (10 m) Humidity hose extension set* 3 Item RXR28EV1B RXR42EV1B KPW937AA4 KKP937A4 KPMJ942A4 KPMH950A4L KPMH942A42 KPMH942A402 RXR50EV1B Notes: *1. One set includes 5 pieces for 5 units. *2. One set includes 10 pieces. *3. One set includes a 2 m extension hose, 1 joint, and 2 tieraps Drain plug KKP937A4 Humidity hose L cuff KPMH950A4L Humidity hose extension set System configurations No. 1 2 3 4 Central remote controller* Unified on/off controller* Schedule timer* Interface adaptor for D -NET use Item FTXR28EV1B FTXR42EV1B DCS302CA51 DCS301BA51 DST301BA51 KRP928BA2S FTXR50EV1B Note: * A wiring adaptor (KRP928BA2S) is also required for each indoor unit. Central remote controller DCS302CA51 Unified on/off controller DCS301BA51 Schedule timer DST301BA51 14

Warning Daikin Industries, Ltd. s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment. About ISO 9001 JMI-0107 JQA-1452 ISO 9001 is a plant certification system defined by the International Organization for Standardization (ISO) relating to quality assurance. ISO 9001 certification covers quality assurance aspects related to the design, development, manufacture, installation, and supplementary service of products manufactured at EC99J2044 JQA-E-90108 About ISO 14001 ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ c All rights reserved Printed in Japan 11/06/003 DN Specifications, designs and other content appearing in this brochure are current as of November 2006 but subject to change without notice. Printed on 100% recycled paper with soy ink.