Charlotte County Community Development Residential Swimming Pool / Spa Quick Permit



Similar documents
Charter Township of Shelby Harry Reese Building Director

City of Miramar Building Division

Shed Application Package

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Zoning Department DECK PERMITS. Checklist

City of Miramar ELECTRICAL GENERATOR APPLICATION PACKAGE. Who Can Apply

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

TOWN OF SPENCER Office of Development & Inspectional Services

Who Can Apply (A or B)

PERMIT APPLICATION. PLEASE PRINT LEGIBLY INCLUDE STREET NUMBER/NAME, CITY & STATE 1 Job Name:

ORDINANCE NO

How To Protect A Swimming Pool

Fence Application Package

BUILDING PERMIT SPECIFICATIONS

Depending on the nature of your project, below is a checklist of what this office requires. Make sure you include your .

ATTENTION HOMEOWNERS

Who Can Apply (A or B)

Commercial Construction Permit Application

THE TOWN OF COLONIAL BEACH, VIRGINIA DEPARTMENT OF PLANNING AND COMMUNITY DEVELOPMENT

Marion County Board of County Commissioners

City of Douglas Commercial Building Permit Site Application

TOWN OF JUNO BEACH 340 Ocean Drive Juno Beach, FL Phone: (561) Fax: (561)

RESIDENTIAL WOOD DECKS

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

CHAPTER 67.2 RESIDENTIAL BUILDING CODE

SWIMMING POOL / SPA PLAN REVIEW CHECKLIST

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

CODE IN EFFECT: 2010 FLORIDA BUILDING CODE PERMIT APPLICATIONS MUST BE FILLED OUT COMPLETELY

17 East Main Street Cuba,NewYork Code Enforcement

Bureau Veritas Contact Information

Town of Clinton. TRENCH PERMIT 242 Church St.Clinton Ma Telephone# Office (978) FAX (978) This Section for Official use only

BUILDING A FENCE? THE CITY OF CAMBRIDGE REQUIRES THAT ALL FENCES WITHIN THE CITY CONFORM TO THE REGULATIONS OF FENCE BY-LAW

RESIDENTIAL UTILITY PERMITS APPLICATION PACKET

Heating Load HERS: Calcs Duct Seal and Test (h), (m)1-3 & 11

VILLAGE OF SHOREHAM. Instructions for obtaining a building permit for a new home for all one-family dwellings (with required forms)

Fill out all sections or mark with N/A (not applicable)

Uncovered Decks & Porches

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE APPLICATION REVIEW

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

MOBILE HOME LAW. Revised November 2001

CORAL SPRINGS BUILDING DIVISION HOMEOWNER PERMIT INFORMATION

OWNER-BUILDER ACKNOWLEDGEMENT & INFORMATION VERIFICATION

Ferry County Out Building Application

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

Sec Adoption of Texas Department of Health Standards for Public Swimming Pool and Spa.

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

SUMMIT TOWNSHIP SIGN PERMIT PROCESS

CONSTRUCTION LAW. Mechanical Roofing Contractor. Electrical Class A Air Conditioning. Contractor Class B Air Conditioning

Building Permits: When are they required?

Furnace/Air Conditioner Permit by FAX or Mail

D Sample Notices to Property Owners, Sample Affidavits, and Other Material

CHECKLIST OF DOCUMENTS NEEDED DO NOT FAX, BRING ALL DOCUMENTS WITH THIS APPLICATION THREE CONTRACTOR AFFIDAVITS OF WORK EXPERIENCE.

Residential Plan Routing Information

Residential Building Permit Process

HEDDERMAN ENGINEERING, INC. Office , Fax

APPLICATION FOR A FILL, EXCAVATION AND SITE GRADING PERMIT

City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA ,

MP 3.4 SWIMMING POOL BARRIERS. Table of Contents

Village of Airmont APPLICATION FOR BUILDING PERMIT INSTRUCTIONS

PERMIT APPLICATION REQUIREMENTS FOR RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEMS

ORDINANCE NOW, THEREFORE, BE IT ORDAINED BY THE CITY OF BRENTWOOD, TENNESSEE, AS FOLLOWS:

CALIFORNIA CODES HEALTH AND SAFETY CODE SECTION This act shall be known and may be cited as the Swimming Pool Safety Act.

2880 International Circle Colorado Springs, CO Telephone Executive Summary Pikes Peak Regional Building Code Revisions

Site Development Information Worksheet for single family residential development

Application Package for License for Sidewalk Dining Adjacent to Eating Establishment

Definition of Tower from the Bradley County Zoning Resolution

Fall Protection, Title 29 Code of Federal Regulations (CFR) Part 45, Subpart M, Fall Protection, , , , and1926.

BE IT ORDAINED BY THE BOARD OF COUNTY COMMISSIONERS OF. Amendments to Chapter 9, In General. Chapter 9 of the Orange County

APPLICATION. Internal Use Only 1311 Chestnut Street TDLR# Bastrop, Texas Intake Date

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Quarryville Borough. 300 Saint Catherine Street Quarryville, PA Application for a Building/Zoning Permit

INCORPORATED VILLAGE OF OYSTER BAY COVE TOWN OF OYSTER BAY, NASSAU COUNTY, N.Y. OFFICE BUILDING INSPECTOR FEE SCHEDULE

Sample Drawing Package for One and Two Family Dwelling Applications

SWIMMING POOLS, SPAS AND HOT TUBS Section AG101 General.

WHO CAN PULL A BUILDING PERMIT?

Manufactured Home Application Packet

RESIDENTIAL ELECTRICAL ONLY PERMIT PACKET

Division Yard, Lot, and Space Regulations.

Fall protection systems and practices Duty to have fall protection Protection at or above 6' level.

PERMIT APPLICATION FORM SELECT ALL THAT APPLY: BUILDING DRIVEWAY ELECTRICAL PLUMBING HEATING DEMOLITION SIGN MOBILE HOME

Protecting Your Pools Crack Treatments

Development Services Department City of San Antonio. Permits & Licenses. Development Services Manager. Deputy Historic Preservation Officer

BUILDING PERMITS. Santa Rosa County Building Inspection

REQUIREMENTS FOR OBTAINING A THORNBURY TOWNSHIP, DELAWARE COUNTY PERMIT

City of La Vernia 102 E. Chihuahua Street, La Vernia, Texas Phone: (830) Fax: (830)


Section 801 Driveway Access Onto Public Right-of-Ways

Building Your Interlocking Concrete Pavement to Last a Lifetime

General Contractors/Developers General Liability Application

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

QUEEN ANNE'S COUNTY BUILDING CODE TECHNICAL ASSISTANCE BULLETIN

Maximum Floor Area and Maximum Development Area

TOWN OF TRURO BUILDING PERMIT APPLICATION

Chapter 11 - Streets ARTICLE 1 COASTING AND SKATEBOARDING ARTICLE 11 SNOW REMOVAL ARTICLE 111 HORSES ARTICLE IV DISPLAYING GOODS AND WARES

Transcription:

Permit # 2000- Charlotte County Community Development Residential Swimming Pool / Spa Quick Permit 18500 Murdock Circle, Room 107 Port Charlotte, Florida 33948-1094 Permitting 941-743-1201 Zoning 941-743-1964 Fax 941-743-1213 Property Tax I.D.Number Address of work to be done Description of work Lot Block Sec.: Twn.: Rge.: Subdiv.: Zoning Class: Corner Lot? Y - N Inside Lot? Y - N Set Backs: Front Rear Left Right Flood Zone: Map Page: Waterfront? Y - N V-Flood Zone Pool/Spa Prohibited as Quick Permit Concrete Other Surface Area of pool sq.ft. Surface Area of deck Solar Owner: Contractor: Address: Address City/State/Zip City/State/Zip Phone# Fax# Phone# Fax# The undersigned applicant for this building permit does hereby certify that he/she has or will prior to the performance of any work in connection with the authorization granted under this permit comply with the provisions of the Florida Workman s Compensation Act of Employer s Liability Insurance and Social Security Act, the Florida Child Labor Laws, and other safety and labor laws of the state. Violation will invoke severe penalties. All work, materials, equipment, and design shall meet the minimum standards of the ANSI- American National Standards Institute: ANSI/NSPI - 5 1995 American National Standard for Residential Inground Swimming Pools and Charlotte County Code # Section 3-2-69 SWIMMING POOLS, including amendments; National Electrical Code 1999 Edition and the Standard Building Code 1997 Edition. I certify that I have read the foregoing and the information I established on this affidavit is true to the best of my knowledge: Signature of Contractor or Owner/Builder: Date Contractor License # Construction Cost (including labor) $ Include the following required documents: 1. Photo copy of property survey showing, all maintenance, utility, and right of way easements (one copy). 2. Swimming pool site plan showing configuration of pool, equipment location, decks, foundation foot print, specification of construction, depth of excavation, distance from structure(s) - form provided (two copies). 3. Subcontractor Worksheet (one copy). 4. Notice of Commencement (one copy). 5. Application form (two copies). Note: All subcontractors must have a Charlotte County Certificate of Competency. Permit is void if construction is not started within six months or does not receive an approved inspection within six months from date of issue. An approved inspection will extend this permit for an additional six months. Starting work prior to issuance of a permit will result in a penalty up to four times the permit fee. Warning to owner: your failure to record a notice of commencement may result in your paying twice for improvements to your property. Form: 2000-010 revised March 8, 2000

Exemption of Required Angle of Repose Based On Previously Designed Foundation Swimming pool excavations which violate the required angle of repose are prohibited as Quick Permit and shall require site specific engineering or provide information that the residential structure foundation had been previously designed for said excavation. Contractor of Record for Structure Address Phone # Fax # Property Address Depth of proposed excavation distance from structure Permit # Note: If permit file for structure has been archived, swimming pool contractor shall fill out research request form and provide copy of archived foundation plans for review. SBC 1803.1.1 When excavating for buildings or excavations accessory thereto, such excavations shall be made safe to prevent any danger to life and property. SBC 1803.1.3 Excavations for any purpose shall not extend within 1 ft. (305 mm) of the angle of repose or natural slope of the soil under any footing or foundation, unless such footing or foundation is first properly underpinned or protected against settlement. Signature of Applicant: Date: Official use only do not write below this line Checked by Date Depth of excavation shown on original structure plans on file matches proposed: YES NO Distance from structure shown on original structure plans on file matches proposed: YES NO

Exemption of Required Angle of Repose Based On Previously Designed Foundation Swimming pool excavations which violate (be required angle of repose arc prohibited as Quick Permit and shall require site specific engineering or provide information that the residential structure foundation had been previously designed for said excavation. Contractor of Record for Structure: Address: Phone: Fax: Property Address: Depth or proposed excavation: distance from structure Permit #: Note: If permit file (or structure has been archived, swimming pool contractor shall fill out research request form and provide copy or archived foundation plans for review. SBC 1803.1.1 When excavating for buildings or excavations accessory thereto, such excavations shall be made safe to prevent any danger to life and property SBC 1803.1.3 Excavations rot- any purpose shall not extend within 1 ft (305 mm) of the angle of repose or natural slope of the soil under any footing or foundation unless such footing or foundation is first properly underpinned or protected against settlement. Signature of applicant: Date: Official use only do not write below this line ********************************************************************************** Checked by: Date: Depth of excavation shown on original structure plans on file matches proposed: YES NO Distance from structure shown on original structure plans on file matches proposed: YES NO Form 2000-007 reviewed 1/31/00 TS

County of Charlotte Community Development Department Charlotte County Administration Center 18500 Murdock Circle Port Charlotte, Florida 33948-1094 Phone: 941-743-1201 The minimum compressive strength of concrete used In the pool and spa shell construction shall be 3,500 p.s. i. The minimum shell thickness shall be four (4) inches / gunite, five (5) inches / shotcrete, and six (6) inches / handstacked. Foundations for deck supporting pool cages shall be 12 x 12 w/ 2-#5 for monolithic slabs and 8 x 16 w/ 2#5 for stemwall foundations. Article XV (15) SAFETY FEATURES 15.1 Handhold,: An inground residential pool shall be provided with a handhold around its perimeter in areas where depths exceed 3 feet six inches(1.0668 in). Handholds shall be provided no farther apart than 4 feet (1.2192 m) to include but not be limited to, any one (1) or a combination of items listed in Articles 15.1.1 through 15.1.3 15.1.1 Coping, ledge, or deck along the immediate top edge of the pool which provides a slip-resisting surface of at least 4 inches (102 mm) minimum horizontal width and located at or not more than 12 inches (305 mm) above the waterline: or, 15.1.2 Ladder, stairs, or seat ledges; or, 15.1.3 A secured rope or railing placed at or no more than 12 inches (305 mm) above the waterline. Contractor to verify location or foundation prior to excavation.

Depth of Footing DEPTH OF DIG-OUT AT SIDE WALL BASED ON 34.5 DEGREE ANGLE OF REPOSE Distance from foundation 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 12 28 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 16 32 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 20 36 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 24 40 44 48 52 56 60 64 68 72 76 80 84 88 92 96 100 This chart is only to serve as a guideline based on National averages and cannot replace site specific soil analysis prior to excavation.