Service Manual for Float Flow Meter Monitor Type: SWK



Similar documents
Operating Instructions for Plastic Flow Meter. Model: KSK

KOBOLD VKP FLOWMETER/SWITCH. User Instructions

Instruction Manual Differential Pressure Transmitter

Electronic Pressure Switch EDS 3000

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

These Installation Instructions are valid for antennas in the following version:

System 8. ü ( System 8

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Inductive sensor NI10-M18-Y1X-H1141

Battery Powered Thermal Mass Flow Meters for Gases

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

IMPORTANT DOCUMENTATION DO NOT DISCARD!

2/2 and 3/2 Way Size 6 Seat Valves

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Portable digital microprocessor thermometers with interchangeable probes

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

3/2- and 2/2-way cartridge valve type BVE

Mounting Instructions. Torque Transducer. A en

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Battery Powered Thermal Mass Flow Meters for Gases

Operation Manual For NDJ-8S Digital Rotary Viscometer

Digital display DA 48

Cable Plug acc. to DIN EN , Form A

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Plastic tube flowmeters Series PT/PS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Compact pressure switch Flameproof enclosure Ex d Model PCA

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Flow switches Series AD/VH

Electro-hydraulic pressure switches type DG

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Turbine Flow Sensor Series VTR

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

3/2-way Solenoid Valve, direct-acting, NC or NO

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

HERZ-Thermal Actuators

Solenoid valves Type EVU

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Series 6000 Torque measured metal bellow coupling

Model 43AP Pneumatic Controller, Style B

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Infrarot-Bewegungsmelder IP44

Laing industrial pumps

SureSite Magnetic Liquid Level Indicator

Electronic Pressure Switch EDS 300

Rotary actuators Rotary wing drives Series RAK. Brochure

How To Use A Flowmeter

Battery Powered Digital Mass Flow Meters for Gases

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Pressure regulating valve with modulating kit, type DRV

S4 - Top Hung Window. Outside view. Inside view. Interior frame. Exterior frame. Glazing Panel

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Safety at a high level!

Assisted lift operated 2/2-way solenoid valves Type EV250B

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Solenoid valves 2/2-way direct-operated Type EV210A

Robot Welding Torch System

Relative and absolute pressure switch type 529

Thermometer in stainless steel with capillary and switch contacts

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

REPAIR AND MAINTENANCE MANUAL

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Directional seated valves type VP 1

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Instruction Manual. T3111 T3111L T3111P T3111Ex

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

GREISINGER electronic GmbH

MB-Accumulator Operator's Manual

Proportional pressure regulators VPPE

Reaction Torque Sensor

Electro-pneumatic control valves

Remote Head REMO ONE. Code Manual

Munchkin Heat Exchanger Maintenance

Machine needle shut-off nozzle type HP

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

Electrical connection

ELECTROMAGNETIC FLOWMETER COMPACT

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

CONFIGURABLE SAFETY RELAYS

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Digital inductive conductivity transmitter

3/2-way Mini Solenoid Valve

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Toroidal Conductivity Sensor

Machine Safety Switches

IFC 070 Technical Datasheet

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Transcription:

Service Manual for Float Flow Meter Monitor Type: SWK

1. Instructions Please read this service manual carefully before unpacking and setting the unit for operation, and follow the instructions precisely as described herein. These devices may only be installed, used and maintained by skilled personnel who are familiar with this service manual and can observe applicable regulations regarding industrial safety and accident-prevention. 2. Contents 1. Instructions...2 2. Contents...2 3. Unit Check-up...3 4. Suggested Application...3 5. Working Principle...4 6. Mechanical Connection...4 7. Electrical Connection...4 8. Electrical Commissioning...5 8.1.Adjustment of limit-value (SWK-1...)...5 8.2.Adjustment of limit-value (SWK-2...)...5 9. Technical Data...6 10. Maintenance...6 11. Dimensions...7 12. Declaration of Compliance...8 Manufactured and Marketed by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: 06192-2990 Fax: 06192-23398 Internet: www.kobold.com e-mail: info.de@kobold.com Page 2 SWK 05/01

3. Unit Check-up These devices are checked before despatch and sent away in perfect condition. Should the damage to a device be visible, we recommend a thorough inspection of the delivery packing. In case of damage, please inform your parcel service/ forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: Standard scope of delivery applies: Unit Service Manual 4. Suggested Application These units of type SWK are used with a view to measure and monitor the liquid flow. Only clean, low-viscous and homogeneous liquids may be measured which do not chemically attack the materials used in the construction of these units. An attempt to measure high-viscous liquids may lead to considerable measurement errors. Large dirt-particles can cause the blockage of float and subsequently turn on error indications. Also, ferrite particles, which deposit on float(with embedded magnets), can generate the same effect (we recommend a magnet-filter). These units are configured in the following manner: Housing made of Brass, St. Steel or PVC Screwed reed contact N.O. with 1m PVC cable (Brass version) Screwed reed contact N.O. with 2m PVC cable (PVC/VA version) Screwed and aligned pointer display (option) SWK 05/01 Page 3

5. Working Principle KOBOLD flow meter/monitor of type SWK according to the well known float principle, however without making use of generally employed extended measuring tube. Inside a cylindrical lead-pipe a float with aperture moves in the direction of the flow against the recoiling force of a spring. Within the float, a pair of magnets is located which trigger a potential-free protective-gas reed contact. The reed contact is mounted on the exterior of flow-housing and drives a pointer display. This arrangement allows the unit to be operated without consideration to mounting position and keeps the installation measures to a minimum. Flow monitors of type SWK generally find application where small volume flow needs to be measured in a fail-safe manner. 6. Mechanical Connection Before installation: Make sure that the permitted max. operating pressure and the operating temperature of the device are not exceeded. Make sure that the electrical supply of the devices corresponds with the operational data of the device. Make sure that no remains of packing material exist within the device. The devices should not be installed within an inductive field. If possible, it should be checked after the mechanical installation whether the connection joints/ piping is properly sealed. Attention! A displacement of switching range occurs if the flow takes place from top to bottom. 7. Electrical Connection Attention! Ensure that the voltage levels of your supply system are in agreement with the voltage levels of this device, mentioned on type-label. The connection of bistable reed contact succeeds through the cable on contact housing. The potential-free contact closes on rising level above the adjusted flow value. Page 4 SWK 05/01

8. Electrical Commissioning The commissioning of these units is prohibited in machines (as long as the guidelines 89/392/EWG remain enforced), which do not comply with these guidelines. The unit is supplied in 'ready for operation' condition. The switching point is adjusted on the lowest scale value. 8.1. Adjustment of limit-value (SWK-1...) Loosen the knurled nut on reed contact. Adjust the marking on the contact for the desired value on the scale. In this position the knurled nut should be tightly screwed. 8.2. Adjustment of limit-value (SWK-2...) Loosen the knurled nut on reed contact. Connect a suitable continuity-checker on cable ends. Case 1: On an installed unit Open the supply line, and let the flow-medium enter slowly, till the pointer display shows the desired flow value, at which the rising flow should operate the switch(the value for the decreasing flow lies below due to the hysteresis). Case 2: On an upgraded unit the adjustment may be performed by lifting the float with a suitable tool. Switch-housing is dislocated from top to bottom, till the reed contact just closes (electrical continuity). In this position, align the contact by rotating the knurled nut. The unit is now adjusted and ready for operation. On correct adjustment, the limit-value contact performs bistable action. That means, even on crossing the adjusted limit-values, the contact remains closed. Hysteresis Hysteresis is an indication of difference between switch-on and switch-off points of a contact. The average hysteresis corresponds to a float-centre movement of about 3 mm. SWK 05/01 Page 5

9. Technical Data Housing/Float: SWK-x1..:Brass (Ni-plated), Ms 58 SWK-x2..: St. Steel, 1.4301 SWK-13..: PVC Connection: G 1/2 female Spring: St. Steel 1.4310 Magnets: Ceramic Impact-rings: SWK-x1..: Brass, Ms 58 SWK-x2..: St. Steel, 1.4301 SWK-13..: PVC Max. temperature: SWK-x1.., SWK-x2: 100 C SWK-13..: 60 C Max. pressure: SWK-x1.., SWK-x2: 250 bar SWK-13..: 6 bar Mounting position: arbitrary Switching point: bistable reed contact N.O. on increasing flow Switching power: max. 230 V AC; max. 3 A, max. 60 VA/Watt Elect. connection: 1 m PVC-cable Switching hysteresis: 3 mm scale deflaction (average value) Repeatability: < 2.5 % (contact) ± 4% measuring value (display) Weight: ~ 350 g Protection cat.: IP 65 10. Maintenance In case the medium to be measured is not contaminated, the device SWK is almost maintenance-free. With lime or such depositions within inner sections the device should be cleaned regularly. Screw loose and take out the device from the piping employing a suitable fork wrench. After removing the upper connection joint, the inner parts can be withdrawn for cleaning. The interior can be cleaned with a suitable brush. After cleaning, the device must be reassembled in correct order again. Attention! Before the commencement of maintenance work, ensure that the power lines are not active. Page 6 SWK 05/01

11. Dimensions G 1/2 22,5 SW 27 22,4 15 90 15 G 1/2 G ½ 0 9 l/min. HO 2 Typ: SWK G ½ 51 Approx. 70 SWK 05/01 Page 7

12. Declaration of Compliance We, Kobold-Messring GmbH, Hofheim-Ts., Federal Republic of Germany, declare, that the product Float Flow Meter and Monitor Type: SWK... complies with the following standards: DIN EN 61010-1 1994-03 Safety requirements for electrical equipment for measurement, control and laboratory use IEC529, DIN VDE 0470-1 1992-11 Protection through housing (IP-Code) Also, the following EWG guidelines are satisfied: 73/23 EWG Signature: Date: 30.08.00 ppa. Peters ppa. Wenzel Page 8 SWK 05/01