Four Point Inspection



Similar documents
Four- Point Insurance Inspection Report

Direct Inspections - Tel: (941) Michael@DirectInspections.com -

FOUR POINT INSPECTION REPORT

HAZELBAKER CONSTRUCTION SERVICES 8965 QUARRY DRIVE NAPLES, FLORIDA (239)

4-Point Inspection Personal Lines (Edition 9/2012)

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Four-Point Insurance Inspection Report

Home Inspection Report

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Vision Home Inspection

Inspecton Report. Property Address:

PREPARED DATE: SIGNATURE AND SEAL INSPECTION REPORT PREPARED BY: PRINT NAME: REGISTRATION NUMBER: MAILING ADDRESS:

Wind Mitigation Inspection

PROPERTY INSPECTION REPORT

Inspecting to a higher standard.

October 5, 2015 Dear Client,

Property Condition Assessment

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

Building Condition Assessment Report

Inspection Tech. (330) Inspected By: Aaron Westerburg

Vari Inspection Services

Propery Inspection Report

Orlando Home Inspection Services

HomeSpec REPORT SUMMARY

Home Inspection Report

Plumbing Identification and Damage Assessment Guide

I NI NP R Inspected Items

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

SWF Home Inspections

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

INSPECTION REPORT. LOCATION OF PROPERTY 1234 Sample Street Tucson, AZ CLIENT Mr. & Mrs. John Q. Sample c/o Agent DATE OF INSPECTION 1/30/2008

Building Condition Assessment Report

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

APPLICATION FOR NEW CONSTRUCTION

Commercial Building Valuation Report

Section 43. Lead Paint Risk Factor NONE WATER HEATER STORAGE ELECTRIC

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES HOMEOWNER PROGRAM

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

The purpose of this document is to provide standards for persons requesting or subject to County building inspections.

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Home Inspection Report

City of Elk River BASEMENT Office Use Only

CHARLOTTE COUNTY Community Development Department

C I T Y O F P E A R S A L L

Real Estate Inspection Report

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

WOODLAND HOMES BUILDING PROCESS A STEP BY STEP CONSTRUCTION GUIDE TO YOUR NEW HOME

Estimated Cost of Repair

South Carolina Home Inspector Standards of Practice

GENERAL ELECTRICAL REQUIREMENTS

Questions and Answers for Heating and A/C Contractors

COMPREHENSIVE PROPERTY INSPECTIONS

May 5, Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,

EXPRESS PERMITS (No Plan Check Required)

A.C.E. Home Inspection Service St. Peters, MO (636)

This report presents the findings and recommendations of the assessment of energy use and

2. What building projects are exempted? (permit not required)

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

HEDDERMAN ENGINEERING, INC. Office , Fax

Genesis Home Inspections LLC

REPLACEMENT COST ESTIMATOR FORM

10 Secrets of Home Inspections Every Home Buyer Should Know

Pre-Drywall Inspection Report

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL South East Building Consultants

Georgia Home Inspection Services

HOME INSPECTION REPORT

The Uniform Building Inspection Report Condensed

A Residential Owner s Guide to PERMITS. Elgin CITY OF PLANNING & NEIGHBORHOOD SERVICES

Saint Cloud Business Center

Crawford Inspection Services C.C.B. #

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

WARRANTIES AND PERFORMANCE STANDARDS T A B L E O F C O N T E N T S General Provisions Introduction Warranties Effective Date of Warranties Exclusive

SITE INSPECTION CHECKLIST

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Inspection Report. Prepared for: William Smith 2700 New Street Plano, TX 75025

SAMPLE INSPECTION REPORT PREPARED FOR: John Q Public

159 Morningside Avenue, Toronto

COMPANY NAME CONTACT NAME TELEPHONE NUMBER DENIAL REASON APPLICANT S MAILING ADDRESS: CITY STATE COUNTY ZIP TELEPHONE

Structure Survey Findings:

2010 Residential Water Heater Replacement Check List

PRE-OWNED MOBILE / MANUFACTURED HOME PRE-INSPECTION

Summit Series Single Section and Double Section Homes

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

New Home Walk-Through Package

Cossio Insurance Agency Fax: PO Box 188 Simpsonville SC 29681

Four Point Insurance Inspections *A Home Inspection is NOT a 4 Point Inspection

EL LAGO BUILDING DEPARTMENT PERMIT ISSUANCE PROCEDURES As of February 20, 2013

The City of Basehor, Kansas

STATE OF SOUTH CAROLINA RESIDENTIAL PROPERTY CONDITION DISCLOSURE STATEMENT

General Earthquake Damage Inspection Checklist

Dream It. FInance It. BuIlD It.

Mark Cramer Inspection Services, Inc.

FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES CITY FIRE PROGRAM UNDERWRITING ITEMS OF IMPORTANCE

Aztec Property Inspections 2719 Mission Blvd San Diego, CA (858) Some Road San Diego, CA 92114

Does Wall Township require an inspection by the building department on resale of a home?

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

Transcription:

tpatrick@ispects.me Tampa Bay Area: Southwest Florida: (813) 368-6407 (239) 896-3986 Four Point Inspection Izzo, Frank & Jacqueline 3214 Williamsburg Street Sarasota, FL 34231 9/26/2013 Note to Policyholder: Questions regarding the results of this inspection should be directed to a member of our Quality Assurance team by dialing any one of the numbers listed above, or by simply emailing us at tpatrick@ispects.me. Questions regarding the impact of this inspection and your insurance coverage or premiums should be directed to either your trusted insurance agent or your insurance carrier. Limitation of Liability: ispects inspections are purely observational in nature and are based upon the accessible areas of the structure as well as any available documentation provided to the inspector during the time of inspection. ispects is solely verifying the condition of the items listed on this Four Point form, and makes no warranty, express or implied, regarding the suitability or condition of the main structure under any circumstances.

General Information: Client s Name: Izzo, Frank & Jacqueline Client s Phone: Property Address: 3214 Williamsburg Street City: Sarasota State: FL Zip: 34231 Structure Detail: Construction: 90 % Masonry & 10 % Wood Frame Foundation: Slab On Grade Number of Stories: 1 Approximate Size: 1487 Sq Ft Year Built: 1966 Inspector Info: Date of Inspection: 9/26/2013 Inspector s Name: Mark Sawyer FL License #: HI 5095 I CERTIFY THAT I PERSONALLY INSPECTED THE PREMISES AT THE LOCATION ADDRESS LISTED ABOVE ON THE INSPECTION DATE NOTED. I CERTIFY THAT THE ABOVE STATEMENTS ARE TRUE AND CORRECT. Elevation Photos Front Elevation Right Elevation Back Elevation Left Elevation

1. Heating & Cooling 1.1 Heating System Type: Package Unit 1.2 Overall Heat System Condition: Good 1.3 Estimated Heating System Age: 2011 1.4 Central AC System Quantity: 1 1.5 Overall Central AC System Condition: Good 1.6 Estimated Central AC System Age: 2011 1.7 Estimated Remaining Life of Central AC: 10-12 Years 1.8 Window Unit Quantity: 0 1.9 Overall Window Unit Condition: N/A 1.10 Average Window Unit(s) Age: N/A 1.11 Estimated Remaining Life of Window Units: N/A 11 106881 00 B0 Sarasota County Mechanical Permit 03/01/2011 Package Unit Compressor ID 2 ½ Ton Package Unit Package Unit

2. Plumbing 2.1 Bathroom Quantity: 2 2.2 Main Supply Line Material(s): Copper & CPVC 2.3 Main Supply Line Condition: Good 2.4 Main Waste/Vent Material: PVC 2.5 Fixture Supply Updated: Yes 2.6 Estimated Fixture Supply Age: 2005 2.7 Fixture Drain Line Material(s): Copper & CPVC 2.8 Overall Fixture Drain Line Condition: Good 2.9 Fixture Drain Updated: Yes--2005 2.10 Shutoff Valves Present: Yes 2.11 Water Heater location: Garage 2.12 Hot Water Source: Conventional Tank 2.13 Hot Water Power Source: Electric 2.14 Estimated Age of Water Heater: 1999 2.15 TPR Valve Present: Yes 2.16 Evidence of Polybutylene: No Plumbing System Estimated Remaining Life: 10 + Years 30 Gallon Hot Water Tank Supply Lines & TPR Valve Laundry Supply Lines Kitchen Supply & Drain Lines W/ Shutoffs

3. Roof 3.1 Roof Shapes: Gable & Flat 3.2 Roof Material(s): (1) Dimensional Asphalt Shingles (2) Built-Up/Rolled Asphalt 3.3 Number of Shingle Layers 1 3.4 Overall Sloped Roof Condition: Good 3.5 Approximate Age of Sloped Material: 2005 3.6 Estimated Remaining Life of Sloped Roof: 10-12 Years 3.7 Overall Flat Roof Condition: Good 3.8 Approximate Age of Flat Material: 2005 3.9 Estimated Remaining Life of Flat Roof: 6-9 Years 3.10 Roof Sheathing Type: Dimensional Lumber/Planks 3.11 Overall Sheathing Condition: Good 3.12 Evidence of Roof Covering Damage: No 3.13 Evidence of Water Intrusion: No 05 412089 00 B0 04/15/2005 Sarasota County Roof Permit Roof 1 Roof 2 Roof 3 Roof 4

4. Electrical 4.1 Service to Dwelling: Overhead 4.2 Main Disconnect Location: Interior Panel 4.3 Main Disconnect Amperage: 100 Amps 4.4 Amperage Sufficient: Yes 4.5 Branch Wiring Type(s): Copper 4.6 Exterior Panel(s) Type: Meter Only - No Panel 4.7 Overall Exterior Panel Condition: N/A 4.8 Exterior Panel Updated: N/A 4.9 Approximate Age of Exterior Panel: N/A 4.10 Exterior Panel Grounded: Yes 4.11 Interior Panel(s) Type: Circuit Breakers 4.12 Overall Interior Panel Condition: Good 4.13 Interior Panel Updated & Year: Yes--2005 4.14 Approximate Age of Interior Panel: 1966 4.15 Active Knob & Tube Wiring: No 4.16 Exposed or Unsafe Wiring: No 4.17 AFCIs Present: No 4.18 GFCIs Present: Yes Electrical System Estimated Remaining Life: 10 + Years Electrical Service Entry Murray 100 Amp Main Breaker Electrical Panel W/ Door Breakers W/ Branch Wiring