90-Day Testing Report: December 2004 March 2005. Off-Site Interim Remedial Measure, Former Unisys Facility, Great Neck, New York

Similar documents
August 22, Warning Letter, August 3, 2008 Incident Former American Beryllium Company Site 1600 Tallevast Road, Tallevast, FL OGC #

Remediation of VOC Contaminated Groundwater

New Cumberland Army Depot Formerly Used Defense Site (FUDS) Marsh Run Park Site Restoration Community Meeting

4 th & Carey Groundwater. Remediation Project and Reverse Osmosis Water Treatment System

Description Purpose Health Education. Health Assessment. Outcomes of the program Partners Contact Information

Flying Cloud Sanitary Landfill

SUCCESSFUL FIELD-SCALE IN SITU THERMAL NAPL REMEDIATION AT THE YOUNG-RAINEY STAR CENTER

Frequently Asked Questions FAQ (click to follow link) How Does The Thermal Well System Work? How Much Does It Cost?

Imagine the result. First Quarter 2009 Corrective Action Progress Report. Lockheed Martin Corporation

Utilizing an Innovative, Effective Site Assessment and Monitoring Tool

Biofilter Treatment System at the East Kingston Septage Facility

(Adopted July 7, 1989)(Amended December 7, 1990) (Amended May 13, 1994) FUGITIVE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS

PCE, TCE, and TCA Vapors in Subslab Soil Gas and Indoor Air: A Case Study in Upstate New York

Mitigating Vapors at the Atlantic Highlands Elementary School, New Jersey. Lenny Siegel Center for Public Environmental Oversight October, 2009

INFO TECH: ENVIRONMENTAL CONCERNS

Alternate Concentration Limits/Groundwater Cleanup Levels. Title slide

Pennsylvania Marcellus Shale Short- Term Ambient Air Sampling Project

ETV JOINT VERIFICATION STATEMENT

In Situ and Ex Situ Bioremediation Technologies for Groundwater Contaminated with Chlorinated Solvents

Soil and Groundwater. Removing Contaminants. Groundwater. Implementing. Remediation. Technologies 1 / 6

SOIL AND GROUNDWATER MANAGEMENT PLAN For Site Located at 420 South Avenue Rochester, New York NYSDEC Spill No PREPARED FOR: PREPARED BY:

Drinking Water Treatment Using Air Strippers

Soil remediation you can trust In Situ Thermal Desorption. The real ISTD TERRATHERM R TECHNOLOGY. Technology

In Situ Bioremediation of Chlorinated Solvent R&D 100 Award Winner

Green Remediation via an Enhanced In Situ Bioremediation Solar-Powered System

Presumptive Remedy: Supplemental Bulletin Multi-Phase Extraction (MPE) Technology for VOCs in Soil and Groundwater Quick Reference Fact Sheet

A Comparison of EPA Methods 8260B and TO-14A/15 for the analysis of VOCs in Soil Gas: Application to Upward Vapor Intrusion Risk Studies

Enhanced In Situ Biodegradation of Trichloroethene/1,1,1 Trichloroethane in Fractured Rock Groundwater

VOCs Ambient Air Monitoring Report

U. S. Army Corps of Engineers Ground Water Extraction System Subsurface Performance Checklist

State of Rhode Island Department of Environmental Management Division of Site Remediation. Policy Memo 95-01

SEAR Wastewater Treatment: Contaminant Removal and Material Recovery

CHAPTER 7: REMEDIATION TECHNOLOGIES FOR CONTAMINATED GROUNDWATER

24 September 2008, 0930 Hours

Health Consultation. Report on the Feasibility of a Multi-site Analytic Follow-up Study

STATEMENT OF BASIS HYPERGOL SUPPORT BUILDING SWMU 65 NATIONAL AERONAUTICS AND SPACE ADMINISTRATION KENNEDY SPACE CENTER BREVARD COUNTY, FLORIDA

TORONTO MUNICIPAL CODE CHAPTER 423, ENVIRONMENTAL REPORTING AND DISCLOSURE. Chapter 423 ENVIRONMENTAL REPORTING AND DISCLOSURE

DRAFT. GROUNDWATER REMEDY COMPLETION STRATEGY: Moving Forward with Completion in Mind

Vapor Intrusion in New York City Greenpoint: The Tip of the Iceberg

Letter Health Consultation

Capability Statement

SAT Initiative: Young Scholars Academy (Houston, TX)

MARYLAND DEPARTMENT OF THE ENVIRONMENT 1800 Washington Boulevard Baltimore Maryland

Long-Term Monitoring Network Optimization Evaluation. for. Wash King Laundry Superfund Site Lake County, Michigan

Permitting Procedures Manual. Soil/Groundwater Remediation

City: CROYDON TOWNSHIP CROYDON TCE. Site Information: Record of Decision (ROD): CROYDON TCE CROYDON TOWNSHIP, PA. Site Name: Address:

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

Pierre VOC Ground Water Investigation and MTBE Remediation Pilot Study

Well gauging results LNAPL in Benzol Processing Area

How To Treat A Contaminant Plume

FUEL QUALITY REPORT BIOCNG GAS ANALYSIS NOVEMBER 2012

SOIL GAS MODELLING SENSITIVITY ANALYSIS USING DIMENSIONLESS PARAMETERS FOR J&E EQUATION

Emission Testing February 2015 LMS Energy Pty Ltd - Jilliby Plant

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

TCE. The Use & Remediation of TCE at NASA. Keep reading. is developing innovative. NASA s pollution prevention efforts significantly reduced TCE use

Why In Situ Thermal Desorption Can Be the Most Cost-Effective Remediation Method for Many Sites

M Area Inactive Process Sewer Lines (MIPSL) Operable Unit CAB Recommendation #236 Update

Secondary Containment Systems for Aboveground Storage Tanks

FIVE-YEAR REVIEW REPORT MASON COUNTY LANDFILL SUPERFUND SITE LUDINGTON, MICHIGAN FEBRUARY, 2001

2013 Rhode Island Pollutant Discharge Elimination System Remediation General Permit

NASA Stennis Space Center Environmental Resources Document

New Jersey Private Well Water Test Reporting Form

Environmental and Economical Oil and Groundwater Recovery and Treatment Options for hydrocarbon contaminated Sites

In-situ Bioremediation of Chlorinated Hydrocarbons An Assessment of Projects in California

2142 Priest Bridge Court Suite 1 Crofton, Maryland (800) FAX (410) Figure 1.

APPLICABILITY INTRODUCTION METHODS FOR TRACKING RECYCLED ROC WASTE

Long-Term Groundwater Monitoring Optimization Taylor Road Landfill Superfund Site Seffner, Hillsborough County, Florida

4.1 Dry Cleaning General 1,2

CREATING A GREEN FUTURE THROUGH WATER REMEDIATION

THIS PAGE LEFT INTENTIONALLY BLANK. flr300297

SPDES PRIVATE, COMMERCIAL, INSTITUTIONAL GENERAL PERMIT FOR SANITARY WASTEWATER DISCHARGES TO GROUNDWATER FACT SHEET

SHORT INSTRUCTIONS: END OF SHORT INSTRUCTIONS

Identifying Environmental Aspects

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Summary of Regulatory and Mandatory Timeframes for Remediation 1

In Situ Bioremediation Operations and Maintenance Plan for Test Area North Final Groundwater Remediation, Operable Unit 1-07B

Cost-Effective Bioremediation of Perchlorate in Soil & Groundwater

MEMORANDUM. Long-Term Monitoring Optimization Review Intel Magnetics/Micro-Storage Corporation Site, Santa Clara, CA

Inventory of Performance Monitoring Tools for Subsurface Monitoring of Radionuclide Contamination

Mark A. Lehar, P.Geo. Regional Environmental Lead and Senior Environmental Geologist

NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM

Instructions to Remedial Party / Remedial Party Consultant

Drill-Right. best Oil & Gas Development Practices for Texas

GRANULAR ACTIVATED CARBON FOR WATER & WASTEWATER TREATMENT

Data Management Systems for Wastewater

Vapor Phase Transport as a Groundwater Contamination Process at Arid Landfill Sites

Operations, Maintenance, and Monitoring Plan

11 September 2002, 0930 Hours

ENCLOSURE 2 AP-42 EMISSION FACTOR BACKGROUND DOCUMENTATION PRESSURE SENSITIVE TAPE AND LABEL SURFACE COATING OPERATIONS

PILOT PROJECT TO OPTIMIZE GROUND WATER REMEDIATION SYSTEMS AT RCRA CORRECTIVE ACTION FACILITIES: SUMMARY REPORT AND LESSONS LEARNED

3-D Data Visualization Taking the Next Step in Data Presentation

FINAL REPORT DETAILED FIELD INVESTIGATION OF VAPOR INTRUSION PROCESSES. ESTCP Project ER-0423

Off-Gas Treatment Technologies for Soil Vapor Extraction Systems: State of the Practice

Draft Data Validation Plan Review Form Tier II

Remediation System Evaluation (RSE) Alaric, Inc. Superfund Site Tampa, Florida

FACTS in Drinking Water

2015 Mehrdad Javaherian, Ph.D., MPH, PE, LEED GA

Health Consultation SUNOCO REFINERY CITY OF OREGON, LUCAS COUNTY, OHIO EPA FACILITY ID: OHD AUGUST 1, 2005

How To Make A High Co 2 Gas Blend

In-Situ Bioremediation of Organic Compounds: Coupling of Mass-transfer and Biodegradation

Transcription:

90-Day Testing Report: December 2004 March 2005 Off-Site Interim Remedial Measure, Former Unisys Facility, Great Neck, New York NYSDEC Site ID # 130045

90-Day Testing Report: December 2004 March 2005 William S. Wittek, P.E. Senior Engineer Off-Site Interim Remedial Measure Former Unisys Facility, Great Neck, New York NYSDEC #130045 Nicholas Valkenburg Project Director Prepared for: Lockheed Martin Corporation Prepared by: ARCADIS G&M, Inc. 88 Duryea Road Melville New York 11747 Tel 631 249 7600 Fax 631 249 7610 Our Ref.: NY001227.1905.00001 Date: 31 March 2005 This document is intended only for the use of the individual or entity for which it was prepared and may contain information that is privileged, confidential, and exempt from disclosure under applicable law. Any dissemination, distribution, or copying of this document is strictly prohibited.

Table of Contents Introduction 1 System Description 1 Summary of Testing Activities: December 2004 through March 2005 2 90-Day Test 2 Results 3 Discussion 3 References 5 Tables 1 Summary of Influent Water Sample Analysis Results, 90-Day Testing, Off-site Interim Remedial Measure (IRM), Former Unisys Facility, Great Neck, New York. 2 Summary of Effluent Water Sample Analysis Results, 90-Day Testing, Off-site Interim Remedial Measure (IRM), Former Unisys Facility, Great Neck, New York. 3 Summary of Effluent Vapor Sample Analysis Results, 90-Day Testing, Off-site Interim Remedial Measure (IRM), Former Unisys Facility, Great Neck, New York. 4 Regulatory Status of Air Emissions for the Off-site Interim Remedial Measure, Former Unisys Facility, Great Neck, New York. Figures 1 Site Location Map, Off-Site Interim Remedial Measure, Former Unisys Facility, Great Neck, New York. 2 Site Plan, Off-Site Interim Remedial Measure, Former Unisys Facility, Great Neck, New York. 3 System Schematic, Off-Site Interim Remedial Measure, Former Unisys Facility, Great Neck, New York. dec 2004 - march 2005.doc i

Introduction This report has been prepared to meet the reporting requirement specified in the Interim Remedial Measure (IRM) Work Plan dated December 9, 2002 for the Off-site Remediation System at the former Unisys Facility in Great Neck, New York and the Site Access and Licensing Agreement between Lockheed Martin Corporation and Great Neck Union Free School District (GNUFSD), dated April 14, 2003. A site location map is provided on Figure 1. This report is the second testing report prepared for the Off-site Remediation System, and summarizes the 90-day testing activities and associated data collected between December 2004 and March 2005. System Description The Off-site Remediation System consists of the following major components: One groundwater recovery well (RW-100) located and designed to efficiently capture and contain off-site, volatile organic compound (VOC) impacted groundwater; Air stripper system designed to reduce the concentration of VOCs in the recovered groundwater to non-detect performance standards per the approved Off-site IRM Work Plan prior to re-injection back into the Magothy aquifer via diffusion wells. Three diffusion wells (DW-100, DW-101, and DW-102) designed and located to assist with the re-injection of treated water and the prevention of further migration of off-site VOC-impacted groundwater; and Air stripper off-gas (i.e., vapor emission) treatment system designed such that the effluent vapor will meet non-detect performance standards in the Access Agreement with the Great Neck School District. During operation, groundwater, impacted by VOCs, is extracted from the subsurface aquifer, pumped to the Off-site Remediation System for treatment, and is then recharged back to the aquifer. Specifically, the extracted groundwater is pumped from one recovery well (RW-100), through two air strippers, which are arranged in a series configuration, to remove the VOCs from the groundwater. The treated groundwater is dec 2004 - march 2005.doc 1

then pumped through a subsurface pipeline to three diffusions wells (DW-100 through DW-102) where it is re-injected back into the aquifer. During the air stripping process, the VOCs are transferred from the water (which enters the air strippers at the top) to the counter-current air stream (which enters the air strippers at the bottom). The air stripper off-gas vapor (i.e., the VOC-laden air stream) is then treated by four emission control units filled with Vapor Phase Granular Activated Carbon (VPGAC) to remove the VOCs prior to discharge to the atmosphere. A site plan of the Off-site Remediation System is shown on Figure 2 and the Process Schematic, showing sampling locations and designations, is provided on Figure 3. Tables 1 through 3 present results of the performance testing activities completed during this period. Summary of Testing Activities: December 2004 through March 2005 The initial system testing activities, which consisted of a 24-Hour, 5-Day, and 4-Week test, were conducted between July and October 2004; a summary of testing activities performed during the initial testing period along with performance testing results are described in the Initial Testing Report (ARCADIS 2005a). This report describes activities conducted and data collected during the 90-Day Test (conducted between December 2004 and March 2005). The 90-Day Test is described in detail below. 90-Day Test The 90-Day Test was initiated on December 6, 2004 and was completed on March 10, 2005. The activities conducted during the 90-day test consisted of the following: System on-site inspections were performed weekly. The system operation was monitored remotely on a daily basis. Weekly compliance vapor and water samples were collected on December 13, 20, 29, 2004; January 3, 10, 17, 24, 31, February 7, 14, 21, 28, and March 7, 2005, at the end of the seventh, fourteenth, twenty-third, twenty-eighth, thirtyfifth, forty-second, forty-ninth, fifty-sixth, sixty-third, seventieth, seventyseventh, eighty-fourth, and ninety-first days of operation, respectively. A summary of compliance vapor and water sample results, arranged by sampling location, is provided in Tables 1 through 3. Figure 3 shows the sampling locations and sample designations. dec 2004 - march 2005.doc 2

Results There are several VOC compounds that are present in the groundwater extracted from Recovery Well 100 (RW-100). The first group of compounds was anticipated and the treatment plant was designed to reduce their concentrations to meet the Non-Detect Performance Standard (Table 1). These compound are 1,1-dichloroethene (1,1-DCE); 1,1-dichloroethane (1,1-DCA); cis-1,2-dichloroethene (1,2-DCE); trans-1,2- dichloroethene (1,2-DCE); chloroform; 1,2-dichloroethane (1,2-DCA); 1,2- dichloropropane; trichloroethene (TCE); tetrachloroethene (PCE); and trichlorotrifluoroethane (Freon 113). The second group of compounds was not anticipated, and consists of dichlorodifluoromethane (Freon 12); chlorodifluoromethane (Freon 22); and vinyl chloride (Table 1). Except for the vinyl chloride the presence of the VOCs in this second group (i.e., Freon 12 and Freon 22) was not addressed in the Off-site IRM Workplan or the Access Agreement with the School District. Table 2 shows that all the VOC compounds, including those compounds in both groups, are effectively removed from the water by the air strippers. The water being re-injected into the ground via the diffusion wells contains no detectable concentrations of VOCs, thus it meets the Non-Detect Performance Standard in the Access Agreement with the School District. Table 3 shows that only five of the 42 compounds being tested for in vapor are being emitted to the air at very low concentrations. Chloromethane and Methylene Chloride have been intermittently detected, although they were not detected in the influent water to the plant. Vinyl chloride has been detected at levels slightly above the Non-Detect Performance Standard, but it was also not detected in the influent water. In addition, both Freon 12 and Freon 22 were detected, but both these compounds are present in the influent water to the plant. Discussion Even though chloromethane is present in the air discharge from the system, it is also present, at similar concentrations, in the ambient/background air, as discussed in the Initial System Testing Report (see Tables 4 and 5 in ARCADIS 2005a). Since the ambient levels are higher than the Non-Detect Performance Standard, it is not necessary to meet the Standard since the discharges would then be cleaner than the ambient air. In any event, the discharge of chloromethane is only 5.5x10-3 % and 8.2x10-4 % of the New York State Department of Environmental Conservation dec 2004 - march 2005.doc 3

(NYSDEC) short-term guideline concentrations (SCG) and the annual guideline concentrations (AGC), respectively (Table 4). Based on available data, all of the Freon 22 being discharged appears to originate in the groundwater being pumped to the plant. The ambient/background level of Freon 12 (see ARCADIS 2005a) appears to be approximately 3 ug/m 3 and the air discharge levels from the plant are typically around 6 ug/m 3, leading to the conclusion that about 50% of the Freon 12 originates in the groundwater and the other 50% is from the ambient air. Regardless, the vapor discharge concentrations of both compounds (Freon 12 and 22) are small fractions (3.1x10-5 %and 1.1x10-4 %) of the NYSDEC AGCs of 12,000 and 50,000 ug/m 3, respectively (no SGCs have been established for these compounds) (Table 4). In addition, air modeling conducted at the request of the NYSDEC and New York State Department of Health (NYSDOH) (ARCADIS 2005b) indicates that, taking into account air dispersion effects, the concentration of both compounds would be several orders of magnitude below the NYSDEC standards by the time these compounds would reach the school district property and nearby residential area and, therefore, would be undetectable by the analytical method used. ARCADIS extensively investigated treatment technologies for the Freon compounds at the very low levels being detected. The results of the investigation show that viable, proven treatment technologies do not exist at this time. Even though the vinyl chloride was not detected in the influent to the plant, all of the mass being discharged appears to originate in the groundwater. The likely reason is that the vinyl chloride concentration in the groundwater is too low to be detected. Regardless, the discharge levels for vinyl chloride are only well below the SGC and only at 0.79% of AGC. Nevertheless, since this compound is above the Non-Detect Performance Standard, it will addressed by modifying the treatment system to reduce its concentration. Lockheed Martin and its consultants are in the process of evaluating various treatment options for vinyl chloride in off-gas vapor emissions. Even though methylene chloride was detected in the discharged air during the January 10, 2005 sampling event, ARCADIS believes that because it is a common laboratory contaminant and was only detected once during the 90-Day Test, the constituent was not present in the discharged air. dec 2004 - march 2005.doc 4

References ARCADIS 2005a Initial Testing Report: July October 2004 Off-Site Interim Remedial Measure, Former Unisys Facility, Great Neck New York. NYSDEC ID #130045. ARCADIS 2005b Freon 22 Emission Modeling, Off-Site Remediation System, Former Unisys Corporation, Great Neck, New York, Letter dated 3 March 2005. dec 2004 - march 2005.doc 5