Basic, Slim & Slim Square Water heater

Similar documents
Isotemp Basic, Slim/B & Slim Square

Operators manual Basic water heater

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Oil and Coolant Circulating Heating System. Model - OCSM

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Cooling system components, removing and installing

Installation and Operating Instruction Manual

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Electric Mini Tank Water heaters GL GL 4 - GL 6+

Solstice/Sky Water Pump Replacement

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Draining and filling cooling system

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Stainless Steel Single and Dual Circulation Kits

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

SELECTION, APPLICATION AND MAINTENANCE

SunMor SM-V30 Solar Water Heater Installation Manual

VOYAGER 570G. 744A Sprayer Control

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Fixtures - Parts - Accessories to shampoo bowls

Cooling system components, removing and installing

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

ALL IN ONE. Heat Pump Water Heater

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

SF15K SF05KSS, SF10KSS

PWC-500/1000/1010/1500

Installation Instructions

ELECTRIC WATER HEATERS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

INSTALLATION INSTRUCTIONS

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

Light Duty Commercial Electric Water Heater

Cooling system components, servicing

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

VS CONTROL PACK INSTALLATION INSTRUCTIONS

Mini USB and USB 2.0-IP67 Connector System

Volkswagen Golf > VW Rabbit GTI 2006->

Installation and maintenance instructions

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Installation Instructions

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Compressor Service & Maintenance Manual

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Cleaning & Sanitisation

Commercial Electric Water Heater

Electric Mini Tank Water Heaters

Aquamax Australia Pty Ltd ABN

400 Series - Mini USB Buccaneer

Installation Instructions S

PC1130 Electric Air Compressor

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Standard Buccaneer - USB

H41 Electrical Stage Aft Air Conditioner Unit Installation

Overheating limit control

Alfa Romeo 147 On board instruments installation guide

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Air Conditioner Water Heater Model ACWH18

Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Marine Refrigerator/freezer CR 195 & CR 195 Stainless Steel-INOX

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Utility Distribution Systems

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

5800 Temperature Sensor Cable Assembly

Spare Parts List M96A.24SM/B M96A.28SM/B

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

FILLING AND PURGING THE SYSTEM

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Vacuum Tube Solar Water heater Non-pressure. User manual


Before installation it is important to know what parts you have and what the capabilities of these parts are.

COOLING SYSTEM Section Page

Model 5600SE Downflow

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

AIR LINE VALVES AND GAUGES

PC1131 Electric Air Compressor

Transcription:

Basic, Slim & Slim Square Water heater Installation and Operating Instructions IT-61019 S Agata Feltria (PU) Italy Phone 390541848030 Fax 390541848563 info@indelmarine.com www.isotherm.com Indel Marine USA, Inc. 53900 NW 12th Avenue Fort Lauderdale, FL 33309 Phone: (954) 772-8355 Fax: (954) 772-3839 www.indelmarineusa.com info@indelmarineusa.com

Table of contents 1. Locating the tank 2. Mounting 3. Connections 3.1 Fittings 3.2 Hoses 3.3 Connections to engine 3.4 Freshwater system connection 3.5 Electrical connections 4. Start up/test 5. Maintenance 5.1 Winterization 5.2 Replacing thermostat 5.3 Replacing heater element 6. Double heat exchanger 7. Technical data 7.1 Basic 7.2 Slim & Slim Square

1. Locating the tank The water heater can be mounted anywhere on the vessel as long as the connections to the engine heat exchanger are below the engine header tank (Fig. 1). It is best to keep the length of the heat exchanger hoses short to keep flow resistance and heat loss to a minimum. In many installations the tank heat exchanger is simply connected in series with the engine coolant circuit. In some installations it is connected in parallel with a flow restrictor/diverter. The choice depends on the specific recommendations of the engine manufacturer and or installer. Please consult the manufacturer or dealer of your engine for any recommendations they may have for connecting to the engine cooling system. 2. Mounting The Isotemp Basic, Slim & Slim Square water heaters are designed to give excellent performance when mounted horizontally and vertically. The drain / safety valve must always be at the lowest point. The mounting brackets can be adjusted to the side on Basic and Slim for mounting the tank on a bulkhead. Always mount the tank to a suitable shelf or bulkhead and keep in mind the extra weight of the tank when it is full of water. Fig. 2 Slim, Fig. 3 Basic and Fig. 4 Slim Square Slim Fig. 2 Cold water in - Warm water out

WATER OUT A CALDA Type: Voltage: 230 V Power: 750 W Capacity: 24 L Pressure relief valve: 4.0 bar Heat exchanger max. 0.7 bar IT-61019 S. Agata Feltria (PU) Italy S/N: E-mail: info@indelmarine.com www.indelmarine.com K V Isotemp Basic Isotemp Basic Double heat exchanger Basic - - WARM OUT MOTOR ENGINE WATER MOTOR ENGINE WATER MOTOR ENGINE WATER Basic MOTOR ENGINE WATER FRESH COLD WATER IN in or out Cold water in Second heat exchanger Cold water in Fig. 3 Slim Square 45 45 Warm water out 0-90 Alternative positions Slim Square 45 45 Fig. 4 Cold water in

3. Connections 3.1 Fittings Use good quality fittings to make all connections. Bronze, stainless steel and corrosion resistant brass alloys are recommended. Most plastic fittings will not withstand high temperatures and are not recommended. All US tanks use ½ female BSP or NPT threaded coupling that will mate with ½ male NPT adaptors. Use a curing pipe sealant on the threads such as Loctite PST 592 or equivalent to insure a leak-free connection. 3.2 Hoses Use hoses rated for use with engine coolants and high temperature of 210 F for connections to the heat exchanger. Hoses used for water system should be rated at 125 psi and approved for use with portable water systems, and food industry quality is preferred. 3.3 Connections to engine Isotemp water heaters may be used with either fresh or raw water-cooled engines. For good results an operating temperature of 140 F to 185 C is recommended. The heat exchanger requires a flow of ½ a gallon per minute for efficient heating of the water in the tank. Please follow recommendations of the engine supplier for how to make the connections to the engine cooling system. Keep the diameter of the fittings and hoses large enough to maintain low flow resistance. 5/8 (16 mm) is a very common size for these hoses. 3.4 Freshwater system connection The water tank inlet is normally fed from the water system electrical pressure pump. The pressure switch on the pump should be adjusted to maximum 60 psi (4 bar). Please note that the pressure relief valve on the tank is set to 80 psi (5.5 bar). If the system setting goes above this setting the relief valve will open and water will be released to the drain. The tank is fitted with a tempering valve, also called a thermostatic mixing valve, that will mix cold water with hot water to reduce the temperature to a safe level. This temperature can be adjusted with the knob mounted on the side ( Fig. 5) Adjust this counterclockwise to increase the temperature of the water. Temperature range: 100 F to 150 F. All hot water taps on the boat should be a mixer type that will allow for mixing of cold and hot water at the tap. Thermostat mixing valve Fig. 5 - Temp. The drain valve is integrated into the pressure relief valve and is mounted at the bottom of the tank. A 3/8 hose can be fitted to the drain outlet. A small quantity of water can drain from the relief valve as the tank is heated.

Type: Voltage: 230 V Power: 750 W Capacity: 24 L Pressure relief valve: 4.0 bar Heat exchanger max. 0.7 bar IT-61019 S. Agata Feltria (PU) Italy S/N: E-mail: info@indelmarine.com www.indelmarine.com ACQUAMOTORE K ACQUAMOTORE V ACQUAMOTORE USCITA AQUA CALDA 3.5 Electrical connections See wiring diagram Fig. 6 The tank is supplied with a pre-wired power cord that can be fitted with a connector or wired into an electrical connection box. All US tanks are supplied with a 750 W 120 VAC heating element. Current draw on this circuit will be 7 to 8 amps. Please protect this circuit with an appropriate sized circuit breaker. Recommended wiring: good quality 12/2 tinned duplex boat wire, AWG 12. Always unplug the heater and/or turn off all circuit breakers and disconnect shore power connections before removing the connection cover. The electrical circuit is controlled by a service thermostat set to 167 F (75 C) and a double overheat protector that is set to 205 F (96 C). If the overheat protector trip, it has to be manually reset. This is done by pressing the small knob on top of the overheat protector. Unscrew the white cap first. See Fig. 7 Wiring diagram Wiring diagram Electrical heater element Thermostat Over heat protection White Black Green Fig. 6 L N 000746 Isotemp Basic Service thermostat Over heat protector, push button Isotemp Slim & Slim Square Service thermostat FRESH WARM WATER OUT Basic Safety valve 80 psi with drain. Over heat protector, push button to re-set Safety valve 80 psi with drain. Service thermostat Safety valve 80 psi with drain. Fig. 7 000715 000792-US 000746

Important! The water heater shall be connected to the mains power supply only when it is in service. When leaving the boat for any length of a period, it is recommended to pull out the cable connector from the socket to also disconnect the earth protection. This should be done even if the shore power system is shut off, as there can be a potential difference, between the earth from shore and the sea water earth of the boat. This can seriously damage, by stray current corrosion, the immersion heater, water heater tank or the engine with its drive unit. Installation of a insulation transformer in the shore power equipment eliminates the risk of galvanic corrosion via the shore power connection. 4 Start up/test Fill the hot water tank by turning on the water pressure pump and opening a hot water tap to allow air to bleed out of the hoses and / or plumbing. Check the drain and pressure relief valve by pushing the lever. Water will flow into the drain hose. Make sure the drain hose is not blocked or closed. Pull the lever back to closed position. Start the engine to check the circulation of the coolant. It will be necessary to add coolant to the system to compensate for the additional volume of the exchanger and hoses. Check for air locks in the connecting hoses and raise and lower these as necessary to clear the air from the hoses before securing the hoses in place. Lastly plug in the tank and turn on the circuit breaker. Check for proper operation. - 5. Maintenance 5.1 Winterization When there is a risk of freezing the tank must be drained. This is done by opening the air bleeder screw mounted on the mixing valve, take it away completely, (Fig. 8) and opening the drain valve by pushing the lever on the safety valve. (Fig 9). If the engine is raw-water cooled the heat exchanger must also be drained by removing the hoses and blowing air into the coils to drain any water. The tank can now be safely left in the vessel over the winter. When leaving the vessel for longer periods, it is recommended to take out the power cord to eliminate the risk of stray current from the shore power earth connections. Air bleeder screw Fig. 8 OPEN CLOSED Fig. 9

K V Type: Voltage: 230 V Power: 750 W Capacity:24L Pressure relief valve: 4.0 bar Heat exchanger max. 0.7 bar S/N: IT-61019 S. Agata Feltria (PU) Italy E-mail:info@indelmarine.com www.indelmarine.com 5.2 Replacing Thermostats Warning: Be sure to turn power off first! Take off the front plastic cover. The service thermostat and the overheat protector have the temperature sensor ends put into a tube on the electrical heater element bracket. See figure 7. Pull off cable shoes after having noticed the positions and unscrew the thermostat unit. Pull out the sensor end. Mount new thermostat in the opposite order. Be sure sensor end is properly put in to the tube. Basic 5.3 Replacing heating element Warning! Be sure to turn power off first! Drain the tank. A Fig. 10 B 000715 Basic And Slim Take off the plastic cover, unscrew the two screws at the sides and push the cover downwards. Dismantle the thermostat and the overheat protector from their brackets for better access on the Slim model. On Basic they can be left in position during the operation. Pull off the wires from the heating element tabs. Loosen the center nut, fig. 10-A, and take off the support, fig. 10-B. Put on the nut again on the center bolt for easier handling, better to grip by hand. Push off the rubber gasket inwards, it will come out together with the heater element unit. Turn the heater element unit 90 to the left, the wire tabs shall point to the right. Twist the unit until the inner end hits the tank to the left. Pull out the heater element unit through the hole with the left side first. Unscrew the heater element from the mounting flange. Mount the new heating element with new seal rings and a new big rubber gasket in the opposite order to the description above. The inner end of the heating element shall point downwards after assembly. Slim Square The heating element unit is on the Square model fastened by 6 screws on a flange which is fastened into the tank. It has a rubber gasket. Fig. 11 First, pull off the wires from the heating element tabs. Loosen all 6 screws, the heating element unit including the flange can be pulled out. The heating element is fastened on the flange with nuts. Unscrew the heating element from the mounting flange. Mount the new heating element with new seal rings and a new big rubber gasket. The inner end of the heating element shall point downwards after assembly. Fig. 11 000792

6. Double heat exchanger, Basic 11 & 20 gal. Double heat exchanger water heaters have connections for second heat exchanger located also on the front, side by side with ordinary heat exchanger connections. See fig. 3 7. Technical data and dimensions 7.1 Basic Type Volume gal. L x D x H inch Weight lbs. Heater element 602421B000003 6.4 19-15/16 x 15-3/8 x 15-1/2 30.8 120V - 750W 603023B000003 8 21-13/16 x 15-3/8 x 15-1/2 37.5 120V - 750W 604021B000003 11 26 x 15-3/8 x 15-1/2 44 120V - 750W 604023BD00003 Double heat exch. 11 26 x 15-3/8 x 15-1/2 48.5 120V - 750W 605021B000003 13 30-11/16 x 15-3/8 x 15-1/2 50.7 120V - 750W 607521B000003 20 42-1/8 x 15-3/8 x 15-1/2 64 120V - 750W 607523BD00003 Double heat exch. 20 42-1/8 x 15-3/8 x 15-1/2 68.4 120V- 750W Material: Heat exchanger coil, storage tank and all connections: Stainless steel AISI 316 Outside cover and mounting brackets: Stainless steel AISI 304 Heater element: Nickel plated copper. Insulation: Polyurethane foam Safety valve: 80 psi / 5.5 bar The manufacturer reserves the right to change specifications without prior notice. Dimensions Basic 000757

K V ENGINEWATER INGRESSOACQUAFREDDA 7.2 Slim & Slim Square Type Volume gal. L x D x H inch Weight lbs. Heater element 601521S000003 4.0 21-1/4 x 11-1/4 x 11-5/8 23 120V-750W 602021S000003 5.3 26-1/4 x 11-1/4 x 11-5/8 25.3 120V-750W 602521S000003 6.6 30-7/8 x 11-1/4 x 11-5/8 30 120V-750W 601623Q000003 Square 4.2 22-1/4 x 7-3/16 x 15-3/4 33 120V-750W Material: Heat exchanger coil, storage tank and all connections: Stainless steel AISI 316 Outside cover and mounting brackets: Stainless steel AISI 304 Heater element: Nickel plated copper. Insulation: Polyurethane foam Safety valve: 80 psi / 5.5 bar The manufacturer reserves the right to change specifications without prior notice. Dimensions Slim 000758 Slim Square 7 3 16 22 1 4 18 15 16 14 15 16 15 18 3 4 4 16 3 22 5 8 000750-US4 2004.12.10/LLG Basic & Slim op. man USA