TECHNICAL RANGE. Pressure Control Valves Fast, Secure, Inexpensive

Similar documents
STABITHERM INSTALLATION & SERVICE BOOKLET

OWNER & INSTALLER MANUAL AND WARRANTY INFORMATION.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Aquamax Australia Pty Ltd ABN

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Float and Thermostatic Traps Series H, C and X

Almond Kitchen Sink Tap

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Liquorice Kitchen Sink Tap

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Almond Kitchen Sink Tap

Troubleshoot resources for homeowner

Owner s Manual. & Installation guide. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater

Installation, Maintenance, & Repair Series 4000B/LF4000B

Apricot Kitchen Sink Tap

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

SF15K SF05KSS, SF10KSS

Design Utility Lever Thermostatic Bath Shower Mixer

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Artisan Thermostatic Bath Shower Mixer

Owners Guide and Installation Instructions.

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

HS-901(A) BASIC STEAM HEATING SYSTEMS

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

INSTALLATION INSTRUCTIONS MK-8704

INSTALLATION INSTRUCTIONS BL-8704

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

Chill 4 Hole Bath Shower Mixer

1805 Series Relief Valves

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Operators manual Basic water heater

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Installation and Maintenance Instructions

A High Bill Usually Means a Leak

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

PHOENIX TAPWARE. Gloss. Shower/Wall Mixer RRP: $ Product Code: Available Finishes: GS780. Chrome MATCH WITH...

Apricot Kitchen Sink Tap

Installation Instructions

REPAIR AND MAINTENANCE MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

PLUMBING CARE AND REPAIR

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS H 50/80 & 100

Compressor Service & Maintenance Manual

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Geyser-R Heat pump water heater Installation manual

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Version: 1.0 TWO HANDLES INWALL WATERFALL FAUCET INSTALL GUIDE

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

HOT WATER HEAT PUMP MANUAL FOR ADVICE, REPAIRS AND SERVICE: CALL (AUSTRALIA) (NZ)

Unvented water heater

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

Owner s Guide and Installation Instructions

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Water Tec of Tucson Water Systems

Elson 10/15L Unvented Water Heater

Coolflo Safe Touch Shower Mixing Valve ST20015CP

When Should Examination Preparation Begin?

Assembly and instructions

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Owner s Guide and Installation Instructions Electric Water Heater

AIRE Thermostatic bath shower mixer Installation and operating instructions

Safe Touch TMV3 Thermostatic Shower ST10010CP

Electric Mini Tank Water heaters GL GL 4 - GL 6+

Pressure reducing valves. Guide of applications

AIR LINE VALVES AND GAUGES

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

GLOSS SOAP DISH PRODUCT CODE: FINISH: GS895 CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Refrigeration Basics 101. By: Eric Nelson

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Installation Instructions S

Southwest Florida Water Management District. Fix It for Less

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Transcription:

TECHNICAL RANGE Pressure Control Valves Fast, Secure, Inexpensive

Pressure Cotrol Valves (PCV) The pressure control valves effectively reduce high mains pressure, resulting in less water delivery at taps. The expansion relief pressure control functions are all situated on one spindle, so there is no chance of conflicting settings causing the valve to unnecessarily relieve pressure and thereby waste water. 90 80 70 60 L/Min 50 40 30 20 10 0 10 20 30 40 50 150 200 250 300 350 400 Flow Pressure MF1 20mm 400KPA PA3.132 MF3 22mm 400KPA PA6.342 MF3 15mm 400KPA PA6.341 MF2 15mm 400KPA PA4.331 Closy 20mm 400KPA PA1.1 Flow Pressure MF1 20mm 400KPA PA3.132 MF3 22mm 400KPA PA6.342 MF3 15mm 400KPA PA6.341 MF2 15mm PA4.331 400KPA Closy 20mm PA1.1 400KPA 10 20 30 40 50 150 200 250 300 350 400 16 20 24 26 28 38 48 54 60 64 70 74 22 28 32.5 36 38 50 60 68 76 82 88 92.5 18 22 24 26 28 38 44 50 56 60 66 70 14 18 20 24 26 36 42 48 52 57 62 66 16 22 26 29 32 44 56 64 74 80 86 92

KWIKFLO 400kPa system pressure with integral expansion relief valve. Stainless steel seat & strainer. PA1.1 CLOSY kpa system pressure with integral expansion relief valve and vacuum breaker. Stainless steel seat & strainer. PA1.1L CLOSY 200kPa system pressure with integral expansion relief valve and vacuum breaker. Stainless steel seat & strainer. PA1.1L+ MASTERFLO 1 400kPa system pressure with integral expansion relief valve. Stainless steel seat and strainer (double mesh). ¾ BSP male iron inlet and outlet cap and lining couplings. PA3.132 GEYSER VALVE PACK Consisting of 1 x PA3.132, 2 x PB6.302 and 1 x ¾ BSP female iron valvecock. PA3.132PK SANS198

MASTERFLO 1 400kPa system pressure with integral expansion relief valve. 22mm Copper to Copper. Stainless steel seat & strainer (double mesh). PA3.332 GEYSER VALVE PACK Consisting of 1 x PA3.332, 2 x PB6.303 and 1 x 22mm Copper to Copper inlet & outlet 22mm valvecock. PA3.332PK MASTER BOX With 1 x PA3.132, ballcock, funnel, box with lid, strainer, 2 x PB6.303 vacuum breakers. ¾ BSP inlet & outlet. PA5.1 MASTER METER BOX With 1 x PA3.132, ballcock, funnel, box with lid, 3 2 x PB6.303 vacuum breakers. Kent M /H Water Meter. PA5.1M MASTERFLO II kpa system pressure with integral expansion relief valve. 15mm Copper to Copper. Stainless steel strainer. SANS198

MASTERFLO II 200kPa system pressure with integral expansion relief valve. 15mm Copper to Copper. Stainless steel strainer. PA4.321 MASTERFLO II 400kPa system pressure with integral expansion relief valve. 15mm Copper to Copper. Stainless steel strainer. PA4.331 GEYSER VALVE PACK Consisting of 1 x PA4.331, 2 x PB6.301 and 1 x 15mm Copper to Copper valvecock. PA4.331PK MASTERFLO II 400kPa system pressure with integral expansion relief valve. Stainless steel seat & strainer (double mesh). 22mm Copper to Copper. PA4.332 GEYSER VALVE PACK Consisting of 1 x PA4.332, 2 x PB6.303 and 1 x 22mm Copper to Copper valvecock. Acetyl valve seat. PA4.332PK SANS198

MASTERFLO II kpa system pressure with integral expansion relief valve. 22mm Copper to Copper + 2 X PB6.303. Stainless steel strainer. Acetyl valve seat. PA4.712 GEYSER VALVE PACK Consisting of 1 x PA4.712, 2 x PB6.303 and 1 x 22mm Copper to Copper valvecock. Acetyl valve seat. PA4.712PK MASTERFLO II 200kPa system pressure with integral expansion relief valve. 2 X PB6.303. 22mm Copper to Copper. Stainless steel strainer. PA4.722 MASTERFLO II 300kPa system pressure with integral expansion relief valve. Stainless steel strainer, acetyl valve seat. 2 X PB6.303. 22mm Copper to Copper. PA4.732 SANS198

MASTERFLO III Available in 400kPa and 600kPa pressure ratings. Connection size: 15mm and 22mm for copper tube systems to facilitate ease and low cost installation. Excellent flow rates. Complete with expansion relief valve. Operating cartridge and expansion relief valve can easily be removed from the body. Hand removable working cartridge, no special tools required to service the valve. 15MM 400KPA PA6.341/ 22MM 400KPA PA6.342 400kPa system pressure with integral expansion relief valve. Copper to Copper SANS 198 Features and Benefits: Non-corrosive valve seat. No additional expansion relief valve required. Cannot use MLP or SLP for outside applications. This is applicable to PB6.341 (15mm) & PB6.342 I.T.O outlet. Integral expansion relief valve. Stainless steel strainer. Includes: Masterflo III pressure control valve. Integral expansion relief valve. 400kPa cartridge with stainless steel strainer. Copper to Copper inlet and outlet, 15mm & 22mm respectively. No special tools required to replace the cartridge. PPSU (polyphenylsulfone) valve seat. DZR brass die cast. Ø15mm Copper to Copper expansion outlet. System pressure: 400kPa. Maximum inlet pressure: 2500kPa. Spares: Replaceable cartridge C-PA6.832. Cap nut 64XS-22. Compression ring D-65XS-22. 120 80 Flow Pressure 200 MF3 15mm 400kPa 32 46 MF3 22mm 400kPa 44 64 L/min 60 40 300 400 500 58 68 76 78 90 20 600 82 108 0 200 300 400 500 600 Flow Pressure MF3 15mm 400kPa MF3 22mm 400kPa SPARE CARTRIDGE 400KPA 400kPa Pressure control valve cartridge spare part. C-PA6.832 SANS198

15MM 600KPA PA6.361/ 22MM 600KPA PA6.362 600kPa system pressure with integral expansion relief valve. Copper to Copper. SANS 198. Includes: Masterflo III pressure control valve. Integral expansion relief valve. 600kPa cartridge with stainless steel strainer. Features and Benefits: Non-corrosive valve seat. No additional expansion relief valve required. Cannot use MLP or SLP for outside applications. This is applicable to PB6.341 (15mm) & PB6.342 I.T.O outlet. Integral expansion relief valve. Stainless steel strainer. Copper to Copper inlet and outlet, 15mm & 22mm respectively. No special tools required to replace the cartridge. PPSU (polyphenylsulfone) valve seat. DZR brass die cast. Ø15mm Copper to Copper expansion outlet. System pressure: 600kPa. Maximum inlet pressure: 2500kPa. Spares: Replaceable cartridge C- PA6.862. Cap nut 64XS-22. Compression ring D-65XS-22. L/min 120 80 60 40 20 Flow Pressure MF3 15mm 600kPa MF3 22mm 600kPa 200 300 400 500 600 40 54 64 74 82 88 52 66 78 90 110 0 200 300 400 500 600 Flow Pressure MF3 15mm 600kPA MF3 22mm 600kPa SPARE CARTRIDGE 600KPA 600kPa Pressure control valve cartridge spare part. C-PA6.862 SANS198

PRESSURE CONTROL VALVES - BASIC INSTALLATION REQUIREMENTS CAUTION / WARNING: All installations of products and systems must be in accordance with the applicable SANS regulations, specifications and standards. Installations, servicing and maintenance should be done by accredited service providers only. A. Balanced Pressure Hot and Cold water pressure must be balanced (equal pressure) to all mixers, mixing points, showers and hand showers. This is achieved by taking the cold water supply from the downstream side of the pressure valve. B. Valve Identification kpa valve (Blue cap) 200kPa valve (Black cap) 400kPa valve (Red cap) 600kPa valve (Green cap) CAUTION: The pressure control valve must be compatible with the pressure rating of the hot water cylinder and the temperature and pressure relief valve (safety valve) C. Expansion Relief Drain Pipe Be piped in such a manner to drain downwards Not be interconnected with the safety valve (T&P) drain pipe Not to discharge in the hot water cylinder drip tray Discharge where flow is visible Be protected against frost Have minimal bends/ fittings D. General Requirements All pipes must be flushed clean before putting the system into operation. Waterflow must be in the direction of the arrow marked on the valve body. The valve must be easily accessible for maintenance/ servicing. The relief drain connection must allow for the relief drain pipe to be pulled to one side when removing the cartridge. Allow a minimum distance of ±mm for cartridge removal. Do not install a stop-cock or non-return valve between the hot water cylinder and the pressure control valve. Do not install a stop-cock between the hot water cylinder and the vacuum breakers on the hot and cold sides. Supply pipes adequately sized. Please ensure to make use of copper tube with the installation. Max inlet pressure 2,500kPa. System pressure according to the rating of the hot water cylinder, i.e. only use a 400kPa PCV with a 400kPa rated hot water cylinder and a 600kPa PCV with a 600kPa rated hot water cylinder.

PRESSURE CONTROL VALVES - BASIC INSTALLATION REQUIREMENTS E. Valve Valve is pre-set by the factory and does not require any additional adjustments and settings Integral expansion relief valve Integral stainless steel strainer Non-corrosive valve seat F. Connection Types Please take note that PCV ranges consist of a variety of connection types and sizes: 15mm Copper to Copper 22mm Copper to Copper 3/4"BSP Female connection end INSTALLATION OF VALVE AT THE INLET OF THE HOUSE CLEANING AND MAINTENANCE Q. When to service? Insufficient flow rate Continuous drip through the expansion drain Flush the cartridge if any dirt or particles are stuck Replace the cartridge if required Tighten with your hands or a suitable plumbing tool - DO NOT OVERTIGHTEN THE CAP

PRESSURE CONTROLG VALVES - BASIC INSTALLATION REQUIREMENTS WARRANTY STATEMENT All Cobra products are backed by a guarantee against defective materials and workmanship during the manufacturing process. Our products are backed by a Service Department and, most importantly, a full range of replacement parts is available from plumber's merchants. The same commitment that goes into designing and manufacturing a quality product also goes into ensuring the quality of the service back-up at every stage of design and installation. THE WARRANTY WILL BE APPLICABLE FOR A PERIOD OF 2 YEARS AGAINST COBRA FACTORY FAULTS. FAULT FINDER AND PROBLEM SOLVING COMPLAINT POTENTIAL FAULT WHAT TO DO Excessive water flow at expansion drain (hot water) Unbalanced pressure Balanced pressure Excessive leak / continuous drip Geyser thermostat faulty; Foreign matter on valve seat; Valve seat damaged Clean cartridge / valve; Replace cartridge; Check for correct flow in direction of the arrow Water hammer during valve opening / closing Loose piping; Air-lock; System pressure drop; Excessive water velocity Secure piping; Ensure correct pipe sizing; Vibration in system Faulty cartridge; Pipe undersized; Faulty washer in taps/ mixers Replace cartridge; Ensure correct pipe sizing; Locate and replace washers

Tel: 0861 21 21 21 Email: marketing@cobrawatertech.co.za www.cobra.co.za