DC Inline Watt Meter. RENOGY 150A High Precision Watt Meter and Power Analyzer. 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

Similar documents
12 Volt 30 Amp Digital Solar Charge Controller

Solar Controller / Battery Charger User s Manual

Battery Power Inverters

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

"Watt's Up" & "Doc Wattson" Watt Meter and Power Analyzer User's Manual

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

User Manual for CH-PFC76810

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

User Manual HomeGrid 3000 Solar Generator

Table Of Contents

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

SOLAR POWER - THE NEW WAY TO RV!

3 WATT LED SPOTLIGHT Model No. SLM

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

TruPower-Portable-500W. Solar Starter kit

Tracer-1206RN / 1210RN / 1215RN. Maximum Power Point Tracking Solar Charge Controller INSTRUCTION MANUAL

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

4KVA/5KVA Parallel Installation Guide

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

13 Watt PORTABLE SOLAR POWER KIT

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

ATLAS DC. Model: CSFDC B1 CSFDC B1/CSFDC B2 CSFDC B1/CSFDC B2

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

2 Installation Explanation

INSTRUCTION MANUAL EPSOLAR. Tracer-2210RN / 2215RN. Maximum Power Point Tracking Solar Charge Controller

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

3000W Power Inverter

LITHIUM BALANCE CHARGER

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

COLOR TFT LCD MONITOR. User Manual

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Power your CPAP machine no matter where your world takes you!

=============================== WARNING

GSM Alarm System User Manual

Solar Home System Kit Quality Standards

How To Use A Cdm250 Digital Multimeter

T7560A,B,C Digital Wall Module

Height w/o Terminals (in)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OWNER S MANUAL AND WARRANTY INFORMATION

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Model 1756 Test Lead Kit

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

G670 Intermittent Pilot Ignition Controls

Home Solar Kit Owner s Manual. Model: HS

Charge Regulator SCR 12 Marine

QLINK User Manual Stereo Audio Transmitter

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Model 201 Wiegand Touchpad Reader Installation Guide

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

ADM1TE 5/30A DIN rail single phase two wire energy meter

INSTALLATION INSTRUCTIONS

High Power Receiver CR-W400U Operating Instructions

SX460. Generator Automatic Voltage Regulator Operation Manual

ELECTRIC BICYCLE OWNER S MANUAL

HM-W536 Install Guide

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

OCSM Series. High Resolution Digital Crane Scale. User Guide

Advanced Wind/Solar Hybrid Controller. Model: WWS10A-48 Version 1.0

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ELECTRIC BICYCLE OWNER S MANUAL

FPV MONITOR. User Manual

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

User s Manual Before using the inverter, you need to read and save the safety instructions.

CHARGING SYSTEMS INTERNATIONAL

How To Control A Battery Cell Phone With A Battery Power Control System

ACTIVITY 6: Series and Parallel Wiring

Ground Resistance Clamp On Tester

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

XIA-USB INSTALLATION INSTRUCTIONS

Solar Photovoltaic (PV) Systems

YSmart Technology Co.,Ltd

SOLAR BOOST 2000E 25AMP 12VDC MAXIMUM POWER POINT TRACKING PHOTOVOLTAIC CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL

MN1010 Evaluation Kit v3 User Guide

FIREDEX Conventional Fire Panels

Home Solar Kit Owner s Manual. Model: HS

TROUBLESHOOTING GUIDE

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

Thermistor Thermometer MODEL NO

aseries A13B Mini Bullet Camera User Manual

Changers Kalhuohfummi User Manual

BATTERY CHARGER OWNER S MANUAL

Height w/o Terminals (in)

i ChatterBox! Motorcycle Security

19 LED Tube Controller ORDERCODE 41003

EM6556 e-domotica Mini Switch

HP UPS R1500 Generation 3

Multi Media Cable Tester TM-901N/TM-902/TM-903

Transcription:

DC Inline Watt Meter RENOGY 150A High Precision Watt Meter and Power Analyzer 0 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

Important Safety Instructions Please save these instructions. This manual contains important safety, installation, and operating instructions for the meter. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information. WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task. CAUTION: Indicates a critical procedure for safe and proper operation of the controller NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller. General Safety Information Read all of the instructions and cautions in the manual before beginning the installation. There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the meter. Do NOT allow water to enter the controller. Make sure all connections going into and from the meter are tight. Battery Safety NEVER short a rechargeable battery or the meter connected to a rechargeable battery. It can supply high currents and cause fire explosions. Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Ensure wiring and connections are rated to handle the input/out current and are properly assembled for each application Carefully read battery manuals before operation. Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Recycle battery when it is replaced. 1

Table of Contents General Information... 3 Optional Component... 3 Identification of Parts... 4 Installation... 4 Operation... 5 Measurement Screen Glossary... 6 Functions... 7 System Status Troubleshooting... 8 Dimensions... 8 Limited Warranty for PV Modules... Error! Bookmark not defined. Limited Warranty for Accessories... Error! Bookmark not defined. 2

General Information The Renogy 150A high precision watt meter and power analyzer is specifically designed for monitoring solar performance. This easy to use meter can monitor eight electrical parameters that are essential to power safety and performance. They include: amps, volts, watts, amp-hours, watthours, peak amps, minimum volts (sag) and peak watts. With a 60 volt and 150A capacity, high contrast blue display screen, and auto set features, you will surely find many great uses for this watt meter and power analyzer. Key Features Backlit LCD display Extremely low power consumption, practically ineffective to model s performance Precise and accurate readings Lightweight with many installation possibilities. Bare wire ends to allow the user freedom for their own type of connections. Optional Component Auxiliary Power Connector Cable This cable allows the Renogy Watt Meter to connect to an optional power source, such as a battery pack or a power supply. It allows resetting of the meter s accumulated measurements and has 4 bare, tinned leads for universal application. The cable is not required, but very handy for many applications. NOTE: Although the cable is an accessory to our product, it is not required. Also, Renogy currently does not carry this accessory and users will need to find their own means on attaining this cable. 3

Identification of Parts 1 2 4 3 5 Key Parts 1. Source Side Connection 2. Load Side Connection 3. Negative Wire 4. Positive Wire 5. Auxiliary Battery Port (Optional Component) Installation 1. Connect the Positive (+) and Negative (-) leads of SOURCE to the battery or other device s terminals. 2. Connect the Positive (+) and Negative (-) leads of LOAD terminals to a device to complete the circuit. CAUTION: Make sure connections are secure and expose no wire that may short. NOTE: The user is responsible for attaching connectors that are rated to handle the expected voltage and current limitations. 4

Operation Once the circuit is complete, the watt meter will turn on, display the default screen, then cycle through the remaining displays. You can think of the Watt Meter as a set of jumper cables; essentially a direct connection between same colored SOURCE and LOAD wires. Both the SOURCE and LOAD leads are electrically hot when a battery is connected to wither side. Current flows from SOURCE to LOAD, assure that all connections are secure to prevent component damage. Example #1: Battery on SOURCE side, Motor Speed Controller (ESC) and motor on LOAD side, With the ESC on, the watt meter displays the current into the motor, voltage and power at the battery and the accumulation of Ah and Wh while the motor is running. Example #2: Solar Panel on SOURCE side and a battery pack on the LOAD side. The Watt meter demonstrates the charging current into the battery, the voltage and charging power at the battery, and the accumulation of the charge in Ah and Wh. 100.00A 10.00V Data Queue 100.0W 100.00A 10.00V Data Queue 100.0W Startup Screen Displays the peak and minimum measurements recorded followed by the Amp-Hours (Ah) and Watt- Hours (Wh) being reset to 0. Measurement Screen Displays Amps, Volts, and Watts. Screens are updated every 0.4 seconds and they are presented sequentially every 2 seconds in their appropriate units (Ah, Wh, Ap, Vm, Wp). 5

Measurement Screen Glossary Parameter Amps, A & Ap (Current) Description Only the current from SOURCE to LOAD is measured. The Amp value displayed is the average current over the last screen update interval Peak Amp value (Ap) display is the maximum current drawn from the LOAD side. Peaks lasting only a fraction of a second can be captured. Supplying the auxiliary power with a voltage greater than what the meter it is measuring removes the meter s operation current from measurements. To reduce heating, measure currents over 65 amps from reduced time and consider using connector which can handle large current. Volts, V & Vm (Voltage) Watt-Hours, Wh (Energy) The displayed value is the average voltage over the last screen update interval. The displayed minimum volts value (vm) is the Minimum voltage (or sag ) measured on the SOURCE side. The volts value is measured on the SOURCE side. The displayed value is the total energy delivered in watt-hours and it is measured on the LOAD side. For best results, do not interrupt the SOURCE connection to the watt meter during a charge measurement. Amp-Hours, Ah (Charge) The displayed value is the total charge in Amp-hours(x1000=mAh) delivered since the startup screen and it is measured on the LOAD side. For accurate results, do not interrupt the SOURCE connection to the watt meter during a charge measurement. Watts, W & Wp (Power) The displayed value is the average power delivered in watts (=Volts x Amps) over the last screen update interval. The displayed peak watts value (Wp) is the maximum power drawn on the LOAD side since the startup screen ended. Watts are measured on the LOAD side 6

Functions The Renogy Power Analyzer measures parameters key to electric power safety and performance. Use it to: Prevent Peak Current from damaging battery Motor control Wiring and connectors Verify sufficient operation voltage under load Set cut off voltage Check battery capacity and health Balance battery cells Confirm proper battery charger operation 7

System Status Troubleshooting Meter not turning on Make sure the connections are properly secured onto the LOAD and SOURCE side of the meter. If so, disconnect all connections and connect again to resume proper operation. Technical Specifications Description Operation Voltage: Auxiliary Battery Operating Voltage Measurement Resolution: LCD Display Dimensions: Weight Wire Size Parameter 7-55V 0 55 V 0 150A, 0.01 A Resolution 0 60 V, 0.01 V Resolution 0 9000 W, 0.1 W Resolution 0 65 Ah, 0.001 Ah Resolution 0 9000 Wh, 0.1 Wh Resolution 62 x 12.5 mm (2.44 x 0.49 in) 85 x 45 x 25 mm (3.35x1.77x0.98 in) 82 g (0.18lbs) 12 AWG Dimensions NOTE: Dimensions are in inches. Updated: July 10, 2015 8

9