MagnumStone. Retaining Wall. masonry. style and function

Similar documents
Connex. Mortarless Masonry Block System

LAYING BLOCK AND BRICK

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Laying the First Course. 1. Excavate the site and construct the footing.

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Understanding BS EN 771-3: Aggregate concrete masonry units

Natural Thin Stone Veneer

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

What you need to know about concrete block basement construction.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY

0331 Brick and block construction

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Hanson Building Products. precast basement solutions

Lay blocks with mortar

Guide for SOLID CONCRETE BLOCK SEALS

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

3 Masonry and Manufactured Stone (Interior and Exterior)

Technical Advice Note

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

Confort 26. Sliding Systems. Sapa Building System

How to build raised beds page

Saferand easierinstallation

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

The Verdura Wall check with your local building department

PERFORMANCE GUIDELINES

R E S I D E N T I A L H O U S I N G

AB Courtyard Collection

COMMONLY USED RESIDENTIAL BUILDING CODES

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

GRC Porticos. Lightweight entrance porticos ABBEY ARTSTONE

v2 AB Classic 2 AB Jumbo Junior 6 AB Lite Stone v6 AB Classic 4 AB Jumbo Junior 8 AB Lite Stone 10 AB Classic 10 AB Jumbo Junior

12.1 Schlüter -KERDI-BOARD

Chapter 3 Pre-Installation, Foundations and Piers

Plaisance 24. Sliding Systems. Sapa Building System

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Free-Form Concrete Pool

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

International Greenhouse Company

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Installation & Technical Guide

How To Build A Wall System

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

EAST LYME HIGH SCHOOL

Design Ideas by Allan Block

MeltonStone Cast Stone Product Specifications

How to build a Pizza Oven in 4 days

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

Belt Conveyor System

The minimum reinforcement for the stem wall is the placement of:

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

CHAPTER 8- REDUCING THE MOISTURE

Division 4 Section Concrete Masonry Specifications

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

2015 PRICE L IST INNOVATION THROUGH ENGINEERING S A L E A N C H O R C O N C R E T E.

glass & Glazing Products

Basement Moisture Problems

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

BMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

IMPORTANT INFORMATION

Ceramic Glazed Brick Exterior Walls

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

Construction Specification for Concrete Curb and Concrete Curb and Gutter

Manufacturing Quality Concrete Products

Residential Inspection Guidelines

Chapter 2 Basis of design and materials

2.9 WINDOW & DOOR BUCKS

Architectural Concrete Masonry

LANDSCAPING AQUA SPORT. Rainwater treatment using filter substrate channel. DIBt approval applied for

Masonry Blueprint. * Considered essential competencies ** Should be mastered at the journeyman level All other items are considered supplemental

E-82. Access Roads and Crane Platforms. 77m steel tower. 1 of 12. Specification Access Roads and Crane Platforms E-82/ 77m steel tower.

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

How To Retaining Wall Guide

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Energy Company Obligation (ECO): Technical Monitoring Questions

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

WATERPROOFING OF WET ROOMS

PRODUCT GUIDE lower tolerances high quality

Concrete Waterproofing Systems. Integral Protection.

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No December 2014

AUSTRALIAN PAVING CENTRE

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Code of Standard Practice for Timber Frame Structures

Catch Basin Rehabilitation Road Commission for Oakland County, Michigan

DE Frame with C Series Sidelight

Transcription:

MagnumStone Retaining Wall masonry. style and function

Green Plantable Wall Fence Posts Outside Corner 2 Austral Masonry

The Design Advantage The MagnumStone retaining wall system was developed with the engineer, designer and installer in mind. MagnumStone s durable, high strength concrete SecureLugs fit into the lower unit s hollow core, allowing significant lateral movement without losing the unit interlock. The wet-cast manufacturing process provides the units with high strength, low absorption and great freeze/thaw results. Tapered sides make it easy to build tight curves and straight walls with complete accuracy. The MagnumStone s vertical and horizontal hollow core, filled with clear crushed gravel, provides added weight, an excellent wall drainage system and a superb connection with the geosynthetic reinforcements. Inside Corner Outside Curve Inside Curve Austral Masonry 3

Gravity Wall Geogrid Wall Positive Connection 4 Austral Masonry

The Installation Advantage The hollow core design reduces the unit weight, making it easy to handle for any small or large type of machinery. The patented SecureLug, tapered sides, 0.74 square metre face and light weight MagnumStone system out performs the old traditional wall methods, speeding up installation time and reducing costs considerably. A MagnumStone installation crew can construct 80 to 150 square metres of wall units per day, making this one of the quickest and easiest wall systems to build. The unique hollow core design makes the MagnumStone system easy to assemble and disassemble when building temporary wall projects. The flexibility and ease of installation provides the end user with many options to solving nearly any wall problem. Steel/Concrete Wall Soil Anchoring Wall Step Up Austral Masonry 5

Standard Base Unit Standard Unit Standard Top Unit Half High BaseUnit 6 Austral Masonry

The Economic Advantage MagnumStone units can be loaded and unloaded two at a time, quickly and easily. This means fewer trucks to manage, reduced labor and a reduction in fuel consumption compared to typical solid systems. Fewer trucks on the road and project site will reduce the potential for project delays. Horizontal Hollow Core SecureLug Connection Vertical Hollow Core Standard Unit specifications Dimensions 1219mm W x 609mm H x 609mm D Face Area 0.745 m2 Volume of Voids 0.180 m3 Unit Weight 621 kgs Gravel Filled Weight 975 kgs Batter/Setback 4.5 5 cm/unit & vertical option available. Half Height Standard Unit Half Height Top Unit Corner/End Unit Austral Masrony 7

Austral Masonry Head Office New South Wales 44 Clunies Ross Street Prospect NSW 2148 PO BOX 6137 Seven Hills NSW 2147 Tel. +61 2 9840 2333 Fax. +61 2 9840 2344 Email. sales@australmasonry.com.au Trading hours For trading hours please visit www.australmasonry.com.au Architec TM Designer Masonry Additional Information Block Laying Masonry walls are to be constructed in accordance with AS3700:2011. Stock Colours and Textures Lead times apply to all coloured blocks. Longer lead times apply to Honed, Polished and Shot-Blast finishes as the product must be cured for four weeks to harden sufficiently before processing. Austral Masonry recommends part size blocks are cut/bolstered on site to maintain colour consistency. Textures Finishes including Honing, Polishing and Shot-Blasting are produced on a made to order basis. Lead times apply as the product must be cured for four weeks to harden sufficiently before processing. Contact your nearest Austal Masonry office for approximate lead times and premiums on special textured finishes. Architec is available standard with one face. Additional faces can be made to order on honed, polished, and shot blast finishes. A surcharge may apply. Not all finishes are available in all regions. Colour and Texture Variations The colours shown in this brochure are provided as an indication of the colours and textures available. Some variations in colour may occur due to changes in raw materials. In addition variation can occur between production batches. Construction Notes 1. Blocks must be kept dry on site before use and when laid. Freshly laid walls must be covered overnight and when rain interrupts work in order to prevent moisture entering the cores of the blocks. 2. Do not put mortar on the web of the blocks. 3. Ensure that perpends are buttered on each side with a void in the middle. The mortar joints should be well ironed to provide a tight sealed joint. 4. Ensure mortar smears are removed before mortar sets as acid cleaning later can discolour the masonry can discolour and damage the masonry. 5. It is important that retaining walls have good drainage behind the wall and waterproofed. 6. For non-grouted masonry, a horizontal weep hole at the floor joint of each core should be provided to drain water that may be trapped inside the blocks. Partially fill the bottom course blocks with 20mm blue metal or similar drainage material to prevent mortar droppings from blocking the weep holes. Brochure Colours The printed colours in this brochure are only a guide. Please ask to see a sample of your chosen colour/texture before specifying or ordering. 1300 MASONRY (1300 627 667) www.australmasonry.com.au proud supporters The range of building products from The product images shown in this brochure give a general indication of product colour for your preliminary selection. Austral Masonry recommends all customers see actual product samples at a selection centre prior to making final selections.