Sensor- Operated, Deck-Mount Foam Soap Dispenser

Similar documents
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Bathroom Installation Guide

MAC FAUCETS. Owner s Manual. Models: FA444

Installation Instructions S

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Installation Instructions

SLIDING PATIO DOOR INSTALLATION INSTRUCTIONS USING FRAME SCREWS

Installation Instructions

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Triac Printed Circuit Board Replacement

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions

How To Replace A Reverse Osmosis Water Tank

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

SENSOR FAUCETS. OPTIMA ETF-80 Faucet. P a r t s G u i d e 24 VAC HARDWIRE FAUCETS SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL 60131

Installation Instructions

Line to Refrigerator Ice/Water Dispenser

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

123 Industrial Loop Road Paynesville, MN Phone:

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Awning Instructions. Full Cassette 1.5m to 6m

Installation Instructions

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Bottom Loading Water Dispenser

Cooktop Low-Profile Ventilation Hoods

Installation Instructions

Installation Instructions

Guidelines for Earthquake Bracing of Residential Water Heaters

123 Industrial Loop Road Paynesville, MN Phone:

Installation Instructions for Water Methanol Stage 1

Awning Instructions. Standard Manual 1.5m to 4.5m

Determine the desired location fixture and center the coaxial cord location to the electrical box.

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

INSTRUCTIONS: LocknCharge Laptop Carts

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

KITCHEN INSTALLATION GUIDE

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Samuel Shorty Bunk Bed

INSTALLATION INSTRUCTIONS BL-8704

Installation Instructions

INSTALLATION AND SERVICE MANUAL

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Saferand easierinstallation

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Easy as instructions on how to install or replace the Cleanviro waterless urinal tablet

Watts Pure Water Systems

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

AMERBRITE UNDERWATER WHITE LED POOL LAMP

INSTALLATION INSTRUCTIONS

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

INSTALLATION INSTRUCTIONS MK-8704

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

XL PREMIUM OIL COOLER KIT

Nexus FS Point of Use Installation Guide

Installation Instructions

FRONT WINDSHIELD SEAL INSTALLATION

Instruction Manual. AWK-115S

SEQUEL ASSEMBLY INSTRUCTIONS Compact Desk

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1

Installation Instructions

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

PORTABLE AIR CONDITIONER

DIY CABINET REFACING INSTALLATION GUIDE

Seismic Installation for Attic Storage System

Guidelines for Earthquake Bracing Residential Water Heaters

Important Information

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

GenStore Archive Cabinet

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

CULINAIRE COLLECTION STAINLESS STEEL KITCHEN SINKS

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Wetroom Panel (Concealed Fix)

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

LIEBERT VNSA Installation Sheet

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Operation Manual FOR & 14030

Installation Instructions

REPAIR AND MAINTENANCE MANUAL

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Portable Air Conditioner

Rules for Safe Operation

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Care and Handling of Your VAIO Computer

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

IMPORTANT SAFETY RULES TO FOLLOW

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

OWNER S MANUAL Table Tennis Table Patent Pending

Transcription:

Sensor- Operated, Deck-Mount Foam Soap Dispenser Installation & Operating Instruction Manual Thoroughly read this instruction booklet before installing or operating the Sloan. Keep the Installation & Operating Instruction Manual with other product information for future reference. Sensor-Operated Dispenser SJS-1750 Sensor-Operated, Deck-Mount Foam Soap Dispenser Specifications Width 1.65 (42 mm) Height 4 (102 mm) Depth 4.25 (107mm) Dispenser Rate Approximately 1.2 ml per use Capacity 1000 ml bottle Specifications are subject to change without notice. Table of Contents Page Parts/Dimensions 2 Installation Instructions 3-5 Operation 6 Maintenance/Replacements 6-7 Emergency Measures 8 Consumables 8

OVERVIEW OF PARTS AND DIMENSIONS Note: Deck mount foam soap shown mounted with faucet for reference. Foam soap Foam soap Liquid soap and air tubes Foam tank case unit Power cord Wiring 2

INSTALLATION Check that all parts are included in original packaging for proper installation. Package contents: Foam soap (1) Dispenser shank nut, washer and packing Connector case, stainless steel panhead screws (2) and adhesive pad (1) Tubing (1) Foam tank case unit (1) Screw kit (4-screw kit x 1) Foam tank case key (2) Tube clamp (2) Wire clip (2) Tools needed: Drill 1/8 drill bit 1/4 masonry bit (if attaching to concrete wall) 1 hole drill for drilling through countertop Adjustable wrench or basin wrench Phillips head and slotted screwdrivers Utility knife Hammer Ruler/tape measure Precautions Before using the, thoroughly read the Precautions attached to the liquid products. Immediately clean any spill on the floor to help avoid falling, injuries or other hazards. Choosing Installation Placement For indoor use only. Do not install in areas with high humidity or where the unit may be exposed to direct sunlight. Install the unit on a sturdy horizontal surface that is in ambient temperature (0-35 C). Make sure foam tank case unit will be accessable from the underside of sink. Prior to Installation An electrical outlet is needed for operation. It should be protected from any contact with water and be within the range of the power cord (approx. 70 ). If no outlet is available, consult licensed electrician. Locate final position of foam soap and drill 1 hole in counter top. STEP 1. Remove unnecessary components Remove unnecessary components from washbowl or horizontal surface that are mounted on the area where the foam soap will be installed. STEP 2. Install foam soap Insert the foam soap shank into the mounting hole. Secure the foam soap to the countertop using shank packing, washer and nut. 1 hole in counter top Shank Packing Washer Nut Foam soap 3

INSTALLATION STEP 3. Install foam tank case unit to wall Before installing on the wall, check that no other piping and wiring is running behind hole locations. Wall should be sufficiently reinforced or risk failure due to foam tank case unit falling. Determine a temporary position for mounting the foam tank case unit. Make sure unit is within reach of the liquid soap and air tube from the foam soap. Use the mounting bracket as a guide, mark where holes need to be drilled. Important: Make sure bracket and foam tank case unit is mounted level. When installing onto a concrete wall, drill holes 1.125 deep using a 1/4 masonry drill bit. Insert wall anchors into the holes and mount the using screws. When installing onto a wood wall, drill holes using a 1/8 drill bit and attach the using screws. 220 200 Foam soap tube from foam soap Foam soap tube fitting Foam tank case unit Air tube from foam soap Tube clamps Air tube fitting Fittings connection label Removing tubes When removing a tube from a fitting, remove the clamp first and then pull out the tube from the fitting. To reconnect a removed tube to a fitting, retrim tip of the tube at right angle prior to connecting. STEP 4. 58 116 Connect foam soap tube and air tube Connect the foam soap tube and air tube from the foam soap into the soap tube fitting and air tube fitting found on top of the foam tank case unit, respectively. Check soap tube tags and align with correct fittings as indicated on the fittings connection label. Cut the soap tube and the air tube at suitable lengths. Ends should be cut at right angles and tubes should be free of kinks and bends when connected. Insert soap tube and air tube into respective fittings and secure with tube clamps. 4

Connect wiring Connect the relay harness, which comes from the bottom of the foam tank base case unit, with the hand sensor harness, which comes from the foam soap. From foam soap Hand sensor harness Connector case Connectors Relay harness From foam tank case unit Protect wire connections Feed the connectors of the relay harness and hand sensor harness into the connector case as shown in illustration. After positioning all wiring, fold the connector case in half and close using two stainless steel panhead screws. Be careful not to pinch the wiring in the connector case. Mount connector case Completely clean the area where affixing the connector case. Remove liner and affix one side of the adhesive pad to the back of the connector case. Remove the adhesive liner on the pad affixed on the connector case and attach to the underside or back of basin or sink. When mounting the connector case, screws must be accessable in case wiring needs accessing. Harness openings must face down to keep water from entering case. Stainless steel panhead screws Attach wire guide clips Attach wire guide clips to the bracket and secure wires. Adhesive mounting pad Connectors Hand sensor harness Relay harness Harness openings Plug in to electrical outlet Wire guide clips 5

OPERATION Operation Mount soap bottle to the foam tank case unit. Press the reset switch, which begins the pumping cycle to purge air from the tube. This step may be required twice to completely prime the unit. Operation switch Joint cap Reset switch Liquid soap bottle Operation light Operation panel Foam tank case unit Joint cap MAINTENANCE Replacing Soap The foam soap indicator light on the foam soap blinks and stops dispensing when the soap bottle in the foam tank case unit runs out. Change the soap bottle. Turn the key to open the foam tank case unit cabinet door. Remove the joint cap and dip tube and discard empty soap bottle. Joint cap Insert the dip tube and attach the joint cap to the new bottle and install the bottle in the tank cabinet. Be sure to attach the joint cap securely. Close the door and lock using key. Cleaning For reliable long-term use, perform regular maintenance for the unit. Be sure to turn off the operation switch and check that the operation light is off when maintenance is done. Remove soil with a soft, dry cloth. If the unit is seriously polluted on portions other than the hand sensor, use wet cloths properly diluted neutral detergent. Then remove the detergent with a soft damp cloth and then rub with a soft, dry cloth. Place hands under foam soap. The sensor will detect the presence (approximately 0.6 seconds) and dispense foam soap from the foam soap. Check for leaks from the bottle or dispensing unit. Soap should only be dispensed through the outlet spout. NOTE: This procedure must be completed every time a bottle is replaced. 6

Cleaning the hand sensor Clean the hand sensor periodically (about once a month) according to the following procedure: Press the operation switch to OFF (the operation light goes off ). Gently wipe the hand sensor area with a cloth moistened with warm water. Press the operation switch to ON (the operation light goes on). Make sure that the nozzles properly dispenses foam soap. NOTE: Do not leave water drops on the hand sensor area. Remaining water drops may cause a malfunction. Cleaning foam soap If the tip of the soap nozzle is clogged, the dispensing capability may fail or function partially. Clean the nozzle according to the following procedure: Press the operation switch to OFF (the operation light goes off ). Remove the foam soap dispensing Mesh nozzle and then the internal mesh. Nozzle Wash it with lukewarm water. Turn ON the operation switch (the operation light goes on). Check the foam soap spraying state. Repeat as needed. Before Calling for Repair Problem Unit does not operate. Soap does not dispense. Liquid soap is not in foam state. Action Check operation switch is on. Check power plug is securely inserted to the outlet. Soap bottle needs replacing. Check soap dispensing nozzle for clog. Clean hand sensor. Check mesh is mounted in the foam-dispensing nozzle. 7

EMERGENCY MEASURES Take action according to the chemical being used as listed on the container. See the Material Safety Data Sheets. Eye Contact: Flush eyes with water for a minimum of 15 minutes and consult a physician immediately. Ingestion: Drink water to induce vomiting and consult a physician immediately. Inhalation: Get fresh air immediately. If condition does not improve, consult a physician immediately. CONSUMABLES Product No. Description Order No. SJS-1751 Sensor Deck-Mount Foam Soap 0700751 SJS-1751-1 Sensor Deck-Mount Foam Soap with Moisturizers 0700752 SJS-1751-2 Sensor Deck-Mount Antimicrobial Foam Soap 0700753 SJS-1751-3 Sensor Deck-Mount Foam Soap Green Seal (Fragrance Free) 0700754 SJS-1751-4 Sensor Deck-Mount Foam Soap Green Seal (Rose) 0700755 The information contained in this document is subject to change without notice. Air Delights, Inc. 9974 SW Arctic Dr. Beaverton, Or. 97005 Phone: 800-440-5556 Fax:503-643-8224 www.airdelights.com 2008 Sloan Valve Company Printed in the U.S.A. JSD6061.2 02/08