660 nw, 10 mw, 60 degree fan angle, Class II CDRH, 0.5 m cable with flying leads

Similar documents
INTMOD485-LH Protocol Converter

WORLD-BEAM QS30 Sensors

MULTI-BEAM LS10 Light Screen System

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Cross-beam scanning system to detect slim objects. 100 mm in

Machine Safety Switch: SI-LM40 Series Limit Switch Style

LED...A Q Series Sealed High-Intensity

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

IR Receiver Module for Light Barrier Systems

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Ultrasonic Distance Meter. Operation Manual

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

Architect/Contractor Information Package

Advantium 2 Plus Alarm

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Laserlyte-Flex Alignment System

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Adjustment functions for both span and shift have been incorporated

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Dual Laser InfraRed (IR) Thermometer

BroadBand PowerShield. User Manual

ITEM MODEL QTY. Filter ITEM MODEL QTY USB-RS485 Converter (with 3716A-21) 3716A-20 1

PERF10 Rubidium Atomic Clock

NLC 800 Air-Cooled Argon-ion Laser

Dual Laser InfraRed (IR) Thermometer with Color Alert

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Original instructions Tina 3A/Aps Adaptor unit

Infrared Viewers. Manual

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Operating Manual UWAPS-TINY Series

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Single Port T1/E1 Tap

IR Sensor Module for Reflective Sensor, Light Barrier, and Fast Proximity Applications

OBIS Galaxy. Fiber Input, Fiber Output, Eight Channel Beam Combiner. Superior Reliability & Performance. OBIS Galaxy Features:

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

i410/i1010 AC/DC Current Clamp

MDC Series

3M Wrist Strap and Footwear Tester 740. User s Guide

Infrarot-Bewegungsmelder IP44

Reflective Optical Sensor with Transistor Output

Silicon PIN Photodiode

About this Manual. Support for Your Product

DSM155 Digital LED Light Meter User s Manual DSM155

Guideline Laser Series

Ceiling Mount Air Handler Manual

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Modular I/O System Analog and Digital Interface Modules

Series 510 Submersible Level Transmitters

FLEX by 3M Light Module System

Tina 2A/B Adaptor unit

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

Silicon PIN Photodiode

HIH-4000 Series Humidity Sensors

Optocoupler, Phototransistor Output, AC Input

Ambient Light Sensor

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Operating instructions Optical distance sensor O1D100 O1D / / 2012

, User s Manual

Optical Power Meter. Specification & User Manual

Day / Night IR Color Camera User Manual V2.1.0

Model SRMD Setra Remote Monitoring Display

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

M18-4 Stainless Steel 18 mm Barrel Sensors

User Manual (English)

Amplified High Speed Fiber Photodetectors

CQM1-SF200/CS1W-SF200

2-Way Wireless Indoor Siren Installation Guide

Dual Laser InfraRed (IR) Thermometer

16/32 Channel 1U Rack Mount CCTV Power Supply

Reflective Optical Sensor with Transistor Output

How To Use The Visifault Visual Fault Locator

RGC-IR Remote Gas Calibrator for IR400

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

FIRERAY 2000 Installation Guide

Tube Liquid Sensor OPB350 / OCB350 Series

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

W150: Miniature photoelectric switch series with completely integrated electronics

Description. Dimensions. Features. precision works better

TTL to RS232 Adapter User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ST Series POWER SUPPLIES USER INSTRUCTIONS

LED Security Spotlight User Manual

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

User and Installation Guide

Silicon NPN Phototransistor

MCA Series Multi-Channel Amplifiers. Operation Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

USER MANUAL. Kramer Electronics, Ltd. Models:

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

AC and Pulse Film Foil Capacitors KP Radial Potted Type

Optocoupler, Phototransistor Output, with Base Connection

Transcription:

Datasheet Laser line uniformity up to 95% on 100% of the line External user focus mechanism Photo feedback for optimal power stability up to 500 khz Dynamic line balancing for repeatable performance Robust thermal management, providing better stability and longer lifetime Remote laser monitoring and control via RS-232 communication Precision refractive optics Model LLG660P10A60II Description Laser Line Generator 660 nw, 10 mw, 60 degree fan angle, Class II CDRH, 0.5 m cable with flying leads The length of generated line is a function of the laser fan angle and the working distance of the object. The fan angle of the laser is 60, making the length of the generated laser line is equal to the working distance. Specifications Wavelength 660 nm Center wavelength at 25 C Output Power 10 mw max. Operating Voltage 5 to 24V dc Operating Current 185 ma max. at 25 C Power Consumption 3 W max. Long-Term Power Stability (8 hrs ± 3 C) < 5 % ESD Protection Level 4 Straightness (%) > 25 mm Line 0.1% Ambient Temperature Operating Conditions: 10 C to +50 C (+14 F to +122 F) Non-Operating Conditions: 20 C to +60 C ( 4 F to +140 F) Shock Tolerance (g) (6ms) 30 Wavelength tolerance +7 nm/ 10 nm Input Impedance 1.5 kω Beam Angle < 3 mrad Fan Angles 60 at 80% clip Pointing Stability Over Temperature < 10 µrad/ C RMS Noise (20 Hz to 20 MHz) < 0.5 % Peak to Peak Noise (20 Hz to 20 MHz) < 1% Warm-Up Time < 5 minutes from cold start Mechanical Specifications Weight: < 70 g Length: 95 mm standard configuration; 98 mm accessory configuration Diameter: 19.05 mm Material : Black annodized AL 606 1 T 1 Connection 0.5 m (1.6 ft) cable with flying leads Certification P/N 171923 Rev. B 24 January 2014 0 171923 2

Dimensions EXTERNAL FOCUS ADJUSTMENT LOCKING SET SCREW (NO.2-56) TOP VIEW 3.7in 95.1mm.5in 13.8mm 1.4in 36.3mm CLAMPING AREA 1.1in 27.2mm 1.6ft [0.5m].73in 18.64mm FRONT VIEW BEAM EXIT.7in 16.9mm EXTERNAL FOCUS ADJUSTMENT.75in 19.05mm CLAMPING AREA INDICATOR LIGHT REAR VIEW SIDE VIEW Hookup Wire Color Assignment FAULT Power Supply <_30V Black Blue V ground V mod GND I LOAD <_100 ma Red/Black White V mod ground RS 232 Recv White/Black RS 232 ground Orange RS 232 Trans Fault output is an open collector of the transistor that allows wire junction OR functionality with fault signals from other devices. The output can tolerate voltage up to 30V and can drain the current up to 100 ma. The circuit is protected from over current by recoverable fuse. Red Green V in Fault Definitions Uniformity Max relative intensity variation over 100% of the time U = (I max - I min ) (I max + I min ) Contained Power Power contained in the 100% line at the 80% Clip versus the power contained in the 13.5% Clip Line Length / Fan Angle Relative Illumination Floor Straightness CP = 80%P 13.5%P Fan angle is the angle of the projection taken at the 80% Clip Line length is the physical length at a given working distance taken at the 80% Clip This is the minimum relative intensity at any point on the define line length Measured as a % of the normalized intensity Deviation from best fit line Δ = Δ 1 + Δ 2 S = (Δ/L)*100 2 www.bannerengineering.com - tel: 763-544-3164 P/N 171923 Rev. B

Flat-Top Intensity Profile 1.00 0.80 0.60 0.40 100% of the line is defined at the 80% Clip Profile will not drop below 75% Relative Intensity 100% of Line length for uniformity and straightness Fan Angle / Line Length Normalized Intensity 0.20 CP = Ratio of Areas defined by Fan Angle 0.00 and 13.5% width Position (mm) Accessories FLTMR-660 Red filter kit, 13.5 mm diameter, 1 mm thick, for ivu sensors FLTR-660 Red filter kit, 13.5 mm diameter, 1 mm thick, for C-mount lenses Brackets SMBLLG R 11.94 mm [0.47 ] R 9.625 mm [0.38 ] 8.1 mm [0.32 ] 42.7 mm [1.68 ] SMBLLGS Mounting bracket with heat sink 14.36 mm [0.57 ] 50.8 mm 15.49 mm [2 ] [0.61 ] 31.5 mm [1.24 ] 47 mm [1.85 ] 37.5 mm [1.48 ] 14.6 mm 3.8 mm [0.58 ] 1/8 dia (2) [0.15 ] 4.3 mm [0.17 ] Swivel mounting bracket 0.750 1.500 0.750 0.969 1.625 O 0.750 30 0.500 27.5 mm [1.09 ] 15.5 mm [0.61 ] TAP1/4-20 UNC,3 HOLES 6 mm [0.24 ] 21.5 mm [0.85 ] 30.6 mm [1.2 ] M3 X 0.5 THD INT (4) 30 1.000 P/N 171923 Rev. B www.bannerengineering.com - tel: 763-544-3164 3

Power Supply Figure 1. PSLLG12V 12V Terminal Block Power Supply Cautions and Warnings Do not point the laser toward an eye. Wear appropriate laser safety goggles at all times when the laser is operational. The laser light emitted by this laser may be in the infrared area of the electromagnetic spectrum and may not be visible to the human eye. Use extreme caution at all times when using the laser. The output power of this laser is high enough to cause permanent damage to the human eye. Wear appropriate laser safety goggles at all times when the laser is operational. Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. These structured light devices meet CDRH Class II and IIIa only as complete assemblies. Removal of the optical head (image generating optics) for cleaning could expose personnel to hazardous laser radiation (sometimes equivalent to a Class IIIb/3B laser) and will void the product safety classification. Turn the laser off whenever the optical head is removed, unless alignment is being performed. Use extreme caution when performing these servicing operations and wear appropriate eyewear at all times. Servicing operations must be performed by personnel trained to manipulate Class III/3B lasers. Never look directly at a raw laser beam. Banner will not be held liable for any injuries caused by product misuse. Do not place any flammable objects directly in from of the free, non-extended beam (without the line generating optics), especially with higher power beams. Use caution around all laser products. Lasers are highly concentrated light sources, some invisible to the eye. Never point a laser beam into your or any other person's eyes; permanent damage to the retina can occur! 4 www.bannerengineering.com - tel: 763-544-3164 P/N 171923 Rev. B

Use extreme caution at all times when the laser is in use. Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. www.bannerengineering.com - tel: 763-544-3164