Safety in electromagnetic fields. EMF Directive 2013/35/EU

Similar documents
Measuring static magnetic fields

Measuring electric and magnetic fields

REGULATORY IMPACT ANALYSIS (RIA) SAFETY, HEALTH AND WELFARE AT WORK. (Electromagnetic Fields) REGULATIONS (S.I. No. of 2016) 5 th January 2015

Continuous, remote monitoring and logging of electromagnetic fields

Continuous, remote monitoring and logging of electromagnetic fields

AN OVERVIEW OF STANDARDS AND REGULATION CONCERNING EXPOSURE TO RADIOFREQUENCY FIELDS

COUNCIL RECOMMENDATION of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC)

Official Journal of the European Communities. (Acts whose publication is not obligatory) COUNCIL

Frequency selective monitoring and logging of environmental electromagnetic fields

Human Exposure Limits

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

Electromagnetic Fields

Numerical Modelling of E-M Occupational Exposures associated with MRI

Dual Chamber Temporary External Pacemaker

Radio waves and health. Mobile communications

sources in our environment i.e. Natural and man-made. The sun, earth and ionosphere are the natural source.

Operating Frequency Selection for Loosely Coupled Wireless Power Transfer Systems with Respect to RF Emissions and RF Exposure Requirements

Selective and broadband low frequency field analysis

EMR Exposure Limits & Assessment Methods for Mobile Phone Communications. Lindsay Martin Manager, Non-Ionising Radiation Section

IEC TC106. Standards for the Assessment of Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 to 300 GHz

Measurements of radiofrequency fields from a WEL Networks Smart Meter

The Existing Public Exposure Standards Cindy Sage, MA Sage Associates, USA

RF safety at base station sites

Statement of the Chief Medical Health Officer

Nardalert S3 Non-Ionizing Radiation Monitor

REVIEW OF EXPOSURE LIMITS AND HEALTH CONCERNS SANTA ANA. Base Station Telecommunication Transmitters UNIFIED SCHOOL DISTRICT

Millennium Product Inc. Model: Cell Shield / Zorb

ELECTROMAGNETIC FIELDS AND PUBLIC HEALTH HEALTH AND SAFETY GUIDELINES #1

Dr MH Repacholi Co-ordinator. ordinator,, Radiation and Environmental Health World Health Organization, Geneva, Switzerland

Wireless Broadband: Health & Safety Information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

THE ANSI/IEEE RF SAFETY STANDARD AND ITS RATIONALE. Om P. Gandhi and Gianluca Lazzi Department of Electrical Engineering Salt Lake City, Utah 84112


Regulatory Compliance Services and Products

A Survey of Radiation Levels Associated with Mobile and Wireless Communication Technology Masts in Public Areas in Kaduna Metropolis

Human exposure to RF

Electromagnetic Field Safety

EFFECTS OF ELECTROMAGNETIC FIELDS ON ORGANISMS AND PROTECTION PRINCIPLES

30 In Compliance October

Mobile use, radio signals and health

STANDARDISATION MANDATE ADDRESSED TO CEN, CENELEC AND ETSI IN THE FIELD OF ELECTROTECHNOLOGY, INFORMATION TECHNOLOGY AND TELECOMMUNICATIONS

Measurement of Output Power Density from Mobile Phone as a Function of Input Sound Frequency

Risk of Brain Tumors From Wireless Phone Use. Journal of Computer Assisted Tomography November/December 2010; Vol. 34, No. 6; pp.

The field strength measurement and SAR experience related to human exposure in 110 MHz to 40 GHz

SERVICES BROCHURE info@t-r-s.com.au PO BOX 680, Claremont, 6910, Western Australia

IEC and CISPR Standards

ARIB TR-T V Specific Absorption Rate (SAR) requirements and regulations in different regions

$ $; #! $ $ $ $. $ $, $ $,! $ # $ -$.! #,! # #. ' () «-,» ( ),. 2-3!!!, - $# (RF) #! $., - #! $ $, #. - & # $!.

BLM Emerging Risks Team - Report on Mobile Phones/EMFs

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

English version. Central Secretariat: rue de Stassart 35, B Brussels

Scaling Public Concerns of Electromagnetic Fields Produced by Solar Photovoltaic Arrays

Experience with taximeters with a look at the corresponding tables

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

727 VHF/UHF/SHF Spectrum Monitoring System

What the experts say: The consensus of scientific opinion

Safety Guidelines for Magnetic Resonance Imaging Equipment in Clinical Use

Prudent Avoidance Policy on Siting Telecommunication Towers and Antennas

2007 WHO Research Agenda for Extremely Low Frequency Fields

Guide Electromagnetic fields in working life A guide to risk assessment. Kjell Hansson Mild Monica Sandström

MEDICAL DEVICE GUIDANCE

Non-ionizing electromagnetic radiation monitoring in Greece

Regulation for wireless telecommunication equipment

RF EXPOSURE LIMITS AND TESTING REQUIREMENTS

Clean, Green and Safe Management System

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Exposure Assessment of a High-Resonance Wireless Power Transfer System under the Misaligned Condition

Attenuation Measurements of Materials Used in Construction of Buildings


Aspects of remote monitoring and recording system of non-ionizing electromagnetic radiation

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

EMC Standards: Standards of good EMC engineering

EMC & Wireless Certification

Selective measurement of high frequency electromagnetic

TEST REPORT EN (1997) +A1 (2001)

Effect of Metallic Materials on SAR

ETSI EN V1.1.1 ( )

EMR EMISSIONS FROM REMOTE AREA POWER SUPPLY EQUIPMENT

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

A New Framework for the EU EMC Directive

Product Safety and RF Exposure for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations

Body SAR and EU. B. Derat

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

Nardalert. narda. User s Guide. Safety Test Solutions. communications company

Thermal Effects of Mobile Phones

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Measurement, analysis, and monitoring of RF signals

EMR COMPLIANCE HOW TO ENSURE YOUR NATA ACCREDITED CONTRACTOR IS ABLE TO PROVIDE A NATA ENDORSED REPORT

Current Probes. User Manual

Technical Specification. Cellular Base Station and Repeater System

OpenWay Radio Frequency FAQ

Non-Ionizing Electromagnetic Radiation

DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

Transcription:

Safety in electromagnetic fields EMF Directive 2013/35/EU

Corporate responsibility, worker safety The long road to implementation The first Directive on the minimum health and safety requirements regarding the exposure of workers to the risks arising from electromagnetic fields was published as far back as 2004. Primarily, concerns from among medical circles led to the repeal of this initial version and its replacement by the new EMF Directive 2013/35/EU, which came into force in June 2013. EU member states must implement this Directive in their national laws by 1st July 2016. The EU member states are required to enact the necessary legislative and administrative regulations by 1 st July 2016. New Directive with practical values All the known direct biophysical effects and indirect effects of electromagnetic fields are included in the new Directive in order to guarantee the health and safety of workers. The specified limit values and personal protective measures have been determined on the basis of the latest scientific findings and refer exclusively to the scientifically proven direct short-term effects. And it s good to know that the Directive is not intended to cancel any existing, more stringent national limit value regulations. Now is the time for companies to act To protect workers, all places of work must be subjected to a risk assessment according to the requirements of the EMF Directive. The physical quantities, exposure limit levels and action levels specified in the Directive are based on the recommendations of the International Commission for Non-Ionizing Radiation Protection (ICNIRP). Of help here is the reference to a range of indicators and standard situations, which have been made available in guidelines. The sanctions that can be applied to a company in the event of a violation vary from one EU state to another. Whatever the case, these must be effective, appropriate, and deterrent.

The main points of EMF Directive 2013/35/EU of 26 June 2013 The Directive envisages the performance of a risk assessment for all places of work within the EU, with the result being documented, for example in the form of suitable measurements. The responsibility for doing this is borne by the employer, who must additionally take measures to prevent or reduce the risks. The Directive applies to exposure to electric, magnetic, and electromagnetic fields with frequencies from 0 Hz to 300 GHz. Biophysical effects A distinction is made between two types of direct biophysical effects that can be caused by electromagnetic fields: Thermal effects such as tissue heating through energy absorption. These mainly occur in fields in the frequency range from 100 khz to 300 GHz. Stimulation of muscles, nerves and sensory organs. These effects are mostly caused by fields in the frequency range from 0 Hz to 10 MHz. The Directive names other indirect effects such as spark discharges, contact currents, interference with medical electronic equipment (such as cardiac pacemakers or other implants), as well as the projectile risk from ferromagnetic objects in static magnetic fields. Exposure limit values and action values All exposure limit values (ELVs) refer to the field values within the human body. In this regard, the Directive defines ELVs for sensory effects: Limits for transient disturbed sensory perceptions ELVs for health effects: Limits for adverse thermal or non-thermal health effects As it is impossible to measure the field values within the human body and to otherwise determine such values would involve highly complex calculations, the Directive defines so-called action levels. Action levels (ALs) are field values at the place of work up to the level of which the exposure level values are deemed to have not been exceeded. These can be measured directly. A distinction is made between Employers obligations Employers must ensure that the exposure limit values are not exceeded. They can use emission data provided by equipment manufacturers measurements, or calculation to assess the risks and determine the exposure levels. The assessment must be performed by a professional service or persons, repeated at appropriate intervals, and documented in a form that is traceable. In addition, the Directive obligates employers to undertake measures to avoid or reduce the risks, to inform employees and / or their representatives of such risks and explain the possible consequences or effects. The risk of injury can also be reduced by means of personal protective equipment (e.g. warning devices). This is particularly prudent where increased exposure levels can occur in variable areas of work. Exceptions Special regulations apply to research and development, and the use of magnetic resonance imaging (MRI) in the medical field. Differing protection systems can be used in operational military equipment or during military action. Here, too, care must be taken to ensure that effects detrimental to health and any safety risks are avoided. Low action levels (Low ALs) for sensory effects High action levels (High ALs) for health effects Protective or preventive measures must be taken as soon as the low ALs are exceeded.

Measured verification of action levels according to Directive 2013/35/EU Wideband measuring devices Selective measuring devices Personal protection devices Non-thermal effects from 0 Hz to 10 MHz ELT-400 THM1176 EHP-50F EHP-200A Thermal effects from from 100 khz to 300 GHz NBM-520 NBM-550 SRM-3006 Nardalert S3 RadMan Limit values for non-thermal effects: Exposure limit values and action levels in the frequency range from 0 Hz to 10 MHz Action levels for electric fields (E) Action levels for magnetic fields (B) Electric field E Magnetic field B Limit values for thermal effects: Exposure limit values and action levels in the frequency range from 100 khz to 300 GHz Action levels for electric fields (E) 6-minute average values (RMS) Action levels for magnetic fields (B) 6-minute average values (RMS) Electric field E Magnetic field B

Measurement solutions from Narda: Protection across the entire bandwidth Narda is one of the leading providers of high quality, tailor made measurement solutions. The comprehensive product range for human safety in electromagnetic fields (EMF) comprises wideband measuring devices, selective measuring instruments, monitoring systems, and personal monitors. Original measurement accuracy means security When something happens, being able to prove the accuracy of measurements can be vital. So it is best to be on the safe side with a regularly calibrated measuring device. That is why Narda, as an accredited calibration lab for field strength measuring devices, offers an additional bonus for even more reliability and security with three of the most modern calibration labs worldwide. Narda measuring devices for electric and magnetic fields, wideband or selective, from 0 Hz to 60 GHz. Personal Non-thermal effects safety devices THM, EHP, ELT RadMan, Nardalert Thermal effects NBM, SRM

roener-design.de Conforms to EMF Directive Narda Safety Test Solutions GmbH Sandwiesenstraße 7 72793 Pfullingen, Germany Tel. +49 7121 97 32 0 Fax +49 7121 97 32 790 info.narda-de@l-3com.com www.narda-sts.com Narda Safety Test Solutions 435 Moreland Road Hauppauge, NY11788, USA Phone +1 631 231-1700 Fax +1 631 231-1711 NardaSTS@L-3COM.com www.narda-sts.us Narda Safety Test Solutions srl Via Leonardo da Vinci, 21/23 20090 Segrate (MI) ITALY Phone +39 02 26 998 71 Fax +39 02 26 998 700 support@narda-sts.it www.narda-sts.it NSTS 07/15-ME-D314A Technical advances, errors and omissions excluded. Narda Safety Test Solutions 2014. The name and logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. Trade names are the trademarks of their respective owners.