Model: EB-50GU-A Standard Package

Similar documents
Model: DC-A2IO Advanced HVAC Controller

Air Conditioning Control System Centralized Controller AE-200A/AE-50A AE-200E/AE-50E Instruction Book Web Browser for Initial Settings

Temperature & Humidity SMS Alert Controller

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Power supply unit Model: PAC-SC50KUA

IntesisBox KNX LG Air Conditioning

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Research RF Sputtering Packages

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

TrueAlarm Fire Alarm Systems

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Electronic Control Devices The European Product Catalogue 2007

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox KNX Mitsubishi Heavy Industries AC

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

KNX Panasonic Air Conditioners

Multi-Range Programmable DC Power Supplies 9115 Series

Workshop 7 PC Software - Tracker

Electronic Control Devices The European Product Catalogue 2007

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Modbus Server SAMSUNG Air Conditioners

Centralized Controller Model: AG-150A

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

PRODUCT LIST Facility DDC Access WebXL DDC

8-Port PoE Network Switch

3.5in esata USB Dual Removable SATA RAID External Hard Drive Enclosure StarTech ID: S352U2RER

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Thyristor-controlled power supplies and battery chargers

Duct Humidity Transmitter

IntesisBox Modbus Server SAMSUNG Air Conditioners

Variable Air Volume - VAV

DCS Series 1 kw, 1.2 kw, & 3 kw

MAJORSINE Power Inverter

4-CH Hybrid Digital Video Recorder

HD WIRELESS VIDEO SECURITY SYSTEM WIRELESS CONVENIENCE, HIGH DEFINITION QUALITY

Data Loggers for Real Time Temperature Monitoring - WiFi

Communicate and view data from meters with one simple device

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

CE6500 Energy Recovery Ventilator

Network Video Recorder

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Cisco 7816-I5 Media Convergence Server

Power Proportional Distribution (PPD)

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

1.44 kw Programmable DC Power Supplies XLN Series

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

WATCH OVER YOUR WORLD FROM ANYWHERE IN THE WORLD

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Sales Bulletin #CT016a

Rack mounted telephone- and leased line modem for industrial applications

Temperature & Humidity SMS Alert Controller

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

VAC 50/60Hz Power Adapter

NETWORK SOLUTIONS.

To ensure you have the appropriate equipment and settings please review the following: Software and Hardware Recommendations.

Chassis, Power Supply, and Element Management

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

XIV. Electrical / Electronics

Specifications for the Gateway M1300 Tablet PC

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

SECURITY CAMERA SYSTEM

FROM ANYWHERE IN THE WORLD

Application Server V240 Platform

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

Recording. Smart recording (depending on the camera models)

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Sage Grant Management System Requirements

IntesisBox KNX Modbus RTU master

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

T Zone Weekly Timer

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Telephone- and leased line modem for industrial applications TD-36

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

SMS GSM Alarm Messenger

O pen F ram e Tou c h M on i t or

Network Video Recorder Quick Operation Guide

QuickSpecs. HP Compaq t5525 Thin Client. Overview

Overview of the Cisco 2500 Series Access Server

Sympodium Interactive Pen Display

, User s Manual

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

BM ADAPTER Model: BAC-HD150

Megapixall Security Tools & Accessories

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION


Network Video Recorder Quick Operation Guide

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Smart Thermostat page 1

TrueAlarm Fire Alarm Systems

Transcription:

Model: EB-50GU-A Standard Package Job Name: Schedule Reference: Date: EB-50GU-A STANDARD PACKAGE EB-50GU-A Centralized Controller PAC-SC51KUA Power Supply Monitoring Annual and Weekly Scheduling, Sending Error Email, Online Maintenance Tool, Interlock Control and Data Monitoring OPTIONAL SOFTWARE SW-Charge: Tenant Billing - Calculates per tenant CITY MULTI energy usage based on the refrigerant capacity used of the outdoor unit(s) divided among the associated indoor units - Requires TG-2000 software Ver. 6.40 or later installed on a dedicated, networked PC connected to a RS-485 watt hour meter (WHM) SW-PWeb: Online Personal Browser - Allows individual users (up to 50) to control their respective zone conditions via personal networked PC with or without local remote controllers installed in the space EB-50GU-A CENTRALIZED CONTROLLER SPECIFICATIONS Manages up to 50 Indoor Units individually, in a group or in a collective batch operation Supports dual set point functionality (connected model dependent) Displays: - CITY MULTI compressor speed and hi/low pressure - Advanced HVAC Controller (DC-A2IO) input/output status - Indoor unit free contact input/output status - Space Temperature and Humidity (from Smart ME or AI controller) - Error code - Unoccupied setback up temperature range Functions - Hold function (temporarily disables schedules indoor unit model dependent) - Initial setting - Operation data back-up Permits or prohibits remote controller functions: - On/Off - Change Operation Mode - Change Set point Temperature - Filter Status - Change Fan Speed - Change Air Direction External input/output signals can be used for batch operations such as Start/Stop and Emergency Stop (Requires PAC-YG10HA) Temperature set point range limits can be set for local remote controllers User defined indoor unit functions: - On/Off - Monitoring and Operation - Operation mode: Auto* (Dual or Single set point) Cool Heat Fan Drying Setback* Note: *R2 Series only (connected equipment dependent) Temperature Setting Fan Speed Airflow Direction Monitoring and Control: - CITY MULTI indoor units - M & P Series units (Requires M-Net adapter) - Lossnay units - PWFY hydronic heat pump units - DIDO controllers - CITY MULTI DOAS - Interlock setting enables integration of general equipment inputs/outputs and indoor units Scheduling - Daily - Annually - Five pattern weekly seasonal schedule Twenty four scheduled events per day, indoor unit model dependent: - ON/OFF - Mode - Temperature Setting - Vane Direction - Fan - Speed - Operation Prohibits Trend data: - Fan operation time - Thermo-on time - Set temperature - Room temperature - AI Controller temperature and humidity (Requires PAC-YG63 MCA, 2 inputs total for each controller)

Models: EB-50GU-A - System Configuration 4. System configuration The figure below only shows the transmission cable connections. Power cables are omitted. Power supply unit PAC-SC51KUA (sold separately) Power (24 VDC) outdoor unit (Y) Centralized controller EB-50 [000] LAN AHC Indoor unit Local remote controller Advanced HVAC CONTROLLER transmission cable remote controller cable TB7 [051] TB3 Group 2 Group 1 Numbers in the parentheses indicate address numbers. [004] [005] [001] [002] [003] outdoor unit (R2) TB7 [056] [057] TB3 BC controller Group 3 LOSSNAY [006] [007] [008] [009] [010] ME [106] AHC [201] Mr. Slim/M- and P-Series outdoor unit Mr. Slim/M- and P-Series outdoor unit [11] [12] adapter Group 4 Group 5 14 Fig. 4-1

EB-50GU-A Centralized Controller Model: EB-50GU-A - Specifications Specifications Power Supply Controller Drive 24VDC ± 5% *Power Supply: PAC-SC51KUA Operating Range -10 C +55 C [+14 F +131 F] Temperature Environmental Conditions Non-operating Range -20 C +60 C [-4 F +140 F] Humidity 30-90% RH (No condensation) Weight 2 lbs. (0.7 kg) Dimensions (W x H x D) 6-1/2 4-3/4 1-13/16 in. (165 120 46 mm) Web Browser Requirements CPU Memory Screen Resolution Compatible Browser Windows Macintosh Onboard LAN Port or LAN Card Other Requirements 1 GHz or faster 512 MB or more 1024 x 768 or higher recommended Microsoft Internet Explorer 8.0 Microsoft Internet Explorer 9.0 * Java execution environment is required. (Oracle Java Plug-in Ver. 1.7.0_11) * Install Oracle Java Plug-in that is appropriate for your operating system. When using a 64-bit Internet Explorer, install a 64-bit Java Plug-in. * The version of the Oracle Java Plug-in can be verified by clicking [Java] in the Control Panel. Safari 6 * Java execution environment is required. (Oracle Java Plug-in Ver. 1.7.0_11) * The version of the Oracle Java Plug-in can be verified by clicking [Help]-[Installed Plug-ins] on the Safari browser. One connector (100BASE-TX) Pointing device such as a mouse.

External dimension Model: EB-50GU-A - Dimensions Unit:mm[in.] 225 (8-7/8) 205 (8-3/32) 165 (6-1/2) 46 (1-13/16) 50 (1-31/32) 60 (2-3/8) 120 (4-3/4) L-fitting 30 (1-3/16) 10 (13/32) 4.5 (3/16) 4.5 (3/16) 36 (1-7/16) Notes:

POWER SUPPLY (PAC-SC51KUA) SPECIFICATIONS Source Power Requirements Output Voltage / Current Load Capacity Environmental Conditions Dimensions (H x W x D) Weight Model: PAC-SC51KUA Rated input voltage and current: 100-240VAC ±10 %; 0.8A 0.4A; 50Hz/60Hz single-phase. Fuse: 6.3A time delay type. Output voltage/current: : 23.0 32.0VDC; DC power supply: 24VDC ±5% 0-0.75A. Dimensions: (H x W x D) 6-11/16 x 10-11/16 x 2-7/8. Weight: 3-1/8 lbs. Indoor installation in field-supplied control panel or surface mount attachment (sold separately). Installation Environment Specifications Rated Input Voltage / 100-240VAC ±10%; 0.8A - 0.4A, 50/60Hz Current single phase Fuse: 6.3 time delay type (IEC127-2 S.S.5) 23.0-32.0VDC DC Power Supply 24VDC ±5%; 0-0.75A One EB-50GU-A Centralized Controller Operating Range 14-131 F (-10 - +55 C) Temperature -4 - +140 F (-20 - Storage Range +60 C) Humidity 30-90% RH (no condensation) 6-11/16 x 10-11/16 x 2-7/8" (169 x 271 x 72mm) 3-1/8 lbs. (1.4kg) Indoor installation in field-supplied control panel or surface mount attachment (sold separately). PAC-SC51KUA POWER SUPPLY DIMENSIONS 271 (10-11 /16) 90 (3-9 /16) 72 (2-7 / 8) 130 (5-1 / 8) 155 (6-1 / 8) 169 (6-11 / 16) T TB2,TB3 TB1 FORM# EB-50GU-A Standard Package - 201311 1340 Satellite Boulevard Suwanee, GA 30024 Tele: 678-376-2900 Fax: 800-889-9904 Toll Free: 800-433-4822 www.mehvac.com