Palltronic Flowstar LGR Test Instrument

Similar documents
USD2555a. Palltronic. Flowstar IV. Filter Integrity Test Instrument and MUX Extension

Application Note USD3013. Monoclonal Antibody Production in Suspension CHO Culture Using Single-Use PadReactor Mini Bioreactor

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Allegro TM Single-Use Tangential Flow Filtration System

Acrodose PL System. Enhanced Patient Safety. A New Platform for Pre-storage Pooling and Testing of Leukoreduced Whole Blood Derived Platelets

Cadence Acoustic Separator

Resolute FM mm I.D. Chromatography Columns for Pilot or Production Use

Agilent 87421A/87422A Power Supply

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

1.5 GHz Active Probe TAP1500 Datasheet

Instructions For Use USD Remote Control of the Palltronic Flowstar IV Integrity Test Instrument Using OPC Communication

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Zebra Link-OS Environment Version 2.0

Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Cisco Conference Connection

Barcode-Based Patient Safety Initiatives in Hospital Pharmacies

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Voice Internet Phone Gateway

Building Technologies

Reducing Cycle Times and Work in Process Management Costs: Aerospace and Defense Industry

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

GenStore Archive Cabinet

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

KNC Model 3666 Automatic Pressure Calibration System

CISCO CONTENT SWITCHING MODULE SOFTWARE VERSION 4.1(1) FOR THE CISCO CATALYST 6500 SERIES SWITCH AND CISCO 7600 SERIES ROUTER

Agilent 4339B/4349B High Resistance Meters

Barcode Labeling in the Lab Closing the Loop of Patient Safety

QuickSpecs. HP Wireless Keyboard and Mouse. Models

Updating the QIAcube operating software

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

einvoice A fully automated digital solution for companies of all sizes

Step 4. Advanced inventory and storage capabilities

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Agilent 4338B Milliohm Meter

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

NI USB-6008/6009 OEM USER GUIDE

Agilent U2000 Series USB Power Sensors

NEW LMS 400. The LMS 400 Laser Measurement System Pole position for robotics and material handling. Product Information

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

White Paper. 10 Reasons to Choose Image-based Barcode Readers

Reporting practices for domestic and total debt securities

Cisco CNS NetFlow Collection Engine Version 4.0

USD Pall Filter Housings for Depth Filter Modules. Stainless Steel Housings designed for the Biopharmaceutical Industry

BT Premium Event Call and Web Rate Card

Motion Graphic Design Census. 10 hrs. motiongraphicdesigncensus.org. 9 hrs.

Responding to Healthcare s Most Urgent Business Issues. Gundersen Lutheran Health System Case Study

Agilent 8762/3/4A,B,C Coaxial Switches

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000)

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

Image Lab Software for the GS-900 Densitometer

10 Reasons to Choose Image-based ID Readers. White Paper

RTLS 101 What It Is and Why You Need It

Application Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges

Release Notes: PowerChute plus for Windows 95 and Windows 98

Global Economic Briefing: Global Inflation

Link-OS Printer Operating System Syslog AppNote October 5, 2014

IFS ApplIcAtIonS For Document management

Smart. Scalable. Simple.

Sales and Customer Support FAQ

CISCO NETWORK CONNECTIVITY CENTER

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Agilent P940xA/C Solid State PIN Diode Switches

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

CISCO PIX SECURITY APPLIANCE LICENSING

Agilent Television Power Consumption Testing. Application Note

Exceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES. VERTEX Industrial Floor Scales Heavy-Duty Design

Handheld portable appliance testers

World Consumer Income and Expenditure Patterns

PCI Express 1.0 (2.5 GT/s) Protocol Test

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

2012 Country RepTrak Topline Report

NEBS 2009 Optimization of Telecom Networks Through Energy Efficiency Eitan Amon Type Approval Team Leader Comverse Ltd.

Microsoft Voucher Ordering Processes

FACT SHEET Global Direct Selling

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Agilent Automotive Power Window Regulator Testing. Application Note

Performance 2015: Global Stock Markets

HIGH-DENSITY PACKET VOICE DIGITAL SIGNAL PROCESSOR MODULE FOR CISCO IP COMMUNICATIONS SOLUTION

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Performance 2016: Global Stock Markets

IBM Global Services. IBM Maintenance Services managed maintenance solution for Cisco products

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Cisco IT Data Center and Operations Control Center Tour

3 Steps to Transform your Business with Next-Generation Networking

E-Seminar. Financial Management Internet Business Solution Seminar

Micro Motion ELITE CMFS Series Meter

Quantum View Manage Administration Guide

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

DRIVE VALUE ACROSS YOUR SUPPLY CHAIN WITH CHIP-BASED RFID SERIALIZATION A simpler, more cost effective solution for deploying item-level tagging

THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION

TekSmartLab TBX3000A, TSL3000B Datasheet

CISCO METRO ETHERNET SERVICES AND SUPPORT

Performance 2013: Global Stock Markets

VT-S730. Omron's 3D-SJI For Efficient Manufacturing of High-quality Products. Best the Minimum Q cost! PCB Inspection System VT-S730 NEW

Transcription:

USD3015(2) Palltronic Flowstar LGR Test Instrument Fast fully traceable testing of single-use systems at point-of-use Single-use technologies in formulation and filling applications are gaining fast market acceptance both in clinical and manufacturing operations. This has led to an increase in requirements in validation and robustness of single-use systems. As a result, point-of-use testing of single-use systems is quickly becoming a requirement. At Pall, we set up very high standards with regards to the design and validation of the manufacturing process of Allegro single-use systems and operators should be well-trained in unpacking, handling, and installing single-use systems. There is still a requirement in the biopharmaceutical industry to confirm the absence of leaks prior to or after use from a risk management perspective. The availability of an easy and reliable point-of-use leak test provides end users with the confidence that the singleuse system they are going to use is leak-free and has not been damaged during the installation, and/or use or storage process.

The Palltronic Flowstar LGR test instrument enables point-of-use leak testing of single-use systems up to 200 L nominal volume and provides the ability to test the integrity of the filters within the single-use systems. This technology has an extremely small footprint, is easy to use, and is compliant with current regulatory standards. The instrument allows end users to test endless configurations of single-use systems and filters, with one device, without compromising the sterility of the system. Designed for use in the vaccines, biotech, and pharmaceutical markets and with a specific focus on formulation and filling applications where sterility of the single-use system needs to be maintained, the Palltronic Flowstar LGR instrument meets all of the key user needs such as: Robust true point-of-use test to confirm the absence of damage to single-use systems during transportation, installation and/or use Maintains sterility of the system during testing Fast: leak testing of single-use systems can be achieved within 15 minutes Flexible: ideal for both pre and post-use integrity tests of filters integrated in single-use systems Compliant: full traceability of the system data and the testing data according to CFR21 part 11 Features and Benefits Features Technology All configurations of single-use single-use systems (nominal volume < 200 L) can be tested Leak detection is based on flow measurement Different leak test pressures can be used Sterilizing filters integrated into the single-use system can be integrity tested pre and post-use Test can be carried out with air or nitrogen Ease of Use True point-of-use test unit Storage of individual recipes for the testing of single-use systems Barcode reader supplied for selection of test program and input of system part number and batch number Short test times less than or equal to 15 mins Small footprint for test unit Benefits Very high degree of flexibility, can test systems with or without biocontainers Exact volume of the systems does not need to be calculated or measured Easy input of threshold values for any configuration of single-use system High pressure testing for single-use systems without biocontainers is providing increased test sensitivity Low pressure testing is preventing damages to 2D and 3D biocontainers in tested systems Test unit has multiple functions reducing equipment requirements and maximizing footprint usage in the cleanrooms Nitrogen can be used for pre-use testing of systems for oxygen sensitive products in final filling applications Test is performed on the single-use system as it will be used during the process, removes additional risks due to extra handling Test parameters are stored in test programs that are aligned with system part number Prevents transcription errors Avoids impact on cycle time of the manufacturing process Minimizes impact on layout of the manufacturing suite Quality and Regulatory Fully validated and CFR 21 part 11 compliant software Easy and secure connection of the test unit to the single-use systems Full audit trail of tests provided with electronic signatures Test data can be recorded, printed or downloaded and stored in a compliant manner Quick connection through Stäubli fitting Prevents breaches in sterility with the inclusion of a sterile vent filter in the single-use system and protecting the boundary of the system 2

Direct Flow Measurement The Palltronic Flowstar LGR integrity test instrument utilizes a method that was developed by Pall for use in integrity test instruments and patented as volume-dosed flow measurement technology. Unlike pressure hold or pressure decay based tests, Pall s volume dosed measurement system is completely independent of upstream volume and offers clear advantages in terms of reduced overall test time, accuracy, reliability, and test reproducibility. Testing Capabilities of the Palltronic Flowstar LGR instrument Flow/Pressure Technical Test Measurement Specs Notes Single-use Flow Test pressure range: Results are PASS System 50-500 mbar NO LEAK Leak Measuring range: DETECTED or 0.1 ml/min FAIL LEAK 1000 ml/min DETECTED. Sensitivity up to 30 µm (volume dependent) Leak Flow Test pressure range: Results are PASS 50-6,500 mbar NO LEAK Resolution: 0.1 ml/min DETECTED or Measuring range: FAIL LEAK 0.1 ml-1000 ml/min DETECTED. Forward Flow Accuracy: ± 3% of value Recommended Flow or ± 0.05 ml/min test for integrity whichever is greater testing filters Resolution: 0.1 ml/min integrated in (0.01 ml/min for flows single-use systems below 10 ml/min) Measuring range: 0.1 ml/min 1000 ml/min Water Flow Accuracy: ± 3% of value Filter test only Intrusion or ± 0.02 ml/min whichever is greater Resolution: 0.01 ml/min Measuring range: 0.03-50 ml/min Unique design Built to GAMP 5 guidelines LAN and WLAN networking capabilities USB connectivity can be used with flash drives, barcode readers, printers Intuitive user interface with color touch screen Electronic Data Handling and Remote Control Range of automation options including: OPC UA ProfiBUS DP (optional) DeviceNET (optional) The Palltronic Flowstar LGR instrument can synchronize with network clocks and can export test results directly to a Windows shared folder. Electronic print options include compatibility with network printers and automatic file generation (PDF and/or XML format) on a USB flash drive or Windows shared folder. Leak Testing of Single-use Systems Containing Flexible Biocontainers Systems containing 2D biocontainers When testing a single-use system with a 2D biocontainer, the test gas must be completely vented when the test is complete. Pall s air evacuation device (patent pending) is designed to fit directly into the Allegro tray that is already used as biocontainer supporting hardware. Simply place the air evacuation device in the tray, lift the silicon cover, insert the 2D biocontainer handle into the retaining clasp, and lay the silicone cover over the top face of the biocontainer. As the single-use system leak test runs, the biocontainer will inflate and lift the silicone cover with it. When the test is complete the weight of the cover will result in full evacuation of the air from the bag without any operator handling. The full system can remain in place and does not have to be removed from the air evacuation device prior to further processing. www.pall.com 3

Point-of-use testing of single-use systems Unpack the single-use system Install the system how it will be used during processing so that it does not need to be handled after the test. When applicable, position the 3D biocontainers within the air evacuation devices and/or totes. Systems containing 3D biocontainers When performing the leak test on single-use systems containing 3D biocontainers, an Allegro plastic mesh must be placed in the Allegro tote. The mesh ensures that as the 3D biocontainer is pressurized it does not directly press against the side of the tote, which could result in a sealing effect during pressurization and mask a leak, giving a false-pass test result. Unlike systems containing 2D biocontainers, systems containing 3D biocontainers can remain inflated prior to use, provided an air vent filter is present at the top of the 3D biocontainer. Connect the Palltronic Flowstar LGR instrument directly to the upstream side of the single-use systems vent or liquid filter. This ensures the sterile boundary is maintained. Scan the part number and batch number barcode of the Allegro single-use system with the Palltronic Flowstar LGR bar code scanner. Enter the operator name and any other necessary information for record keeping and press the start button on touch screen. The leak test will be completed in approximately 15 minutes, after which, the test result will be displayed. A successful test will result in the message PASS- NO LEAK DETECTED. 4

Technical Specifications Physical dimensions (nominal) Weight: 10 kg (21.6 lbs) Width, height, depth: 348 mm x 205 mm x 483 mm (13.7 in. x 8. in. x 19 in.) Testing capabilities SUS leak test (for volumes up to 200 L 200 L nominal Leak test (for volumes up to 200 L nominal) Forward flow test Water intrusion test Function tests Self test Flow check test Printer test Network test Other functions Cleaning function Test program transfer function Configuration transfer function Access management transfer function Test result export function Backup function Language options English, Japanese Language files on the instrument are constructed such that other languages may be added as necessary. Communication ports USB Ethernet Wireless ethernet network Accuracy Forward flow test: ± 3% of reading or ± 0.05 ml/min, whichever is the greater Water intrusion test: ± 3% of reading or ± 0.02 ml/min, whichever is the greater Measuring Range SUS leak test: 0.1 m-1000 ml/min Leak test: 0.1 m-1000 ml/min Forward flow test: 0.1-1000 ml/min Water intrusion test: 0.03-50 ml/min Resolution SUS leak test: sensitivity up to 30 µm (volume dependent) Leak test: 0.1 ml / min Forward flow test: 0.1 ml/min (0.01 ml/min for flows below 10 ml/min) Water intrusion test: 0.01 ml/min Calibration The calibration of the Palltronic Flowstar LGR instrument includes a calibration of the pressure transducers and the flow measurement calibration limits: Pressure measurement: ± 0.33% of full scale Flow measurement: ± 3% of measurement Electrical Data Voltage: automatically adjusted between 100-240 V AC Input frequency: 50 Hz / 60 Hz Power: typically 75 W (peak 150 W) Fuse: 3.15 A slow blow External vent valve: 24 V DC Screen Size: diagonal 264 mm (10.4 in.) Resolution: 1024 x 768 pixels Features: color, illuminated background, adjustable contrast, touch screen Pneumatic Connections Compressed air inlet: Stäubli nipple Compressed air outlet: Stäubli coupling Vent: Hose connection 8 mm outer diameter Pneumatic specifications Maximum gas supply pressure: 8000 mbar (116 psi) Minimum gas supply above test pressure (Standard): Flow range: 0.01-150 ml/min 1000 mbar (14.5 psi) Flow range: 150-1000 ml/min 2000 mbar (29.0 psi) Test pressure range: 50-6500 mbar (0.7-94 psi) Internal printer Thermal printer Printer resolution: 832 dots/line Lifetime of printout: 10 years depending on storage conditions Printer speed: 12 mm/sec (0.5 in./sec) printout with graphic Paper width: 112 mm (4.4 in.) Paper roll diameter: 50 mm (1.9 in.) External Printing Function External USB printer External network printer (The printer should be capable of handling the printer language PCL5e) Virtual printing to PDF or XML file format Environmental Conditions Splash proof: IP54 Operating temperature: +5 C to +50 C Storage temperature: -20 C to +70 C Humidity: 95% RH (no condensation) Operating System Linux (The source code which falls under the GNU, general public license stored on the USB flash drive supplied with the instrument) www.pall.com 5

Ordering Information Part Number Description FFS04R-LGR Palltronic Flowstar LGR instrument for testing single-use assemblies AEDLGR005 Air evacuation device for a 5 liter biocontainer to fit an Allegro tray with part number LGRTPE20L AEDLGR010 Air evacuation device for a 10 liter biocontainer to fit an Allegro tray with part number LGRTPE20L AEDLGR020 Air evacuation device for a 20 liter biocontainer to fit an Allegro tray with part number LGRTPE20L AEDLGR050 Air evacuation device for a 50 liter biocontainer to fit an Allegro tray with part number LGRTPE50L MSHLGR50 Mesh and frame for the 50 liter 3D Allegro tote MSHLGR100 Mesh and frame for the 100 liter 3D Allegro plastic tote MSHLGR200 Mesh and frame for the 200 liter 3D Allegro plastic tote Corporate Headquarters Port Washington, NY, USA +1.800.717.7255 toll free (USA) +1.516.484.5400 phone biopharm@pall.com e-mail European Headquarters Fribourg, Switzerland +41 (0)26 350 53 00 phone LifeSciences.EU@pall.com e-mail Asia-Pacific Headquarters Singapore +65 6389 6500 phone sgcustomerservice@pall.com e-mail Visit us on the Web at www.pall.com/biopharm E-mail us at biopharm@pall.com International Offices Pall Corporation has offices and plants throughout the world in: Argentina, Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, India, Indonesia, Ireland, Italy, Japan, Korea, Malaysia, New Zealand, Norway, Philippines, Poland, Russia, Singapore, South Africa, Spain, Sweden, Switzerland, Taiwan, Thailand, United Kingdom, and Vietnam. Distributors in all major industrial areas of the world. To locate the Pall office or distributor nearest you, visit www.pall.com/contact. The information provided in this literature was reviewed for accuracy at the time of publication. Product data may be subject to change without notice. For current information consult your local Pall distributor or contact Pall directly. 2015, Pall Corporation. Pall,, Palltronic and Allegro are trademarks of Pall Corporation. indicates a trademark registered in the USA and TM indicates a common law trademark. Filtration. Separation. Solution. is a service mark of Pall Corporation. 8/15, PDF, GN15.6337 USD3015 (2)