Fence SpecCheck Wheatland Tube Company 800 343 0124

Similar documents
Product Manual CLF-PM0610 (revised January, 2012)

Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1

MERCHANTS METALS SECTION ARMORLINK ALUMINIZED CHAIN LINK FENCE AND GATES 2014!

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

BASIC FENCE SPECIFICATIONS By: A-1 Fence Company Revised: 2012

SECTION CHAIN LINK FENCES AND GATES

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Chain Link Fence Manufacturers Institute Security Fencing Recommendations

TARIFF CODE and updates standard

Charter Township of Shelby Harry Reese Building Director

The Ornamental Aluminum Fence with No-Visible Fasteners

STANDARD FOR NON-FIRE RATED ROLLING DOORS

How To Protect A Swimming Pool

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

3224 Dutton Ave, Santa Rosa CA (707) Fencing For All Applications...

Accents & Accessories

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

SECTION PIPE HANGERS AND SUPPORTS

SWIMMING POOLS, SPAS AND HOT TUBS Section AG101 General.

What kind of fence do I want? USU, Logan, UT

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

Manufacturing, Supply & Quality Plan for Tower Bolts. SL Tower Bolt Market Penetration

MA BUILDING CODES ON SWIMMING POOLS SECTION 780 CMR 120.M

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

PART 1 GENERAL 1.1 SECTION INCLUDES

1.02 SYSTEM DESCRIPTION

FRACASSO SCAFFOLDING PS 720

Mechanical arms, belts and sheets

HIGH TENSION CABLE BARRIER

The replacement or modification of existing windows shall comply with the following requirements:

TORONTO MUNICIPAL CODE CHAPTER 447, FENCES. Chapter 447 FENCES. ARTICLE I Private Property

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

WIRE TIES FOR OVERHEAD LIFTING

Mobile Home Pre-Inspection Checklist

Safety Barrier Guidelines for Residential Pools Preventing Child Drownings. U.S. Consumer Product Safety Commission

Chapter 7 Plumbing Connections

UNIFIED FACILITIES CRITERIA (UFC) SECURITY FENCES AND GATES

MAST ARMS & POLES. Ornamental Pole Top & Bases

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

SECTION STORM DRAINAGE SYSTEM

Understanding Coating Weight Designations for Zinc-Based Coatings on Steel Sheet Rev 2.2 Jan-04

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

City of San Diego, CWP Guidelines

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection.

GUARDRAIL POST STEEL

Steel Fire Sprinkler Pipe

Dock Hardware & Accessory Products Catalog

Anodes and Misc Equipment

Section METAL STAIRS

SECTION GUARDA SECURITY WINDOW SCREENS

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

BUILDING A FENCE? THE CITY OF CAMBRIDGE REQUIRES THAT ALL FENCES WITHIN THE CITY CONFORM TO THE REGULATIONS OF FENCE BY-LAW

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Fittings REGULAR TENSION BANDS MEDIUM TENSION BANDS BEVELED TENSION BANDS

Dog Kennel WORLDWIDE

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

CHAPTER 7: Building Systems ROOFING SYSTEMS

CALIFORNIA CODES HEALTH AND SAFETY CODE SECTION This act shall be known and may be cited as the Swimming Pool Safety Act.

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

SECTION SERIES 1500 VINYL PATIO DOORS

Engineering Specifications

GUIDELINE SPECIFICATIONS

Fence Application Package

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

GATES, CATTLEGUARDS and PASSAGEWAYS. This factsheet looks at various options for allowing passage through fences for livestock, wildlife and people.

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Building Code Clarifications - 7. Fire Resistance

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Waterleaf ARB Application

Window Safety Product Overview Visit Vendors for Safety Product Demonstrations and information in the lobby.

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Preformed Metal Roofing and Siding

Perfection Spring & Stamping Corp E. Algonquin Rd. Mount Prospect, IL USA 411@pss-corp.com

STREETLIGHT SYSTEM GROUNDING AND BONDING

POST AND FRAME STRUCTURES (Pole Barns)

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Technical Data Honeycomb Door Leaf

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

Table 1 Mechanical Properties of Pipe Table 2 Section Properties of Pipe and Reinforcing Dowel The Fitting with the Rib

SECTION STORM DRAINAGE TABLE OF CONTENTS

ARCHITECTURAL. C.R. LAURENCE COMPANY Worldwide Manufa cturer and Supplier

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

Carton - Straight Link Machine Chain (Order Unit is Feet )

GUARDA PROTECTIVE SECURITY

EL LAGO BUILDING DEPARTMENT PERMIT ISSUANCE PROCEDURES As of February 20, 2013

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

Transcription:

Fence SpecCheck Wheatland Tube Company 800 343 0124 www.wheatland.com ASTM Specifications (May 2014) www.astm.org A53/A53M-12 Schedule 40 & 80 Pipe: Specification for Pipe, Steel, Black and Hot- Dipped, Zinc Coated, Welded and Seamless Schedule 40, schedule 80 and heavier pipe used for utility applications, hydrostatic and mechanical test requirements. Sometimes a specifier incorrectly specifies A53 schedule 40 for fence framework. Caution, A53 can be considered equal to F1083 schedule 40 fence pipe, based on how the A53 spec is presented F1083 may or may not be substituted. Wheatland Tube is a prime manufacturer of A 53 in the United States. A121-13 Barbed wire: Specification for Metallic-Coated Carbon Steel Barbed Wire A121 lists all types of barbed wire; that used for chain link fence is listed as follows: Design number 12-4-5-14R manufactured using 12 gauge twisted strand wire, 4-point, 14 gauge barbs spaced 5 inches on center Design number 12-4-3-14R requires the barbs to be 3 inches on center. Coating Type A Aluminum coated Coating Type Z - Class 3 Galvanized coated strand 0.80 oz/ft² Coating Type ZA Zinc-5% aluminum-mischmetal alloy (probably not available in the market at this time) A392-11a Galvanized chain link fabric: Specification for Zinc-Coated Steel Chain Link Fence Fabric (zinc coated after weaving or woven from zinc coated strand) Class 1-1.2 oz/ft² Class 2-2.0 oz/ft² A491-11 Aluminum coated, aluminized : Specification for Aluminum- Coated Steel Chain Link Fence Fabric 6 gauge - 9 gauge -10 gauge specifies a 0.40 oz/ft² coating 11 gauge specifies a 0.35 oz/ft² coating 11 ½ gauge specifies a 0.30 oz/ft² coating A817-12 Specification for Metallic-Coated Steel Wire for Chain-Link Fence Fabric and Marcelled Tension Wire The metallic coated wire specification for the wire used in the manufacturing of pre coated metallic chain link fabric and tension wire. 1

A824-01 (2012) 7 gauge coil spring wire: Specification for Metallic-Coated Steel Marcelled Tension Wire The specification lists only 7 gauge wire, metallic coatings are listed in A817 as follows: Type I - Aluminum coated 0.40 oz/ft² Type II - Galvanized/zinc coated Class 3-0.90 oz/ft² Class 4-1.20 oz/ft² Class 5-2.00 oz/ft² Type III Zinc-5% Aluminum Mischmetal ( galvinal, galfan ) Class 60-0.60 oz/ft² Class 100-1.00 oz/ft² B429-10e1 Aluminum Pipe: Specification for Aluminum-Alloy Extruded Structural Pipe and Tube F537-01 (2007) Wood: Specification for Design, Fabrication and Installation of Fences Constructed of Wood and Related Materials F552-02 (2013) Chain Link Terminology: Standard Terminology Relating to Chain Link Fencing F567-14 Chain link installation: Standard Practice for Installation of Chain Link Fence F626-14 Chain link fittings: Standard Specification for Fence Fittings F654-07 (2012) Residential Gates: Specification for Residential Chain Link Gates F668-11 Color coated fabric: Specification for Polymer Coated Chain Link Fence Fabric Important to note! The steel core wire is the specified wire gauge not the outside diameter of the polymer-coated wire. Type 1 Extruded Type 2a Extruded and adhered Type 2b Fused and adhered Polymer coating can be PVC or Polyolefin F900-11 Commercial swing gates: Specification for Industrial and Commercial Swing Gates Eight foot rule; no member horizontally or vertically should be greater than eight feet apart. 2

F934-96 (2013) Colors of coated chain link systems: Specification for Standard Colors for Polymer-Coated Chain Link Fence Materials Black - Olive Green Brown Dark Green F964-13 Rigid PVC Profiles: Specification for Rigid Poly (Vinyl Chloride) (PVC) Exterior Profiles Used for Fencing and Railing F969-11 Tennis court fence: Standard Practice for Construction of Chain Link Tennis Court Fence F1043-13 Commercial and Industrial Framework: Specification for Strength and Protective Coatings of Steel Industrial Chain Link Fence Framework Heavy Industrial Fence Framework requirements: Group IA - Schedule 40 F1083 hot-dip galvanized pipe Group IC - Wheatland WT 40 type product Group II - Roll-formed C post Group IV - Performance criteria future products, Wheatland WT 30 complies with this criteria F1083-13 Schedule 40 and schedule 80 Pipe: Specification for Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded, for Fence Structures Hot-dip galvanized pipe having a zinc coating of 1.8 oz/ft² outside and 1.8 oz/ft² inside, Regular Grade Sch 40= Yield Strength - minimum 30,000 psi. High Strength Grade Sch 40 = Yield Strength - minimum 50,000 psi. F1183-96 (2011) Aluminum alloy fabric: Specification for Aluminum Alloy Chain Link Fence Fabric F1184-05 (2010) Slide gates: Specification for Industrial and Commercial Horizontal Slide Gates Type I - Overhead slide Type II - Cantilever slide Class 1 - Steel or aluminum frame using external rollers Class 2 - Steel or aluminum frame using internal rollers 3

Important safety requirements! Roller covers and fall over guideposts are required for the Class 1 external roller gates. F1345-10a Galfan /Galvinal fabric: Standard Specification for Zinc-5% Aluminum-Mischmetal Alloy-Coated Chain-Link Fence Fabric F1379-95 (2013) Standard Terminology Relating to Barbed Tape F1553-11 Standard Guide for Specifying Chain Link Fence F1664-08 (2013) Polymer coated tension wire: Specification for Poly (Vinyl Chloride) (PVC) and Other Conforming Organic Polymer-Coated Steel Tension Wire Used with Chain-Link Fence Two gauges, 9 & 7, three classes of coatings, same as F668. F1665-08 (2013) Polymer coated barbed wire: Specification for Poly (Vinyl Chloride) (PVC) and Other Conforming Organic Polymer-Coated Steel Barbed Wire Used with Chain-Link Fence Strand wire has three classes of coatings, same as F668 F1712-11 High Security chain link fence: Standard Specification for Steel Chain Link Fencing Materials Used for High Security Applications F1908-08 (2013) Standard Guide for Fences for Residential Outdoor Swimming Pools, Hot Tubs, and Spas F1910-98 (2013) Specification for Long Barbed Tape Obstacles F1911-05 (2010) Standard Practice for Installation of Barbed Tape F1999-00 (2006) Installation of Rigid PVC profiles: Standard Practice for Installation of Rigid Poly (Vinyl Chloride) (PVC) Fence Systems F2000-10 Standard Guide for Fences for Baseball and Softball Fields F2049-11 Play area fencing: Standard Guide for Fences/Barriers for Public, Commercial, and Multi-Family Residential Outdoor Play Areas F2200-13 Electrically operated gate safety and design: Specification for Automated Vehicular Gate Construction 4

F2408-11 Ornamental galvanized steel tube fence: Standard Specification for Ornamental Fences Employing Galvanized Steel Tubing F2409-10 Guide for non residential pool fence Standard Guide for Fences for Non Residential Outdoor Swimming Pools, Hot Tubs and Spas F2453-14 Welded wire mesh fence fabric: Standard Specification for Welded Wire Mesh Fence Fabric (Metallic-Coated or Polymer Coated) for Meshes of 6 in² or Less, in Panels or Rolls, with Uniform Meshes F2548-12 Expanded metal for security applications: Standard Specification for Expanded Metal Fence Systems for Security Purposes F2589-11 Ornamental tubular steel fence: Standard Specification for Ornamental Fence Employing Tubular Pickets F2611-11 Chain Link Security Fence Design: Standard Guide for the Design and Construction of Chain Link Security Fencing F2630-07 Self-Closing Self-Latching Gates: Standard Guide for Self- Closing/Self Latching General-Purpose Gates F2631-07 Outdoor sports field s chain link fencing safety installation: Standard Practice for Installation of Chain Link Fence for Outdoor Sports Fields, Sports Courts and Other Recreational Facilities F2698-08 (2013) Skate Park fencing: Standard Guide for Fences for Above Ground and In-Ground Skate Park Facilities F2699-08 (2013) Water spray play area fencing: Standard Guide for Fences for Commercial and Public Outdoor Water Spray/Play Areas F 2780-09 Expanded metal security fence Standard Guide for Design and Construction of Expanded Metal Security Fences and Barriers F2781-10 Forced entry testing Standard Practice for Testing Forced Entry, Ballistic, and Low Impact Resistance of Security Fence Systems 5

F2814-09 Ornamental steel security fence Standard Guide for the Design and Construction of Ornamental Steel Picket Fence Systems for Security Purposes F2919/F2919M-12 Welded wire mesh panels Standard Specification for Welded Wire Mesh Fence Fabric (Metallic-Coated or Polymer Coated) with Variable Mesh Patterns or Meshes Greater than 6 in. 2 [3871 mm 2 ] in Panels F2957-13 Aluminum Ornamental Fence Standard Specification for Ornamental Aluminum Fence Systems F3000-13 Chain link privacy slats Standard Specification for Polymer Privacy Insert Slats for Chain Link Fabric and Privacy Chain Link Fabric Containing Pre Installed Privacy Slats Chain Link Manufacturers Institute Product Manual The Chain Link Fence Manufacturers Institute does not write specifications. The CLFMI Product Manual references current ASTM specifications. Federal Specification RR-F-191K/ GEN (Basically follow ASTM standards) RR-F-191/1F (2008) Chain Link Fabric (specification lists 6, 9 and 11 gauge) Type I - Zinc-coated 1.2 oz/ ft² unless 2.0 oz/ft² is specified Type II - Aluminum-coated, 0.40 oz/ft² coating for 6 and 9 gauge, 0.35 oz/ft² coating for 11 gauge Type III Aluminum Alloy, alloy 6061, temper T94 Type IV PVC coated, gauge specified is the core wire (the coating type is not listed in separate classes; specifier is to take into consideration type of coating to meet environmental conditions) Type V Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel wire 6

RR-F-191/2E (2006) Chain link gates, all types Gates are to be constructed using round pipe or square sections per RR-F-191/3E. Swing gates ASTM F900, slide gates ASTM F1184. External cantilever rollers shall be enclosed. Electrically operated gates must comply with ASTM F2200. RR-F-191/3E (2007) Fence posts and rails Class 1 - Steel pipe Grade A- ASTM F1083, hot-dipped galvanized schedule 40 pipe Wheatland Tube Co. is a prime U.S. manufacturer Grade B- ASTM F1043 Table 3 Group 1C, Wheatland WT-40 Class 2 - Aluminum alloy schedule 40 pipe Class 3 Formed steel C sections Class 4 Steel H-sections Class 5 Aluminum alloy H-sections Class 6 Steel square sections Class 7 Aluminum square sections A schedule lists post size based on the fence height RR-F-191/4F (2008) Chain link fence accessories Fittings, barbed wire, tension wire, basically all per ASTM standards AASHTO M-181 (American Association of State and Transportation Officials) AASHTO follows ASTM specifications and standards however there may be some differences because AASHTO does not update their specifications as quickly as ASTM AASHTO Designation: M 181-10 Standard Specification for Chain Link Fence Chain link fabric Type I Galvanized chain link fabric (zinc-coated steel) Class C - 1.2 oz/ft² Class D 2.0 oz/ft² Type II Aluminized chain link fabric (aluminum coated steel) Type III Aluminum alloy chain link fabric, alloy 6061-T89 or T94 Type IV PVC coated and other polymer coated steel chain link fabric (gauge is the core wire) Class A Extruded or extruded and adhered to Class B Thermally fused and bonded 7

Framework Grade 1 ASTM F1083 Schedule 40, 1.8 oz/ft² zinc coating inside and outside Wheatland is a prime U.S. manufacturer of galvanized sch 40 Grade 2 ASTM F1043 Group 1C, Wheatland WT-40 type product FAA (Federal Aviation Administration) AC 150/5370-10F (2011) Item F-162 Chain-Link Fences Follows ASTM Specifications 700 S. Dock Street, Sharon, PA 16146 800 343 0124 Fax 888 246 0457 fence@wheatland.com www.wheatland.com 8