Dual Laser InfraRed (IR) Thermometer

Similar documents
Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

Mini InfraRed Thermometer with Laser Pointer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Hygro-Thermometer + InfraRed Thermometer Model RH101

EzFlex Combustible Gas Leak Detector Model EZ40

User Manual. Humidity-Temperature Chart Recorder. Model RH520

ExStik TM ph Waterproof Meters

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

OPERATION MANUAL INFRARED THERMOMETER

User's Guide Integrating Sound Level Datalogger Model

Ground Resistance Clamp-On Tester

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

User's Guide. Integrating Sound Level Datalogger. Model Introduction

4-Channel Thermometer / Datalogger

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Ultrasonic Distance Meter. Operation Manual

User's Guide. Pinless Moisture Meter. Model MO257

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

USER GUIDE. LED Light Meter. Model LT45

DSM155 Digital LED Light Meter User s Manual DSM155

User Guide. Temperature and Humidity Datalogger. Model 42280

Available Options The IR-750B, IR-750EXB, IR-16 and IR-16EX series heat tracers are available with the options listed below.

Owner s Manual

Touchless Forehead Thermometer

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Temperature Humidity Meter

62 Max/62 Max + Infrared Thermometer

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Microwave Meter. Instruction Manual

User's Guide. Digital Sound Level Meter. Model

TABLE OF CONTENTS 11.0 WARRANTY

Thermistor Thermometer MODEL NO

Mold Alert... Operation Manual P0270

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Instruction Manual Temp 4/5/6 Temperature Meter Series

Pocket Tach 99 (PT99) Non-Contact Tachometer

Ground Resistance Clamp On Tester

INSTRUCTION MANUAL DTH Fax: (503)

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

RS DIGITAL THERMOMETER

User Guide. Model Insulation Tester / Megohmmeter

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Wireless Indoor/ Outdoor Thermometer

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding Руководство пользователя

Integrating Sound Level Meter and Datalogger

Wolverine Data PASS Portable Scanner User Manual V1.0

12 Volt 30 Amp Digital Solar Charge Controller

RT-1261A Ear and Forehead Thermometer Owner s Manual

Professional Thermohygrometer

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Temperature, Humidity & Dew Point Chart Recorder

T0118 T2118 T3118. Instruction Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

CO-220 Carbon Monoxide Meter

PR-2500 Portable Receiver. Owner s Manual

Instant Ear Thermometer

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Model: Manual DC: WIRELESS COLOR FORECAST STATION

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL

15 Digital Photo Frame Instructional Manual

CA-125 Owner's Manual

8 Digital Photo Frame Instructional Manual

PK5500 v1.1 Installation Instructions

ER102. Emergency Crank Weather Radio Owner s Manual.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Laser Wireless Rechargeable Mouse. User s Manual

Wahl C50 Calibrator FEATURES

User Guide. 4 wire Earth Resistance Tester Model GRT300

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Instant Ear Thermometer

LCD5500Z / PKP-LCD v3.x Installation Instructions

Hand-held thermometer Model CTH7000

Wireless Data Logger Monitoring Systems

NortechCommander Software Operating Manual MAN R6

Infrared Viewers. Manual

2GB MP3 Player USER GUIDE

Weather Radio Alarm Clock

Atomic Alarm Clock model 13131W2

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

TABLE OF CONTENTS INTRODUCTION 2 PACKAGE CONTENTS. 3 TECHNICAL REQUIREMENTS... 3 PRODUCT SUPPORT... 3 SPECIFICATIONS 4 INSTALLATION GUIDE...

TC-9102 Series Surface Mount Temperature Controllers

Thermocouple Thermometer Models

Tympanic Thermometer

USB-500/600 Series Low-Cost Data Loggers and Accessories

GX-2009 Data Logger Management Program Operator s Manual

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Multi Media Cable Tester TM-901N/TM-902/TM-903

Transcription:

User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42570

Introduction Congratulations on your purchase of the Model 42570 IR Thermometer. This Infrared thermometer measures and displays non-contact temperature readings up to 3992 F/2200 C (certified to 2000 F/1100 C) and also Type K thermocouple readings to 1370 C (2498 F). At 50, built-in dual lasers converge to 1 target spot to insure accurate targeting and temperature measurement. Advanced features include a USB PC interface and software, 100ms response time, Max/Min/Ave/Diff displays adjustable emissivity and High/Low alarms. Proper use and care of this meter will provide years of reliable service. Warranty EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for three years from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com (click on Contact Extech and go to Service Department to request an RA number). A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Safety Use extreme caution when the laser pointer is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas 2

Meter Description 1. IR sensor and Laser Pointers 2. LCD Display 3. Down Button 4. Measurement Trigger 5. Mode Button 6. Battery compartment 7. Backlight/Laser Button 8. Up Button 9. Type K thermocouple input (side) 9 10 8 7 3 4 5 6 2 1 10. USB port (side) DISPLAY 1. SCAN, measurement in progress 2. Bargraph 3. Laser pointer active 4. Power locked ON 5. HOLD, last measurement locked in display 6. Max/Min temperature display or memory location display 7. Main temperature display 8. High/ Low limit alarm 9. USB connection 10. Battery status 11. Emissivity or Type K or Stored value display 12. Thermocouple probe installed 13. Emissivity setting 14. Logged memory 3

Operating Instructions IR Temperature Measurements 1. Hold the meter by its handle and point it toward the surface to be measured. 2. Pull and hold the trigger to turn the meter on and begin testing. SCAN and the temperature reading will appear on the large display. The upper and lower sub-displays will indicate values/settings previously used. 3. Release the Trigger and the reading will hold for approximately 7 seconds ( HOLD will appear on the LCD) after which the meter will automatically shut off. The only exception to this is if the LOCK mode is set to ON. The MODE button options With the trigger pulled (SCAN displayed), Press the MODE button to view and scroll through: MAX : Maximum value measured MIN: Minimum value measured DIF: Difference between the Max and Min values AVG: Average of the measured values LOG: A memory location is displayed in the small upper display and the value in that location is displayed in the small lower display. Press the or buttons to scroll through the locations. TK: With a Type K thermocouple probe connected to the meter, the probe temperature is displayed in the small lower display. With the trigger released (HOLD displayed), Press the MODE button to scroll through and access the following. The selected item is indicated by a blinking icon. Recorded data: (Press the or button to scroll through and view) MAX MIN DIF AVG LOG ε = Emissivity (blinking ε=). Press the or button to set the value. Lock mode. Press the or buttons to select ON or OFF. High alarm ON or OFF (blinking H). Press the or button to select. High alarm value adjustment (blinking H and set the value. ). Press the or button to Low alarm ON or OFF (blinking L). Press the or button to select. Low alarm value adjustment (blinking L and set the value. C or F Temperature units. Press the or button to select. ). Press the or button to 4

Dual Laser Pointer and Backlight Button The dual laser pointers are designed to cross at a distance of 50 (76cm). The spot size at this distance is a 1 diameter and this is the recommended distance to target for most measurements. To turn the lasers on/off: 1. Press and Hold the Trigger 2. While SCAN is on the display, press and release the backlight/laser button ( ). Either the backlight or laser pointers will change status (On/Off). Repeat this until the desired conditions are set. The laser icon will appear in the LCD when the laser function is enabled. 3. The status of the functions will be stored in memory and will remain as the default turn-on condition until changed. High and Low Alarm Feature When either programmed alarm (high or low) point is reached the meter will alert the user via an audible beep and a blinking LCD display icon. The alarm limit is set and the feature is enabled/disabled using the MODE button. The setting is stored and memory and will remain as the turn-on condition until changed. Temperature Units The temperature units can be set to F or C. The selection is made using the MODE button. Lock feature The LOCK feature disables the Auto Power Off feature for the period of use when selected. The feature is useful for long term temperature monitoring and hands free use. The meter will revert to auto power off if the trigger is pressed during a locked scan. The selection is made using the MODE button. Over-range Indication If the temperature measurement exceeds the specified temperature range, the thermometer will display dashes in place of a temperature reading. USB Function The supplied software and cable are used to transmitt the IR and Type K measurement data to a PC via USB. To Turn-on or Shut-off the USB function: 1. With MAX, MIN, DIF, or AVG displayed, press the LIGHT/LASER button until USB sign appears in the right lower corner of the LCD. USB is active. 2. Press the LIGHT/LASER button again until USB disappears. The USB function is off. Refer to the help file in the software for operational details. 5

Battery Replacement When the low battery symbol appears on the display, replace the meter s battery (9V). The battery compartment is located behind the panel that surrounds the meter s trigger. Open the compartment by pressing the release button (1) and then pulling the panel (2) down from the trigger area. Replace the 9V battery and close the battery compartment cover. 1 2 Data Logger Storing Data: The thermometer is capable of storing up to 100 data points. Infrared: To store data from an infrared reading, 1. Pull and Hold the trigger 2. Press the MODE button until LOG appears in the lower left corner of the display; a log location number will be displayed. If no temperature has been recorded in the displayed LOG location, 4 dashes will appear in the lower right corner. 3. Aim the unit at the target area you want to record, and press the laser/backlight button. The recorded temperature will appear in the lower right corner. 4. To select another log location, press the up and down keys. Recalling Data: To recall stored data after the unit shuts off, 1. Press the MODE button until LOG appears in the lower left corner. A LOG location number will be shown below LOG, and the stored temperature for that location will be display. 2. To move to another LOG location, press the UP and Down keys. Log Clear Function: To clear the memory, The Log clear function allows you to quickly clear all logged data points. This function can only be used when the unit is in the LOG mode. 1. While in LOG mode, press the trigger, and then press the down arrow button until LOG location 0 is displayed. Note: This can only be done when the trigger is pulled. LOG location 0 cannot be accessed, by using the up arrow button. 2. When LOG location 0 shows in the display, press and release the laser/backlight button, then press and release the up arrow key. A tone will sound, and the LOG location will automatically change to 1, signifying that all data locations have been cleared. 6

IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adjust to the temperature of the surface it is covering. 4. Measurements through transparent surfaces such as glass will not be accurate. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter automatically compensates for deviations in ambient temperature. However, it can take up to 30 minutes for the meter to adjust to extremely wide changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down or side to side motion) until the hot spot is located. Field of View The meter s field of view is 50:1. For example, if the meter is 50 inches from the target (spot), the diameter of the target must be greater than 1 inch. Other distances are shown in the field of view diagram. Measurements should normally be made as close as possible to the 1 spot distance. The meter can measure from longer distances, but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. @300cm 5cm @100 2 @150cm 2.5cm @50 1 @75cm 1.25cm @25 0.5 7

Specifications InfraRed Thermometer Range -58 to 3992 o F (-50 to 2200 o C)(typical spec only >1832 o F/1000 o C) Resolution 0.1 o < 1000 o, 1 o 1000 o Accuracy -58 F to -10 F(-50 C to -23 C) ±14 F/7 C (Typical) -10 F to 28 F(-23 C to -2 C) ±8 F/4 C 28 F to 200 F (-2 C to 94 C) ±4.5 F/2.5 C 200 F to 400 F (94 C to 204 C) ±(1.0%rdg + 2 F/1 C) 400 F to 800 F (204 C to 426 C) ±(1.5%rdg + 2 F/1 C) 800 F to 1832 F (426 C to 1000 C) ±(3%rdg +2 F/1 C) 1832 to 3992 F (1000 C to 2200 C) ±(5%rdg +4 F/2 C)(typical only) Note: Accuracy is specified for the following ambient temperature range: 73 to 77 F (23 to 25 C) Emissivity 0.10 to 1.00 adjustable Field of View Laser pointer IR Spectral response Repeatability D/S = Approx. 50:1 ratio (D = distance; S = spot or target) Dual, Class 2 laser < 1mW power; Wavelength is 630 to 670nm 8 to 14 μm (wavelength) ± 0.5% of reading or ± 1.8 o F (1 o C) whichever is greater Thermocouple Thermometer (Type K) Range Resolution Accuracy -50 to 1370 C(-58 F to 2498 F) 0.1 C(0.1 F)<1000, 1 C(1 F)>1000-50 to 1000 C (-58 to 1832 F): ± 1.5% of reading + 3 C (±5 F) 1000 to 1370 C (1832 F to 2498 F): ± 1.5% of reading + 2 C (±3.6 F) General Specifications Display Backlit LCD display with function indicators Response time 100ms Over range indication --------- Operating Temperature 32 o F to 122 o F (0 o C to 50 o C) Operating Humidity 10% to 90%RH operating, <80%RH storage. Storage Temperature 14 to 140 o F (-10 to 60 o C) Power Supply 9V battery Automatic Power Off 7 seconds, with LOCK to disable Weight 11.3 oz. / 320g Dimensions 8 x 6.1 x 2 (204 x 155 x 52mm) Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. 8

Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2009 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 9