Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

Similar documents
digital fever alert ear thermometer suitable from birth instruction manual

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

Instant Ear Thermometer

Instant Ear Thermometer

RT-1261A Ear and Forehead Thermometer Owner s Manual

Tympanic Thermometer

Touchless Forehead Thermometer

CareTemp Touch Free Thermometer. Directions for use

Hygro-Thermometer + InfraRed Thermometer Model RH101

Suggested BiliChek Usage Protocol

How To Use A Thermometer

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

EXERGEN. English. TemporalScanner TM. Accurate Temperature with a Gentle Forehead Scan. Operators Manual for TAT-5000

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Forehead Thermometer INSTRUCTION MANUAL. Model MC-720

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Dual Laser InfraRed (IR) Thermometer with Color Alert

e I N S T RUC TION M ANU A L

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

ExStik TM ph Waterproof Meters

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

User's Guide. Pinless Moisture Meter. Model MO257

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

body fat scale + Instruction Manual complete body analysis scale HEALTH

Thermistor Thermometer MODEL NO

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

el-720 Carbon Dioxide Gas Leak Detector User s Guide

4-Channel Thermometer / Datalogger

Wireless Indoor/ Outdoor Thermometer

Wolverine Data PASS Portable Scanner User Manual V1.0

Instruction Manual Temp 4/5/6 Temperature Meter Series

IN-OUT Thermometer with Cable Free Sensor and Clock

User Guide FOR FACE AND BODY SONIC SKIN CLEANSING. Become a Clarisonic Preferred Customer. Four Speeds + Body Setting. Three-Year Warranty

Digital Photo Picture Frame. Operation Manual

Important Things to Know

Mini InfraRed Thermometer with Laser Pointer

Light Meter (Foot Candles)

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

Refer to page 6 to page 19 for detailed instructions.

62 Max/62 Max + Infrared Thermometer

User Guide. Body fat scale

Temperature Humidity Meter

Ultrasonic Distance Meter. Operation Manual

Thermocouple Thermometer Models

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

Digital Wireless Rain Gauge & Thermometer

How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)

Contents Contents Contents Overview Charging your headset Wearing the headset Powering on the headset Connecting your headset for dictation

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Body Fat Scale Instructions for use

Wolverine 35mm Film to Digital Converter. Model F2D USER MANUAL

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

BASIC BODY COMPOSITION SCALE

Microwave Meter. Instruction Manual

ramon 2.2 Radon Monitor manual

Ground Resistance Clamp On Tester

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Part # rev 1. American Diagnostic Corporation 55 Commerce Drive, Hauppauge, New York

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

ST815 Illumination Sensor with LCD

Owner s Manual

Weather Radio Alarm Clock

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen

UNIVERSAL BLUETOOTH KEYBOARD CASE FOR TABLETS 7-8 INCHES

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Hardware Guide for the Classic and Elite CR Systems PN 9G9637 Version 1.0

EzFlex Combustible Gas Leak Detector Model EZ40

Introduction. What does PICO do? How does PICO work?

Leica DISTO TM D210 The original laser distance meter

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

CarePartner Telephone With Reminders

Automatic Wrist Blood Pressure Monitor with

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Wireless Alarm System. Silent Alert. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

TABLE OF CONTENTS 11.0 WARRANTY

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

Instructions for use.

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

NFC Communication Tray Model: HHX-IT3-Z

CO-220 Carbon Monoxide Meter

The OmniPod Insulin Management System

Integrating Sound Level Meter and Datalogger

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

MEMO ALARM CLOCK Operating Manual

Bottom Loading Water Dispenser

Mold Alert... Operation Manual P0270

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

HEART RATE + CALORIE MONITOR

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

INSTRUCTIONS FOR USE. Read this information before you start. Important things to know about your SmartJect autoinjector. Important things to remember

RF Projection Barometer With Remote Thermo Sensor

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

Transcription:

Forehead Thermometer Use and Care Manual IMPORTANT! READ AND SAVE THESE INSTRUCTIONS Model V977 Questions or Comments Call toll-free: 1-800-477-0457 or E-mail: consumerrelations@kaz.com www.kaz.com

QUICK START GUIDE for Forehead Thermometer Model V977 First time Use: Pull plastic strip under battery cover. Remove 98.6 F label from display. 1 2 Turn On Remove protective scanner cap. Scan Press and release power button. Move hair away from forehead and place scanner in the center of the forehead. Press and release power button and scan forehead slowly from the center of the forehead to the temple - wait for confirmation beep. Wait for beep and flashing F. 3 Repeat Repeat measurement if necessary - wait for flashing F and repeat step 2. PLEASE NOTE: The unit reads an oral equivalent temperature. Add 1 F to get a rectal equivalent. Take 3 measurements if readings appear low.

Some Helpful Guidelines For Best Results When Using the Forehead Thermometer Call your doctor when your child has diarrhea, vomiting or changes in appetite, lethargy (sluggishness) or is unusually sleepy. It is important to know each individual s Normal temperature when they are well. This is the only way to accurately diagnose a fever. Take multiple readings when healthy to determine Normal temperature. A child s normal temperature can be as high as 99.9 F or as low as 97.0 F. Re-measure with a standard digital thermometer for confirmation, especially on infants (It is recommended use a digital thermometer rectally on infants and on sleeping infants if there is a question about the measurement. Be sure to note this unit reads 1 F lower than a rectal digital measurement).

Forehead Thermometer Instruction Manual Thank you for purchasing the Vicks Forehead Thermometer (V977). The Forehead Thermometer is a high quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, the Forehead Thermometer can provide a stable, heat-interference-free reading with each measurement. The instrument performs a self-test every time it is switched on to always guarantee the accuracy of measurements. The Forehead Thermometer is intended for the monitoring of human body temperature in the home. It is intended for use on people of all ages. Please read these instructions carefully before using this instrument and keep the instructions and the thermometer in a safe place. Table of Contents 1. The Advantages of your Forehead Thermometer 2. Important Safety Instructions 3. Product Description 4. How the Forehead Thermometer Measures Body Temperature 5. Control Displays and Symbols 6. Directions for Use 7. Error Messages 8. How to recall 12 readings in the memory mode 9. Cleaning and Storage 10. Replacing the Battery 11. Warranty 12. Technical Specifications 1. The Advantages of your Forehead Thermometer Measurement in 3 seconds The innovative infrared technology allows measurement of forehead temperature in only 3 seconds. Accurate and reliable Due to the unique probe assembly construction, the advanced infrared sensor, and the complete calibration process this unit can offer a very accurate and reliable temperature measurement comparable to one taken from the oral site with a regular digital thermometer.

Gentle and Easy to Use The Forehead Thermometer is non-invasive. A measurement can be taken even while a child is sleeping. Design is easy to hold and use. The Forehead Thermometer is less threatening to a child than a rectal thermometer and easier to use than other methods. Auto-Display Memory The last reading is automatically displayed for 3 seconds when the unit is switched ON. Multiple Reading Recalls Users can recall the last 12 readings when entering the MemoryTracker recall mode, enabling efficient tracking of temperature history and variations. Safe and Hygienic No risk of broken glass or mercury ingestion. Completely safe for use on children. Fever InSight Feature Fever InSight helps you to better understand the meaning of your child s temperature with the colour indicated on the display. The screen displays Green if no fever, Yellow when the temperature is slightly elevated and a Red alert for fever. 10 audible beeps indicate temperatures + 99.5 F alert that the patient may have a fever. Color Range ( F) Meaning Green 97.0-99.5 Acceptable Yellow 99.6-100.8 Elevated Red 100.9+ Possible High Fever 詐 2. Important Safety Instructions Never use the thermometer for purposes other than those it has been intended for. Please follow the general safety precautions when using on children. Never immerse the Forehead Thermometer into water or other liquids (not waterproof). For cleaning and disinfecting please follow the instructions in the Cleaning and Storage section. Keep the instrument away from direct exposure to the sun and keep it in a dust-free, dry area at the temperature between 60.8-104 F. Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself. If damaged, do not attempt to repair the instrument! Please contact our Consumer Relations Department at: 1-800-477-0457.

This Forehead Thermometer consists of high-quality precision parts. Do not drop the instrument. Protect it from severe impact and shock. Do not twist the instrument or the measuring sensor. WARNING: Use of this Forehead Thermometer is not intended as a substitute for consultation with your physician or pediatrician. Thermometer is not waterproof! Please NEVER immerse into liquids! 3. Product Description (1) Power Button (2) Scanner (3) LCD Display (4) Memory Button (1) (3) (4) (2) (6) (5) Battery Cover (5) (6) Protective Scanner Cap 4. How the Forehead Thermometer Measures Body Temperature The Forehead Thermometer measures infrared energy radiated from the skin above of the eyebrow area and the surrounding tissue. This energy is collected through the lens and converted to a temperature value. Temperature readings obtained by scanning above the eyebrow area will provide the greatest accuracy. The Forehead Thermometer has been clinically tested and proven to be safe and accurate when used in accordance with its operating instruction manual.

5. Control Displays and Symbols LCD Display Display Meaning Description Self check ensures proper functioning Press the On/Off button to run on the unit, all segments will be shown for 2 seconds. Recall of last reading Ready to measure Measurement complete Low battery indication The last reading will be shown on the display automatically for 3 seconds. The unit is ready for the measurement, the F icon will keep flashing. The reading will be shown on the LCD display with the F icon flashing, the unit is ready again for the next measurement. When the unit is turned on, the battery icon will keep flashing to remind the user to replace the batteries.

6. Directions for Use 1. Press the Power button on front of unit. The LCD is activated to show all segments for 2 seconds. 2. The last measurement reading will be shown on the display automatically for 3 seconds with the «M» icon. 3. When the F icon is flashing, a beep sound is heard and the thermometer is ready for the measurement. 4. Place the probe gently and flush onto the area approximately 1/2 inch above the center of the eyebrow. If the eyebrow area is covered with hair, sweat or dirt, please clean the area beforehand to improve the reading accuracy. (1) (2) (3) (4) 5. Press the Power button once and release it. Start to move the instrument steadily from 1/2 inch above the center of the eyebrow to 1/2 inch above the tail of the eyebrow area and back up again. A long beep will sound after 3 seconds to signal measurement complete. If the probe movement is too slow to reach the tail of the eyebrow before the long beep sound is heard, repeat the measurement as above from step 4, and move the probe a little quicker this time. 6. Read the recorded temperature from the LCD display. (5) (6) To avoid an inaccurate measurement, note the following: Patients should stay in steady - state room condition for at least 30 minutes. Don t remove the measurement device from the measuring area before hearing the final beep. Don t take a measurement while or immediately after nursing a baby. Don t use the forehead thermometer in high humidity environments. Patients should not drink, eat, or be physically active before/while taking the measurement. Before placing the thermometer sensor onto the measurement area, remove dirt, hair, or sweat. Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Always take the temperature in the same location, since the temperature readings may vary from different locations.

In the following situations it is recommended that three temperatures in the same location be taken and the highest one taken as the reading: 1) Newborn infants in the first 100 days. 2) Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical. 3) When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings. 7. Error Messages Display / Problem Display Meaning Possible cause and remedy Measured temperature too high CAUTION: High fever requires immediate medical attention! Measured temperature too low Displays «H» when measured temperature higher than 108.0 F. Displays «L» when measured temperature lower than 93.2 F. Room temperature too high Room temperature too low Error function display Displays «H» in conjunction with the «s» when room temperature is higher than 104.0 F. Displays «L» in conjunction with the «t» when room temperature is lower than 60.8 F. When system has a malfunction. Blank display Dead battery indication Please check if the battery has been loaded correctly. Also check polarity (<+> and < >) of batteries. If the steady battery icon is the only symbol shown on the display, the battery should be replaced immediately.

8. MemoryTracker Mode Use the following steps to recall the last 12 temperature measurements. Display Display Meaning Description Recall Mode Press the M button to enter Recall Mode when power is off. The memory icon «M» flashes. Reading 1 (the last reading) Reading 2 (the second latest reading) Reading 12 (the last reading) Press and release the M button to recall the last reading. The number 1 will appear showing the last saved reading. Press and release the M button to recall the second latest reading. Press and release the M button consecutively to recall readings in succession, up to the last 12 readings. Pressing and releasing the Power button after the last 12 readings have been recalled will resume the above sequence from reading 1. 9. Cleaning and Storage Use an alcohol swab or cotton swab moistened with alcohol (70% Isopropyl) to clean the thermometer casing and the measuring probe. Ensure that no liquid enters the interior of the thermometer. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids. Take care not to scratch the surface of the LCD by replacing the protective cap after use. 10

10. Replacing the Battery The Forehead Thermometer is supplied with 2 AAA batteries. Replace with 2 new AAA batteries when the flashing battery symbol appears on the LCD display. To change the batteries, slide open the battery cover as shown and remove batteries. Replace the batteries being sure to align properly as indicated inside the battery compartment. Remove the battery from the instrument if it is not required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery. Dispose of batteries according to local waste management directions. 11. Warranty Your Forehead Thermometer is durable and manufactured for normal, household use. Following directions carefully will ensure years of dependable operation. If for any reason (other than misuse or normal battery replacement) you are dissatisfied with your Forehead Thermometer, we will repair or replace it, at our option, free during the three year warranty period. Modification to the product by the consumer is not authorized and voids the warranty. If the thermometer does not function properly, first check the battery. Replace if necessary. If repair is necessary call our Consumer Relations Department at 1-800-477-0457 or write to Kaz Incorporated, Consumer Relations Department, 250 Turnpike Road, Southborough, MA 01772 USA, or e-mail consumerrelations@kaz.com, explaining just how the thermometer is improperly working. Our consumer service representative will provide further instruction on how to correct the trouble yourself or will ask you to return the thermometer for repair or replacement. 11

12. Technical Specifications Type: Measuring Range: Resolution: Accuracy: Display: Forehead Thermometer V977 Forehead measuring range: 93.2 F to 108.0 F. 0.1 F Laboratory: ±0.4 F, 96.8 ~ 102.2 F (Ambient Temperature: 60.8 F to 104 F) Liquid Crystal Display, 4 digits plus special icons Acoustic: a. The unit is turned ON and ready for the measurement: 1 short «beep» sound. b. Complete the measurement: 1 long beep sound. c. System error or malfunction: 3 short «beep» sounds. Memory: Backlight Operating temperature: 60.8 F to 104 F Storage/transport temperature: Automatic Switch-off: Battery: Weight: Standards: a. Auto-Display the last measured temperature when switched on. b. 12 readings recall in the Memory Mode. a. The display will be lighted for 4 seconds when the unit is turned ON. b. The display will be lighted again for 5 seconds when the measurement has been completed. -4 F to 122 F Approx. 1 minute after last measurement has been taken (2) AAA Batteries - at least 1000 measurements 3.51oz. (with battery), 2.72oz. (w/o battery) Complies with ASTM E-1965-98 requirements k Manufacturing Quality Healthcare Products for Over 75 Years Kaz, Incorporated Hudson, NY 12534 www.kaz.com This product is manufactured by Kaz, Inc. under a license to the Vicks trademark. Vicks is a registered trademark of The Procter & Gamble Company, Cincinnati, Ohio, USA 2008 KAZ, Incorporated Made and printed in China P/N: 31IM0977190 12