Mini InfraRed Thermometer with Laser Pointer

Similar documents
Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Dual Laser InfraRed (IR) Thermometer

High Temperature InfraRed Thermometer with Laser Pointer

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

Hygro-Thermometer + InfraRed Thermometer Model RH101

OPERATION MANUAL INFRARED THERMOMETER

User's Guide. Pinless Moisture Meter. Model MO257

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Owner s Manual

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Temperature and Humidity Datalogger. Model 42280

User's Guide. Digital Sound Level Meter. Model

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

USER GUIDE. LED Light Meter. Model LT45

4-Channel Thermometer / Datalogger

Available Options The IR-750B, IR-750EXB, IR-16 and IR-16EX series heat tracers are available with the options listed below.

Ultrasonic Distance Meter. Operation Manual

62 Max/62 Max + Infrared Thermometer

Pocket Tach 99 (PT99) Non-Contact Tachometer

User Guide. 4 wire Earth Resistance Tester Model GRT300

TABLE OF CONTENTS 11.0 WARRANTY

Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding Руководство пользователя

SURFACE MOUNT LED LAMP STANDARD BRIGHT 0606

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

DSM155 Digital LED Light Meter User s Manual DSM155

Ground Resistance Clamp On Tester

Phoenix Body Fat Scale Manual

Touchless Forehead Thermometer

Integrating Sound Level Meter and Datalogger

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User Manual. Humidity-Temperature Chart Recorder. Model RH520

12 Volt 30 Amp Digital Solar Charge Controller

ExStik TM ph Waterproof Meters

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Professional Thermohygrometer

Infrared Viewers. Manual

Technical Data FLIR E40bx (incl. Wi-Fi)

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

RS DIGITAL THERMOMETER

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

AMCON DIGITAL PD METER USER S MANUAL EQ Fax

UT202A Operating Manual. Contents

EzFlex Combustible Gas Leak Detector Model EZ40

Dome Camera with IR Night Vision

0.28" Quadruple Digit Numeric Displays. Technical Data Sheet. Model No.: KW4-281XSB

Infrared Thermometer Calibration A Complete Guide

Temperature Humidity Meter

Laser Alignment Using the CSI 2140

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

Wireless Indoor/ Outdoor Thermometer

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

e I N S T RUC TION M ANU A L

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

High Performance Visible Laser Diode Scanners

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101

Multi Media Cable Tester TM-901N/TM-902/TM-903

Solar Controller / Battery Charger User s Manual

Online Infrared Flue Gas Analyzer Gasboard 3000

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Microwave Meter. Instruction Manual

Alignment Laser System.

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

Product Specification

Features: Mounting the Optic

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Light Meter (Foot Candles)

Duct Humidity Transmitter

RT-1261A Ear and Forehead Thermometer Owner s Manual

How To Use A Meter

Pad. Quick Start Guide

Portable digital microprocessor thermometers with interchangeable probes

Melting Point Apparatus

TENSIONMETER ** code 183_LNRSTW **

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

AutoRanging Digital MultiMeter

Long Distance Industrial Wireless Transmitters and Receivers

Thermistor Thermometer MODEL NO

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001

digital fever alert ear thermometer suitable from birth instruction manual

Leica DISTO TM D210 The original laser distance meter

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

0.45mm Height 0402 Package Pure Green Chip LED Technical Data Sheet. Part No.: LL-S160PGC-G5-1B

User's Guide. True RMS Industrial Multimeter

3.0mm (1.2") 8 8 Hyper Red Dot Matrix LED Displays Technical Data Sheet. Model No.: KWM-30881XVB

Transcription:

User s Manual Mini InfraRed Thermometer with Laser Pointer MODEL 42500

Introduction Congratulations on your purchase of the Model 42500 IR Thermometer. This thermometer makes non-contact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlit LCD and handy pushbuttons combine for convenient, ergonomic operation. Proper use and care of this meter will provide years of reliable service. Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas Meter Description 1. LCD Display 2. Function Buttons 3. Handle Grip 4. IR Sensor 5. Laser pointer beam 6. Measurement Trigger 7. Battery Compartment 1 2 3 4 5 6 7 2

Operating Instructions 1. Hold the meter by its Handle Grip and point it toward the surface to be measured. Read the Field of View section below for information on distance to target ratios. 2. Pull and hold the orange Trigger to turn the meter on and begin testing. The display will light if the battery is good. Replace the battery if the display does not light. 3. While continuing to pull the Trigger: a. Push the Laser button to turn on the laser pointer. When the laser is on, the laser icon will appear on the LCD over the temperature reading. Aim the red beam approximately a half inch below the point of test (pressing the Laser button again turns the laser off). b. Select the temperature units using the o C / o F button. c. Push the backlight button to turn on the LCD backlighting function. 4. Release the Trigger and the reading will hold for approximately 6 seconds and then the meter will automatically shut off. 5. The meter defaults to the programmed conditions in use when the meter was last turned off. For example, if the laser is set to ON and the temperature units are set to o F at the time the unit is turned off, the unit will turn on employing the same settings. Over-range Indicator If the temperature measurement exceeds 500 F (260 C), the thermometer will display dashes in place of a temperature reading. Field of View The meter s field of view is 6:1. For example, if the meter is 12 inches from the target (spot), the diameter of the target must be at least 2 inches. Other distances are shown below in the field of view diagram. Note that measurements should normally be made less than 2 feet from the target. The meter can measure from further distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 3 0.5 6 Diameter of Spot 2 1 12 24 4 Sensor Beam 0.63 Laser Beam Distance to Object 3

Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram. 2. If the surface of the object under test is covered with frost, oil, grime, etc., clean before taking measurements. 3. If an object's surface is highly reflective apply masking tape or flat black paint to the surface before measuring. 4. The meter may not make accurate measurements through transparent surfaces such as glass. 5. Steam, dust, smoke, etc. can obscure accurate measurements. 6. The meter compensates for deviations in ambient temperature. It can, however, take up to 30 minutes for the meter to adjust to extremely wide ambient temperature changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down motion) until the hot spot is located. Battery Replacement When the low battery symbol appears on the LCD, replace the meter s 9V battery. The battery compartment is located on the bottom of the meter's handle. Open the compartment by sliding the battery compartment cover off in the direction of the arrow. Replace battery and re-install the battery compartment cover. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle 4

Specifications Infrared Thermometer Specifications Range / Resolution -20 to 260 o C (-4 to 500 o F) 1 o C/F Accuracy ± 2% of reading or ±2 o C (4 o F) whichever is greater, from 15 to 50 o C (60 to 113 o F) ± 3% of reading or ±3 o C (6 o F) whichever is greater, for remainder of range: -20 to 260 o C (-4 to 500 o F) Note: Accuracy is specified for the following ambient temperature range: 18 to 28 C (64 to 82 F) Emissivity 0.95 fixed value Field of View D/S = Approx. 6:1 ratio (D = distance, S = spot) Laser power Less than 1mW Spectral response 6 to 14 μm (wavelength) General Specifications Display Display rate Operating Temperature Operating Humidity Power Supply Automatic Power Off Weight 2000 count, backlit LCD display with function indicators 1 second approx. 0 C to 50 C (32 F to 122 F) Max. 80% RH 9V battery Meter shuts off automatically after 6 seconds 140g /4.9 oz. Dimensions 170 x 44 x 40mm (6.7 x 1.7 x 1.6 ) Copyright 2010 Extech Instruments Corporation (a FLIR company). All rights reserved including the right of reproduction in whole or in part in any form. 5