Hydrogen Peroxide Safety & Handling"

Similar documents
Product Bulletin INTEROX HYDROGEN PEROXIDE

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

Metal Rescue Rust Remover Technical Data

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

Inline Chlorinator Chlorine Chemical Feeder

Mechanical Systems Competency 1.20

MATERIAL SAFETY DATA SHEET In accordance with CE Regulation n 1907/2006. Annex II.

NITROUS TRANSFER PUMP INSTRUCTIONS

MATERIAL SAFETY DATA SHEET "LIQUID FIRE" DRAIN LINE OPENER 09/2007 PHYSICAL/CHEMICAL CHARACTERISTICS:

Indiana Department of Environmental Management. Well Disinfection

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Magnesium Carbonate, Lite, Powder USP

MATERIAL SAFETY DATA SHEET TOILET BOWL SANITIZER

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

Material Safety Data Sheet

MSDS Report Report in electronic version is only for client's preview and reference. For confirmative content, formal test report shall prevail.

PBM has solutions for your valve application.

MATERIAL SAFETY DATA SHEET REVISION DATE: 02/01/2005

Water System Disinfection

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Trade Name of this Product Isopropyl Rubbing Alcohol 91% USP. Corporate Compliance Team 1666 East Touhy Avenue

ph Measurement and Control

Issue Date: 04-Oct-2013 Revision Date: 19-Nov-2014 Version Number: Identification. 2. Hazards Identification

SECTION 2: HAZARDS IDENTIFICATION OSHA/HCS Status: This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR ).

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Atomic Structure. Atoms consist of: Nucleus: Electrons Atom is electrically balanced equal electrons and protons. Protons Neutrons

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

EMERGENCY SHOWERS AND EYEWASH STATIONS

Food Protection Services

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER

1. Chemical Product and Company Identification. 2. Hazardous Ingredients

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Float and Thermostatic Traps Series H, C and X

Creation Date: Revision Date: Page: 1 of 7

SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING SULPHURIC ACID DRAIN CLEANER

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

MATERIAL SAFETY DATA SHEET SECTION 1 CHEMICAL PRODUCT AND COMPANY INFORMATION SECTION 2 COMPOSITION/INFORMATION ON INGREDIENTS

Lecture 30: Cleanroom design and contamination control

EXTRACTION OF METALS

MATERIAL SAFETY DATA SHEET

Pressure Vessels (Air Compressors) and LPG Tanks

SAFETY DATA SHEET. 955 Connecticut Ave, Suite 5202 Bridgeport, CT Tel: Date Prepared: July 22, 2015

(616) Ann Street N.W. Emergency Phone Grand Rapids, MI 49504

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

GPS Safety Summary. Hydrogen peroxide

OXYCIDE DAILY DISINFECTANT CLEANER. Use only for the purpose on the product label.

According to the criteria of NOHSC, this material is classified as; Hazardous Substance, Dangerous Goods

EG-SAFETY DATA SHEET (91/155/EWG)

Spartan Chemical Company, Inc. Material Safety Data Sheet

Material Safety Data Sheet

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

Operator Quick Guide EC SENSOR

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP) - Europe. Bona Wood Floor Cleaner

Emergency Showers and Eyewash Stations

Chemical Reducing Solution CRS

MATERIAL SAFETY DATA SHEET (MSDS)/SAFETY DATA SHEET (SDS)

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

Select Radiators Installation Guide

SAFETY DATA SHEET INSTANT HAND SANITIZER GEL / SANTI-GEL

HYDROGEN PEROXIDE SOLUTION 3%

A Guide to Trouble-Free Cooling Towers

Material Safety Data Sheet

Watts Pure Water Systems

SOLVENT CLEANER MSDS Page 1 of 5 SAFETY DATA SHEET. (To comply with OSHA s Hazard Communication Standard 29CFR /ANSI z400.

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

Material Safety Data Sheet

SAFETY DATA SHEET. Blue Hand and Body Shampoo

BOOSTER FLUID SOLUTION I. PRODUCT IDENTIFICATION

TECHNICAL DATA SHEET DURO HARD CHROME PLATING PROCESS

REVISION NO : 3 August 2010

EMERGENCY EYEWASH AND SHOWERS 29 CFR Part (c)

Safety, Cleaning, and Chemical Disposal Procedures

1. PRODUCT AND COMPANY IDENTIFICATION

HADEX Food Grade Drinking Water Disinfectant

Emergency Phone Numbers: P.O. Box 1950 CHEMTREC: 800/ Brewster, New York POISON CENTER: 800/ /

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

SAFETY DATA SHEET West Skyhawk Drive West Jordan, UT U.S.A. Phone

COMPOSITION / INFORMATION ON INGREDIENTS

Private Water Supplies Sampling Manual. A Field Guide

MATERIAL SAFETY DATA SHEET

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION 2. HAZARDS IDENTIFICATION. Revised on 10/26/2012 Page 1 of 6

Material Safety Data Sheet

01 - Plastic Pipe Cements and Primers

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Oxidizer(s) Management and Use Guidelines

************************************************************************ *** SECTION 1 PRODUCT IDENTIFICATION

SAFETY DATA SHEET HYDROGEN PEROXIDE 12%

MAGB HEALTH, SAFETY AND ENVIRONMENT GROUP POLLUTION INCIDENT RESPONSE PLAN

Percentage of Water in Popcorn

SAFETY DATA SHEET DALER ROWNEY 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Primer for Acrylic Paint

Ingredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3

BOWIE PUMPS OPERATION - MAINTENANCE

SAFETY DATA SHEET PRIVATE LABEL SULPHURIC ACID DRAIN CLEANER SPD1047/SPD1046

SAFETY DATA SHEET DRAIN CLEANER

MATERIAL SAFETY DATA SHEET

Sodium Sulphite Anhydrous

Confined Space Entry Procedure Worksheet

Transcription:

Hydrogen Peroxide Safety & Handling"

Responsible Care " What are the principles of Responsible Care?! What is the Responsible Care Management System (RCMS)?! Active member of the American Chemistry Council (ACC) and the Chemical Industry Association of Canada (CIAC)! Applying Plan-Do-Check-Act! Committed to constant improvement in:! Occupational Safety and Health! Process Safety! Environmental Protection! Security! Distribution Safety! Product Stewardship Performance! 2!

Hydrogen Peroxide H 2 O 2" Diversified industrial uses! Water-like appearance and physical properties! Oxidizer! Chemically active! Shipped as 70%, 50%, 35%, or 31% but normally stored at 50% or less! 3!

Hydrogen Peroxide Grades" " Current Name Main Uses Specifications Source Dilution Water Comments Standard Waste treatment Non-food bleaching PeroxyChem internal Approved tap water Stannate + other stabilizers Heavily stabilized Technical Chemical synthesis PeroxyChem internal DI water Organic tin free stabilizer Super D Hair bleach, topical uses Specialty laundry bleach U.S. Pharmacopeia for 3% solution DI water Stannate + other stabilizers Heavily stabilized for shelf life Extra stabilizer for stability on dilution to 1-6% SemiConductor Grades Routine semiconductor processing ACS reagent uses Ultra high purity for critical semiconductor use SEMI specifications DI water Lightly stabilized Or non-stabilized 4!

Hydrogen Peroxide Grades" " Current Name Main Uses Specifications Source Dilution Water Comments Durox Durox LRA and LRD U.S. CFR approved food uses in bath, and low residue spray aseptic packaging use Food Chemical Codex DI water Stannate + other Stabilizers Stabilized for food and equipment sanitization OxyPure Potable water treatment NSF approved Food Chemical Codex DI water Lightly Stabilized Propulsion HTP N/A Lightly Stabilized OHP Environmental Fenton s Chemistry DI water Stabilized for Environmental Applications 5!

Sample Applications" Pulp & Paper Bleaching of chemical and mechanical pulps De-inking Textiles Cottons (Stone-washed effect) Bleaching Food and Beverage Aseptic packaging Bacterial disinfecting agent High-fiber additives (bleaching) Electronics Circuit board cleaning & etching Environment Organic pollutant treatment Chlorine, sulfide and cyanide removal Bioremediation Potable water treatment Cleaning and Sanitization Perborates/percarbonates/peracids Liquid H 2 O 2 bleach Detergent manufacturing Polymers and Chemical Synthesis Organic and inorganic peroxides Epoxides/oxides/specialty chemicals Natural Resources Extraction Leaching enhancement for gold and silver extraction Hydraulic fracturing biocide Pharmaceutical and Cosmetic Mouthwash Contact lens cleaner Disinfectant 6!

The 4 Rules of H 2 O 2 Use & Handling" 4 Always Have Water Available Never Confine 1 2 Never Contaminate Never Contact 3 7!

NEVER CONTAMINATE Preventing contamination ensures safety and quality. " 8!

NEVER CONTAMINATE Types of Contamination" Heat & energy! Materials of construction! Externally introduced materials!! 9!

NEVER CONTAMINATE Chemical Reaction Caused by Contamination " H 2 O 2 + Contaminant Oxygen + Water + Heat With fuel present Fire 10!

NEVER CONTAMINATE The Effect of Heat on H 2 O 2" The Effect of Temperature on the Rate of H 2 0 2 Decomposition Rate of Decomposition 0 50 100 150 200 250 Temperature (F ) For every 10 C rise in temperature the decomposition rate approximately doubles.! Temperature (F ) Rate of Decomposition 72 1% per Year 151 1% per Week 218 2% per Day 11!

NEVER CONTAMINATE Materials of Construction" Storage Tanks Piping Valves Pumps Hoses Gaskets, Diaphragms, O-Rings #5254 Aluminum PASSIVATED Consult with PeroxyChem on Application SS316L/SS304L PASSIVATED Standard and Technical Grades only PASSIVATED SS316, SS316L, SS304, SS304L 1060 Aluminum VENTED, PASSIVATED SS316, B356 Aluminum Virgin Teflon Seats and Seals PASSIVATED SS316, B356 Aluminum Mechanical Seals Pure Ceramic, Silicon Carbide, Teflon, SS316 PASSIVATED SS316, SS304 Virgin Teflon, PP363 Vinyl, Garlock Gylon, Viton A Polyethylene LINEAR/CROSS- LINKED HD Consult with PeroxyChem on Application 12!

NEVER CONTAMINATE Reasons for Passivation" Removes surface impurities! Provides a compatible metal oxide surface for Hydrogen Peroxide contact:!! Ensuring stability and quality" Inhibiting corrosion" 13!

NEVER CONTAMINATE Common Materials to Avoid" Brass! Bronze! Chromium! Copper! Graphite! Iron/Steel! Lead! Lubricating Oil! Magnesium Alloys! Monel! Nickel! Pipe Dope! Titanium! Zinc!! These will cause accelerated decomposition of H 2 O 2 14!

NEVER CONTAMINATE How Materials are Introduced Externally" Wrong materials delivered into storage vessel! H 2 O 2 delivered into wrong tank" Process backs up into H 2 O 2 system! Returning unused H 2 O 2 into original container! Dust, dirt, etc.! 15!

NEVER CONTAMINATE Indications of Hydrogen Peroxide Decomposition" Pressure buildup! Activation of pressure relief devices" H 2 O 2 visually active! Rapid bubbling" Temperature increase! Gas or steam evolution! 16!

NEVER CONFINE Pressure buildup can cause tank failure." 17!

NEVER CONFINE Reasons for Not Confining Hydrogen Peroxide" Hydrogen Peroxide always decomposes, only the rate varies! A volume ratio of 200:1 of Oxygen liberated to liquid decomposed is possible! Pressure build up will occur in a closed system! Excess pressure build up can result in tank or line rupture or failure! 18!

NEVER CONFINE Horizontal Tank" H 2 0 2 FILTERED VENT FLOATING RELIEF MANHOLE COVER WATER PROCESS 19!

NEVER CONFINE Vertical Tank" H 2 0 2 FLOATING RELIEF MANHOLE COVER FILTERED VENT WATER DRAIN PROCESS 20!

NEVER CONFINE Pressure Relief in Pipe Between Closed Valves" PRESSURE RELIEF VALVE VALVE H 2 O 2 LINE VALVE 21!

NEVER CONFINE Two Methods of Venting the Ball Cavity of a Valve 1 / 8 DIAMETER HOLE IN UPSTREAM SIDE OF BALL PRESSURE RELIEF VALVE 22!

NEVER CONTACT Serious injury is at stake. " Protect yourself." 23!

NEVER CONTACT Proper Protection" Daily Work Around Equipment! Chemical safety goggles" Rubber gloves" Increased Exposure Due to Spillage, Maintenance or Sampling! Neoprene or vinyl acid suit (cotton clothing can catch fire)" Neoprene boots (leather footwear can catch fire)" Full face shield! Lack of proper eye protection or proper clothing could result in serious injury such as burning of the skin, tissue damage or throat inflammation! 24!

NEVER CONTACT Chemical Reaction Caused by Contact with a Fuel " " H 2 O 2 + Fuel Oxygen + Water + Fire Fuel can be any combustible material such as wood or leather boots 25!

ALWAYS HAVE WATER AVAILABLE A diluted solution is less hazardous." 26!

ALWAYS HAVE WATER AVAILABLE Emergency Response Equipment When Handling H 2 O 2" Always have water available to dilute H 2 O 2! Safety showers! Eyewash! Hose!! 27!

ALWAYS HAVE WATER AVAILABLE First Aid" Eyes Body Internal Immediately flush eyes with plenty of water for at least 15 minutes. Flush skin with water. Remove and wash contaminated clothing and shoes promptly and thoroughly. If swallowed, drink water immediately to dilute. Do not cause vomiting. Call a physician. 28!

ALWAYS HAVE WATER AVAILABLE Response" H 2 O 2 by itself is non-flammable" Use water for extinguishing fires! Keep area clear of all personnel! If a fire is near a storage vessel or equipment cool with an external water spray! Flush equipment with water" 29!

ALWAYS HAVE WATER AVAILABLE General Rules for Maintenance and Repair" Wear proper protective equipment! Rinse off all parts with water (i.e. Relieve pressure on system fittings, nuts, bolts, gaskets)! (shut off H 2 O 2 flow and isolate Repair and clean component! piping, equipment and storage Repassivate if necessary! tank)! Avoid incompatible material or Introduce and flush compatible water through the piping system! equipment substitutions! Check operation! Lock out equipment! Restart" Drain water" 30!

ALWAYS HAVE WATER AVAILABLE Maintain Safety and Quality" PASSIVATION Passivate all components of Hydrogen Peroxide system! INSPECTION Inspect tanks and delivery system once every two years! SAMPLING Test Hydrogen Peroxide and water quality! MAINTENANCE Repair defects immediately Repassivate equipment if needed!! 31!

The 4 Rules of H 2 O 2 Use & Handling" 4 Always Have Water Available Never Confine 1 2 Never Contaminate Never Contact 3 32!

Our Vision" PeroxyChem s vision is to be the leading global supplier of oxidation solutions to the electronics, environmental, food safety and other industrial and consumer markets, built on its peroxygen chemistries and adjacent technologies!! This vision is supported by our core values of safety, people, innovation, customer focus and growth.! People: Increase accountability and personal initiative. Challenge the status quo to improve efficiency and productivity.! Safety: Maintain our historic track record. Prioritize a fierce dedication to safe practices.! Innovation: Innovate in everything we do.! Customer focus: Nurture customer relationships with our expertise and provide innovative ways to meet customer needs.! Growth: Focus on market orientation and continue to serve markets around the world.! 33!

Questions" 34!