Solar and heat recovery hybrid system



Similar documents
Solar Thermal Systems

Hybrid heat pumps. saving energy and reducing carbon emissions

Sea Water Heat Pump Project

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Natural geothermal energy.

Solar Cooling with Concentrators

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

ROTEX gas hybrid heat pump. A strong team.

Thermal Coupling Of Cooling and Heating Systems

How a Ground Source Heat Pump Works for a School or College

Solar Cooling. Methods and Applications. Sargon Ishaya, PE, LEED AP

Building Energy Systems. - HVAC: Heating, Distribution -

Heating & Cooling Efficiency

LG Electronics AE Company, Commercial Air Conditioning

Vitocaldens 222-F Compact Gas-Hybrid appliance

A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING

Daikin Altherma. hybrid heat pump. The natural combination

Rainwater Harvesting

New technical solutions for energy efficient buildings

imagine SOLAR AIR CONDITIONING MADE EASY

The natural ombination

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Summary technical description of the SUNSTORE 4 plant in Marstal

This presentation is posted for public use. ACEEE does not endorse any product or service.

Comparison of Natural Gas, Electricity, & GeoExchange Systems in a Saskatchewan Building Study Performed in Cooperation with Canadian GeoExchange

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

Each icon on this map represents the physical location of a station.

DAikin Altherma low temperature heat pump. end user leaflet

Geothermal Heat Pumps: A Pathway to Zero Net Energy (ZNE) for Schools, Homes and Businesses

Energy Audits. Green Asset Management Presentation

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

All Electrical School

Typical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.

Crowne Plaza Copenhagen Towers The world s greenest hotel

ENERGY EFFICIENCY EXPERTS. MCW's. Environmental Record. Green Design REDUCING OUR CLIENTS' ENVIRONMENTAL FOOTPRINT

In touch with heat pumps for industry and commerce

YOUR GUIDE TO HEAT PUMPS & SOLAR THERMAL

FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation

Daikin Altherma hybrid heat pump. The natural combination

VE : Thermal / Systems Pack. 1. Tabular Room Data editing for thermal properties

Solar Thermal TECHNOLOGY. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu

Residential/Small Commercial Monitoring of Solar Thermal- Geothermal Integrated Systems

Geothermal Heat Pump Systems: From Basics to Hybrids

Sustainable water heating solutions through solar systems

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

Session 2: Hot Water Supply

Mechanical Systems Proposal revised

Drake Landing Solar Community

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Get more from your hot water

Clean Energy Incentive Programs Connecticut Summary. Dave Ljungquist Associate Director, Project Development March 23, 2010

Performance Assessment of a Variable Capacity Air Source Heat Pump and a Horizontal Loop Coupled Ground Source Heat Pump System

GREEN FACTS. Marina Bay Sands

Sustainable Schools Renewable Energy Technologies. Andrew Lyle RD Energy Solutions

Delivering exceptional performance and Ecovalue. Ecocent

Roche Basel/Kaiseraugst

Design of a Heat Pump Assisted Solar Thermal System

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

Industrial Green Building Retrofit 101 Opportunities and Challenges. Light Industrial Green Building Retrofits. Why Green Retrofit?

How To Use A Water Source Heat Pump

The natural ombination

An old boiler can cost you It doesn t stop there A modern solution

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors

Directorate for the Built Environment Building Standards Division

High-efficient gas boiler CompactGas

Our Deep Geothermal Energy Potential: A Case Study in Saskatchewan with Application Throughout the Western Canadian Sedimentary Basin

Information Guide Domestic Air Source Heat Pumps

Zero Energy Building: the first self-sufficient house. Near Zero Energy Building: Same built example. Zero Energy Building: examples

GEOTHERMAL HEATING APPLICATIONS FOR RESIDENTIAL HOMES

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

Laddomat 21. For accumulation when using a wood-fired boiler. Picture 1. The wood-fired boiler is is connected to to. accumulator tank with bypass

The Business Case for Environmental Sustainability

Integrated Solar Radiant Systems

Year project completed or estimated year of completion: October 2014

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

The natural ombination

MISSION HEIGHTS CONDOMINIUMS SOLAR THERMAL HOT WATER HEATING SYSTEM

Ventilation Air conditioning

European Code of Conduct for Data Centre. Presentation of the Awards 2016

Printing and Publishing Energy Savings Guide

Photovoltaics and Solar Thermal Energy in Germany: Market Development, Applications, Industry and Technology

IMMERSION MANAGEMENT SERVICE KG

POLK STATE COLLEGE CHILLER PLANT EVALUATION WINTER HAVEN, FLORIDA APRIL 2, C arastro & A ssociates, C&A# 5747

Multi Drum Heat Storage By John Canivan

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

Application Areas of PV/T (Hybrid) Collectors and Business Trend in the World

SEATTLE STEAM COMPANY FREQUENTLY ASKED QUESTIONS

COMFORT ALL YEAR ROUND HEATING AND COOLING SOLUTIONS FOR YOUR HOME

Ground Source Heat Pumps versus High Efficiency Natural Gas Furnaces in Alberta

Sustainability: Geothermal Energy for Sherman Hospital

Nordic Heat Pump Product Guide

Integrating renewable energy sources and thermal storage

A heat pump system with a latent heat storage utilizing seawater installed in an aquarium

Princeton University Microgrid

Multi-Residential Incentive Summary

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

EUROPEAN COMMISSION. Energy Audits - Cyprus

Congratulations! Your unique solar monitor ID is located on your monitoring unit as seen on this page.

Transcription:

Solar and heat recovery hybrid system

The Listel Hotel is the first hotel in Vancouver to install a cutting-edge renewable energy system. The hotel is reducing its carbon footprint -- and annual energy expenses -- by installing solar panels and a highly efficient heat recovery system. The Listel is now tapping into the sun s abundant and easily-accessible alternative energy via solar thermal collectors to lower their heating costs and, most importantly, their carbon footprint. The hotel expects to reduce its carbon gas emissions by 170 tons annually. Technical details. The Listel s customized system employs equipment typically used as a ground-source heat pump. Such pumps exploit the steady underground temperature to provide seasonal heating and cooling. The Listel s system however does not have an underground loop of liquid-filled tubing for geothermal exchange. Instead, the heat pump is connected to twenty solar collectors and a heat recovery system as well as a 20 ton air-to-water heat pump. According to Roger Huber, owner of Swiss Solar Tech, There is incredible potential for heat recovery, particularly when combined with the solar panels. Huber explains that the waste heat is collected from the cooling system (the air-conditioning chiller) to use as pre-heat for the domestic hot water and as heating support for the building. This enables the existing gas-fired boiler to run less, since the heat pump has a much better co-efficiency rate than a gas boiler. A computer-controlled system from Care System of Vernon BC, combined with a gas-fired boiler, provides heating and cooling of water and air for the 129 room hotel. The solar heat from solar panels on the hotel s roof is primarily used to pre-heat the domestic hot water. Solar-heated water is stored in a tank with a capacity of 4,500 liters. The savings. The estimated pay-back time (amortization period) is less than six years, based on an estimated five per cent annual price increase on natural gas rates. A federal grant from the ecoenergy for Renewable Heat Initiative reduced the cost of the solar part by 25 per cent.

The technical side of the new energy efficient system at the Listel Hotel: The new system, which became operational in February 2008 at the Listel Hotel in Vancouver, employs equipment normally used as a ground-source heat pump, designed to exploit the stable ambient temperature of the earth to provide seasonal heating and cooling. The Listel design, however, doesn t have an underground loop of liquid-filled tubing for geothermal exchange; the heat pump is connected to 20 solar collectors and a highly efficient heat recovery system and a 50 ton air-to-water heat pump. It sounds complicated because it's different but technically it's actually very simple, simple and reliable. That's the beauty of it. There is so much potential for heat recovery, and the combination with the solar is really perfect. We collect the waste heat from the cooling system (air conditioning chiller) to use as pre-heat for the domestic hot water and as heating support for the building in order for the existing gas fired boiler to run less, since the heat pump has a much better co-efficiency rate as a gas boiler. A heat pump has 5 kwh output on 1 kwh of electricity which is also known as the COP rate (co-efficiency rate). The computer-controlled system, still in combination with a gas-fired boiler, provides heating and cooling of water and air for the 125-room hotel. The solar heat from the 20 solar panels on the roof of the hotel is primarily used to heat the domestic hot water with a solar water storage capacity of 4,500 liters for pre-heating. The Listel Hotel is known as Vancouver s most art-full hotel* and one of the city s most well-appointed boutique hotels. Its other green initiatives include composting food wastes and all recyclable materials; reducing use of electricity and water via programs including low-flow toilets and showerheads; a towel and sheet reuse program; providing all amenities in refillable dispensers; and being first hotel in Vancouver to go 100% smoke-free. The hotel s restaurant and bar O Doul s - is in the Green Table Network and Vancouver Aquarium s Ocean Wise program. The Hotel Association of Canada gave The Listel the highest eco-rating of any Vancouver hotel - 4 Green Keys.

20 solar thermal collectors Make: Viessmann Model: Vitosol 100 SV1 Installed: 2008 Purpose: Heats Domestic Hot Water Water, pre-heated by the hotel s solar panels and/or various heat-pumps, is held in the hotel s pre-heated water holding tanks the water is then cycled through this High Efficiency Boiler and then utilized as the hotel s domestic hot water supply.

High Efficiency Boiler Make: CAMUS Microflame series 2 Model: MFNW-1000-E-02 Installed: 2008 Purpose: Heats Domestic Hot Water Water, pre-heated by the hotel s solar panels and/or various heat-pumps, is held in the hotel s pre-heated water holding tanks the water is then cycled through this High Efficiency Boiler and then utilized as the hotel s domestic hot water supply. The boiler itself is a sealed combustion and fan assisted model delivering thermal efficiencies of 85% to 91%. 10 x 120 USG pre-heat solar storage tanks 1,200 USG high efficient boiler set to 60 C

20t Heat Pump Make: TRANE WEATHERTRON Model: TWA240BW0 Installed: 2008 Purpose: Pre-Heats Domestic Hot Water Using an air to water system, this heat pump removes heat from the air and utilizes it to pre-heat the Domestic Hot Water by use of a heat exchanger. The pre-heated water is held in the hotel s pre-heated water holding tanks.

Chiller Unit Make: TRANE Model: RTAA 100 ton chiller Installed: 2006 Purpose: Chills Water Water is chilled for use in the hotel s air-conditioning system by use of this Chiller Unit. The unit replaced an older model that had been in use since 1986, this more modern and efficient unit reduced the overall building s electrical consumption by more than 21% following installation.

50 ton Multi Stack Make: MULTISTACK Model: MS50Z6C1H-V Installed: 2008 Purpose: Pre-cools water supply for Chiller Unit & Pre-heats water supply for DHW and space heating in building Water is heated using the wasted heat generated by the Chiller Unit. This water is held in the hotel s pre-heated domestic water holding tanks and is providing space heating for the hotel building (so the 2x 2.5 Mio. BTU boilers will not be in operation most of the time. The now cooled water is sent to the Chiller Unit this allows the Chiller Unit to reach its cooling goals while expending less electricity since the water has been pre-cooled. Heat Exchanger 50 tom Multi Stack Heat Pump