00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof



Similar documents
PITCHED ROOF STRUCTURES

ASSEMBLY INSTRUCTIONS Residential Roof solutions

Phoenix Solar AG. Phoenix TectoSun 3 Installation instructions

PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Chelsea Loft Bed WARNING:

RAIL FREE SOLAR ROOF MOUNT

AA Solar and Sun Power Plus

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Andersen Electric Window Opener for Andersen Awning and Roof Windows

EZ-48-3AB Weather Station Mounting Tripod and Mast

HORIZONTAL INSTALLATION

Samuel Shorty Bunk Bed

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

Installation Guide. -- Standing Seam 8 Corrugated Metal Roof Mounting System

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Installation instruction CASAFLEX - Connecting piece DN 100

Installation manual ValkPitched - Insert

OWNER S MANUAL Table Tennis Table Patent Pending

UBBINK SOLAR IN-ROOF SYSTEM

INSTRUCTIONS: LocknCharge Laptop Carts

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

YINGLI SOLAR PV MODULES Installation and User Manual

AZEK Rail Install Guide

Solar Mounting System

Mounting instructions

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Installation manual ValkPitched - Clamp

Beadboard Wall Bookcase

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Beautifully Traditional

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

WARNING! WARNING! ENGLISH 18 ENGLISH

Washer, Electrical Equipment Bond WEEB

How to Install UnderDeck The Original.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

CHROME FRONT BRAKE MASTER CYLINDER KIT

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Owner's Manual & Assembly Instructions

Installation Instructions

39HQ Airovision Air Handling Units

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

CABLE SUPPORT SYSTEMS

Installation Instructions

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Assembly and Usage Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

5800 Temperature Sensor Cable Assembly

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

Greenhouse Assembly Instructions

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

Installation Manual. BYD Wall-mounted AC Charging Box

AluGrid product sheet

All-Season Sunroom Sliding Glass Door Installation Instructions

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

INSTALLATION INSTRUCTIONS

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

RadianceRail Installation Guide

Select Radiators Installation Guide

Residential Roofing Guide

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

Solar Mounting Catalogue

AM/FM ANTENNA RELOCATION KIT

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

Structural Holding System

Machine needle shut-off nozzle type HP

HEAVY DUTY STAIR LIFT SYSTEM Installation and Service Manual

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

INSTALLATION, OPERATION & MAINTENANCE MANUAL

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

2.4M SERIES 1241 ANTENNA

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

Installation Instructions

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Owner s Manual Read and keep this manual. Patents World Wide

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

Removable Aluminium posts

SPIRAL STAIR KIT INSTALLATION MANUAL

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

S4 - Top Hung Window. Outside view. Inside view. Interior frame. Exterior frame. Glazing Panel

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Wind Direction Smart Sensor (S-WDA-M003)

Transcription:

00MK-MA0190-EN00 Mounting System ASSEMBLY INSTRUCTIONS Universal Light system with locking brackets, for sloped roof Rev.02 November 2014

Table of contents General instructions 2 General safety instructions 3 Universal Light system with locking brackets, for sloped roof 4 Regulations 5 Components required 6 Tools required 8 Assembly instructions 9 Notes 12 Table of contents 1

General instructions Ensure you observe the general fitting and maintenance prescriptions. If you need any clarifications, please call immediately our customer service at number +39 011 19870791. 1.Thesan Mounting System is constantly evolving and may therefore be subject to changes; before starting, check the version of the assembly instructions in your possession and, if it is not up to date, send a request for an updated version to info@thesan.com. All personnel on work site must have a copy of the assembly instructions. 2.The 12-year warranty is assured by our warranty certificate subject to compliance with assembly instructions, general instructions and general safety prescriptions provided by Thesan S.p.A. 3.In case of non-compliance with the assembly instructions, or are not used the parts listed, the warranty is void and Thesan declines all liability. 4.To disassemble the system, perform the assembly steps in reverse sequence. 5.Follow the instructions of the manufacturer of PV modules and the manufacturer of inverters. 6.Is necessary to provide routine maintenance on all parts of the plant, on a regular basis (maximum each 6 months). Visual inspections: Atmospheric events damages Dirt, musk and other deposits Corrosion of metal parts Stability of the structure Sealing of the roof cover Mechanical inspections: Check the tightness of nuts and, if necessary, retighten the nuts to the torque given in the assembly instructions The areas under the modules are more prone to becoming dirty, so remove all the deposits during the routine maintenance. General instructions 2

General safety instructions Ensure you observe the general safety fitting and maintenance prescriptions. If you need any clarifications, please call immediately our customer service at number +39 011 19870791. 1.Fitting and commissioning of the systems must be carried out exclusively by skilled personnel who, thanks to their specific training or professional experience, are able to ensure that the work is performed correctly and to high standards. 2.The existing structures on which the system is to be fitted must be checked to ensure that the loading capacity of the building/structures is adequate. 3.Observe all regulations and local and national building regulations, and provisions relating to the environment. 4.Observe all regulations and national laws and local regulations regarding health and safety, accident prevention and the requirements of professional associations. In particular, it is necessary: Wear personal protective equipment: safety helmet, safety gloves, safety shoes, etc. If the system is to be fitted on an elevated surface comply with safety regulations for work at heights by using safety harnesses, falling objects signs, etc. At least two people must be on the work site during the fitting procedures, so that one person can provide first aid or call emergency services in case of accident. 5.Efficient grounding system is essential. If necessary, use the lightening protection devices. 6.You can not cut the mounting rails. In the event that Thesan S.p.a. Technical Dept. requires to cut the profiles, depending on the specific project to be carried out, you must make sure to remove the burrson the surfaces affected by the cut in order to eliminateany possible risk of injury. Also you need to make surethat the cutted rails are not curvy. 7.The electrical installation must be carried out exclusively by skilled personnel who, thanks to their specific training or professional experience, are able to ensure that the work is performed correctly and to high standards. The wiring of the photovoltaic modules must be made to avoid the possible creation of loops. General safety instructions 3

Universal Light system with locking brackets, for sloped roof FEATURES OF THE SYSTEM Thanks to the significant reduction in the number of components, Thesan Mounting System allows a reduction of approximately 57% in the amount of time required to fit the photovoltaic modules, compared to similar mounting systems of key competitors. Robustness, practicality, and reliability over time are key characteristics of the system. Suitable for photovoltaic modules with and without frame. Thesan is leader in guaranteeing, on request, a reliable and efficient after-sales service, which is at customers disposal for any requirements. All Thesan Mounting System documents are available at: www.thesan.com For any need or clarification you may required, please contact our customer service: tel. 0039 011 19870791 e-mail ufficio.tecnico@thesan.com The Universal Light system with locking brackets, for sloped roof, is a not pre-assembled mounting system for photovoltaic modules. In order to ensure safe and proper fitting of the system, each step described in these instructions must be carefully and accurately followed. At each step, necessary materials and equipment are listed. For any inconvenience or misunderstandings please call immediately our customer service. Universal Light system with locking brackets, for sloped roof 4

Regulations The installation of the system have to be performed in accordance to the following regulations, or similar standards which are being used in the region of installation. The quality level of the standards need to be equal or higher as the standards which are mentioned. BGV A1 BGV A3 BGV C22 DIN EN 62305 DIN VDE 0185 DIN VDE 0100 part 410 DIN VDE 0100 part 712 DIN VDE 0105 DIN VDE 0298 DIN 18338 DIN 18451 DIN 4102 DIN 18015 DIN 18531 VDS 2023 Eurocode 1 Eurocode 1 Eurocode 3 Eurocode 9 Accident prevention regulations General rules Power system and equipment Construction work Lighting protection Lighting protection Components Grounding Electrical installations of buildings Operation of electrical installation Application of cables and cords in power installations Roofing work Scaffolding work Fire behavior of building materials and building components Electrical installations in residential buildings Waterproofing of roofs Electrical installations in structural works with mainly flammable materials Wind loads Snow loads Design of steel structures Design of aluminum structures Regulations 5

Components Required RAILS Universal Light Material: Aluminium Alternatives available: SO-AYP13L3-0000 (3,1 m) SO-AYP13L6-0000 (6,2 m) Locking bracket with slot Material: Aluminium SO-AY036-0001 FASTENERS Self-drilling wood screw or Self-drilling screw or Concrete screw anchor Depending on the type of module, refer to general catalogue. Adhesive and structural tape SOST-V501-003M (25mmx33m) CLAMP SETS Clamp sets for frameless modules Material: Aluminium Clamp sets for modules with frame Material: Aluminium Depending on the type of module, refer to general catalogue. Depending on the type of module, refer to general catalogue. Components Required 6

Clamps for modules with frame Material: Aluminium Depending on the type of module, refer to general catalogue. CLAMPS Hammer head screw, M8 Material: Stainless steel Alternatives available: SOST-V209-00TH (M8X30mm) SOST-V206-00TH (M8X36mm) SOST-V210-00TH (M8X42mm) Nut with safety fit, M8, (DIN 6923) Material: Stainless steel 0042-80500-0000 OPTIONAL Other accessories available on request. Consult the general catalogue. For the possible use of alternative components contact Thesan S.p.a. technical department at ufficio.tecnico@thesan.com Components required 7

Tools Required Wireless screwdriver Insert n 8, n 10 and n 13 for screwdriver Torque wrench Mark line cord Metric tape measure Bubble level Tools Required 8

Assembly instructions Step 1 Preliminary checks a. Check the design measurements on the roof on which the system is to be fitted. b. Provide a minimum distance of the rails from the edge of the roof of 500 mm. This system is highly versatile, hence it is ideal for installation on different types of roofs and surfaces, such as: - Corrugated sheet metal roofs; - Wooden porch roofs; - Metal porch roofs; - Pitched roofs with counter batten Step 2 Alignment a Use the line marker cord to trace the positions where to apply the adhesive and structural tape. The distance will be determined by Thesan Technical Dept. (or Thesan configurator software) depending on the specific project to be carried out. In case of different assembly solutions the warranty is void. Step 3 Applying the adhesive and structural tapes a. Make sure that the metal surface where the tapes are to be applied is clean. If there are traces of dirt, remove any residual particles with a rag soaked in an oil-free cleaner. b. Cut the tape into lengths of approx. 10 cm. c. Remove the protective film from the tape and apply the latter, with a slight pressure, to the support surface. Assembly instructions 9

Step 4 Positioning the Universal Light mounting rails a. Remove the protective fi lm from the upper side of structural adhesive tape, previously applied on the corrugated metal sheet. b. Position the Universal Light mounting rail aligned with the tape, taking into account the trace previously made with the line marker cord in order to ensure correct alignment of the rails. c. Place a couple of brackets, one on the left side and one on the right side of the rail, close to the previously applied tapes. d. Fasten the brackets to the support surface. Use suitable fasteners depending on the support surface: - Wood surfaces use stainless steel torx drive self- drilling screws, fl at head - Metal surface use galvanized steel hex head self- drilling screws - Concrete surfaces use concrete wall plugs The type of fastener will be determined by Thesan Technical Dept. (or Thesan confi gurator software) depending on the specifi c project to be carried out. e. Space each profi le from the next by at least 1 cm in order to allow a safety margin in the case of thermalexpansion. Step 5 Positioning and fixing the photovoltaic modules If the clamps you are using are not preassembled, insert the hammer head screw in the specific opening in the upper side of the mounting rail, turn the screw of 90 clockwise, position the clamp and partially tighten the nut with safety fit. Upper side Bottom side Attention: Follow the instructions of the manufacturer of the PV modules. b. If the PV module is mounted landscape, the long side of the clamp must be in longitudinal position respect the mounting rail, if instead the PV module is mounted portrait, the long side of the clamp must be in orthogonal position respect the mounting rail. c. Position the photovoltaic module and fully tighten the nut with safety fit to a torque of 14Nm. d. Ensure the correct position of the clamp compared to the frame of PV module. The vertical walls of the clamp must adhere perfectly to the frame of the module: a. If pre-assembled clamp sets are used, insert the hammer head screw into the specific opening in the upper side of the mounting rail, press the clamp gently to turn the screw of 90 clockwise. Make sure that hammer head screw is in an orthogonal position respect to the rail, and that the spring of the clamp makes completely adhere the hammer head screw to the rail. Middle and final clamps for PV module with frame Pre-assembled middle and final clamps for PV module with frame Module Rail Module Rail Assembly instructions 10

Step 6 Grounding system a. Efficient grounding system is essential. b. Fastened with a screw the ground wire at any point on the aluminium rail, using only stainless steel fasteners and components. c. Tighten the screw securely. Assembly instructions 11

Notes Notes 12

www.thesan.com Thesan S.p.A. - Via Torino 25-10050 Chiusa di San Michele (TO) Italy - tel. +39 011 19870791 - info@thesan.com 13