LP OSB Sheathing & Structural 1 Sheathing



Similar documents
B. Related categories: The following categories contain requirements that relate to this section:

Asphalt Shingle Application Requirements

POST AND FRAME STRUCTURES (Pole Barns)

Featuring TJ Rim Board and TimberStrand LSL

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Chapter 6 ROOF-CEILING SYSTEMS

Load-Span Tables for PS-1 Plywood

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

December J-Ply Roofing, Flooring and Decking

CHAPTER 7: Building Systems ROOFING SYSTEMS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Discipline: Structural Issued

Page & Turnbull imagining change in historic environments through design, research, and technology

MASTERFORMAT SPECIFICATION

Formwork for Concrete

Residential Roofing Guide

AUTHORIZATION TO MARK

Common Errors in Truss Design

CITY OF LOS ANGELES CALIFORNIA

STANDARD OPEN PATIO COVER

PART 1 GENERAL 1.1 SECTION INCLUDES

Mark Cramer Inspection Services, Inc.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

application instructions

Breakaway Walls

Residential Deck Safety, Construction, and Repair

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Post and Beam Construction

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Frequently Asked Questions LP SmartSide Siding, Trim, and Soffit

GreenGuard Housewrap Installation Guide

6 RETROFITTING POST & PIER HOUSES

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

Installation Instructions

Diaphragms and Shear Walls DESIGN/CONSTRUCTION GUIDE

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Structural Plywood. Design and Application Guide

Design of Cold-Formed Steel Shear Walls

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

H-Stud Area Separation Wall System

PERFORMANCE RATED I-JOISTS

Protecting YOUR NEW HOME FROM Wind Damage

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

Guide Specifications for Maple Flooring Systems

GYPSUM AREA SEPARATION FIREWALLS GA

REPORT NUMBER: COQ-003 ORIGINAL ISSUE DATE: July 19, 2013

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

NORDIC ENGINEERED WOOD RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC JOISTTM FSC-CERTIFIED PRODUCTS AVAILABLE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

Detached accessory structures that contain no conditioned floor area are exempt.

Fire-Retardant-Treated (FRT) Plywood

High Wind & Hail Standards

MUNICODE SERVICES LTD.

AMERICAN GOTHIC PLAYHOUSE

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

How to secure your property after a disaster

General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

How To Make An Oriented Strand Board

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

TJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists

Section A Roof Truss

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

CertainTeed. Shaftliner For A rea Separation Firewalls

Window Installation Instructions

Handling, Erection and Bracing of Wood Trusses

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Chapter 3 Pre-Installation, Foundations and Piers

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH EVALUATION SUBJECT:

How to Install Hardwood Flooring Over a Sub Floor

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

ICC-ES Evaluation Report

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

DUROCK Brand Cement Board. installation guide. Substrate and ceramic tile installation for walls, floors, countertops and wall shields.

Bracing Webs in Trusses that have Dissimilar Configurations

ABSeam Panel Overview and Installation Instructions

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Perforated Shearwall Design Method 1

Transcription:

Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48 oc 290 ** Live load for 24" oc span conditions. 10lb psf dead load assumed. Manufactured Home Installation Panels are available that carry Series Mobile Home Roof Sheathing Rating N-216R. Sheathing panels 3/8" thick may be installed perpendicular or parallel to supports, spaced a maximum of 16" oc, and will support a 30 psf live load without exceeding a deflection limit of 1/180. No edge support is required when applied with strength axis perpendicular to supports. Manufacturer LP Product Description Basic Uses OSB sheathing panels are designed for use in roof, wall and two-layer subfloor systems in commercial and residential projects, maintenance, remodeling or new construction. Technical Data Applicable Standards OSB sheathing panels comply with the following industry standards and certifications. The panels conform to the ICC Evaluation Service Legacy Report NER-108 for The Engineered Wood Association Performance Rating Standard PRP 108, and are approved under the Rated Sheathing Standard as follows: The panels also conform to HUD Use of Materials Bulletin No. UM-40c. The panels carry the trademark: Panel Grade Span Rating Exposure Durability Classification RATED SHEATHING 24/16 7/16 INCH SIZED FOR SPACING EXPOSURE 1 402 PRP 108 Thickness s Performance-Rated Panel Standard Mill Number Wall panels 7/16" thick may be used on studs spaced up to 24" oc. Some OSB sheathing panels 3/8" thick are available that carry Series Mobile Home Roof Sheathing Rating N-216R. OSB sheathing panels sold by LP in Canada meet or exceed the requirements established by the Canadian Standard Association CSA 0437 and/or CSA 0325.

ORIENTED STRAND BOARD STRUCTURAL 1 SHEATHING PANELS Manufacturer LP Product Description Basic Uses LP s OSB Structural 1 sheathing panels are designed to perform as roof, sidewall and floor systems, where high wind or earthquake conditions may occur. OSB Structural 1 sheathing panels are equally suited for pitched or flat roof applications. OSB Structural 1 sheathing panels can be used in commercial and residential projects, such as industrial buildings, mobile and modular home construction or in any application requiring high strength and superior shear values. Technical Properties Top Notch OSB Sheathing complies with the following industry standards and certifications: LP OSB panels are -certified (The Engineered Wood Association), and are manufactured in conformance with PRP-108 and U.S. Voluntary Product Standard PS2. These standards are recognized in the Uniform Building Code, the International Building Code and the International Residential Code, and by the ICC Evaluation Legacy Report NER-108 and by HUD Use of Materials Bulletin No. 40c. LP OSB panels sold in Canada are also manufactured in conformance with CAN/CSA-0325, which is recognized in the National Building Code of Canada. NOTE: Material Safety Data Sheets are available from the LP website: www.lpcorp.com. OSB Structural 1 Rated Sheathing Roof Panels Span Ratings Max Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 ** Live load for 24" oc span conditions. 10lb psf dead load assumed. Wall panels 7/16" thick may be used in studs spaced up to 24" oc. Structural 1 OSB panels have superior maximum live load over standard OSB when installed with the long axis parallel to the structural supports. OSB sheathing panels sold by LP in Canada meet or exceed the requirements established by the Canadian Standard Association CSA 0325 and/or CSA 0427. Panel Grade Span Rating Exposure Durability Classification The panels also conform to HUD Use of Materials Bulletin No. UM-40c. Fire Performance RATED SHEATHING STRUCTURAL 1 32/16 15/32 INCH SIZED FOR SPACING EXPOSURE 1 378 PRP 108 s Performance-Rated Panel Standard Thickness Mill Number The surface burning characteristics of unfinished OSB panels have a Class C or Class 3 rating based on U.L. Control No. 11H7.

ALLOWABLE SHEAR (POUNDS PER FOOT) FOR PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS-FIR, LARCH, OR SOUTHERN PINE (a) FOR WIND OR SEISMIC LOADING (b,h,i,j) (See also IBC table 2306.4.1) Panels Applied Over Panels Applied Direct to Framing 1/2" or 5/8" Gypsum Sheathing Panel Minimum Minimum Grade Nominal Nail Nail Size Nail Spacing Nail Size ) Nail Spacing Panel Penetration (Common or at Panel Edge (in.) (common or at Panel Edges (in.) Thickness in Framing Galvanized Box) Galvanized (in.) (in.) (k) 6 4 3 2 (e) Box) (k) 6 4 3 2 (e) 5/16 1-1/4 6d 200 300 390 510 8d 200 300 390 510 3/8 230 (d) 360 (d) 460 (d) 610 (d) Structural l 7/16 1-3/8 8d 255 (d) 395 (d) 505 (d) 670 (d) 10d 280 430 550 (f) 730 Grades 15/32 280 430 550 730 15/32 1-1/2 10d 340 510 665 (f) 870 (a) (b) (c) (d) (e) (f) For framing of other species: (1) Find specific gravity for species of lumber in the AF&PA National Design Specification. (2) For common or galvanized box nails, find shear value from table above for nail size for actual grade. (3) Multiply value by the following adjustment factor: Specific Gravity Adjustment Factor = [1 (0.5-SG)], where SG = specific gravity of the framing. This adjustment shall not be greater than 1. All panel edges backed with 2-inch nominal or wider framing. Install panels either horizontally or vertically. Space nails maximum 6 inches o.c. along intermediate framing members for 3/8-inch and 7/16-inch panels installed on studs spaced 24 inches o.c. For other conditions and panel thicknesses, space nails maximum 12 inches o.c. on intermediate supports. Fasteners shall be located 3/8 inch from panel edges. 3/8-inch or RATED SIDING 16 o.c. is minimum recommended when applied direct to framing as exterior siding. Shears may be increased to values shown for 15/32-inch sheathing with same nailing provided (1) studs are spaced a maximum of 16 inches o.c., or (2) if panels are applied with strength axis across studs. Framing at adjoining panel edges shall be 3-inch nominal or wider, and nails shall be staggered where nails are spaced 2 inches o.c. Check local code for variations of these requirements. Framing at adjoining panel edges shall be 3-inch nominal or wider, and nails shall be staggered where 10d nails (3 x 0.148 ) having penetration into framing of more than 1-1/2 inches are spaced 3 inches o.c. Check local code for variations of these requirements. RECOMMENDED ROOF LOADS (PSF) FOR RATED SHEATHING WITH STRENGTH AXIS PARALLEL TO SUPPORTS (e)(f) (OSB, composite and 5-ply/5-layer plywood panels unless otherwise noted) Panel Thickness Span Maximum Span Load at Maximum Span Grade (in.) Rating (in.) Live Total Structural l Rated Sheathing Rated Sheathing 7/16 24/0, 24/16 24 (d) 20 30 15/32 32/16 24 35 (a) 45 (a) 1/2 32/16 24 40 (a) 50 (a) 19/32, 5/8 40/20 24 70 80 23/32, 3/4 48/24 24 90 100 7/16 (b) 24/0, 24/16 16 40 50 15/32 (b) 32/16 24 (d) 20 25 1/2 (b) 24/0, 32/16 24 (d) 25 30 19/32 40/20 24 40 (c) 50 (c) 5/8 32/16,40/20 24 45 (c) 55 (c) 23/32, 3/4 40/20, 48/24 24 60 (c) 65 (c) (a) For 4-ply plywood marked PS 1, reduce load by 15 psf. (b) Composite panels must be 19/32 inch or thicker. (c) For composite and 4-ply plywood panels, reduce load by 15 psf. (d) Solid blocking recommended at panel ends for 24-inch span. (e) For guaranteed or warranted roofs, contact membrane manufacturer for acceptable deck. (f ) Provide edge support.

RECOMMENDED SHEAR (POUNDS PER FOOT) FOR HORIZONTAL PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS-FIR, LARCH OR SOUTHERN PINE (a) FOR WIND OR SEISMIC LOADING Blocked Diaphragms Nail Spacing (in.) at Diaphragm Boundaries at Continuous Panel Edges Parallel to Load and at All Panel Edges Unblocked Diaphragms Nails Spaced 6" Max. at Supported Edges (b) 6 4 2-1/2 (c) 2 (c) Minimum Case 1 Minimum Minimum Nominal (No Unblocked Nail Nominal Width of Edges or Penetration Panel Framing Continuous Panel Common in Framing Thickness Member Nail Spacing (in.) Joints Parallel All Other Grade Nail Size (f) (in.) (in.) (in.) at Other Panel Edges to Load) Configurations 6 6 4 3 Structural l Grades 8d 2 270 360 530 600 240 180 1-3/8 3/8 3 300 400 600 675 265 200 10d (d) 1-1/2 15/32 2 320 425 640 730 285 215 3 360 480 720 820 320 240 (a) For framing of other species: (1) Find specific gravity for species of lumber in the AFPA National Design Specification. (2) Find shear value from table above for nail size for actual grade. (3) Multiply value by the following adjustment factor: Specific Gravity Adjustment Factor = [1 - (0.5 - SG)], where SG = specific gravity of the framing. This adjustment shall not be greater than 1. (b) Space nails maximum 12 inches o.c. along intermediate framing members (6 in. o.c. when supports are spaced 48 in. o.c. or greater). Fasteners shall be located 3/8 inch from panel edges. (c) Framing at adjoining panel edges shall be 3-in. nominal or wider, and nails shall be staggered where nails are spaced 2 inches o.c. or 2-1/2 inches o.c. (d) Framing at adjoining panel edges shall be 3-in. nominal or wider, and nails shall be staggered where 10d nails having penetration into framing of more than 1-5/8 inches are spaced 3 inches o.c. (e) 8d is recommended minimum for roofs due to negative pressures of high winds. Notes: Design for diaphragm stresses depends on direction of continuous panel joints with reference to load, not on direction of long dimension or strength axis of sheet. Continuous framing may be in either direction for blocked diaphragms SHEATHING PANELS & ORIENTED STRAND BOARD STRUCTURAL 1 SHEATHING PANELS Materials and Fabrication OSB sheathing panels are manufactured to be free of knots, grain defects, splits and other irregularities. The wood strands are mixed with binder, arranged in layers for maximum strength and stability and bonded under heat and pressure. OSB sheathing panels are of a consistent composition, easily handled, sound on both sides, and free of knots, core voids, splits and checks. They are coated on all four edges for added moisture resistance and dimensional stability. OSB sheathing roof panels have a coarse-textured surface that helps provide safe footing on pitched roofs. Workability The panel may be fastened with nails, screws, adhesive or staples. NOTE: Consult your local building authorities regarding acceptability of fastening techniques. The panels may be sawn cleanly, and may be routed or drilled with standard woodworking tools. Sizes OSB sheathing panels are fabricated in standard 4' x 8' size, and in thicknesses ranging from 3/8" to 1-1/8." Sizes 4' x 9' and 4' x 10,' and oversized panels are subject to availability.

Limitations OSB SHEATHING PANELS ARE NOT FOR UNPROTECTED EXTERIOR USE; they must be covered with siding panels or other type of exterior wall cladding or roofing material. Normal exposure to weather during ordinary construction delays will not damage the panels. ADDITIONAL PROTECTIVE MEASURES ARE RECOMMENDED FOR EXTENDED ADVERSE WEATHER CONDITIONS. EXCEPTION: Panels identified as Exposure 1 are designed to be used for roof sheathing where exposed on the underside such as on eves. Slight surface flaking or thickness swells caused by excessive rain or brief exposure to standing water will not affect the panels structural performance. Physical Properties OSB sheathing wall panels provide sufficient racking strength to meet corner bracing requirements. Panels are stiff and strong and have a low coefficient of lineal expansion. For further technical and engineering information and Material Safety Data Sheets, contact your LP sales office listed under the Technical Services/ Sales Information section. Environmental Impact LP building products are manufactured in accordance with the company s policy on protection of the environment which includes: Use of environmental control technology and energy efficient equipment to conserve resources. Using process by-products to produce heat and electricity, thereby conserving nonrenewable energy sources. Harvesting timberland following the soundest practices dictated by the ecological requirements of the specific type of forest. Managing forests for fiber growth while also promoting biodiversity. Developing and marketing products which do not require material from sensitive environments such as old growth forests. Installation General Requirements Comply with local safety regulations when installing roof, wall or subfloor sheathing. Comply with the following manufacturer s instructions and with s Engineered Wood Construction Guide, Form No. E30T/Revised March 2005. Storage and Handling Store panels in clean, dry areas off the ground. If possible, store indoors. If stored outside, cover with plastic sheets or tarps. Keep cover open and away from the sides and bottom of panels to allow for air circulation. Additional protective measures may be necessary during extended adverse weather conditions.

Roof Installation Install with the long dimension or strength axis of the panel across supports, and with the panel continuous over two or more spans. Place skid-resistant side up. Wear skid-resistant shoes when installing roof sheathing. Suitable edge support shall be provided where indicated on drawings by use of panel clips. Panel end joints shall occur over framing. Provide 1/8" minimum space at panel ends and edges. Nail 6" oc along supported panel edges and 12" oc at intermediate supports. Use 8d common nails for panels up to 1." For panels over 1," use 8d ring-shank or 10d common nails. Other code-approved fasteners may be used. Cover roof sheathing as soon as possible with roofing felt or shingle underlayment for protection against excessive moisture prior to roofing. Allow OSB sheathing to dry before installing roofing materials. Do not install roofing materials over wet substrate. NOTE: Check with your local building department before deciding on an installation method. Wall Installation OSB sheathing wall panels may be installed vertically or horizontally. In horizontal installations, stagger joints a minimum of one stud space. Provide 1/8" minimum space between panel ends and edges. Unless otherwise specified, for panels up to 1/2" thick, fasten with 6d common nails located 6" oc along supported panel edges, and 12" oc over intermediate supports. For panels 1" and thicker, fasten with 8d common smooth or ring-shank nails, spaced 6" along supported panel edges and ends and 12" oc over intermediate supports. Other code-approved fasteners may be used. In interior installation garages or interior wall paneling 3/8" thick panels may be applied to studs installed 24" oc. Provide a minimum 1/8" spacing between panel ends and edges. For further installation instructions refer to the Engineered Wood Construction Guide. This publication is available from (253) 565-6600. Availability OSB sheathing panels are available directly from LP s manufacturing plants by railcar, as well as piggyback and truckload shipment. Call LP customer service or visit our web site for more information on OSB structural panels and other LP products. Customer Service: 800.648.6893 www.lpcorp.com Sales Offices: Conroe, Texas 800.964.6310 Schaumburg, Illinois 800.365.7672 Montreal, Quebec 514.861.4724 LP is a registered trademark of Louisiana-Pacific Corporation. and Struc 1 are registered trademarks of The Engineered Wood Association. 2005 Louisiana-Pacific Corporation. All rights reserved. Printed in USA. Specifications subject to change without notice. MW 5M NOTE: LP periodically updates and revises its product information. To verify that this version is current, please contact the sales office listed above. 0S8006IN 8/05