Reprocessing. Critical & Semi-Critical Equipment



Similar documents
Infection Prevention + Control

position statement INFECTION CONTROL INTRODUCTION POSITION STATEMENT PERFORMANCE EXPECTATIONS

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

InfectIon PreventIon checklist for outpatient settings:

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

Cleaning and High Level Disinfection of Semi-Critical Medical Devices

REPROCESSING OF FLEXIBLE CYSTOSCOPES

Alberta Health. Standards for Cleaning, Disinfection and Sterilization of Reusable Medical Devices for Health Care Facilities and Settings

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

Cidex OPA Solution Training Checklist and Competency for Semi-Critical Medical Devices

1/22/2012. When is it a good time to learn about sterile processing in your facility? Continuing Education Contact Hours. Learning Objectives

Brock University Facilities Management Operating Procedures

Body Art Facility Infection Prevention And Control Plan Guideline

Biosafety Spill Response Guide

INFECTION CONTROL SURVEYOR WORKSHEET

BC Children s Hospital Mistake-Proofing Equipment Reprocessing. Laurence Bayzand Janice Penner Sue Fuller Blamey

Cleaning, Disinfection and Sterilization

Standard laryngoscope blade assemblies Directions for use

Arizona State University Institutional Animal Care and Use Committee STANDARD INSTITUTIONAL GUIDELINE RODENT SURGERY

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

Inherent in any infection control strategy are two significant concepts: (i) Routine Practices, and (ii) Risk Assessment.

33 Infection Control Techniques

Cleaning, Disinfection, and Sterilization. Basics of Infection Prevention 2-Day Mini-Course 2013

THE BASICS OF DECONTAMINATION

01.05 Cleaning, Sterilization, High-Level Disinfection and Storage of Patient Care Devices and Other Items

Are You Always Ready for The Joint Commission or CMS Survey?

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Appendix J IBC Biohazard Spill Management Plan

Laboratory Biosafty In Molecular Biology and its levels

Infection Control in the Dental Practice through Proper Sterilization

THE BASICS OF STERILIZATION

Disinfection and Sterilization of reusable medical devices in General Practice

Response to Biological Spills in the Laboratory (Intentional or Accidental)

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Private Water Supplies Sampling Manual. A Field Guide

Bloodborne Pathogens Program Revised July,

POLICY 08:18:00 BLOODBORNE PATHOGENS CONTROL PLAN

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

Mercyhurst University Athletic Training Program Bloodborne Pathogens Exposure Control Plan

4. Infection control measures

Steam Sterilization Cycles for Lab Applications

Best Practices for Cleaning, Disinfection and Sterilization in Health Authorities March 2007

Infectious Waste Management Plan

STERILE PROCESSING MANUAL Policy & Procedure

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY. Methicillin-resistant Staph aureus: Management in the Outpatient Setting

INFECTION CONTROL POLICY MANUAL

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes

INFECTION PREVENTION CHECKLIST FOR OUTPATIENT SETTINGS: MINIMUM EXPECTATIONS FOR SAFE CARE

Biosafety Guidelines. 5. Pipetting Mechanical pipetting devices must be available and used. Mouth pipetting is prohibited.

Reprocessing Flexible Endoscopes Avoiding Reprocessing Errors Critical for Infection Prevention and Control

Federal Wage System Job Grading Standard For Laboratory Working, Table of Contents

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

MEDICAL WASTE MANAGEMENT

THE BASICS OF PACKAGING

KGI MEDICAL WASTE MANAGEMENT PLAN

Best Practices for Loaner Surgical Instruments

Water should be removed as soon as possible once the safety of the structure has been verified.

Safe Handling of Cytotoxic Materials

Clinical Guideline for: Aseptic Technique

BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

BESTPRACTICE. HTM01-05 Q&A: You can now follow us on Twitter! We have launched our HTM01-05 questions and answers service on Twitter.

or

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

GUIDELINES: Aseptic Technique for Rodent Survival Surgeries Surgical Area Animal Preparation 1.

Hand Hygiene and Infection Control

Chemotherapy Spill Response:

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

1.40 Prevention of Nosocomial Pneumonia

Transducer and System Care and Cleaning Koninklijke Philips N.V. All rights reserved. Published in USA.

ResMed Masks. Clinical Use Only. Disinfection and Sterilization Guide. NASAL MASKS Mirage Activa. Mirage Kidsta. Mirage Vista.

Biosafety Level 2 Criteria

Laboratory Safety Inspection Checklist (Biology and Biochemistry)

Ambulance Service. Patient Care. and. Transportation Standards

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

STERILIZATION د STERILIZATION

INFECTION CONTROL PRECAUTIONS

Health Service Executive Code of Practice for Decontamination of Reusable Invasive Medical Devices

BSL 1 Laboratory Biosafety Manual

OCCUPATIONAL EXPOSURE TO BLOODBORNE PATHOGENS (29 CFR )

Bed Cleaning Procedure

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

OSHA s Bloodborne Pathogens Standard

INSTITUTIONAL POLICY AND PROCEDURE (IPP) Department: Manual: Section:

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

CENTRAL SERVICE REGULATIONS FOR AMBULATORY SURGERY CENTERS

Mock OSHA Inspection:

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)

In use test of a Washer-disinfector reprocessing of flexible endoscopes

Decontamination and Waste Management

IX. Decontamination and Spills

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

Biomedical Waste Management Plan

To provide direction for the safe handling, administration and disposal of hazardous drugs.

Giving safe injections

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

Transcription:

Reprocessing (Cleaning, Disinfection & Sterilization) Critical & Semi-Critical Equipment - A Physician Toolkit - Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit

Table of Contents Preface...1 Basic Physician Office Supplies for Reprocessing and Semi-Critical Medical Equipment...2 Sterilization Monitoring...3 Policies, Procedures & Guidelines...4 Reprocessing Medical Equipment Policy, Procedures & Guidelines...5 Policy Template for Reprocessing of Medical Equipment...9 Procedure Template for Steam Sterilization...10 Procedure Template for High Level Disinfection...11 Control Sheet Template for Cleaning and Disinfection of Flexible Endoscopes Manually...13 Control Sheet Template for Cleaning and Disinfection of Flexible Endoscopes Using Automated Endoscope Reprocessor...14 Sterilization Log Template...15 Common Deficiencies...16 Cleaning, Disinfection & Sterilization Products...17 Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit

Preface This document, A Physician Toolkit for Reprocessing Critical and Semi-Critical Medical Equipment, has been developed to assist office physicians and their staff to meet best practice standards on reprocessing medical equipment. Additional references and standards that physicians and their staff should be aware of and compliant with are: Provincial Infectious Diseases Committee (PIDAC) Best Practices for Cleaning, Disinfection and Sterilization, 2006; Canadian Committee on Antibiotic Resistance (CCAR) Infection Prevention & Control Best Practices, 2007; and A Physician s Guide to Occupational Health and Safety Responsibilities. Links to all of the above noted references are available on the College s website at www.cpsa.ab.ca/collegeprograms/ipac.asp. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 1

Basic Physician Office Supplies for Reprocessing Critical & Semi-Critical Medical Equipment Personal Protective Equipment (PPE) Face Protection: mask, protective eye ware (safety glasses or goggles) and/or full face shield). Gloves: gloves must be of sufficient weight to be highly tear resistant (regular exam gloves are not appropriate protection for reprocessing). Gowns: gowns must be of a quality to provide an adequate barrier to moisture (isolation gowns are not appropriate). Cleaning Brushes (reusable or disposable) or cloths for physical cleaning. Detergent or enzymatic cleaning solutions (e.g. Medzyme). High Level Disinfection High level disinfectant solution (e.g. Glutaraldehyde). Products must have a Drug Identification Number (DIN) from Health Canada. High level disinfectant solution chemical test strips. Log and documentation record forms. Sterilization (manufacturers may have starter kits which include all of the products listed here) External chemical indicator/autoclave tape (maybe built-in with peel pouches) placed on packages with each load. Internal chemical indicator: placed inside each package for sterilization. Biological indicator (spore-laden strips or vials) (usually Geobacillus stearothermophilus for steam sterilizers). Used once each day the sterilizer is in use, or with every load if sterilizing implantable devices. Logs books/forms for documentation of sterilization parameters and autoclave maintenance. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 2

Sterilization Monitoring Sterilization of medical equipment is a two-step process involving: (i) (ii) Decontamination (aka cleaning) to remove >80% of microbes; and Sterilization to kill the remaining microbes. Steam autoclaves are the most efficient and non-toxic method of sterilization in a physician office setting. Because of the difficulty in proving the sterility of a medical instrument, the effectiveness of the sterilization process must be monitored. Three complementary types of monitoring are required: Mechanical/Digital indicators to monitor the autoclave s physical parameters (time, temperature and pressure) for each cycle/load; Chemical indicators - external indicators on the outside of each wrapped package and internal chemical indicators inside each package, which change color when exposed to the right conditions for sterilization; and Biological Indicators that confirm the actual annihilation of microbial spores. All three types of monitors are important to confirming that the conditions necessary to achieve sterility have been met. Among these, biological indicators may be the most unfamiliar to physicians. Options for biological monitoring include: Purchasing a self-contained testing kit with incubator for on-site monitoring; or Purchasing only the spore strips, and then transporting them to a microbiology laboratory that offers environmental testing. (Unfortunately, few laboratories in the province offer this service.) Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 3

Policies, Procedures & Guidelines The following policies, procedures, guidelines and templates are not official documents of the College of Physicians & Surgeons of Alberta. They are provided for information only. We hope these documents will assist you in creating your own specific documents for your office setting. Comments and questions can be forwarded to tlubkey@cpsa.ab.ca. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 4

Reprocessing Medical Equipment Policy, Procedures & Guidelines The following information is provided to assist you in developing policies and procedures relating to reprocessing of medical equipment in the office setting. Templates for developing office/clinic based policy and procedures are included. A. General Requirements: 1. Medical equipment that is to be reprocessed must be labeled reusable by the manufacturer and must be accompanied by the manufacturer s written instructions for reprocessing (cleaning, disinfection and sterilization). 2. Critical or semi-critical medical equipment labeled as single use or disposable shall not be reprocessed. 3. In order to determine the level of reprocessing that is required for a piece of medical equipment, the following risk classification is used: Critical equipment - contacts sterile tissue or the vascular system and requires sterilization. (surgical instruments, biopsy forceps, suture scissors, devices entering sterile body cavities, etc.) Semi-critical equipment - comes in contact with intact mucous membranes or non-intact skin and requires a minimum of high level disinfection (vaginal specula, nasal specula, vaginal/anal ultrasound probes, gastrointestinal/nasopharyngeal endoscopes, laryngoscopes, etc.) 4. Medical equipment reprocessing must take place in a designated area that is separate from patient care areas, or is not to occur when patients are present. 5. Personnel responsible for reprocessing in the office setting must have documented training. 6. Office-specific procedures are developed for medical equipment reprocessing that are written, current, and incorporate existing recognized standards of practice ( PIDAC, CCAR and AH&W). Manufacturer s instructions must be accessible and incorporated into office specific procedures. 7. Personnel responsible for reprocessing must wear the appropriate personal protective equipment (PPE) (e.g. gowns, gloves and facial protection) while reprocessing medical devices. 8. At least one dedicated sink or hand hygiene station must be present in the reprocessing area. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 5

9. Medical equipment is to be stored in clean areas that are protected from contamination, vermin, excessive handling and crushing. They are NEVER stored beneath the sink, in the soiled equipment cleaning area or in the immediate area where examinations/procedures are performed (e.g. beneath the end of the table where pelvic exams are done.) B. Cleaning: 1. All medical equipment must be cleaned first, using water and detergents or enzymatic solutions that are appropriate for use on instruments, prior to any subsequent disinfection or sterilization. 2. Detergents or enzymatic solutions are used according to manufacturer s instructions that are written on the label. 3. Detergents or enzymatic cleaning solutions are discarded following each use. 4. There are written office-specific procedures for cleaning that include protocols for containment of contaminated equipment at the point of use, transport to disassembly, sorting, soaking, physical removal of soil, rinsing, drying, inspection and wrapping (if necessary). 5. Cleaning may be done manually (using detergent or enzymatic solution, water and friction) or mechanically in an automated washer decontaminator/disinfector. 6. Automated cleaning equipment, if used, must be installed and operated according to the manufacturer s instructions, and a preventive maintenance program for the equipment must be established and documented. 7. If ultrasonic cleaning equipment is used: Pre-cleaning of devices is necessary to remove gross matter; Rinsing of devices with clean, fresh tap water must follow the ultrasonic cycle; Efficacy of the equipment must be tested using a method recommended by the manufacturer; Solution must be changed at least daily and whenever it appears soiled; and The unit must be covered when in operation. 8. Devices must be dried following cleaning. Devices must be dry before storage, immersion in disinfectant or wrapping and sterilization. 9. Devices are visually inspected to ensure that no visible soil remains. Devices that do not pass inspection are returned for re-cleaning. 10. Devices with lumens or channels must be cleaned using an appropriately sized brush or stylet as recommended by the manufacturer. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 6

11. Cleaning accessories (e.g. brushes, sponges) are disposable, or must be thoroughly cleaned and high level disinfected or sterilized between uses. 12. Sinks used for cleaning medical devices are cleaned at least once daily. C. High Level Disinfection 1. Semi-critical medical devices require a minimum of high level disinfection. 2. The disinfectant has a Drug Identification Number (DIN) from Health Canada. 3. The disinfectant label indicates that the product is a chemo sterilant or a high level disinfectant (HLD). 4. The HLD is prepared and used according to the manufacturer s instructions specified on the label, MSDS or accompanying product literature. 5. An appropriate chemical test strip specified by the disinfectant manufacturer is purchased and used to test disinfectant minimum effective concentration (MEC) at least daily. 6. Results of all disinfectant MEC testing are recoded in a log. 7. When opened, each container of chemical test strips is checked using a quality control procedure recommended by the manufacturer to verify accuracy. 8. Results of all quality control testing of test strips are recorded in a log. 9. Containers of test strips are dated when opened and not used beyond the shelf life indicated by the manufacturer. 10. There is documentation that the correct HLD solution is used when solution is changed. 11. Devices are completely immersed in HLD for the recommended time. D. Sterilization 1. Critical equipment is sterilized using an approved process. (Unacceptable sterilization methods include boiling, glass bead sterilizers, microwaves and ultraviolet light.) 2. The sterilizers are installed and have a documented preventive maintenance program according to the manufacturer s recommendations. 3. The type of sterilizer used has cycles capable of sterilizing the instruments that are used in the office setting. Check with sterilizer manufacturer s written claims. 4. There are written procedures for sterilization of all medical equipment. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 7

5. Chemical indicators are placed on the outside of each load and inside each package to be sterilized. 6. Each sterilization cycle is monitored with physical parameters (time, temperature and pressure) that are recorded on a print out or otherwise logged. 7. Sterilizers are monitored with an appropriate biological indicator each day the sterilizer is used. 8. A log of biological indicator monitoring is maintained. 9. There is a written recall procedure that is followed in the event of a failed biological indicator. 10. Each package that is sterilized is labeled with a date and load number. 11. A log is kept of each load and items in the load. 12. Instruments/devices are sterilized in the open position and according to the manufacturer s instructions if disassembly is required for sterilization. 13. All reprocessed instrument sets and devices are stored in a manner to keep them clean and dry. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 8

Policy Template for Reprocessing of Medical Equipment Name/Address of Office/Clinic: Date Issued: Date Reviewed: (Suggest annually): Signature of Owner/Operator of Clinic/Office: Policy - Reprocessing of Medical Equipment/Instruments: Purpose: Reprocessing is the cleaning, disinfection and sterilization of reusable medical equipment between each patient use. The safe use and reprocessing of all reusable medical equipment as well as proper care and maintenance of reprocessing equipment is required to reprocess safely. The following shall be adhered to when reprocessing medical equipment: 1. Items labeled for single use only shall not be reused. 2. The following risk classification shall be used to determine the minimum level of reprocessing to be performed on items that are labeled reusable : Critical: Item that enters sterile body site or vascular system and requires cleaning followed by sterilization. Semi-Critical: Item that comes in contact with intact mucous membranes or non-intact skin and requires cleaning followed by a minimum of high level disinfection. Non-Critical: Item that comes in contact with intact skin that requires cleaning followed by low level disinfection. 3. The manufacturer s instructions for cleaning, disinfection and sterilization of medical equipment shall be utilized and followed in office procedures. 4. Written office/clinic procedures for reprocessing shall be followed. 5. The manufacturer s instructions for installation and preventive maintenance of equipment used in reprocessing medical devices and instruments shall be followed and documented. 6. All processes related to cleaning, disinfection and sterilization of medical equipment shall be monitored and documented. 7. Staff responsible for reprocessing of medical equipment shall be knowledgeable and aware of current standards of practice ( PIDAC, CCAR, AH&W). All education and competencies shall be documented. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 9

Procedure Template for Steam Sterilization Name of Equipment/Instrument: Performed by: Personal Protective Equipment: Gloves Gown Face Shield/Mask Safety glasses/goggles Disassembly instructions, if applicable: (Include pictures or diagrams for complex or unusual equipment.) After each use: 1. Prepare (detergent/enzymatic) solution by adding ml to ml water. (Follow instructions on label for correct concentration.) 2. Immediately immerse instrument into freshly prepared solution of (indicate name of detergent/enzymatic product used) for minutes to prevent drying of soil. (Follow detergent/enzymatic manufacturer s instructions for soak time.) 3. Clean with detergent/enzymatic solution. Requires: Brush Cloth Ultrasonic 4. Rinse with tap water to remove detergent/enzymatic and soil residue. 5. Dry with lint free cloth. 6. Reassemble, as necessary, according to manufacturer s instructions. 7. Wrap in (indicate type of wrapping material: peel pouch) 8. If not part of the wrap, apply internal and external chemical indicators. 9. Label with date of sterilization and load number. 10. Place in sterilizer. 11. Select cycle (appropriate cycle e.g., wrapped, porous, nonporous). 12. Check printout/display to ensure all cycle parameters have been met and sign on print out or in log book. 13. Remove when cycle is finished and packs are completely dry. 14. Storage location:. References (i) (ii) (name of manufacturer) instructions for reprocessing PIDAC or CCAR Date Issued: Date Reviewed: Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 10

Procedure Template for High Level Disinfection Name of Instrument: Performed by: Personal Protective Equipment: Gloves Face Shield/Mask Gown Safety glasses/goggles Disassembly instructions, if applicable: (Include pictures or diagrams for complex or unusual equipment.) Disinfectant used: Check the following: Label Concentration After each use of equipment: Date product activated/opened Results of minimum effective concentration (MEC) testing of disinfectant (done daily at a minimum using appropriate test strip) 1. Prepare (detergent/enzymatic) solution by adding ml to ml water. (Follow instructions on label for correct concentration.) 2. Immediately immerse instrument into freshly prepared solution of (indicate name of detergent/enzymatic product used) for minutes to prevent drying of soil. (Follow detergent/enzymatic manufacturer s instructions for soak time.) 3. Clean with detergent/enzymatic solution. Requires: Brush Cloth Ultrasonic 4. Rinse with clean tap water to remove detergent and soil residue. 5. Dry with lint free cloth to avoid diluting the disinfectant chemical. 6. Remove cover from container of high level disinfectant. 7. Completely immerse device or instrument in high-level disinfectant. 8. Cover container of high level disinfectant and begin timing (set timer). 9. Soak for minutes at room temperature (according to manufacturer s instructions). 10. Rinse with clean tap water using three separate rinses to ensure removal of residual disinfectant. 11. If instrument has channels or lumens, purge with alcohol to facilitate drying. 12. Dry. 13. Storage location: Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 11

References (i) (ii) (iii) (name of manufacturer) instructions for reprocessing (name of device/instrument). Date and source of instructions. Instructions for preparation and use of (name of high level disinfectant) PIDAC/ CCAR Date Issued: Date Reviewed: Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 12

Control Sheet Template for Cleaning and Disinfection of Flexible Endoscopes Manually* Date: Instrument code number or identifier: Endoscope processed (time): I.D. Number of soaking container if more than one container is used for disinfection: Comments: Signature of person reprocessing scope: Ensure water-resistant cap is on Perform leak test Wash exterior of scope Brush valves and piston Brush all channels Suction biopsy port with cleaning adapter Aspirate enzymatic solution through biopsy channel Connect appropriate adaptors for instrument Inject enzymatic product in all channels Soak in enzymatic solution for a minimum of minutes (see enzymatic instructions) Rinse scope and flush all channels with fresh tap water Dry exterior of scope and flush remaining water from channels Completely immerse scope, valves and cleaning brushes in HLD Inject HLD into all channels of the scope using appropriate clean channel adaptors Ensure all channels are filled with HLD and no air pockets remain Ensure temperature of room is not less than degrees (see HLD instructions Set timer for (see HLD instructions) When disinfection time is complete, purge all channels with air to remove HLD Rinse scope and flush channels with three separate rinses of clean tap water (with sterile or submicron filtered water) Dry channels with compressed medical grade air @ psi. (check manufacturer pressure limit) Flush all channels with 70% isopropyl alcohol Repeat dry channels with air Hang/lay scope with all valves and water-resistant cap removed * Adapted from CSA Z314.8-08. Decontamination of reusable medical devices. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 13

Control Sheet Template for Disinfection of Flexible Endoscopes Using Automated Endoscope Reprocessor (AER)* Date: Instrument code number or identifier: Endoscope processed (time): AER used: Comments: Signature of person reprocessing scope: Ensure water-resistant cap is on Perform leak test Wash exterior of scope Brush valves and piston Brush all channels Suction biopsy port with cleaning adapter Aspirate enzymatic solution through biopsy channel Connect appropriate adaptors for instrument Inject enzymatic product in all channels Flush additional ports Soak in enzymatic solution for a minimum of minutes (see enzymatic instructions) Rinse scope and flush all channels with fresh tap water Place in washer using appropriate connectors for final disinfection Place valves, separate from scope, into washer Place cleaning brush(es) into washer Dry with compressed medical grade air at psi (check manufacturer pressure limit) Flush all channels with 70% isopropyl alcohol Repeat dry with compressed medical grade air Hang scope with all valves and water-resistant cap removed Clip initial print out from AER to control sheet * Adapted from CSA Z314.8-08. Decontamination of reusable medical devices. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 14

Sterilization Log Template Sterilization Parameter and Cycle Documentation Autoclave # Date and Time Load Number Contents of the load Temperature achieved ( C or F) Time length of cycle (minutes Internal Chemical Indicator (Pass or Fail) Daily Biological Indicator (Pass or Fail) Daily Biological Indicator Control (Pass or Fail) Internal Chemical indicator: Type in use: Lot number: Expiry: Biological indicator: Type in use: Lot number: Expiry: Reprocessing staff name Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 15

Common Deficiencies Identified from Recent On-Site Audits 1. Biological Monitoring not being performed. 2. That all required Personal Protective Equipment is either not available or not worn by staff when reprocessing. 3. That the manufacturer s instructions for reprocessing equipment are not available. 4. That sterilization monitoring parameters (digital, mechanical chemical and biological) are not documented. 5. That high level disinfectant chemical test strip results are not documented. 6. That quality procedures on new containers of chemical test strips, and lots of biological indicators, are not performed and/or documented. 7. That reprocessing is occurring in patient care areas with patients present. 8. That re-useable cleaning accessories are not cleaned and minimally high level disinfected or sterilized between uses. 9. That documented policies and procedures are not developed for all steps of reprocessing and training procedures for reprocessing staff. 10. Inappropriate wrapping materials and tape used for packaging equipment for sterilization. Use self sealing pouches. 11. Internal, chemical indicators not being placed in each package for sterilization. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 16

Cleaning, Disinfection & Sterilization Products The following products are examples of appropriate cleaning, disinfection and sterilization products. These products are available and can be ordered by contacting a medical supply vendor. Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 17

Instrument Detergents and Enzymatic Cleaners NPH Klenz Neutral Detergent Enzymatic Cleaners - foam or sponge Medzyme Enzymatic Cleaner Instrument Lubricants Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 18

Instrument Cleaning Accessories (Must be disposable, or cleaned and minimally high level disinfected or sterilized between uses.) Glutaraldehyde High Level Disinfectant & Test Strips Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 19

Cidex OPA (orthophtalaldehyde) and test strips Biological Indicators Self-contained BI Process Challenge Device PCD or Test Pack containing BI Log for BI monitoring Incubator Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 20

Chemical Indicators for Sterilization Steam Peracetic Acid (Steris System 1 Steam/Ethylene oxide (EO) Bowie-Dick Air Removal Test Packs Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 21

Post HLD Rinsing (Sterile or sub-micron filtered water is recommended) Sterile Water for Irrigation - 500ml 1000ml, 3000ml volumes Pall-Aquasafe Faucet Water Filter Read labels on all cleaning/ disinfection products. Ensure directions are followed. (Sample enzymatic cleaner label) Reprocessing Critical & Semi-Critical Equipment - A Physician Tool Kit - 22