Surgical technique. Sagitta EVL



Similar documents
Metasul LDH Large Diameter Head

BONE PRESERVATION STEM

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

Rejuvenate Total Hip System Surgical Protocol. Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

CuttingEdge Hip Instrumentation Femoral Surgical Technique for Primary Press-Fit and Cemented Hip Implants.

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

*smith&nephew SLR-PLUS

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

Restoration Modular. Revision Hip System Surgical Protocol

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

S-ROM NOILES. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Zimmer MOST Options System

Zimmer NexGen LCCK. Surgical Technique for use with LCCK 4-in-1 Instrumentation. Contact your Zimmer representative or visit us at

The information contained in this document is intended for healthcare professionals only.

The Right Choice. Exeter. total hip system

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Zimmer Segmental System. Distal Femoral Surgical Technique

Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:

Aesculap Orthopaedics Metha

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Introduction to the Bertram Hip Spacer

ABG II Modular. Anatomic Reconstruction

Aesculap Orthopaedics BiCONTACT

MDM. Surgical Technique. Modular Dual Mobility Acetabular System. Orthopaedics

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

MIS Direct Anterior Approach Surgical Protocol

Primary V40 Surgical Protocol. Exeter. total hip system

MDMTM. Surgical Technique. Modular Dual Mobility TM Acetabular System. Orthopaedics

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

Surgical procedure. METS Modular Distal Femur

Comprehensive Reverse Shoulder System

CPT 12/14 Hip System. Primary Hip Athroplasty Surgical Technique

How To Use A Phoenix Retrograde Femoral Nail

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

PROCOTYL L. Acetabular Cup System

PERIPROSTHETIC IMPLANTS

Expert LFN. Lateral Femoral Nail.

Stainless Steel Single and Dual Circulation Kits

TRIGEN TAN and FAN Intramedullary Nails

ReCap Product Rationale

The information contained in this document is intended for healthcare professionals only.

PFNA. With Augmentation Option.

Wagner Cone Prosthesis Hip Stem. Surgical Technique

P REPLACEMENT SURGERY

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Machine Screws, Dowel Pins and Hardware

Trident Acetabular System Hemispherical Surgical Protocol

The information contained in this document is intended for healthcare professionals only.

Prostalac Hip System. Surgical Technique

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Why an Exactech Hip is Right for You

NEXGEN COMPLETE KNEE SOLUTION. Epicondylar Instrumentation Surgical Technique For Legacy Posterior Stabilized Knees


Puddle Flange. FRANK Puddle Flange

ABGII Cement Free Total Hip Replacement System

Arctic Leash Instruction Manual Alaskan Products Company LLC.

DHS/DCS System. Including LCP DHS and DHS Blade.

Machine devices, jig devices

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Tool Holder Catalog INDEX ABC VDI 25 LL /Rö

CPT 12/14 HIP SYSTEM LONG STEMS. Surgical Technique for Femoral Revision

Saferand easierinstallation

Drive shaft, servicing


How To Replace A Reverse Osmosis Water Tank

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

DO NOT attempt to repair hub and wheel bearing assembly.

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Trabecular Metal Femoral Component. Surgical Technique

Industrial Strength Rocket Launcher

S4 - Top Hung Window. Outside view. Inside view. Interior frame. Exterior frame. Glazing Panel

ACL Reconstruction with Bone-Tendon-Bone Transplants Using the ENDOBUTTON CL BTB Fixation System

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

NCB Distal Femur System. Surgical Technique

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Things you need to assemble the tube actuator. Left to right. are small piece of masking tape, super glue,pen knife and small

Zimmer Trilogy IT Acetabular System

Implant Extraction Guide Module One & Two

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

CABLE SUPPORT SYSTEMS

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Wagner SL Revision Hip Stem

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Straumann Dental Implant System. Fax Order Form Collection.*

Lentur Cable System. Surgical Technique

Transcription:

Surgical technique Sagitta EVL

Sagitta EVL The range Offset 7 mm The collar neck increases by mm from the size. 1 Size L (mm) Standard Offset DP+ 1. / 0 10 6 L 0+ 1 6.. 1 16 6.6.6 10 7 1 7.. 160 0 7 16 0. 7. 6 170 1 8 7 17 1. 8. Sagitta EVL cementless Without collar Offset without collar SAGIT.EVL DP+ HA** / SAGIT.EVL 0 HA SAGIT.EVL 0 HA-D SAGIT.EVL 0 + HA SAGIT.EVL 0 + HA-D SAGIT.EVL 1 HA SAGIT.EVL 1 HA-D SAGIT.EVL HA SAGIT.EVL HA-D SAGIT.EVL HA SAGIT.EVL HA-D SAGIT.EVL HA SAGIT.EVL HA-D SAGIT.EVL HA SAGIT.EVL HA-D SAGIT.EVL 6 HA SAGIT.EVL 6 HA-D SAGIT.EVL 7 HA SAGIT.EVL 7 HA-D Standard with collar Offset with collar SAGIT.EVL DP+ HA-A** / SAGIT.EVL 0 HA-A SAGIT.EVL 0 HA-AD SAGIT.EVL 0 + HA-A SAGIT.EVL 0 + HA-AD SAGIT.EVL 1 HA-A SAGIT.EVL 1 HA-AD SAGIT.EVL HA-A SAGIT.EVL HA-AD SAGIT.EVL HA-A SAGIT.EVL HA-AD SAGIT.EVL HA-A SAGIT.EVL HA-AD SAGIT.EVL HA-A SAGIT.EVL HA-AD SAGIT.EVL 6 HA-A SAGIT.EVL 6 HA-AD SAGIT.EVL 7 HA-A SAGIT.EVL 7 HA-AD

SURGICAL TECHNIQUE Sagitta cemented Standard without collar Offset without collar SAGIT.EVL DP+ M** / SAGIT.EVL 0 M SAGIT.EVL 0 M-D SAGIT.EVL 0 + M SAGIT.EVL 0 + M-D SAGIT.EVL 1 M SAGIT.EVL 1 M-D SAGIT.EVL M SAGIT.EVL M-D SAGIT.EVL M SAGIT.EVL M-D SAGIT.EVL M SAGIT.EVL M-D SAGIT.EVL M SAGIT.EVL M-D SAGIT.EVL 6 M SAGIT.EVL 6 M-D SAGIT.EVL 7 M SAGIT.EVL 7 M-D Femoral heads Head Stainless steel Cobalt chrome Alumina medium SI./0 SCC./0 / Ø, long SI./+ SCC./+ / short SI 8/- SCC 8/- SA 8/- Ø8 medium SI 8/0 SCC 8/0 SA 8/0 long SI 8/+ SCC 8/+ SA 8/+ extra long* SI 8/+7 et SI 8/+10 / / * The extra long heads and the diameter and 6 mm heads, corresponding to a specific range of cups, are available on demand. Only use them with the stems size or more. ** DP+ stems are available on demand. Instrumentation kit N Code Name 1 RS60 0 à RS60 7 SAGITTA trial stem rasp TE60-,/0 TE60-,/+ TE60-8/- TE60-8/0 TE60-8/+ Average Ø, trial head Long Ø, trial head Short Ø8 trial head Average Ø8 trial head Long Ø8 trial head 1 COE61 COE6 Standard short trial neck (yellow) Standard long trial neck (blue) COE6 COE6 With offset short trial neck (yellow) With offset long trial neck (blue) N Code Name 1 1 IP 1 poignée IP600 Stem impactor handle Stem impactor MI- Measuring shaft 6 EI601 Stem/neck impaction tip ME60 Rasp handle 6 PPI600 Prehension pliers 7 7 FC601 Calcar milling cutter

Sagitta EVL 1 Cutting the neck of the femur The level of the cut of the femoral neck is determined in pre operative planning using X-ray templates. The anatomic landmarks are confirmed intra-operatively. The cut is at to the anatomical axis of the femur. Preparing the greater trochanter and the metaphysis The opening of the femoral canal and preparation of the greater trochanter can be initiated with a small rasp. It can be necessary to rasp the inside of the greater trochanter in order to avoid placing the broaches and implant in varus. «Femur cut» Broaching Connect the broach to the appropriate impactor and progressively impact the cancellous bone up to the neck cut. The definitive size is reached when the broach is stable in torsion and well seated.

SURGICAL TECHNIQUE Reaming for insertion of collared stem Present the powered reamer and ream over the broach in place until impingement of the reamer on the broach. This operation results in a perfect line between the femoral surface and the upper surface of the broach. The calcar reamer smoothes the surface of the calcar for insertion of stems with collar. Cutter/reamer alignment Reamer/cutter contact Trial reductions Two standard and two offset necks allow for trial reduction using the broaches, and to determine the centre of rotation.the head and neck assembly allows for a trial reduction. Retention Mistake proof Sizes 0 0+ 1 6 7 Standard stems Short yellow neck Long blue neck Offset stems Short yellow neck Long blue neck

Sagitta EVL 6 Definitive stem implantation Cemented version The stem is introduced progressively into the cement mantle by hand pressure using the constrained impactor. This impactor when seated in the stem, allows adjustment of orientation, anteversion can be visualised with the positioning rod. Holding handle Cementless version The stem is placed into the femoral canal. Final impaction is achieved when the stem coating is flush with the level of the cut. Impaction marking 7 Femoral heads Trials on the implant It is possible to carry out trial reductions with trial heads. Definitive head assembly Clean and dry the morse taper. Place the definitive head on the morse taper, and impact it with a sharp hammer blow on the impactor, which is also used to reduce the articulation. Head Impactor 6

SURGICAL TECHNIQUE Optional instruments Head extraction Place the extraction connector over the implant head and screw down until in contact on the head. Connect the slap hammer to the end of the connector and gradually slap the head out. Stem extraction After removing the head, connect the stem connector to the male taper on the collar. This connection must be securely fastened by tightening the lateral nut with the end of the slap hammer. The position of the lateral screw can be reversed according to the side on which the operation is performed. *The extraction kit is available on demand. It contains: 1 slap hammer 1 head extraction connector 1 stem extraction connector Cleaning the broach handle To clean the broach handle properly, pull the insert out of the main body. Insert Handle (body) 7

- 8 avenue des Bruyères - 691 Décines Cedex - FRANCE Tél. + 7 0 60 10 - Fax. + 7 0 19 18 - serf@serf.fr www.serf-dediennesante.com 09 - SAGITTA EVL EN - Edition N -01 - SFRADT070011A ISO 18