Mold Alert... Operation Manual P0270



Similar documents
IR Repeater. Operation Manual P8620

Intelli-Time Alarm Clock model 13027

Atomic Alarm Clock model 13131W2

WS-9005TWC 915MHz WIRELESS RAIN GAUGE INSTRUCTION MANUAL

INSTRUCTION MANUAL DTH Fax: (503)

Alarm Clock USER GUIDE

el-720 Carbon Dioxide Gas Leak Detector User s Guide

EzFlex Combustible Gas Leak Detector Model EZ40

Wireless Indoor/ Outdoor Thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Temperature Humidity Meter

Thermometer model 00754

Ultrasonic Distance Meter. Operation Manual

Microwave Meter. Instruction Manual

Model: Manual DC: WIRELESS COLOR FORECAST STATION

High Temperature InfraRed Thermometer with Laser Pointer

Weather Radio Alarm Clock

Dual Laser InfraRed (IR) Thermometer with Color Alert

Atomic Projection Alarm Clock model 13021

Dual-Cool Notebook Cooler Pad. User s Manual

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

User Manual (English)

Dual Laser InfraRed (IR) Thermometer

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

How To Use The Visifault Visual Fault Locator

Dual Laser InfraRed (IR) Thermometer

Optical Wireless Mouse. User s Manual

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Touchless Forehead Thermometer

Alarm Clock USER GUIDE

Atomic Dual Alarm Clock models / 13035

AM/FM PLL Clock/Table Radio

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand

Installation Instructions

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

VK-250 WARRANTY REGISTRATION FORM

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Bottom Loading Water Dispenser

Laser Wireless Rechargeable Mouse. User s Manual

Advantium 2 Plus Alarm

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

PixController, Inc. Wireless Digital PIR Sensor

WIRELESS WEATHER STATION Model USER'S INSTRUCTIONS

Light Meter (Foot Candles)

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

Professional Thermohygrometer

Operating Manual Remote Cost Control Monitor

Atomic Alarm Clock Instruction Manual

Temperature, Humidity & Dew Point Chart Recorder

VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Mini Power Bank and Charger

Ceiling Mount Air Handler Manual

Owner s Guide. ca6554

CABLE MODEM QUICK START

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD

Wolverine Data PASS Portable Scanner User Manual V1.0

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Get Me Cool Now Portable Air Conditioner User s Manual

Automatic Wrist Blood Pressure Monitor with

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

MEMO ALARM CLOCK Operating Manual

BEL-AIR WIRELESS THERMO-HYGROMETER Instructions manual Cat. No IT

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

Contents. Product Code Page 1

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

USER S MANUAL HSC-24A

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Owner s Manual & Safety Instructions

USB Port Hub with USB Power Cable. User s Manual

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Conserve Insight Energy Use Monitor. User Guide

Operators Manual SOIL COMPACTION TESTER

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

900 MHz Lightweight Wireless Stereo Headphones


Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

DSM155 Digital LED Light Meter User s Manual DSM155

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

AD-01 Slave Auto Dialer. Owner s Manual

ROTOR LOADER OWNER S MANUAL

15 Digital Photo Frame Instructional Manual

2GB MP3 Player USER GUIDE

7 Digital Photo Frame Instructional Manual

Transcription:

Mold Alert... Operation Manual P0270

introduction Congratulations on your purchase of the P0270 Mold Alert! Mold is as old as the Earth and it s everywhere. Under the right set of conditions, it can actually start to grow inside your home. Some types of mold even contain mycotoxins (toxins produced by fungus-type organisms) which can be hazardous to your health. Mold can grow at humidity levels over 65%. If you keep the relative humidity in your home below 50%, mold growth can be inhibited. The Mold Alert Thermo-Hygrometer allows you to monitor some of the key factors in the home that can lead to mold, dust mites, and bacteria. features Audible and Visual alarm function to indicate risk of mold Room Temperature Indoor Relative Air Humidity Dew Point Maximum and Minimum values On/Off switch for audio alarm overview The interaction of temperature and air humidity: Cold air absorbs little or no moisture. When this air enters living areas it becomes warmer and can then absorb much more water vapor. This interdependency of temperature and relative humidity is expressed by means of the dew-point. If the measuring unit indicates an air temperature of 68 F and a relative humidity of 65%, then the dew-point temperature will be 56 F. What does this mean? That the air, in your bedroom for instance, will condense and form water droplets on surfaces that are cooler than 56 F, and these damp areas may lead to mold.

overview If the air is at a relative humidity of 40%, then the dew-point temperature is only 43 F. The walls and ceilings would therefore have to be significantly colder for the air to reach its dew-point and for water droplets to form. How to achieve the correct temperature and air humidity: Tips for active heating and ventilation: Check the dew-point! Surfaces of walls should not fall below a temperature of 59 F. Avoid shutting off the heat completely when leaving the house for extended periods of time. Ventilate in all weather conditions, even if it s raining. Open the windows for a short time to air the room. A partially opened window does not have the desired effect, wastes heating energy and can even promote the formation of mold. If the room air is too dry, particularly in the winter, then electrical air humidifiers are recommended, since airing at low temperatures will tend to decrease the humidity further. When airing a room, a few minutes should be sufficient. Check the value indicated on your Mold Alert thermo-hygrometer. startup 1. Select F/ C and place the audio alarm switch on the back of the unit in on mode. 2. Slide off front compartment and install 2 batteries 1.5V AA. Once these are in place, the frowning face on the display will light up briefly and the alarm will sound for 2 seconds. 3. Replace battery compartment cover. 4. Remove the protection film on the display. 5. The unit is now ready to use.

set up Suggestions for Placement of the Unit There is an opening on the back of the unit, which allows it to be easily hung from the wall. In addition, a base is provided for the unit to be placed on any surface in a standing position. Since the humidity level within rooms can vary greatly, the Mold Alert should be placed in an area most likely subject to mold growth. Problem areas are often basements, closets, surfaces near windows and exterior walls. Anywhere in a home that is damp or has suffered from water damage is also a prime location for mold growth. reading the display Three values of measurement are displayed simultaneously. The left column shows the indoor relative humidity (%), the middle column indicates room temperature ( C/ F), and the right column displays the dew point (Td). The temperature can be displayed either in Fahrenheit or Celsius by adjusting the C/ F switch on the back of the unit. The audio alarm can be activated using the Al On / Al Off switch on the back of the unit. Risk of mold formation occurs at humidity levels exceeding 65%. When this point is reached, the frowning face icon on the display will light up. If the audio alarm is activated, it will also sound. An arrow pointing up will be flashing next to the relative humidity display. The audio alarm can be silenced by pressing any button. When humidity levels are reduced below 65% the frowning face icon will stop flashing and the alarm (if activated) will be silenced. The arrow pointing up display will persist to indicate high humidity levels have occured in the past. The arrow pointing up display can be reset by pressing any button.

Minimum/Maximum Temperatures The highest temperature and humidity values since the last reset can be displayed by pressing the Min/Max button on the right side of the Mold Alert. The lowest temperature and humidity levels since the last reset, can be displayed by pressing the Min/Max button a second time. The current values can be shown again by pressing the Min/Max button a third time. The reset key is located above the Min/Max button on the right side of the unit and is used to reset Min/Max values when they are displayed. If humidity levels are high To lower humidity, you can open windows or put a fan in the area to better ventilate it, which may prevent mold growth. If there is moisture or a water leak, mold growth may have occurred. This mold can cause health problems and the sooner you detect it, the more likely you are to be able to control it. If you suspect that you have a mold problem, and the remedies outlined in this manual prove to be insufficient, please contact a mold control professional. If humidity levels are low enough The area in which you have placed the unit is safe from mold growth, however the Mold Alert thermo-hygrometer is a useful product to have in any home due to its accurate measurements of temperature, dew point, and humidity. maintenance Do not expose the Mold Alert to extreme temperatures, vibration, or shock. Clean the unit with a soft damp cloth. Do not use solvents or scouring agents. Replace batteries if the unit stops working.

specifications Model: P0270 Relative Humidity: 1% to 99% RH, accuracy ±5% Room Temperature: 14 F to 140 F, accuracy ±1% Alarm Trigger Point: 65% humidity triggers audio/visual alarm Display: User selectable F or C, Min/Max values Batteries: 2 x AA (not included) Weight: 4.8 oz. Dimensions: 3 3/4"H x 3 3/4"W x 2 1/2"D (Specifications subject to change without notice) The Swiss precision hygrotech sensor allows our Mold Alert to give accurate measurements when checking a room s ambient condition.

P3 INTERNATIONAL CORPORATION LIMITED WARRANTY P3 INTERNATIONAL CORPORATION ( P3 ) warrants to the original retail purchaser only, that its product is free from defects in material or workmanship under the condition of normal use and service for a period of six (6) months from the date of purchase. In the event that a defect, malfunction or failure occurs or is discovered during the warranty period, P3 will repair or replace at its option the product or component part(s) which shall appear in the reasonable judgment of P3 to be defective or not to factory specifications. A product requiring service is to be returned to P3 along with the sales receipt or other proof of purchase acceptable to P3 and a statement describing the defect or malfunction. All transportation costs shall be borne by the owner and the risk of loss shall be upon the party initiating the transportation. All items repaired or replaced thereunder shall be subjected to the same limited warranty for a period of six (6) months from the day P3 ships the repaired or replaced product. The warranty does not apply to any product that has been subject to misuse, tampering, neglect, or accident or as a result of unauthorized alterations or repairs to the product. This warranty is void if the serial number (if any) has been removed, altered, or defaced. This warranty is in lieu of all warranties expressed or implied, including the implied warranties of merchantability and fitness for a particular purpose which are expressly excluded or disclaimed. P3 shall not be responsible for consequential, incidental or other damages, and P3 expressly excludes and disclaims liability for any damages resulting from the use, operation, improper application, malfunction or defeat of any P3 product covered by this limited warranty. P3 s obligation is strictly and exclusively limited to the replacement or repair of any defective product or component part(s). Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. P3 does not assume or authorize anyone to assume for it any other obligation whatsoever. Some states do not allow limitation on how long an implied warranty lasts, so the above limitations may not apply to you. It is the owner/user's responsibility to comply with local, state, or federal regulations, if any, that may pertain to P3 products or their use. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. If you experience difficulty in the operation of your unit, or if your unit requires repair please contact: P3 INTERNATIONAL CORPORATION TECHNICAL SUPPORT Tel: 212-741-7289 Fax: 212-741-2288 Email: techsupport@p3international.com 2007 P3 International Corporation Rev. 1007