StepWatch Step Activity Monitor US Patent # 5,485,402



Similar documents
Heikki Uustal, MD Prosthetic/Orthotic Team JFK-Johnson Rehab Institute Edison, NJ

Gait recovery pattern of unilateral lower limb amputees during rehabilitation

There are more than 50 models of prosthetic feet available today. Some are. designed for special tasks such as walking, dancing, cycling, golfing,

DROP FOOT AND TREATMENTS YOUNGMEE PARK

Paul R. Langer, D.P.M. Twin Cities Orthopedics th Avenue South #505 Minneapolis, MN

Off the shelf orthoses are commonly used to treat conditions such as foot and ankle sprains, minor shoulder injuries and to provide back support.

RX: Custom Thermoplastic AFO Compliance Documentation

WALKING BOOTS WALKING BOOTS. AFO s: Provider vs Prescriber? Provider. Prescriber

Inpatient Rehabilitation Facilities (IRFs) [Preauthorization Required]

Rehabilitation Services Specialty Outpatient Clinics

No two knees are alike. That s why we personalize your surgery just for you. Zimmer Patient Specific Instruments. For Knee Replacement Surgery

Total Hip Joint Replacement. A Patient s Guide

CUSTOM ORTHOTICS/SHOES FAQ AND GLOSSARY

Preferences for rehabilitation services among women with major limb amputations

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

Orthopaedic Issues in Adults with CP: If I Knew Then, What I Know Now

Manufacturing Technology, Inc.

Osteoarthritis progresses slowly and the pain and stiffness it causes worsens over time.

ELLEN BEATTY, M.D. CURRICULUM VITAE PERSONAL: BUSINESS ADDRESS: Florida Orthopaedic Institute N. Telecom Parkway. Temple Terrace, Florida 33637

The Use of the Lokomat System in Clinical Research

.org. Plantar Fasciitis and Bone Spurs. Anatomy. Cause

Calcaneus (Heel Bone) Fractures

Q-Scan UniComm V2.0. User Manual. Q-Scan People Counters

Spirodoc. 3D Laboratory for respiratory analysis two functional modes: doctor and patient. Four devices in one. Spirometer with Touch Screen display

Basic gait parameters : Reference data for normal subjects, years of age

USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Transtibial (Below Knee) Residual Limb Edema and Shape Management Recommendations: INPATIENT REHABILITATION

SAM KARAS ACUTE REHABILITATION CENTER

ROGER E. MURKEN, MD. Curriculum Vitae. OrthoColorado Hospital W. 2 nd Place Lakewood, CO 80228

Dr. Khaled E. Ayad Alrehab City, Cairo Egypt Cell phone:

Extended Stay Recovery Centers: Enhancing the Patient Experience and Lowering Healthcare Costs

Validation of Basis Science Advanced Sleep Analysis

Amputation Rehabilitation Center

Setup your heart rate zones and register for product updates QUICK START GUIDE

Rehab Science & Technology Update

CODE Webinar 5. Documentation tips for justifying elevated vacuum. Molly McCoy, L/CPO McCoy Consulting, LLC CODE SPS

How To Become A Physio And Rehabilitation Medicine Specialist

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Heel pain and Plantar fasciitis

The Royal Military College - Duntroon Army Officer Selection Board Bridging Period Conditioning Program

HHRD S INTERVENTATIONS Physical Rehabilitation Program

The VA Transitions from Traditional Prosthetics to Personal Bionics

HANDE ARGUNSAH BAYRAM Ph.D.

POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION POSTOPERATIVE REHABILITATION PROTOCOL

Total Knee Replacement Surgery

User Guide CentrePoint Study Admin

Total Hip Replacement

PLANTAR FASCITIS (Heel Spur Syndrome)

Measurement of free living activity and its application

Sleep and Brain Injury

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility 19 April 2011

Rheumatoid Arthritis of the Foot and Ankle

Rehabilitation Guidelines for Patellar Tendon and Quadriceps Tendon Repair

LOW COST PROSTHETIC DEVICE FOR TOE PART

New thermometers and accessories to grow your business

Orthopaedic In-Training Examination User Manual Step-by-Step for PC

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

INTERACTIVE WHITE BOARD MANUAL

HD Security Camera. No cords. No wires. No worries. Features. Motion Alerts Receive push notifications and s if anything moves

Smart Home Security Camera. No cords. No wires. No worries. Features. Motion Alerts Receive push notifications and s if anything moves

How To Cover Occupational Therapy

Neuromechanical Redundancy for Gait Compensation in Transtibial Amputees. Kinsey Herrin, B.S. Advisor: Young-Hui Chang, Ph.D.

Plantar Fasciitis Information Leaflet. Maneesh Bhatia. Consultant Orthopaedic Surgeon

Frequently Asked Questions

The Insall Scott Kelly Center for Orthopaedics and Sports Medicine 210 East 64th Street, 4 th Floor, New York, NY 10065

USB Smart Power Sensor

Why an Exactech Hip is Right for You

POLARIS OPTICAL TRACKING SYSTEMS

Weather Capture Software Guide Version 1.4 Revision: June

Member, National Honor Society, President, National Honor Society,

Foot and Ankle Conditioning Program. Purpose of Program

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

Pain and tissue-interface pressures during spineboard immobilization.

Clinical Care Program

DataView DVTH Data Logger for Temperature and Humidity

Preparing Log-ic 360 USB Loggers for Use

Knee Arthroscopy Exercise Programme

Movement artifacts electrical noise caused by the movement of the sensor surface with respect to the skin surface

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility

Arlo Wire-free HD Camera Security System

USER MANUAL V5.0 ST100

University Rehabilitation Institute Republic of Slovenia. Helena Burger, Metka Teržan University Rehabilitation Institute, Ljubljana, Slovenia

.org. Posterior Tibial Tendon Dysfunction. Anatomy. Cause. Symptoms

MCGHealth Orthopaedic Center

treatment of varicose and spider veins patient information SAMPLE a publication by advancing vein care

PHYSICAL THERAPY INTERVENTION WITH ALS

GALLAND/KIRBY INTERVAL DISTANCE RUNNING REHABILITATION PROGRAM

TOTAL HIP REPLACEMENT

Neck Injuries and Disorders

Robotic-Arm Assisted Surgery

T R O U B L E S H O O T I N G T I P S

Before Surgery You will likely be asked to see your family physician or an internal medicine doctor for a thorough medical evaluation.

Anterior Approach. to Hip Replacement Surgery

Knee Conditioning Program. Purpose of Program

Demystifying ICD 10. Beyond the Hype. What Therapists Should Know about ICD 10.

INSTALLATION GUIDE ENTERPRISE DYNAMICS 9.0

Transcription:

StepWatch

A tool for accurately, objectively, and easily measuring long-term ambulatory activity The StepWatch step activity monitor is a patented, highly accurate, unobtrusive instrument worn on the ankle (Figure 1). Consisting of a sensor, electronics and battery molded into a urethane case, the StepWatch is a very durable, sealed, waterproof device. It neither requires nor allows any adjustment or maintenance by the subject. The StepWatch measures 6.5 cm long x 5 cm wide x 1.5 cm thick and weighs 65 grams (2.3 oz). The inner surface of the case is curved. Two elastic attachment straps insure that the monitor remains securely attached to the ankle without irritating the skin or damaging the cosmetic cover of a prosthesis. Alternatively, the straps can be removed and the monitor worn in a soft cotton/lycra sleeve at the ankle. Figure 1. StepWatch The StepWatch records step counts in short, adjustable time intervals over extended monitoring periods. For example, the StepWatch is normally used to collect one minute time intervals for two to four weeks. This allows patterns of activity and rest to be measured, as well as overall activity (Figure 2). 100 walk to bus walk to bus 80 total steps = 8810 walk to work errands walk home 60 Steps/Minute jogging 40 office work housework 20 desk work 0 0 2 4 6 8 10 12 14 16 18 20 22 24 Time (hour of day) Figure 2. Twenty-four hours of StepWatch data with specific activities detailed

Detailed profiles can be generated relating to issues such as the intensity and duration of peak activity, the ability of a subject to sustain a given level of activity, and the relationship between activity and rest patterns. These can give insight into a subject's real world ambulatory function that cannot be obtained through the use of a simple pedometer or through time consuming and expensive gait laboratory testing. StepWatch accuracy has consistently been found to exceed 99% across a wide range of subjects. (For specifics on accuracy, see manuscripts 1,2, 3, 6, 7, 9 of attached publications list.) In addition, because subjects are only required to wear the StepWatch, the nuisance of activity logs and the questions of accuracy and subjectivity inherent to questionnaires are avoided. StepWatch Operation Setting Up The Monitor For Use And Retrieving Data The StepWatch is programmed and downloaded using a computer connected to a docking station (Figure 3). The dock communicates with the StepWatch via infrared light. To program the StepWatch, basic performance and sensitivity settings are entered on the computer screen. A summary of settings is provided later in this document. The StepWatch's sensitivity can be optimized for a subject's gait characteristics, although a generic setting for a slow, normal or fast ambulator is generally sufficient to attain highly accurate data. If desired, the effectiveness of the chosen settings can be easily verified during a short test trial. Figure 3. StepWatch on Docking Station

Some Past and Current Investigations The StepWatch has many possible applications in medicine. For example, it can be used to monitor the effectiveness of rehabilitation programs, or to determine whether a treatment allows or motivates the patient to walk more. Studies completed or currently in progress may provide context with regard to potential clinical and research applications of the StepWatch. These studies include: 1) Description of subject populations: A) Levels and patterns of activity of males with advanced diabetes. B) Activity levels in children with and without physical disability C) Wandering behavior with Alzheimer's disease D) Activity of horses in stalls (for equine fracture management) 2) Measurement of Outcome A) Dynamic elastic response foot vs. rigid keel foot in lower limb prostheses B) Elastomeric suspension liner vs. traditional foam liner for trans-tibial prostheses C) Ambulatory activity before and after elective lower limb amputation D) Effect of exercise program on activity of Alzheimer's patients E) Effect of exercise program on activity of elderly women following hip fracture F) Effect of exercise program on recovery of stroke patients G) Effect of total hip replacement on ambulatory activity H) Effect of cartilage replacement on activity in a sheep model and in humans I) Effect of spinal implants on ambulatory activity 3) Basic and Clinical Science A) Association of total hip prosthesis wear rates with ambulatory activity (Awarded the Hip Society's prestigious Charnley Award (2000) for important advances in the management of hip disorders. Study by the authors of manuscript 2 in attached publications list.) B) Relationship between cognitive function and physical performance after stroke C) Relationship between activity levels in children and obesity D) Estimation of habitual plantar pressures from step and standing activity E) Tracking of recovery following lower limb amputation F) Relationship between self-selected walking velocity and ambulatory activity level

System Costs (Pricing Subject to change without notice) Component Cost StepWatch step activity monitor $800 Computer Interface Dock Communication Software Software Support For 1 year For current pricing and availability contact: Prosthetics Research Study 675 South Lane Street, Suite 100 Seattle, WA 98104 Telephone: (206) 903-8136 Fax: (206) 903-8141 Email: info@prs-research.org World Wide Web: www.prs-research.org $2,500 Computer Requirements and Software Development of new software to allow communications, data viewing, filtering and basic analysis is currently nearing completion. This software is both PC and Mac compatible, and simplifies the process of programming and downloading the StepWatch. It is available for purchase in its current betaversion. Updates will be supplied free of charge until the software reaches its final release form. A computer with at least 16 MB RAM and a processor speed of at least 50 MHz is needed. The machine must have a working serial or USB port.

Summary of StepWatch programmable settings Setting Type Description Start Time Recording Date and time to begin recording - can be immediately or in the future. Interval Recording How often data are recorded (i.e. sampling period). This setting also determines the maximum length of the monitoring period. Cadence Sensitivity Determined by the typical step rate of the subject (fast, medium, slow). Motion Sensitivity The character of leg motion in the subject's gait (gentle, normal, vigorous). Days to Record Recording Sets date and time to end monitoring. (A "maximum" check box allows specifying will continue until the memory is full.) Count Scaling Recording Enable if step count per interval is LED Flashes Notes Accuracy Testing Recordkeeping expected to exceed 255. The number of times (0 to 255) the StepWatch's indicator light will blink. The light blinks each time a step is detected. Used to verify that monitor is set accurately. Does not blink during normal use. Text (80 characters) which is stored in the StepWatch memory for uses such as subject or trial identification.. Threshold Sensitivity The sensitivity of the sensor to leg motion. This setting is only changed from its default if the desired sensitivity cannot be achieved by adjusting the "Motion" setting.

Some publications involving the StepWatch (most available upon request) 1. Coleman KL, Smith DG, Boone DA, Joseph AW, del Aguila MA: Step Activity Monitor: Long- Term Continuous Recording of Ambulatory Function, J Rehabil Res Dev, Vol 36, No1, 8-18, 1999. [on-line URL: http://www.vard.org/jour/99/36/1/colem361.htm] 2. Shepherd EF, Toloza E, McClung CD, Schmalzried TP: Step Activity Monitor: Increased Accuracy in Quantifying Ambulatory Activity, J Orthop Res, Vol 17, No5, 703-708, 1999. [This is a reporting on a study conducted with total hip replacement patients. Reprints may be requested from T. Schmalzried at Joint Replacement Institute, 2400 S. Flower St., Los Angeles, CA 90007, USA E-mail: jri_oh@compuserve.com] 3. McDuffee LA, Stover SM, Coleman K: Limb Loading Activity of Adult Horses Confined to Box Stalls in an Equine Hospital Barn, Am J Vet Res, Vol 61, No3, 234-237, 2000. 4. Smith DG, Boone DA, Coleman K, Legro M: Outcome Assessment in Prosthetics and Orthotics. In: Berke GM, Langdon SD, eds. Proceedings of the 23rd AAOP Annual Meeting & Scientific Symposium, San Francisco, CA, 27-30, March 12-15, 1997. 5. Smith DG, Coleman KL, del Aguila MA, Boone DA: Functional Ambulation of Geriatric Male Diabetics: Correlation of Step Count Based Gait Assessment with the SF-36. Proceedings of the 65th Annual Meeting of the American Academy of Orthopaedic Surgeons, New Orleans, LA, March 19-23, 1998. 6. Coleman KL, del Aguila MA, Boone DA, Smith DG: Self-Selected Walking Velocity as a Measure of Function: Relationship to Real World Ambulatory Activity of Diabetics. In: Soede M, Verbout AJ, Swart M, eds. IXth World Congress of the International Society for Prosthetics and Orthotics, Amsterdam, The Netherlands, 371-373, June 28-July 3, 1998. 7. Coleman KL, Boone DA, Smith DG, Mathews DE, Laing LS: Functional Outcome Assessment Using Objective Measures of Patient Satisfaction and Gait Activity: A Comparison of 2 Feet. In: Soede M, Verbout AJ, Swart M, eds. IXth World Congress of the International Society for Prosthetics and Orthotics, Amsterdam, The Netherlands, 690-692, June 28-July 3, 1998. 8. Smith DG, Coleman KL, Boone DA: Improved Activity Following Elective Trans-Tibial Amputation for Pain: Outcome Assessment by Long-Term Activity Monitoring (A Case Report). In: Soede M, Verbout AJ, Swart M, eds. IXth World Congress of the International Society for Prosthetics and Orthotics, Amsterdam, The Netherlands, 728-730, June 28-July 3, 1998. 9. Coleman KL, Boone DA, Laing LS, Mathews DE, Czerniecki JM, Sangeorzan BJ: Quantification of Prosthetic Treatment Outcomes - Elastomeric Liner & Locking Pin Suspension vs Pelite Liner & Neoprene Sleeve Suspension. Second National Department of Veterans Affairs Rehabilitaiton Research and Development Conference Proceedings, Arlington, VA,100, February 20-22, 2000. 10. Macko RF, Heuber E, Shaughnessy M, Boone DA, Coleman KL, Smith GV, Silver KHC, Gardner AW: Portable Ambulatory and Activity Monitoring in Hemiparetic Stroke Patients. Second National Department of Veterans Affairs Rehabilitation Research and Development Conference Proceedings, Arlington, VA, 208, February 20-22, 2000.