Diesel Generator Set Model DFMB 60 Hz



Similar documents
Diesel Generator Set Model DFHC 60 Hz

How To Control A Power Command Powerplant

Diesel Generator Set Model DGDK 60 Hz

Spark-ignited generator set

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SETS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

Diesel Engine Driven Generators Page 1 of 6

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Diesel Generating Set

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

C18 ACERT Fire Pump Tier bkw/ rpm

3516 Industrial Engine

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Annex-A TECHNICAL SPECIFICATION

A Single Source for all Power System Solutions

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

PM734F - Technical Data Sheet Winding 28

How To Use A Cat Diesel Engine

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

C18 Diesel Oilfield Generator Set

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

Magnum Mobile Generator MMG55 Specifications

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

PowerCommand 1.1 control system

Bill of Materials Re: 2250KW. Item Description Qty

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

BCI184E - Technical Data Sheet

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Technical Specification. Generating Set with Waukesha engine burning natural gas

Digital generator set 1302 control kit

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

Atlas Copco Generators

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

The reliability of the grid

PowerCommand 3201 digital generator set control

Diesel generator set C22D5T series

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

APS100 Rental Generator Set Specification

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

IGSA POWER GENERATION SYSTEMS

PowerCommand Paralleling System Digital MasterControl

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

GTEC transfer switch open transition

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Commercial Gas Furnace Upflow

LOAD BANK TESTING PROCEDURE

Power Generation. Power Control PCL System Generator Set Control

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

PowerCommand iwatch 100

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Transfer Equipment Controls

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

300 Series PA Pump and Cooler Assemblies

T-016: Paralleling Application Manual

Marine Generating Sets 3.7 to 50 kva

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Cahier technique no. 196

CUKUROVA GENERATOR SYSTEMS

Fire Pump Plan Review March 2010

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

STAMFORD Product Guide

Single-Phase AC Synchronous Generator

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Transcription:

Diesel Generator Set Model DFMB 60 Hz 1500 kw, 1875 kva Standby 1250 kw, 1563 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation system providing optimum performance, reliability, and versatility for stationary standby or prime power applications. A primary feature of the DF GenSet is strong motor-starting capability and fast recovery from transient load changes. The torque-matched system includes a heavy-duty Cummins 4- cycle diesel engine, an AC alternator with high motor-starting kva capacity, and an electronic voltage regulator with threephase sensing for precise regulation under steady-state or transient loads. The DF GenSet accepts 100% of the nameplate standby rating in one step, in compliance with NFPA110 requirements. The standard PowerCommand digital electronic control is an integrated system that combines engine and alternator controls for high reliability and optimum GenSet performance. Optional coolant heaters improve starting in extreme operating conditions. A wide range of options, accessories, and services are available, allowing configuration to your specific power generation needs. Every production unit is factory tested at rated load and power factor. This testing includes demonstration of rated power and single-step rated load pickup. Cummins Power Generation manufacturing facilities are registered to ISO9001 quality standards emphasizing our commitment to high quality in the design, manufacture, and support of our products. The generator set is CSA certified, and the PowerCommand control is UL508 listed. All Cummins Power Generation systems are backed by a comprehensive warranty program and supported by a worldwide network of 170 distributors and service branches to assist you with warranty, service, parts, and planned maintenance support. Features UL Listed Generator Set - The complete generator set assembly is available Listed to UL2200. Cummins Heavy-Duty Engine - Rugged 4-cycle industrial diesel delivers reliable power, low emissions, and fast response to load changes. Permanent Magnet Generator (PMG) - Offers enhanced motor starting and fault clearing short circuit capability. Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing short-circuit capability, and class H insulation. Control System - The PowerCommand electronic control is standard equipment and provides total genset system integration, including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, AmpSentry TM protection, output metering, autoshutdown at fault detection, and NFPA 110 compliance. Cooling System - Provides reliable running at rated power in ambient temperatures through 50 o C. Structural Steel Skid Base - Robust skid base supports the engine, alternator, and radiator. E-Coat Finish - Dual electro-deposition paint system provides high resistance to scratches, corrosion, or fading. Certifications - Generator sets are designed, manufactured, tested, and certified to relevant UL, NFPA, ISO, IEC, and CSA standards. Warranty and Service - Backed by a comprehensive warranty and world wide distributor network.

Generator Set The general specifications provide representative configuration details. Consult the outline drawing for installation design. Specifications General See outline drawing 500-2966 for installation design specifications. Unit Width, in (mm) 89.6 (2277) Unit Height, in (mm) 98.7 (2507) Unit Length, in (mm) 222.5 (5652) Unit Dry Weight, lb (kg) 24200 (10977) Unit Wet Weight, lb (kg) 25470 (11553) Rated Speed, rpm 1800 Voltage Regulation, No Load to Full Load ±0.5% Random Voltage Variation ±0.5% Frequency Regulation Isochronous Random Frequency Variation ±0.25% Radio Frequency Interference IEC 801.2, Level 4 Electrostatic Discharge IEC 801.3, Level 3 Radiated Susceptibility IEC 801.4, Level 4 Electrical Fast Transients IEC 801.5, Level 5 Voltage Surge Immunity MIL STD 461C, Part 9 Radiated Emissions (EMI) Cooling Standby Prime Fan Load, HP (kw) 75.0 (56.0) 75.0 (56.0) Coolant Capacity with radiator, US Gal (L) 102.0 (386.1) 102.0 (386.1) Coolant Flow Rate, Gal/min (L/min) 535.0 (2025.0) 535.0 (2025.0) Heat Rejection To Coolant, Btu/min (MJ/min) 55500.0 (58.8) 46375.0 (49.2) Heat Radiated To Room, Btu/min (MJ/min) 16930.0 (17.9) 14320.0 (15.2) Maximum Coolant Friction Head, psi (kpa) 15.0 (103.4) 15.0 (103.4) Maximum Coolant Static Head, ft (m) 60.0 (18.3) 60.0 (18.3) Air Combustion Air, scfm (m 3 /min) 4100.0 (116.0) 3300.0 (93.4) Alternator Cooling Air, scfm (m 3 /min) 6720.0 (190.2) 6720.0 (190.2) Radiator Cooling Air, scfm (m 3 /min) 68000.0 (1924.4) 68000.0 (1924.4) Max. Static Restriction, in H 2O (Pa) 0.5 (124.5) 0.5 (124.5) Rating Definitions Standby Rating based on: Applicable for supplying emergency power for the duration of normal power interruption. No sustained overload capability is available for this rating. (Equivalent to Fuel Stop Power in accordance with ISO3046, AS2789, DIN6271 and BS5514). Nominally rated. Prime (Unlimited Running Time) Rating based on: Applicable for supplying power in lieu of commercially purchased power. Prime power is the maximum power available at a variable load for an unlimited number of hours. A 10% overload capability is available for limited time. (Equivalent to Prime Power in accordance with ISO8528 and Overload Power in accordance with ISO3046, AS2789, DIN6271, and BS5514). This rating is not applicable to all generator set models. Base Load (Continuous) Rating based on: Applicable for supplying power continuously to a constant load up to the full output rating for unlimited hours. No sustained overload capability is available for this rating. Consult authorized distributor for rating. (Equivalent to Continuous Power in accordance with ISO8528, ISO3046, AS2789, DIN6271, and BS5514). This rating is not applicable to all generator set models. Site Derating Factors Rated power available up to 4000 ft (1220 m) at ambient temperatures up to 104 F (40 C). Above 4000 ft (1220 m), derate at 4% per 1000 ft (305 m) and 1% per 10 F (2% per 11 C) above 104 F (40 C).

Engine Cummins heavy duty diesel engines use advanced combustion technology for reliable and stable power, low emissions, and fast response to sudden load changes. Electronic governing provides precise speed regulation, especially useful for applications requiring constant (isochronous) frequency regulation such as Uninterruptible Power Supply (UPS) systems, non-linear loads, or sensitive electronic loads. Optional coolant heaters are recommended for all emergency standby installations or for any application requiring fast load acceptance after start-up. Specifications Engine Base Engine Cummins Model KTTA50-G2, Series Turbocharged and Aftercooled, diesel-fueled Displacement in 3 (L) 3067.0 (50.3) Overspeed Limit, rpm 2100 ±50 Regenerative Power, kw 168.00 Cylinder Block Configuration Cast iron, 60º V 16 cylinder Cranking Current 1280 amps at ambient temperature of 32 F (0 C) Battery Charging Alternator 45 amps Starting Voltage 24-volt, negative ground Lube Oil Filter Types Five spin-on, full flow Standard Cooling System 122 o F (50 o C) ambient radiator Power Output Standby Prime Gross Engine Power Output, bhp (kwm) 2220.0 (1656.1) 1855.0 (1383.8) BMEP at Rated Load, psi (kpa) 313.0 (2158.1) 263.0 (1813.3) Bore, in. (mm) 6.25 (158.8) 6.25 (158.8) Stroke, in. (mm) 6.25 (158.8) 6.25 (158.8) Piston Speed, ft/min (m/s) 1875.0 (9.5) 1875.0 (9.5) Compression Ratio 13.9:1 13.9:1 Lube Oil Capacity, qt. (L) 160.0 (151.4) 151.0 (142.9) Fuel Flow Maximum Fuel Flow w/c180, US Gal/hr (L/hr) 193.0 (730.5) 193.0 (730.5) Maximum Fuel Flow w/c174, US Gal/hr (L/hr) 260.0 (984.1) 260.0 (984.1) Maximum Inlet Restriction, in. Hg (mm Hg) 4.0 (101.6) 4.0 (101.6) Maximum Return Restriction, in. Hg (mm Hg) 6.5 (165.1) 6.5 (165.1) Air Cleaner Maximum Air Cleaner Restriction, in. H 2O (kpa) 25.0 (6.2) 25.0 (6.2) Exhaust Exhaust Flow at Rated Load, cfm (m 3 /min) 10505.0 (297.3) 8330.0 (235.7) Exhaust Temperature, o F ( o C) 870.0 (465.6) 850.0 (454.4) Max Back Pressure, in. H 2O (kpa) 41.0 (10.2) 41.0 (10.2) Fuel System Direct injection, number 2 diesel fuel, fuel filter; automatic electric fuel shutoff Fuel Consumption Standby Prime 60 Hz Ratings, kw (kva) 1500 (1875) 1250 (1563) Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full US 27.7 54.2 78.5 103.3 24.2 46.2 66.5 86.9 Gal/hr L/hr 105 205 297 391 92 175 252 329

Alternator Several alternators are available for application flexibility based on the required motor-starting kva and other requirements. Larger alternator sizes have lower temperature rise for longer life of the alternator insulation system. In addition, larger alternator sizes can provide a cost-effective use of engine power in across-the-line motor-starting applications and can be used to minimize voltage waveform distortion caused by non-linear loads. Single-bearing alternators couple directly to the engine flywheel with flexible discs for drivetrain reliability and durability. No gear reducers or speed changers are used. Two-thirds pitch windings eliminate third-order harmonic content of the AC voltage waveform and provide the standardization desired for paralleling of generator sets. The standard excitation system is a PMG excited system. Alternator Application Notes Separately Excited Permanent Magnet Generator (PMG) System - This standard system uses an integral PMG to supply power to the voltage regulator. A PMG system generally has better motor-starting performance, lower voltage dip upon load application, and better immunity from problems with harmonics in the main alternator output induced by non-linear loads. This system provides improved performance over self-excited regulators in applications that have large transient loads, sensitive electronic loads (especially UPS applications), harmonic content, or that require sustained short-circuit current (sustained 3- phase short circuit current at approximately 3 times rated for 10 seconds). Alternator Sizes - On any given model, various alternator sizes are available to meet individual application needs. Alternator sizes are differentiated by maximum winding temperature rise, at the generator set standby or prime rating, when operated in a 40 o C ambient environment. Available temperature rises range from 80 o C to 150 o C. Not all temperature rise selections are available on all models. Lower temperature rise is accomplished using larger alternators at lower current density. Lower temperature rise alternators have higher motor-starting kva, lower voltage dip upon load application, and they are generally recommended to limit voltage distortion and heating due to harmonics induced by non-linear loads. Alternator Space Heater - is recommended to inhibit condensation. Available Output Voltages Three Phase Reconnectable Three Phase Non-Reconnectable [ ] 220/380 [ ] 220/380 [ ] 240/416 [ ] 277/480 [ ] 254/440 [ ] 347/600 [ ] 277/480 [ ] 2400/4160

Specifications Alternator Design Brushless, 4 pole, drip proof revolving field Stator 2/3 pitch Rotor Direct coupled by flexible disc Insulation System Class H (low voltage) or Class F (medium voltage) per NEMA MG 1-1.65 and BS2757. Standard Temperature Rise 125 o C @ Standby, 105 o C @ Prime Exciter Type Permanent Magnet Generator (PMG) Phase Rotation A (U), B (V), C (W) Alternator Cooling Direct drive centrifugal blower AC Waveform Total Harmonic Distortion <5% total no load to full linear load <3% for any single harmonic Telephone Influence Factor (TIF) <50 per NEMA MG1-22.43 Telephone Harmonic Factor (THF) <3 Three Phase Table 1 80 o C 105 o C 105 o C 105 o C 105 o C 125 o C 125 o C 125 o C 125 o C Feature Code B302 B283 B301 B312 B313 B282 B288 B276 B300 Alternator Data 315 315 315 323 323 315 315 314 314 Sheet Number Voltage Ranges 347/600 220/380 347/600 4160 4160 220/380 240/416 277/480 347/600 Thru 277/480 Thru 277/480 Thru 277/480 Surge kw 1541 1523 1541 1542 1542 1523 1533 1536 1536 Motor Starting kva (at 90% sustained voltage) PMG 6716 6716 6716 7005 7005 6716 6716 5521 5521 Full Load Current - Amps at Standby Rating 220/380 2848 240/415 2602 254/440 2460 277/480 2255 347/600 180 2400/4160 260 Notes: 1. Single Phase Capability: Single phase power can be taken from a three phase generator set at up to 40% of the generator set nameplate kw rating at unity power factor.

Control System PowerCommand Control with AmpSentry TM Protection AmpSentry Protection guards the electrical integrity of the alternator and power system from the effects of overcurrent, over/under voltage, under frequency and overload conditions. Control components are designed to withstand the vibration levels typical in generator sets. Integrated automatic voltage regulator and engine speed governor Standard Control Description Analog % of current meter (amps) Panel backlighting Analog % of load meter (kw) Remote starting, 24 V, 2 wire Analog AC frequency meter Reset switch Analog AC voltage meter Run-Off-Auto switch Cycle cranking control Sealed front panel, gasketed door Digital display panel Self diagnostics Emergency stop switch Separate customer interconnection box Idle mode control Voltmeter/Ammeter phase selector switch Optional Features Shown Menu switch Standard Protection Functions Standard Performance Data Warnings Shutdowns AC Alternator High coolant temperature Emergency stop Current by phase High DC voltage Fail to crank Kilowatts Low coolant temperature High AC voltage Kilowatt hours Low DC voltage High coolant temperature Power factor Low fuel-day tank Low AC voltage Voltage line to line Low oil pressure Low coolant level (option for alarm only) Voltage line to neutral Oil pressure sender fault Low oil pressure Engine Data Overcurrent Magnetic pickup failure Battery voltage Overload load shed contacts Overcrank Coolant temperature Temperature sender fault Overcurrent Engine running hours Up to four customer fault inputs Overspeed Engine starts counter Weak battery Short circuit Oil pressure Underfrequency Oil temperature RPM

Generator Set Options Engine [ ] 75 A battery charging alternator [ ] 208/240/480 V, coolant heaters 10,000 total W max. [ ] 208/240/480 V, coolant heaters 12,840 total W max. [ ] Bypass oil filter [ ] Dual 120 V, 300 W lube oil heaters [ ] Dual 208/240 V, 300 W lube oil heaters [ ] Dual 480 V, 300 W lube oil heaters [ ] Fuel/water separator [ ] Heavy duty air cleaner w/service indicator Cooling System [ ] Heat exchanger cooling [ ] Remote radiator cooling Alternator [ ] 80 o C rise alternator [ ] 105 o C rise alternator [ ] 120/240 V, 300 W anti-condensation heater Control Panel [ ] 120/240 V, 100 W control anticondensation space heater [ ] Exhaust pyrometer [ ] Fuel-pressure gauge [ ] Ground fault indication [ ] Paralleling configuration [ ] Paralleling upgrade configuration [ ] Remote fault signal package [ ] Run relay package Exhaust System [ ] Critical grade exhaust silencer [ ] Exhaust packages [ ] Industrial grade exhaust silencer [ ] Residential grade exhaust silencer Generator Set [ ] AC entrance box [ ] Batteries [ ] Battery charger [ ] Export box packaging [ ] Main line circuit breaker [ ] Paralleling accessories [ ] PowerCommand network [ ] Remote annunciator panel [ ] Spring isolators [ ] 2 year prime power warranty [ ] 2 year standby warranty [ ] 5 year basic power warranty [ ] 5 year comprehensive power warranty [ ] 10 year major components warranty Available Products and Services A wide range of products and services is available to match your power generation system requirements. Cummins Power Generation products and services include: Diesel and Spark-Ignited Generator Sets Transfer Switches Bypass Switches Parallel Load Transfer Equipment Digital Paralleling Switchgear PowerCommand Network and Software Distributor Application Support Planned Maintenance Agreements

Warranty All components and subsystems are covered by an express limited one-year warranty. Other optional and extended factory warranties and local distributor maintenance agreements are available. Contact your distributor/dealer for more information. Certifications ISO9001 - This generator set was designed and manufactured in facilities certified to ISO9001. CSA - This generator set is CSA certified to product class 4215-01. PTS - The Prototype Test Support (PTS) program verifies the performance integrity of the generator set design. Products bearing the PTS symbol have been subjected to demanding tests in accordance to NFPA 110 to verify the design integrity and performance under both normal and abnormal operating conditions including short circuit, endurance, temperature rise, torsional vibration, and transient response, including full load pickup. UL - The generator set is available Listed to UL2200, Stationary Engine Generator Assemblies. The PowerCommand control is Listed to UL508 - Category NITW7 for U.S. and Canadian usage. See your distributor for more information Cummins Power Generation 1400 73rd Avenue N.E. Minneapolis, MN 55432 763.574.5000 Fax: 763.574.5298 www.cumminspowergeneration.com Cummins and PowerCommand are registered trademarks of Cummins Inc. Detector and AmpSentry are trademarks of Cummins Inc. Important: Backfeed to a utility system can cause electrocution and/or property damage. Do not connect generator sets to any building electrical system except through an approved device or after building main switch is open.