Distillation PMA-4. Grabner MINI- FLASH Touch. Grabner MINI- FLASH TAG-4 RT-1 ADU 4+ Grabner MINIDIS ADXpert



Similar documents
Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

The Relation Between Gasoline Quality, Octane Number and the Environment

ADU 5. Automatic Distillation Unit

Colonial Pipeline Company Section 3 Product Codes and Specifications (Effective Date [W] October 29, 2012 March 6, 2013 )

Crude Assay Report. Crude Oil sample marked. "AL SHAHEEN CRUDE OIL" dated 10th April On Behalf Of. Maersk Oil Qatar AS

Effect of GTL Diesel Fuels on Emissions and Engine Performance

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS

Refinery Equipment of Texas. Mini - Refinery Feasibility Overview

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

TIGAS Topsøe s s Improved Gasoline Synthesis

Background Cloud Point Cold Filter Plugging Point

Sulphur in Nigerian Diesel

Hydrogen Sulfide in Petroleum. Mike Nicholson/Tim O BrienO Baker Petrolite Corporation

BQ-9000 Quality Management System. Marketer Requirements

FACE GASOLINES AND BLENDS WITH ETHANOL: DETAILED CHARACTERIZATION OF PHYSICAL AND CHEMICAL PROPERTIES

Flash Point. Test Methods

WASTE COOKING OIL TO FUEL PROGRAM HOW TO START YOUR OWN BIODIESEL FUEL PROGRAM

ASTM Certified Glass Thermometers

Distillation of Alcohol

INVESTIGATION ON DIESEL COLD FLOW PROPERTIES

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Oil Analysis. It is important that the sampling be done in the following manner: 1.

SETTING NATIONAL FUEL QUALITY STANDARDS

Automotive Base Oil Presentation

Worldwide Winter Diesel Fuel Quality Survey 2014

Specifications for Unleaded and Low Sulphur Fuels: Global and Africa Trends. Presented at Workshop on Leaded Gasoline Phase-Out in North Africa

The Effect of Long-Term Cold Storage on Biodiesel Blends

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Portable Density/Specific Gravity/Concentration Meter DMA 35

Created by: Beata Boguszewska ... Arrangements made by: 1. Hanna Laskowska. 2. Tadeusz Głos. I approve for applying From

Waste and Cost Reduction Techniques for Small Parts Cleaners

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

Catalogue June2012, R1.0. Tamson Instruments

Chuck Neece Director Research and Development FUMPA BioFuels

Analytical Standards and CRMs for the Petroleum Industry

Mercedes-Benz Biodiesel Brochure

Notes. Material 1. Appropriate Flammable Liquids

Did you know that. NEXBTL renewable diesel. Premium quality renewable diesel. As a drop-in biofuel, NEXBTL diesel behaves exactly like fossil diesel.

Bakken Crude Oil & Response Considerations. Objectives

Module 1: History of Fuels. Lecture 6: Fundamental definitions, properties and various measurements

Application of Simulation Models in Operations A Success Story

Application of Synthetic Diesel Fuels

ICS Supersedes EN 228:2004. English Version. Automotive fuels - Unleaded petrol - Requirements and test methods

Production of Diesel Fuel From Used Engine Oil

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Ubbel. Viscometers and their range of use. Viscometer type. Cannon-Fenske reverse flow BS/IP-U tube reverse flow. Cannon-Fenske-Routine

Safe Method of Use 7 HSNO Class Flammable Liquids

3M Ionic Liquid Antistat FC-4400

ISANE Isoparaffin Products

Glossary of Energy Terms

MB3600-HP12 / Measurement & Analytics. Laboratory FT-NIR Heavy Oils Analyzer Crude oil, fuel oil, heavy oil upgrader unit feeds

Thermal/Oxidation Storage Stability of Bio-Diesel Fuels

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

Austin Peay State University Department of Chemistry CHEM Empirical Formula of a Compound

Biodiesel Research Project Final Report Summary

SARKOSYL O, an N-acyl sarcosine, is a corrosion inhibitor for lubricating oils, greases O R C N CH COOH CH 2 3

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

BP WIND ENERGY POLICIES AND PROCEDURES

Implications. removing sulphur in. Diesel & Gasoline. Under. Euro IV fuel regime

POLYDIMETHYLSILOXANE

CIMAC Guideline

ORGANIC SAMPLE PREPARATION

Making Biodiesel from Virgin Vegetable Oil: Teacher Manual

Fuel Changes Ultra Low Sulfur Diesel and Biodiesel

H H H O. Pre-Lab Exercises Lab 6: Organic Chemistry. Lab 6: Organic Chemistry Chemistry Define the following: a.

Density/Specific Gravity/ Concentration Meter DMA 500

This document establishes MSHA s Standard Test Procedure (STP) for the Determining the Viscosity of a Hydraulic Fluid in Saybolt Universal Seconds.

Acetaldehyde Production by Ethanol Dehydrogenation

AUTOMOTIVE GAS OIL. Robert Shisoka Hydrocarbon Management Consultancy

precision glass capillary viscometers

H 2 SO 4 vs. HF. A. Feed Availability and Product Requirements

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Propane as the Alternate Fuel for Fleets

TBN Retention of Engine Oil - Improvements through Diesel Fuel Stabilization

Kinematic viscometers in accordance with ISO 3105, DIN 51562, ASTM D445 For automatic and manual viscosity measuring Greatest precision and durability

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

Viscometers. CANNON-FENSKE REVERSE FLOW VISCOMETER TYPE for opaque and transparent liquids

BQ-9000 Quality Management System. Producer Requirements

Sample Test 1 SAMPLE TEST 1. CHAPTER 12

Synthesis of Isopentyl Acetate

Determination of Ultra Low Chlorine (and Sulfur) in Oil

Water Phase Separation in Oxygenated Gasoline - Corrected version of Kevin Krause memo

The photoionization detector (PID) utilizes ultraviolet

Lubricating Oil, Fuel, and Filters

Mobile Density Meter: MDM100 Liquid Density Meter. Installation and Operation Manual

ASimple Guide to Oil Refining

Pumping Fuel & Fuel Oil

Laboratory Hazardous Waste Disposal Guidelines

BioFuels: Understanding their Potential and Limitations. Jim Glancey Departments of Bioresources Engineering and Mechanical Engineering

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

48 Practice Problems for Ch Chem 1C - Joseph

June 2014 TABLE OF CONTENTS

Physical and Chemical Properties and Changes

Pre-Lab Notebook Content: Your notebook should include the title, date, purpose, procedure; data tables.

Designation: Manual of Petroleum Measurement Standards (MPMS), Chapter 9.1

Transcription:

Flash Point We offer the very best in flashpoint test instruments. These instruments are loaded with user friendly features that simplify the testing process. Most instruments are available in a choice of Manual, Semi-Automatic, and Automatic versions. PMA-4 ASTM D93 Pensky-Martens Methods A & B Petrotest s PMA-4 is a fully automatic Pensky-Martens closed cup flashpoint tester. It is equipped with thermal detection, which is required to detect biodiesel flashes, and both gas and electric ignition options. A 12-position sample changer is available. Petrotest also offers a semi-automatic tester, the PM-4, and manual tester, the PM. 12-1771 Model PMA-4 Automatic 12-1651 Model PM-4 Semi-automatic 12-2771 Model PMA-4 with Sample Changer (Shown) 12-0601 Model PM Manual Grabner MINI- FLASH Touch ASTM D6450 and D7094 MINIFLASH (2ml sample size) Grabner Instruments MINIFLASH flashpoint testers, when used per ASTM D7094, provide results statistically equivalent to ASTM D93 while using only a 2mL sample volume. The minimal volume offers improved safety over larger sample sizes, avoids offensive fumes in the testing area, and reduces sample waste. Various working ranges, as well as an 8-position sample changer, are available. 42000 FLP And FLP Touch (0 C to 200 C) 42100 FLA with Sample Changer (0 C to 200 C) 43000 FLPH And FLPH Touch (10 C to 400 C) 43100 FLAH with Sample Changer (10 C to 400 C) 45000 FLPL (-25 C to 100 C) ASTM D56 TAG Method Petrotest s TAG-4 is a fully automatic TAG closed cup flashpoint tester whose method can indicate the possible presence of highly volatile and flammable materials in a relatively nonvolatile or nonflammable material. It is equipped with thermal detection and both gas and electric ignition options. Water cooling lowers the minimum working range temperature to -30 C. 12-0541 Model TAG-4 Automatic Air Cooled 12-1521 Semi-automatic TAG Closed-cup 12-0543 Model TAG-4 Automatic Water Cooled TAG-4 Grabner MINI- FLASH ASTM D3828 RAPID Tester The RT-1 is a semi-automatic, small scale flashpoint tester. It is available in either closed or open cup models as well as a closed cup, stainless-steel model for testing aggressive samples. 12-0201 RT-1 with Closed Aluminum/Brass Test Cup and Lid 12-0200-600 RT- 1 with Closed Stainless Steel Test Cup and Lid 12-0203 Rapid Tester with Open Aluminum/Brass Test Cup Distillation ASTM D86 ADU 4+ Automatic Distillation Unit Petrotest s ADU 4+ is a fully automatic distillation system that provides actual D86 data at a fraction of the cost of competitive models. Distillation data can be easily stored and graphed on its internal PC or output directly to a printer. The ADU-4 is also equipped with a Fire-Extinguisher. 11-5580 Model ADU-4+ Automatic Distillation Unit, Basic Model RT-1 ADU 4+ ASTM D7344 Small Scale Distillation Testing MINIDIS ADXpert Automatic Distillation Grabner Instruments MINIDIS ADXpert completely automates the atmospheric distillation process from sample introduction through disposal. Expensive and fragile glassware is eliminated having been replaced by an inexpensive, disposable metal cup. The MINIDIS provides complete D86-like distillation results, including residual measurement via a built-in balance, in 15 minutes. Only 15ml of sample is needed for both flushing and distillation. The flushing and cleaning processes are also automated. ADXPERT MINIDIS Analyzer Grabner MINIDIS ADXpert

Fuel Analysis GASOLINE OCTANE ANALYSIS IROX-2000 Grabner Instruments IROX-2000 is a fully automatic mid-ftir analyzer that performs rapid, detailed gasoline analysis in less than three minutes. It can provide a detailed analysis including: distillation characteristics, benzene, octane (RON and MON), driveability index, total aromatics, total olefins, total saturates, RVP, total oxygen, and a built-in density meter for API measurements. With the ability to draw sample directly from a bottle, fuel analysis is easier than ever. 50001 IROX 2000 ONLY 3 MINUTES FOR A COMPLETE GASOLINE ANALYSIS PROPERTIES RON 70-105 / 0.5 @ 93 Distillation IBP, T10, T50, T90, FBP MON 70-95 / 0.5 @ 83 RVP 35-95 kpa AKI 80-100 / 0.5 @ 90 Density 0.500-1,999 g/cm3 (integrated density meter) Driveability Index 950-1380 2 freely programmable parameters COMPONENTS Oxygenates Range / Accuracy in weight % Aromatics Range / Accuracy in weight % MTBE 0-20 / 0.5 @ 10% Benzene 0-5 / 0.2 @ 1% / 5-10 / 0.4 @ 5% TAME 0-20 / 0.5 @ 10% Toluene 0-20 / 0.8 @ 5% ETBE 0-20 / 0.5 @ 10% o-xylene 0-20 / 0.8 @ 5% DIPE 0-20 / 0.5 @ 10% p-xylene 0-20 / 0.8 @ 5% Methanol 0-15 / 0.5 @ 10% m-xylene 0-20 / 0.8 @ 5% Ethanol 0-25 / 0.5 @ 10% Ethyl benzene 0-20 / 0.8 @ 5% Iso-Propanol 0-20 / 0.5 @ 10% Propyl benzene 0-20 / 0.8 @ 5% 2-Butanol 0-25 / 0.5 @ 10% 2-Ethyl toluene 0-20 / 0.8 @ 5% tert-butanol 0-25 / 0.5 @ 10% 3-Ethyl toluene 0-20 / 0.8 @ 5% 4-Ethyl toluene 0-20 / 0.8 @ 5% Total Parameters Mesitylene 0-20 / 0.8 @ 5% Aromatics 0-80 / 2 @ 20% Pseudocumene 0-20 / 0.8 @ 5% Olefi ns 0-50 / 1.5 @ 10% Isodurene 0-20 / 0.8 @ 5% Oxygen 0-8 / 0.1 @ 2% Naphthalene 0-10 / 0.8 @ 5% Saturates 20-100 / 3 @ 40% Additional components on request Octane Boosters: e.g. MMT, Nitromethane, DCPD, etc. Biodiesel Blend / Cetane Analysis IROX-Diesel Grabner Instruments IROX-Diesel performs detailed fuel analysis on diesel and biodiesel blends in less than three minutes. Its detailed analysis includes: biodiesel concentration (FAME), component determination, total aromatics, predictions of cetane number, cetane improver, and cetane index as well as density, for API measurements, from its built-in meter. With the ability to draw sample directly from a bottle, diesel and biodiesel analysis is easier than ever. 50100 IROX Diesel IROX 2000 IROX Diesel ONLY 3 MINUTES FOR A COMPLETE DIESEL FUEL ANALYSIS Cetane Number 25-75 Cetane Index 30-70 Cetane Improver 0-5000 ppm Total Aromatics 0-60 wt. % Poly Nuclear Aromatics 0-40 wt. % Biodiesel in Diesel Fuel 0-40 m% Distillation Properties T85, T90, T95 Density (built-in density meter) ± 0.001 g/ccm3 6 freely programmable parameters to determine properties like viscosity, cold properties, etc. Sulfur ASTM D4294 PHOENIX II The SPECTRO Phoenix II is a low cost, polarized ED-XRF solution for monitoring sulfur levels in pipelines, terminals or any at-line application (used to measure ULSD and other ULS applications). Easy to use and rugged, the Phoenix II can be deployed at a fraction of the cost of competitive instruments and is used to meet EPA testing requirements (40 CFR 80.580-585). SPE-PHNXII SPECTRO Phoenix II PHOENIX II

Vapor Pressure Grabner Instruments revolutionized how the industry performs vapor pressure testing through the creation of the MINIVAP VPXpert and VPS. Today, no other manufacturer knows more about engineering vapor pressure instruments than Grabner. These vapor pressure testers remain the #1 choice of both industry and government agencies worldwide for RVP and V/L measurements. These are the most reliable, most frequently used vapor pressure analyzers. ASTM D5191 and D6378 / D6377 MINIVAP VPXpert/ VPS / VPSH The Grabner MINIVAP VPXpert automatically determines the vapor pressure of gasoline and gasolineoxygenate blends. It is the referee instrument used by U.S. government agencies, such as the EPA, for enforcement of environmental regulations. The VPS is used by all major refineries, pipeline companies, and independent inspection companies. Crude oil can be tested using the MINIVAP VPSH. 10121 MINIVAP VPS ASTM D5191 and D6378 -- (ambient to 60 C) 10501 MINIVAP VPXpert ASTM D5191 and D6378 (From 0 C to 120 C) 10190 MINIVAP VPSH ASTM D6377 (0 C to 100 C) ASTM D5188 MINIVOL LVR If you need to report V/L, you need the MINIVOL LVR. Direct measurement of V/L is required by ASTM D4814 for all gasoline-oxygenate blends as the method of calculating V/L is currently deemed unacceptable by the ASTM for use on blended gasoline. The LVR automatically measures the V/L ratio using only 4 ml of sample. 10151 MINIVOL LVR On-Line Vapor Pressure Measurement ASTM D6378 MINIVAP On-Line Gasoline Vaper Pressure ASTM D6377 MINIVAP On-Line Crude Oil Vapor Pressure ASTM D6897 MINIVAP On-Line LPG Vapor Pressure Using the same technology as the MINIVAP VPS, Grabner Instruments MINIVAP ON-LINE allows you to monitor the vapor pressure of gasoline, crude oil, and LPG pipelines and processes. Capable of monitoring two sample streams, this reliable process analyzer also provides a vapor-to-liquid (V/L) ratio value as well as automatic calibration capability. The MINIVAP ON-LINE s measurements correlate with ASTM methods D323, D5191, D5188, and D1267. Storage Stability PetroOXY -- ASTM D7525 Testing of Gasoline & ASTM D7545 Diesel & Biodiesel Fuels The PetroOXY, by Petrotest, is the latest advancement in oxidation-stability testing technology. This alternative to the EN 14112 (Rancimat) test provides repeatable results in a minimum of time. With productivity that is two to five times better than EN 14112, the PetroOXY is ideal for comparing B100 and blended fuel stabilties, determining ideal additive concentrations, as well as process monitoring and control applications. The PetroOXY is very easy to set-up, run, and clean. 13-3003 PetroOXY Automatic Oxidation Stability Tester Color Analysis AUTOMATIC COLORIMETERS Automatic colorimeters are capable of measuring the color of liquid chemicals, industrial oils, petroleum oils, fuels, dark oils, surfactants, water, wastewater and transparent liquids according to virtually any color scale. Available color scales include: ASTM D156 Saybolt, D1500 ASTM Color, Pt-Co/Hazen/ APHA, D6045 Tristimulus, and many more. MANUAL COLORIMETERS Manual colorimeters are a very cost-effective option for performing occasional color measurements. These color comparators allow operators to compare the color of a test sample against color standards in order to determine the value of the sample color. MINIVAP VPS MINIVAP VPXpert MINIVOL LVR PetroOXY

Viscosity We offer a full range of viscosity equipment and instruments including both standard and mini automatic viscometers, full-view constant temperature baths, and viscometer tube glassware. ASTM D445 TV2000/AKV Automatic Kinematic Viscosity The TV2000/AKV automates ASTM D445 viscosity measurements in the range of 0.3 to 10,000 cst. Simply place the sample in a viscosity tube and enter the tube ID. The TV2000/AKV will do the rest! The temperature ranges from ambient +5 up to +230 C. You can select either a Cannon-Fenske or Ubbelohde measuring head. The necessary viscosity tubes are available as accessories. 32-8000 TV2000 Automated Kinematic Viscosity System TV2000/AKV Portable Viscosity Measurement - MINIVIS 445 Grabner Instruments MINIVIS 445 is an easy-to-use rolling ball viscometer. Featuring automatic sample introduction and cleaning, the MINIVIS provides fast results while using only 25ml of sample. The measurable viscosity range is 0.2 to 2000 mpas with a temperature range of 0 to 110 C (-20 C available with water cooling.) 67000 Minivis 445 Grabner MINIVIS VISCOSITY BATHS The TV-Series viscometer and calibration baths are specially designed for tests that not only require ultra-precise temperature control, but also where processes need to be followed visually such as viscosity per ASTM D445. Available in models of varying size and capacity, all of the baths can operate from ambient +5 C up to +230 C (± 0.01 C). Cooling options for performing sub-ambient testing are available. A complete selection of viscosity tubes and accessories is also available. TV Series Cold Flow Properties ASTM D97 Pour Point ASTM D2500 Cloud Point ASTM D2386 Freezing Point ASTM D6371 Cold Filter Plugging Point (CFPP) A range of fully automatic cold flow property analyzers are available. Safe and reliable, these analyzers are equipped with direct refrigeration technology that eliminates cryostats and their hazardous alcohols. Systems are available to automatically perform from one to four cold flow property tests simultaneously. Constant temperature baths and accessories are available for the manual performance of cold flow property tests.

Petrolab Company The refineries and import terminals in North America are limited to relatively few geographic locations. Consequently, the citizens and economies of the continent depend upon an extensive and efficient network of pipeline, terminal, and transport companies to deliver the quality energy products needed to heat and power their homes, businesses, and vehicles. Petrolab Company, an established and well-regarded source of petroleum testing instrumentation, is strongly positioned to support you in the control and quality assurance of your transport, storage, and fuel blending operations. In this document, we will introduce you to a selection of the petroleum testing and calibration instruments that we offer and service. More detailed information on individual products is available from our web site, www.petrolab.com, or by contacting our Broken Arrow, OK, headquarters directly at 918-459-7170 or petrolab.sales@ametek.com. 2001 N Indianwood Ave Broken Arrow, OK 74012 TEL: (918) 489-7170 FAX: (918) 459-7178 petrolab.sales@ametek.com www.petrolab.com 2011, by AMETEK, Inc. Printed in the U.S.A. 2.5M308BG (060115)