OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING



Similar documents
B-AIR BLOWER CUB POWER MODEL # CP-1

8" BENCH GRINDER OWNER'S MANUAL

Get Me Cool Now Portable Air Conditioner User s Manual

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

3 WATT LED SPOTLIGHT Model No. SLM

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

12-Volt 10-Amp Regulated Power Supply

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Multi-Pitch Pitching Machine USER MANUAL

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

Wine Cooler with Thermo-Electric Cooling & Heating Technology

The Storm 20-Gallon Wet/Dry Vac

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

1 HP MINI DUST COLLECTOR

SMS SERIES MIXER SYSTEM INSTALLATION AND MAINTENANCE MANUAL

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

3000W Power Inverter

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

CARING FOR YOUR WATER HEATER

User Manual HomeGrid 3000 Solar Generator

WARMER or COOKER/WARMER

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

SUBMERSIBLE SEWAGE PUMP 66119

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Owner s Manual. ULTRA-POWER II ACCU-POWER & ACCU-POWER ONBOARD Solid State Fully Automatic Chargers. Manual Number Edition Code 0493B0101A

How To Size A Stenner Pump

Dehumidifier Users manual. For Models: DH45S DH65S

Tablet Management Rack 16

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

2-SLICE COOL TOUCH TOASTER

POWER TO GET THE JOB DONE

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Owner s Manual & Safety Instructions

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

User s Manual Before using the inverter, you need to read and save the safety instructions.

Instructions & Safety Information Models A220-20D and A220-20L Version 2

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Ride-on Car OWNER S MANUAL KT1151TG. Keep instructions for future reference

1/3 HP Submersible Sump Pump with Vertical Float Switch

DUST COLLECTOR 70 GALLON, 2 HP

Master Prep Professional

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Micron-Master EL Series Fogger

1100 LB. ELECTRIC HOIST

Operating Instructions Split System Air Conditioner

- 2 - IMPORTANT SAFETY REMINDERS

INFRARED QUARTZ WALL HEATER

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

accidents which arise due to nonobservance and the safety information herein.

CHARGING SYSTEMS INTERNATIONAL

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Portable Air Conditioner

National- Spencer Inc.

GAS SAFETY PRECAUTIONS

Mini-led spotlight with magnetic base

October Safety Subject

COMPRESSED AIR DRYER

Congratulations on your purchase of the Great Planes SLOT MACHINE, the first truly easy way to cut hinge slots in your model airplanes.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

American DJ. Roto-Balls VS MKII. User Instructions. American DJ

Visit our website at: our technical support at:

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Single Phase Soft Starter

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

400 Amp Rechargeable Jump Start System RAC-HP082

ClearView 100. Instruction Manual

120Volt 60-70A ARC WELDER Rev

100 Series Maxi Internal Filters. Instruction Manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Extension Cord Safety Policy

INSTRUCTION MANUAL. Manufactured for: Phoenix Manufacturing Inc. 90% Less energy consumption

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

DBF 4XL Dryer Booster Fans

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

IR Repeater. Operation Manual P8620

Meaco 30L and Meaco 40L dehumidifier instruction manual

Electrical Safety Tips. Help us keep you safe

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Electrical Safety In and Around the Home

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Cambridge Electric Infared Fireplace User Manual

electric kettle owner's manual SAVE THIS USE AND CARE BOOK Please call with questions. MGD550

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Transcription:

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING PLEASE READ AND SAVE THESE INSTRUCTIONS

- 2 - INTRODUCTION TO THE BIG BEAR VORTEX FAN YOUR NEW BIG BEAR FAN HAS A 3/4 HP HIGH EFFICIENCY MOTOR WITH THE FOLLOWING FEATURES: STATE OF THE ART CONSTRUCTION. SAFETY SCREENS ON OPEN VENTS. EASY TO USE COMBINATION CARRYING HANDLE / CORD WRAPPING FEATURE. BUILT IN WHEELS FOR EASE OF MOVING. ADJUSTABLE FAN POSITIONS FROM 0 TO 90 DEGREES. 2 SPEED SWITCH. 3 BUILT IN WIND STABILIZING POLE RECEPTACLES. UNIQUE 4 POINT STABLE BASE. PRE-DRILLED 5/16 HOLE IN CENTER OF FAN GRILL TO ACCOMMODATE A LIGHTING SYSTEM. OPERATION/USE THE BIG BEAR FAN IS SUITABLE FOR A VARIETY OF APPLICATIONS SUCH AS: ADVERTISING DISPLAYS, VENTILATION AND RESTORATION INDUSTRIES. A) CAREFULLY PLACE THE BIG BEAR FAN UNIT ON A STABLE FLAT DRY SURFACE DURING OPERATION. B) THE BIG BEAR FAN IS EQUIPTED WITH A 2 VELCRO AROUND THE OUTER PERIMETER OF THE FAN S EXHAUST PORT. C) ADJUSTABLE 0 TO 90 DEGREE POSITIONING. D) BIG BEAR FAN OPERATION MUST BE SUPERVISED AT ALL TIMES. ROTATE PULL DISASSEMBLE 17" ASSEMBLE 38 ã STORAGE STORE UNIT INDOORS IN A CLEAN DRY ENVIRONMENT TO ENSURE LONG LIFE

- 3 - SAFETY 1) KEEP CHILDREN AND PETS AWAY FROM UNIT WHILE IN OPERATION AND/OR PLUGGED IN. 2) DO NOT PUT FINGERS OR OTHER OBJECTS IN UNIT WHILE IN OPERATION AND/OR PLUGGED IN. 3) TO AVOID ELECTRIC SHOCK DO NOT OPERATE IN POOLED WATER 4) UNIT MUST BE KEPT DRY AT ALL TIMES, INCLUDING MOTOR, WIRING AND EXTERIOR. IF UNIT BECOMES WET, THOROUGHLY DRY BEFORE NEXT OPERATION. 5) USE ONLY WITH A GROUNDED PLUG AND/OR EXTENSION CORD TO AVOID RISK OF ELECTRICAL SHOCK OR FIRE. REMEMBER NEVER TO USE A CORD WITH ANY KIND OF DAMAGE OR WEAR. 6) MAKE SURE THE POWER SOURCE IS SUFFICIENT TO MEET THE REQUIREMENTS OF THE BLOWER. 7) TO PREVENT OVERHEATING THE UNIT, KEEP AIR INTAKES CLEAR AT ALL TIMES 8) CLOGGING OR BLOCKING THE AIR INTAKES COULD RESULT IN A FIRE OR ELECTRICAL HAZARD. 9) IN ORDER TO PREVENT INJURY DO NOT REMOVE ANY SCREENS OR SAFETY GUARDS FROM THE UNIT AND TO AVOID OBJECTS FROM COMING IN CONTACT WITH THE FAN. UNIT DAMAGE IN THIS MANNER WILL VOID YOUR WARRANTY. 10) DO NOT OPERATE UNIT CLOSE TO ANY DANGEROUS AREAS, SUCH AS EXPLOSIVE GASES, FLAMMABLES, HEATERS AND UNVENTILATED ENVIRONMENTS, WHICH MAY RESULT IN EXPLOSIONS OR ELECTRICAL HAZZARDS. 11) DO NOT USE ANY FORM OF SPEED CONTROL DEVICE AS DOING SO MAY CAUSE INJURY OR FIRE. 12) ALWAYS PLACE FAN ON A SMOOTH AND LEVELED SURFACE FOR SAFE OPERATION. 13) DO NOT USE UNIT IF DAMAGED. 14) BEFORE CLEANING OR SERVICING UNPLUG UNIT. 15) ALL FANS IN OPERATION MUST BE SUPERVISED AT ALL TIMES. 16) DO NOT SIT OR STAND ON FAN UNIT. 17) UNPLUG FAN WHEN NOT IN USE. 18) MAKE SURE FAN SWITCH IS IN OFF POSITION BEFORE PLUGGING INTO THE POWER SOURCE. 19) MAKE SURE HANDS ARE DRY BEFORE HANDLING FAN OR POWER CORD. 20) ONLY A QUALIFIED ELECTRICIAN SHOULD ATTEMPT TO REPAIR / REPLACE ANY ELECTRICAL COMPONENTS. 21) DO NOT LOOK INTO FAN OPENING IN ORDER TO AVOID ANY FLYING DEBRI FROM BLOWING INTO YOUR FACE OR EYES.

- 4-22) DO NOT EXPOSE TO RAIN, WATER OR SNOW. 23) OUTDOOR USE: UNIT MUST BE CONNECTED TO A G.F.C.I (GROUND FAULT CIRCUIT INTERRUPTER) PROTECTED RECEPTACLE. WARRANTY 1 YEAR: B-AIR WILL COVER ALL PARTS (EXCEPT POWER CORD). WHITHIN ONE YEAR OF PURCHASE B-AIR WILL PAY REPAIR COSTS AND ONE WAY UPS GROUND SERVICE SHIPPING TO YOUR LOCATION WHITHIN THE 48 CONTIGUOUS STATES. PROOF OF PURCHASE IS REQUIRED. CUSTOMER IS RESPONSIBLE FOR SHIPMENT OF DAMAGED UNIT TO B-AIR WAREHOUSE FOR REPAIR. CANADA AND NON-CONTIGUOUS STATES MUST PAY FREIGHT BOTH WAYS. 5-YEAR: B-AIR WILL COVER HOUSING FROM DATE OF ORIGINAL PURCHASE. PROOF OF PURCHASE IS REQUIRED. SERVICE IN ORDER TO RECEIVE SERVICE OR REPLACEMENT PARTS UNDER WARRANTY, YOU MUST: A) CALL FOR A RMA# (Return Merchandise Authorization Number) B) HAVE PROOF OF PURCHASE C) SHIP TO B-AIR BLOWER IF IMMEDIATE SERVICE IS REQUIRED, B-AIR WILL SHIP A REFURBISHED FAN IMMEDIATELY TO REPLACE THE ONE REQUIRING SERVICE PROVIDED A VALID CREDIT CARD IS PROVIDED AND CHARGED. ONCE WE RECEIVE YOUR FAN, WE WILL CREDIT YOUR CREDIT CARD ACCOUNT. WE WILL GLADLY REPAIR YOUR FAN AND SHIP WITHIN 24 HOURS UPON INSPECTION, WE WILL ADVISE YOU OF THE REPAIRS NEEDED AND THE COST (IF APPLICABLE). B-AIR WILL ISSUE REPAIR OR REPLACEMENT PARTS DEPENDING ON WARRANTY. CORDS 1) DO NOT USE EXTENSION CORDS FOR OUTSIDE USE.

- 5-2) USE 3 PRONG ADAPTORS THAT ARE UL AND CE APPROVED AND NOT LESS THAN 16-3 WITH GROUND FAULT CIRCUIT INTERRUPTER (GFCI). 3) DO NOT USE CORDS THAT SHOW ANY KIND OR WEAR OR DAMAGE. 4) CORDS ARE NOT COVERED BY WARRANTY. BIG BEAR FAN LIMITED WARRANTY COVERS 1) BIG BEAR FAN IS COVERED AGAINST DEFECTS IN MATERIAL AND CRAFTSMANSHIP USED UNDER NORMAL INTENDED USE TO ORIGINAL PURCHASER FOR A TERM OF (1) ONE-YEAR FROM THE ORIGINAL DATE OF PURCHASE INCLUDING PARTS, LABOR AND SHIPPING. 2) BIG BEAR FAN HOUSING IS COVERED FOR A TERM OF (5) FIVE FULL YEARS FROM THE DATE OF THE ORIGINAL PURCHASE. DOES NOT COVER 1) ANY SIGNS OF MISUSE INCLUDING, BUT NOT LIMITED TO ROUGH HANDLING, ABUSE, TAMPERING, IMPROPER VOLTAGE USE, AND UNAUTHORIZED MAINTENANCE AND REPAIRS. WARNING BIG BEAR FAN MUST BE SUPERVISED AND ATTENDED AT ALL TIMES. THE USE OF A 3-PRONG TO 2-PRONG ADAPTER IS PROHIBITED. ONLY USE A 2-PRONG TO 2-PRONG ADAPTER. IF THE POWER SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD. CONTACT INTERTEX, INC. / B-AIR BLOWERS 1851 TYBURN STREET GLENDALE, CA 91204 1-877-800-2247 (BAIR) FAX: (818) 242-2430 EMAIL: info@b-air.com WEB SITE: www.b-air.com

- 6 - SPECIFICATIONS MODEL# BB-1 VOLTS 115 V 230 V CYCLE 60 Hz 50 Hz MAX AIR VOLUME 5080 CFM 5450 CFM AMPS 5.8A 4.5A MAX STATIC PRESSURE 1.8 INCH 1.8 INCH WEIGHT NET/SHIP 43/47 LBS 43/47 LBS UNIT SIZE (L x W x H) 23 x 22.5 x 14 23 x 22.5 x 14 FAN SPEED (RPM) L 3300 / H 3500 L 2500 / H 2840 MOTOR 3/4 HP 3/4 HP ATTACHED CORD (16G) 25 FT 25 FT SPEEDS 2 2 STAND HEIGHT 18.5 18.5 MAX TUBE CAPACITY 70 70 OUTLET DIMENSION 55.5 55.5 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Motor Not Running a) Switch is OFF a) Turn Switch ON b) Bad Outlet b) Check Outlet/ Change to Another Outlet c) Faulty Switch/Cord c) Call Factory for new Switch/Replace Cord Scraping Noise From fan blade a) Fan blade loose a) Call Factory for advice