The University of Southern Maine. XRF X-Ray Radiation Protection Program



Similar documents
X-ray Radiation Safety Course. James Kane & Rob Deters Office of Radiological Control

Safety and Radiation Protection Office Working with X-Ray Equipment

PERSONNEL MONITORING AND DOSIMETRY POLICIES

Analytical X-ray Safety Refresh Training. Radiation Safety Officer Department of Environmental Health and Safety

Radiation Safety Committee College of William and Mary

Radiologic Technology Program. Radiation Safety and Protection Program

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

DEPARTMENT OF ENVIRONMENT, HEALTH & SAFETY RADIATION SAFETY DIVISION. University of California, Los Angeles RADIATION SAFETY GUIDANCE

Specific local rules for governing the use of the Niton XLt Environmental Analyser (portable XRF): Laboratory

X-ray Safety Manual 2013

Personal Dosimetry in Dental Radiology

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

X-RAY REGULATORY GUIDE

INFORMATION NOTICE: USE OF XRF DEVICES CONTAINING RADIOACTIVE MATERIAL North Dakota Department of Health Radiation Control Program (2/06)

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

The effects of radiation on the body can be divided into Stochastic (random) effects and deterministic or Non-stochastic effects.

LASER SAFETY MANUAL UNIVERSITY OF KENTUCKY POLICIES AND PROCEDURES FOR LASER USERS REVISED EDITION 2012 ISSUED BY

Required RS Training Info

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Prepared for the Department of Energy Office of Transportation and Emergency Management. 02B p65

Regulatory Guide. Radiation Safety in Industrial Radiography (FANR-RG-019) Version 0

Personal Radiation Monitoring Service

Section 4 RADIATION SAFETY RULES AND REGULATIONS

Radiation Safety Issues for Radiologic Technologists

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

(Translated Version Jan. 2013)

Radiation Dose Limits. Radiation Safety Training Module 3

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

RADIOACTIVE WASTE MANAGEMENT PLAN

PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT. Definitions. As used in this Part, the following definitions apply:

Radiology Services Policies and Procedures

Northern Illinois University Laser Safety Program

OSHA Compliance Checklist ASC

Wisconsin Chapter DHS 157- Radiation Protection Regulatory Guide May, 2010

RADIATION SAFETY STANDARD

portable x-ray survey report

Environment of Care Hazardous Materials and Waste Management Plan

Radiation Safety at LLNL General Employee Radiological Training GERT HS6001-W

Radiation Rule Guide. Veterinary Facilities. Hawaii Administrative Rules, Chapter 11-45, Radiation Control. Hawaii State Department of Health

Emergencies Involving Radiation

RADIATION PROTECTION PROGRAM (RPP) GUIDANCE

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF RADIATION THERAPY TECHNOLOGY

PART B REGISTRATION [LICENSURE] OF RADIATION MACHINE FACILITIES, [SERVICES] */ AND ASSOCIATED HEALTHCARE PROFESSIONALS

Rice University Laser Safety Manual

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

Frequently Asked Questions: The following regulations are provided to answer some of the many questions that are asked of this office.

General requirements. 1. Administrative Controls.

H-0123 Contractor Safety Program

Harvard University Radiation Safety Manual

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Division of Public Health Administrative Manual

Radiation safety in dental radiography

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY

25 TEXAS ADMINISTRATIVE CODE Registration of Radiation Machine Use and Services. Texas Regulations for Control of Radiation

Each has the following responsibilities under this SOP:

GUIDE FOR THE PREPARATION OF RADIOACTIVE MATERIAL APPLICATIONS FOR WELL LOGGING OPERATIONS IN KENTUCKY

Facility Safety Plan State University of New York Upstate Medical University

Loss Control TIPS Technical Information Paper Series

School Science Lab Safety Guidelines

Staff Doses & Practical Radiation Protection in DEXA

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

PART 34--LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS

University of Pittsburgh Safety Manual. EH&S Guideline Number: ASBESTOS

RMM 501 Hazardous Materials Management Systems Including WHMIS Program Page 2 November 2014

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Department of Environmental Health and Safety & Emergency Management

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF DENTAL RADIOLOGIC TECHNOLOGY

Working Safely With Nuclear Gauges

HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)

Agency for Health Care Administration

Policy: Accident & Injury Reporting Category: Operations. Authorized by: Joan Arruda, CEO

LASER SAFETY PROGRAM FOR CANISIUS COLLEGE (Department of Chemistry and Biochemistry) Effective: October 1, 2007 Revised: June 3, 2010

Radiation Safety Training

Introduction. Chapter 15 Radiation Protection. Regulatory bodies. Dose Equivalent. Regulatory bodies. Main Principles of Radiation Protection

X-ray Operating Procedures and Safety Manual

Educational Tool for Medical Laser Programs 1. Laser Safety

British Columbia Institute of Technology. BCIT Safety Manual ASBESTOS MANAGEMENT

X-ray (Radiography) - Bone

Chapter XIV OCCUPATIONAL SAFETY AND HEALTH ACT. The Occupational Safety and Health Act (the Act ), 29 U.S.C. 651, et seq., is

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer

SNAP-ON INCORPORATED STANDARD ON EMPLOYEE TRAINING PROGRAM

Guidance Document For The Use of Lasers and Intense Pulse Light in Licensed Special Treatment Premises Within The London Borough of Brent

EMERGENCY PROCEDURES FOR RADIOACTIVE MATERIAL. 2. Prevent the spread of contamination by covering the spill with absorbent paper.

X-RAY SAFETY MANUAL. WRHA X-ray Safety Committee

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

THE UNIVERSITY OF TEXAS MEDICAL BRANCH LASER SAFETY MANUAL ENVIRONMENTAL HEALTH & SAFETY

Infectious Waste Management Plan

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

PRODUCT SAFETY DATA SHEET

Biological Safety Program

Staff Skin Care Policy

Transcription:

The University of Southern Maine XRF X-Ray Radiation Protection Program 1

University of Southern Maine Department of Environmental Sciences 105 Bailey Gorham Hand Held XRF Analyzer X-Ray Radiation Protection Program 1. Purpose 1.1. The purpose of this X-Ray Radiation Protection Program (XRPP) is to minimize radiation exposures to workers using a portable, X-Ray Tube based Thermo NITON Analyzer (XRF) at the University of Southern Maine (USM) to levels that are as low as reasonably achievable (ALARA), and to 1.2. Ensure that use of the XRF is in compliance with all applicable State and Federal regulations. 2. Scope 2.1. This XRPP applies to the use of the XRF at USM. 3. Responsibilities 3.1. The Radiation Safety Officer (RSO) shall be designated as the individual in charge of the XRPP. The RSO will be responsible for ensuring the XRPP minimizes the risks associated with using the portable XRF and will ensure compliance with the regulations of the State of Maine related to XRF use. 3.2. The RSO will advise and direct the Factory Trained Operator (FTO), who will prepare equipment specific operating and safety procedures for the safe operation of the XRF. 3.2.1. The FTO has received Radiation Safety Training from the RSO and Radiation Safety Training and XRF specific training at an 8 hour course provided by Thermo NITON Analyzers. 2

3.2.2. The FTO will show receipt of the Factory training by providing a certificate of completion from the factory which is to be kept on file with other XRPP documents. 3.2.3. The RSO/FTO will; 3.2.3.1.Develop a training and certification program for authorized users. 3.2.3.1.1. Training shall include radiation safety, regulatory compliance, operational, and emergency procedures. 3.2.3.2.The RSO/FTO will maintain records of training including a copy of the training material. 3.2.3.3.Maintain a list of authorized users and will ensure that only authorized users operate the XRF Analyzer. See Appendix B. 3.2.3.4.Ensure that authorized users are issued and wear personal dosimetry while operating the XRF. 3.2.3.5.Maintain dosimetry records for authorized users. 3.2.3.6.Maintain manufacturer provided instruction manuals, operations, and maintenance records. 3.2.3.7.Ensure that labels on the XRF are intact and legible. Notify Thermo Fisher Scientific for assistance when labeling is damaged or illegible. 3.2.3.8.Review the XRPP content, implementation, and effectiveness annually to ensure the material is accurate and up to date. 3.3. Authorized Users are responsible for following only approved techniques and procedures for the safe operation of the XRF analyzer. The specific actions to be performed are as follows: 3.3.1. Follow proper operating procedures as described in training and ensure other individuals also adhere to these requirements. 3

3.3.2. Ensure that the label on the XRF is intact and legible. 3.3.3. Ensure proper use of dosimetry. 3.3.4. Be familiar with emergency procedures and know how to recognize and stop unsafe operations. 4. Operating Procedures 4.1. A copy of the User s Guide, Operating, and Emergency Procedures shall be made available to all authorized users of the NITON XRF. A copy will be kept with the Analyzer and another copy shall be kept on file with the XRPP records. 4.2. Only authorized personnel with training on radiation safety, state regulations, operating and emergency procedures shall be allowed to operate the NITON XRF. All authorized personnel are responsible for complying with the requirements of this XRPP and will report any and all incidents involving the NITON XRF to the RSO/FTO. 4.3. The operator is responsible for ensuring that no part of a person s body is at or near the measurement point, and no closer than one foot during a measurement (trigger finger excluded). 4.4. The operator will use special precaution when analyzing very small samples (i.e., smaller than the measurement window in any dimension), being aware that the sample may not be absorbing the entire primary beam. The operator will use a test stand whenever it is reasonably practical to do so to mitigate the elevated risk of analyzing small samples. 4.5. The operator will use special precautions when analyzing samples of low density, particularly plastics but also aluminum and titanium alloys and other similar low density materials. These samples will emit higher levels of scattered radiation. 4.6. The operator shall be aware that the NITON XRF is emitting radiation when lights are flashing. 4

4.7. The operator shall be aware that radiation in the primary beam could eventually cause physical harm if the device is used improperly and must be able to recognize the symptoms which would begin with skin reddening in the exposed area and at higher doses would appear as a burn or localized tissue damage. 4.8. Prior to each use: 4.8.1. The operator will inspect and maintain the Kapton window and all labels on the NITON XRF 4.8.2. The operator will fill out the utilization log 4.9. USM will maintain a log documenting use of the XRF that contains, at a minimum, date/time removed, date/time returned, and authorized user signing it out. At the front of this log will also be a list of authorized users. See Appendix A. 5. Emergency Procedures 5.1. In any case where one suspects that the x-ray tube remains on when the measurement is terminated: 5.1.1. Disconnect the battery pack immediately to turn off the x-ray tube, and 5.1.2. Notify the RSO/FTO @ 780-5406 or 420-4831 or 780-4126 5.1.3. Call Thermo Fisher Scientific s Service Department in the United States, toll free, at (800) 875-1578. 5.2. In any suspected accidental exposure to primary beam: 5.2.1. Notify the RSO/FTO @ 780-5406 or 420-4831 or 780-4126 5.2.2. The FTO and RSO will investigate the incident and contact the State Radiation Control Program, and/or Thermo Fisher Scientific s RSO. 5

5.2.3. The RSO will write an incident report of any such exposure which will include, at a minimum, the date and time of the exposure, the name of the exposed user, the circumstances leading to the exposure, and any out comes, follow up, or additional actions required. 6. Radiation Safety Training 6.1. The FTO will receive 8 hour Equipment Specific Radiation Safety Training from Thermo NITON Analyzer LLC and Radiation Worker Safety training. 6.2. The RSO/FTO will develop and present Equipment Specific Radiation Safety Training for employees or students designated as authorized users. 6.2.1. The training will include testing for the authorized user to demonstrate knowledge and competency for safe use of the XRF. 6.2.2. This training will be documented by a sign-in sheet and completed tests. 6.3. Authorized users are required to attend Radiation Worker Safety training prior to XRF training. 6.4. Training records will be maintained by the RSO/FTO. 7. Personnel Exposure Monitoring 7.1. Dosimeters shall be issued to and be worn by all authorized users. 7.1.1. The dosimeters worn will be a whole body badge. 7.1.2. The dosimeter shall be worn at the waste or mid-point of the operator 7.1.3. A second dosimeter will be positioned on the outer case of the XRF. 7.1.3.1.This badge will record any xray backscatter radiation experienced during operation 7.2. Authorized users shall only wear issued dosimetry when operating the XRF. 7.2.1. Dosimetry when not in use shall be stored in same location where the XRF is stored. 7.2.2. Dosimeters should be protected from extremes of heat, moisture, and pressure. 6

7.2.3. Dosimeters shall be stored in a protected area to prevent loss, damage, and exposure to other sources of radiation. 7.3. Dosimetry services will be contracted through Landauer, Inc. at 2 Science Road, Glenwood, Illinois 60425-9979 7.4. The period of dosimeter use will be determined by quarterly exposure records and advise from the State Radiation Control Program. 8. Posting and Labeling 8.1. There is a relatively low radiation hazard associated with the XRF, and because the authorized user will be with the XRF at all times during its operation, posting radiation area signs will not be necessary. 8.2. A copy of the State of Maine Notice to Employees will be kept in the XRF case as well as on file with other XRPP documents and will be available for review at any time. 8.3. The label on the XRF will be checked periodically by the RSO/FTO as well as the authorized users of the XRF. The label will be checked for integrity and legibility. If the label becomes faded, worn, damaged, or defaced, the Analyzer will be promptly returned to Thermo NITON Analyzers LLC for relabeling. 9. Record Keeping 9.1. The RSO/FTO will be responsible for all the records associated with the XRPP. These records will be kept in the Core Lab of the Portland Science building and will be made available for review by any worker or state official upon request. The following is a list of records that will be kept at minimum: 9.1.1. Personnel training records 9.1.2. Manufacturer provided instruction manuals and service & maintenance records 7

9.1.3. Authorized Users 9.1.4. State Analytical X-Ray Regulations and Notice to Radiation Workers 9.1.5. XRF usage log 9.1.6. Personnel Dosimetry Records. 10. Quality Assurance / Annual Review 10.1. At the minimum, items on the following list will be done annually: 10.1.1. Radiation Safety Review for all workers 10.1.2. Operational & Emergency Procedures Review for all workers 10.1.3. Audit of the XRPP content, implementation, and effectiveness 11. References: 11.1. DOE G 441.1-5 Radiation-Generating Devices Guide 11.2. Thermo NITON Analyzers Sample Radiation Safety Program 11.3. NBS Handbook 111, Revised 1977 11.4. Radiation Safety Topics Writing a Radiation Protection Program For the Industrial X- Ray Program For a Facility with Cabinet Radiographic or Analytical X-Ray Machines 11.5. Table 11.4.19 Good Work Practice for X-Ray Diffraction and X-Ray Fluorescence Units The Health Physics and Radiological Health Handbook 8

Appendix A Utilization Log Date Time Out Time Returned Reason Responsible Individual 9

Appendix B Authorized Users List Name Dept./Program Date of Rad Worker Training Date of XRF Training 10