High-performance, 2-part epoxy anchoring adhesive



Similar documents
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Elastic, 1-part-polyurethane, liquid waterproofing membrane

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

PC-Concrete Injectable Concrete Anchoring and Repair System

Polymeric membrane for roof waterproofing

Hilti HIT-HY 200 with rebar

PRODUCT DATA SHEET Sika Cable System

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Low viscosity, solvent free elastic adhesive for wood flooring

Hilti HIT-HY 150 MAX with rebar

Injection System VMU. Injection System for non-cracked concrete and brickwork. Threaded Stud VMU-A for concrete and brickwork

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

2-part Epoxy primer, levelling mortar and intermediate layer

Black epoxy paste adhesive system

2-part epoxy textured roller and seal coat

(English language translation, the original version is in French language) Chemical anchoring system WIT-200

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Two component epoxy paste adhesive

3M Scotch-Weld EPX Two-component structural adhesives and applicator guns

Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Technical Application Document. Hilti HIT-RE 500-SD

Construction. High Performance polyurethane joint sealant. Description. Specifications Satisfied. Uses. Advantages. Instructions for Use

Bonded Anchors & Mechanical Anchors

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

INSTALLATION INSTRUCTIONS RISE SEALING SYSTEM FOR MULTI-CABLE TRANSITS

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

HVU with HAS/HAS-E rod adhesive anchor

Technical Data Sheet February 2014

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Sikagard -203 W (Steridex)

Solvent Cementing Instructions For Plastic Pipe & Fittings

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

SC2000 CEMENT BONDING PROCEDURES

Temperature C Cure time to reach hours LSS > 1MPa minutes

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Wecryl Waterproofing System under surfacing supplied by others

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

(English language translation, the original version is in French language) Injection system Hilti HIT-HY 150 MAX

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

DECLARATION OF PERFORMANCE

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

(T indicates a Tropicalised version with extended workability. No change has been made to the formulation)

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Araldite LY 3505* / Hardeners XB 3403* / Hardener XB * / Aradur 3405*

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

How To Test A Base Axe

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

The Effects of Hole Cleaning on Post-Installed Anchor Systems in Concrete

Minor Cracks in Horizontal Surfaces

Mapei systems for radiating floor heating with high thermal efficiency

Highly flexible couplings

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

HUS-HR, CR Screw anchor, stainless steel

PP / PE X X X X (X) X PA (X) X

3 Scotch-Weld TM. Epoxy Adhesive DP110 Translucent and Gray. Technical Data December, 2009

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

FIVE STAR PRODUCTS, INC. (800)

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Sealing & Bonding Sika solutions for Window Installation

European Technical Assessment ETA-10/0153 of 10/06/2015

Tecnoepo Flooring System 185

Sikaflex Sealant Installation. Sika Corporation

ClikSTAR - Important facts about your new insulin delivery device.

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

Scotch-Weld. Epoxy Adhesives DP-100 Clear DP-100 NS Translucent. Technical Data June, 2002

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Ermächtigt u n d n o t i f i z i e r t gemäß Artikel 10 der Richtlinie des Rates vom 21. Dezember 1988 zur Angleichung

SikaProof A Technology

Division 9. SignaFlor Pad and Pour Flooring System

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM


Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Document Library TS Data Sheet

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

BLACK JACK ALL WEATHER ROOF COATING

Resurfacing Concrete. Page 1 of 5

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

SPECIAL INSPECTION AND TESTING AGREEMENT INTERNATIONAL BUILDING CODE

K2 STONE NATURAL VENEER

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Transcription:

Product Data Sheet Edition 27/04/2009 Revision no: 0 Identification no: 01 04 02 06 001 0 000030-3+ -3+ High-performance, 2-part epoxy anchoring adhesive Construction Product Description Uses Solvent-free, thixotropic, two part, epoxy resin-based, high performance anchoring adhesive. For the fixing of non-expanding anchors in the following: Structural work: Rebar / steel reinforcement anchoring in new and refurbishment works Threaded rods Bolts and special fastening / fixing systems Mechanical and electrical services installation (heating and ventilating, sanitary, etc) Anchoring of supports for ducting and equipment Metalwork, carpentry: Fixing of handrails, balustrades and supports Fixing of railings Fixing of window and door frames In the following substrates: Concrete Hard natural and reconstituted stone Solid rock Hollow and solid masonry Steel Wood Characteristics / Advantages Long Open Time Can be used in damp concrete High load capacity Non-sag, even overhead Styrene-free Excellent adhesion to the substrate Shrinkage-free hardening Standard guns can be used (with the 250ml cartridge) Low odour Low wastage Tests Approval / Standards Tested according to the ETAG001 and NF standards. Tested according to EN 1504-6 1-3+ 1/6

Product Data Form Colours Part A: clear / translucent Part B: grey Part A+B mixed: light grey Packaging 250 ml standard cartridge, 12 per box. Pallet: 60 boxes with 12 cartridges. 400 ml side by side cartridge, 12 per box. Pallet: 50 boxes with 12 cartridges. 1500 ml side by side cartridge, 5 per box. Pallet: 50 boxes with 5 cartridges. Storage Storage Conditions / Shelf-Life 12 months from date of production if stored properly in original unopened, sealed and undamaged packaging in cool and dry conditions at temperatures between +5 C and +30 C. Protect from direct sunlight. All -3+ cartridges have the expiry date printed on the label. Technical Data Density Curing Speed Part A: 1.18 kg/l Part B: 1.71 kg/l 1.45 kg/l (part A+B mixed) Temperature Open Time T gel Curing Time T cur > +40 C 10 minutes 7 hours +20 C - +35 C 15 minutes 14 hours +10 C - +20 C 35 minutes 30 hours +5 C - +10 C 75 minutes 45 hours *Min. cartridge temperature = +5 C Sag Flow Layer Thickness Mechanical / Physical Properties Compressive Strength Non-sag, even overhead. 5 mm max. (According to ASTM D695-96) Curing time +5 C +23 C +40 C 16 hours ~11 N/mm 2 ~94 N/mm 2 ~108 N/mm 2 1 day ~17 N/mm 2 ~104 N/mm 2 ~115 N/mm 2 3 days ~ 86 N/mm 2 ~112 N/mm 2 ~123 N/mm 2 7 days ~ 89 N/mm 2 ~114 N/mm 2 ~127 N/mm 2 +/- 5 N/mm 2 2-3+ 2/6

Pull out Strength Pull-out tests (according to standard NF P 18-822): Anchoring of rebar in slabs: Conditions: Steel quality Rebar diameter Drill hole diameter Anchoring depths B500B 12 mm 22 mm 120 mm Test result: Ultimate load >70 kn*, slippage < 0.6 mm *Maximum load of the testing machine Pull-out tests (according to ETAG 001): unconfined Anchoring of threaded rods in slabs: Conditions: Steel quality 12.9 Threaded rod Drill hole diameter Anchoring depths Test result: F t Rk, log >75 kn, concrete failure M12 14.3 mm 110 mm Resistance Thermal Resistance -40 C to +45 C +45 C long term System Information Application Details Consumption / Dosage Material consumption per anchor in ml Anchor Ø mm Drill Drill hole depth in mm Ø mm 8 90 110 120 130 140 160 170 180 200 210 220 240 260 280 300 350 400 8 10 3 4 4 5 5 5 6 6 7 7 7 8 8 9 9 10 11 12 10 12 4 5 5 6 6 6 7 8 8 8 8 9 10 10 11 12 14 15 12 14 5 6 6 6 7 7 8 8 9 10 10 11 11 12 13 14 16 18 14 18 9 10 11 14 14 15 18 19 20 22 23 24 26 28 30 32 37 42 16 18 9 10 11 13 14 15 17 18 19 21 22 23 26 28 30 32 36 40 20 10 12 12 15 16 17 20 21 22 24 25 26 29 31 33 35 40 46 20 24 12 13 14 15 16 18 22 24 26 28 30 32 36 38 42 48 58 66 25 18 19 21 23 24 26 30 31 32 36 38 40 44 46 50 54 64 72 24 26 24 25 28 30 33 35 40 43 45 50 55 58 60 65 70 75 100 125 The indicated filling quantities are calculated without wastage. Wastage 10-50%. Substrate Quality Mortar and concrete must be older than 28 days. Substrate strength (concrete, masonry, natural stone) must be verified. Pull-out tests must be carried out if the substrate strength is unknown. The anchor hole must always be clean, dry, free from oil and grease, etc. Loose particles must be removed from the holes. Threaded rods and rebars have to be cleaned thoroughly from any oil, grease or any other substances and particles such as dirt etc. 3-3+ 3/6

Application Conditions / Limitations Substrate Temperature Ambient Temperature Material Temperature Dew Point 0 C min. / +40 C max. 0 C min. / +40 C max. -3+ must be used at a temperature of between +5 C and +30 C. Substrate temperature during application must be at least 3 C above dew point to avoid condensation. Application Instructions Mixing Mixing Tools Part A : part B = 1 : 1 by volume Getting the cartridge ready: 250 ml 400ml 1500ml Unscrew and remove the cap 250 and 400ml Cartridges: - Pull out the plug 1500ml Cartridges: - Cut the two plugs of the cartridge Screw on the static mixer Place the cartridge into the gun and start application When work is interrupted the static mixer can remain on the cartridge after the gun pressure has been relieved. If the resin has hardened in the nozzle when work is resumed, a new nozzle must be attached. Application Method / Tools General Remarks: Drilling of hole with an electric drill to the diameter and depth required. Drill hole diameter must be in accordance with anchor size. The drill hole must be cleaned with a blow pump or by compressed air, starting from the bottom of the hole. (at least twice) oil-free compressors shall be used The drill hole must be thoroughly cleaned with the special steel brush (brush at least twice). The diameter of the brush must be larger than the diameter of the drill hole. The drill hole must be then be cleaned again with a blow pump or by compressed air, starting from the bottom of the hole. (at least twice again) oil-free compressors shall be used 4-3+ 4/6

The drill hole must be thoroughly cleaned with the special steel brush again (brush at least twice again). The diameter of the brush must be larger than the diameter of the drill hole. The drill hole must then be finally cleaned yet again with a blow pump or by compressed air, starting from the bottom of the hole. (at least twice) oil-free compressors shall be used Pump approx. twice until both parts come out uniformly. Do not use this material. Release the gun pressure and clean the cartridge opening with a cloth. Inject the adhesive into the hole, starting from the bottom, while slowly drawing back the static mixer. In any case avoid entrapping air. For deep holes extension tubing can be used. Insert the anchor with a rotary motion into the filled drill hole. Some adhesive must come out of the hole. Important: the anchor must be placed within the open time. During the resin hardening time the anchor must not be moved or loaded. Wash tools immediately with Sika Colma Cleaner. Wash hands and skin thoroughly with warm soap water. Cleaning of Tools Value Base Clean all tools and application equipment with Sika Colma Cleaner immediately after use. Hardened / cured material can only be removed mechanically. All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Local Restrictions Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. Health and Safety Information Legal Notes For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. 5-3+ 5/6

CE Labelling 0921 2) 1001 Sika Schweiz AG Tueffenwies 16-22 CH - 8048 Zuerich Construction Pull-out strength displacement (at load of 75 KN) 08 0921-CPD-2056 EN 1504-6 Anchoring Product dry concrete wet concrete 0.6 mm 0.6 mm Glass Transition temperature 45 C Creep under tensile load Displacement (after continuous loading of:) 50 kn for 3 months 0.6 mm Reaction to fire Euroclass E Dangerous substances: (comply with 5.3) None 1) Last two digits of the year in which the marking was affixed 2) Identification number of the notified body 3) Number of the EC Certificate 4) Number of European standard 1) 3) 4) Sika Yapı Kimyasalları A.Ş. Deri Org. San. Böl. 2. Yol J 7 Parsel, Aydınlı, Orhanlı Mevkii, 34957 Tuzla, İstanbul, Türkiye Çağrı Merkezi Telefon Faks bilgi@tr.sika.com +90 216 444 74 52 +90 216 581 06 00 +90 216 581 06 99 www.sika.com.tr 6-3+ 6/6