Extending PCIe NVMe Storage to Client. John Carroll Intel Corporation. Flash Memory Summit 2015 Santa Clara, CA 1

Similar documents
The Transition to PCI Express* for Client SSDs

NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies

Intel Desktop public roadmap

Hetero Streams Library 1.0

Enclosure Management Cabling Guide for Intel C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

Intel Core i5 processor 520E CPU Embedded Application Power Guideline Addendum January 2011

The Case for Rack Scale Architecture

Intel Unite. User Guide

White Paper: M.2 SSDs: Aligned for Speed. Comparing SSD form factors, interfaces, and software support

Mini PCIe SSD - mpdm. RoHS Compliant. Product Specifications. August 15 th, Version 1.0

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

Intel Desktop Board DP55WB

Intel SSD 520 Series Specification Update

Intel Technical Advisory

BSP for Windows* Embedded Compact* 7 and Windows* Embedded Compact 2013 for Mobile Intel 4th Generation Core TM Processors and Intel 8 Series Chipset

Intel Media SDK Library Distribution and Dispatching Process

PCIE 16X CONNECTOR BOARD ROUTING RECOMMENDATIONS TABLE OF CONTENTS

Hadoop Applications on High Performance Computing. Devaraj Kavali

Intel Solid-State Drives Increase Productivity of Product Design and Simulation

New Dimensions in Configurable Computing at runtime simultaneously allows Big Data and fine Grain HPC

Page Modification Logging for Virtual Machine Monitor White Paper

EHCI Removal from 6 th Generation Intel Core Processor Family Platform Controller Hub (PCH)

WHITE PAPER. LVDS Flat Panel Display Interface on Intel Desktop Boards. July 2009 Order Number: E

Enterprise SSD Form Factor

Next-Gen Big Data Analytics using the Spark stack

Intel RAID RS25 Series Performance

Vendor Update Intel 49 th IDC HPC User Forum. Mike Lafferty HPC Marketing Intel Americas Corp.

Intel Desktop Board DG43NB

Thin Mini-ITX Component Catalog Q3, 2012

Intel Atom Processor E3800 Product Family

Intel Desktop Board D945GNT

PCI Express TM Form Factors: Card, Mini Card and ExpressCard*

Torpedo Design Concept Storage Server for Open Rack Hardware v0.3 ST-draco-chimera-0.3

PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector

SATA Evolves SATA Specification v3.2 FMS 2013

Family 12h AMD Athlon II Processor Product Data Sheet

Intel Extreme Memory Profile (Intel XMP) DDR3 Technology

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

Intel Data Migration Software

COSBench: A benchmark Tool for Cloud Object Storage Services. Jiangang.Duan@intel.com

Extended Attributes and Transparent Encryption in Apache Hadoop

Intel Desktop Board DG45FC

Cloud based Holdfast Electronic Sports Game Platform

Intel IoT Gateways: Publishing Data to an MQTT Broker Using Python

Intel architecture. Platform Basics. White Paper Todd Langley Systems Engineer/ Architect Intel Corporation. September 2010

Transmission of High-Speed Serial Signals Over Common Cable Media

Intel RAID Controllers

Intel Solid-State Drive Pro 2500 Series Opal* Compatibility Guide

Mini-ITX Addendum Version 2.0 To the microatx Motherboard Interface Specification Version 1.2. October 2010

Monthly Specification Update

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Intel Solid-State Drive Data Center Tool User Guide Version 1.1

CHENBRO. RM Port 6Gb/s Mini-SAS Backplane 80H A0. User s Manual. Sep / 30 / 2010

AN CBTL02042A switching application for msata and PCI Express Mini-Card. Document information

Intel Desktop Board D945GCZ

RAID and Storage Options Available on Intel Server Boards and Systems

Intel Desktop Board DG965RY

Intel Solid State Drive Toolbox

Intel Desktop Board DQ45CB

Intel Desktop Board D101GGC Specification Update

Intel Desktop Board D945GCPE

Intel Core TM i3 Processor Series Embedded Application Power Guideline Addendum

Intel RAID SSD Cache Controller RCS25ZB040

Intel Server Chassis P4304XXSHCN/P4304XXSFCN/P4000XXSFDR

Version Rev. 1.0

Intel Solid-State Drive 320 Series

Intel Data Center Manager. Data center IT agility and control

Mini-ITX Addendum Version 1.1 To the microatx Motherboard Interface Specification Version 1.2. April 2009

Intel Desktop Board DQ35JO

Intel Desktop Board DG41BI

Intel Desktop Board DG43RK

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

PCI Express Supersedes SAS and SATA in Storage

with PKI Use Case Guide

Intel Desktop Board D945GCL

Enabling Innovation in Mobile User Experience. Bruce Fleming Sr. Principal Engineer Mobile and Communications Group

Specification Update. January 2014

Intel Desktop Board D945GCPE Specification Update

Intel Solid State Drive Toolbox

Intel Desktop Board DG41TY

Intel Desktop Board D925XECV2 Specification Update

Intel Desktop Board DG31PR

21152 PCI-to-PCI Bridge

SATA Express. PCIe Client Storage. Paul Wassenberg, SATA-IO

Can Flash help you ride the Big Data Wave? Steve Fingerhut Vice President, Marketing Enterprise Storage Solutions Corporation

Intel Cloud Builder Guide: Cloud Design and Deployment on Intel Platforms

RAID and Storage Options Available on Intel Server Boards and Systems based on Intel 5500/5520 and 3420 PCH Chipset

Three Paths to Faster Simulations Using ANSYS Mechanical 16.0 and Intel Architecture

Intel Identity Protection Technology (IPT)

Intel Desktop Board DG31GL

Jun Liu, Senior Software Engineer Bianny Bian, Engineering Manager SSG/STO/PAC

Intel 815 Chipset Platform for Use with Universal Socket 370

Power Benefits Using Intel Quick Sync Video H.264 Codec With Sorenson Squeeze

How High Temperature Data Centers and Intel Technologies Decrease Operating Costs

Intel Desktop Board DP43BF

Intel Desktop Board DG33TL

Mini Computing : Optimizing Design to Accelerate New Usage Models

AW-NE785. IEEE b/g/n PCIE Mini-Card Wireless Module. Datasheet. Version draft 0.9. PID,VID, SVID, SSID, Antonio. FW version.

Transcription:

Extending PCIe NVMe Storage to Client John Carroll Intel Corporation Flash Memory Summit 2015 Santa Clara, CA 1

No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. This document contains information on products, services and/or processes in development. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest forecast, schedule, specifications and roadmaps. The products and services described may contain defects or errors known as errata which may cause deviations from published specifications. Current characterized errata are available on request. You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. Forecasts: Any forecasts of requirements for goods and services are provided for discussion purposes only. Intel will have no liability to make any purchase pursuant to forecasts. Any cost or expense you incur to respond to requests for information or in reliance on any forecast will be at your own risk and expense. Business Forecast: Statements in this document that refer to Intel s plans and expectations for the quarter, the year, and the future, are forward-looking statements that involve a number of risks and uncertainties. A detailed discussion of the factors that could affect Intel s results and plans is included in Intel s SEC filings, including the annual report on Form 10-K. Tests document performance of components on a particular test, in specific systems. Differences in hardware, software, or configuration will affect actual performance. Consult other sources of information to evaluate performance as you consider your purchase. For more complete information about performance and benchmark results, visithttp://www.intel.com/performance. Copies of documents which have an order number and are referenced in this document may be obtained by calling 1-800-548-4725 or by visitingwww.intel.com/design/literature.htm. Intel, the Intel logo are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others 2015 Intel Corporation. Flash Memory Summit 2015 Santa Clara, CA 2

Agenda Background on Storage Form Factors Using the same U.2 drives in Data Center and Client Power usage and time to throttle

Storage Form Factor Overview Small form factor BGA SSD msata M.2 2.5 and 3.5 SATA* (2.5 /3.5 ) SATA Express Device U.2 SSD Add in Card PCIe add-in card (CEM)

Client Storage Background Devices are getting smaller, thinner, and lighter Client storage continues to get smaller High performance and capacity still expected in small form factors

PCIe Client Storage Form Factors Add-in-card 2.5 drives M.2 BGA Higher performance (up to 16 lanes) Legacy form factor Higher thermal capabilities Disadvantage: size Flexibility for SSDs, SSHDs, and HDDs High performance (U.2 up to PCIe x4, Sata Express PCIe x2) Cabled solution for larger platforms Smallest PCIe SSD with a connector SATA* or up to PCIe x4 Prefer 30mm and 80mm length Ideal for small and thin platforms Up to PCIe x4 Prefer 11.5x13mm and 16x20mm

Agenda Background on Storage Form Factors Using the same U.2 drives in Data Center and Client Power usage and time to throttle

Objective: The same U.2 drives in Data Center and Client U.2 SSD Source: http://hyvesolutions.com/solutions/ambient/

U.2 Host (SFF-8643) Pinout Vendor Specific in Data Center U.2 Host (SFF-8643) Connector Proprietary minisas HD Cable U.2 Host (SFF-8643) Connector U.2 (SFF-8639) Connector Motherboard Backplane Data center uses additional pins on the host connector in a proprietary way The pinout for the U.2 Host Connector used in data center varies per platform The U.2 connector and pinout on the backplane is standard

A Consistent U.2 Host Pinout and Cable is Required for Client The same U.2 Host connector is used in client, but a different pinout Motherboard, cable and SSDs each come from different vendors The host connector and cable need to be standard The connector and pinout for the drive remains the same for both client and data center U.2 Host (SFF-8643) Connector U.2 SSD U.2 Cable Motherboard SATA* power connector U.2 Connector

More on the Client U.2 Host Connector Pinout 3 4 5 6 7 8 9 D GND PETp0 PETn0 GND PETp2 PETn2 GND C GND PETp1 PETn1 GND PETp3 PETn3 GND B GND PERp0 PERn0 GND PERp2 PERn2 GND A GND PERp1 PERn1 GND PERp3 PERn3 GND D1 C1 B1 A1 D9 C9 B9 A9 7 pins per row used for PCIe lanes (pins 3-9) 1 2 D SMBus Data SMBus Clk C Reserved Reserved B PERST# CLKREQ# A REFCLK+ REFCLK- 2 pins per row used for sideband signals (A1, A2,, D1, D2) Intel releasing a whitepaper with more info

Agenda Background on Storage Form Factors Using the same U.2 drives in Data Center and Client Power usage and time to throttle

Temperature, C Importance of Power usage on Client Storage With smaller form factors, thermals can be more challenging High activity and power usage could lead to SSDs throttling sooner Max power and idle power are two levers to adjust time to throttle Max power determines worst case time to throttle Low idle power reduces temperature in typical client workloads Consider data to throttle instead of time to throttle Time to throttle * performance 140 130 120 110 100 90 80 70 60 50 40 30 20 August Ridge: Estimated Thermal-Time Profile Max Workload (4.5W), Passive cooling only, 35 C ambient, No system-level cooling provisions Time to Throttle 0 60 120 180 240 300 Time, seconds Example based on Intel internal model for a BGA SSD

M.2 Provides Flexibility for M.2 or U.2 M.2 to U.2 adapters enable flexibility for M.2 SSDs or U.2 cabled solutions Enables flexibility to support SSD/SSHD/HDDs in the same M.2 connector Allows for larger form factor drives which may use more power without a motherboard change M.2 to U.2 Host Adapter

Summary Client platforms and storage form factors continue to get smaller Going forward, innovation on physical size as important as performance for client Add-in-cards, 2.5 drives, M.2, and BGA are leadership PCIe solutions