The first apartment house renovation with Passive House components in Norway



Similar documents
Norwegian Tax Authority - Oslo Norway

Passive House Projects in Norway an Overview

Case study on residential building renovation and its impact on the energy use and thermal comfort

Klosterenga, Oslo, Norway, page - 1

Passive house rehabilitation of post war residential building in Zug, Switzerland

2014 British Columbia Building Code Changes

Innovative solution for heat recovery of ventilation air in older apartment buildings - with low intervention affecting the residents

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards

THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes

9 Energy management. 9:1 General. BFS 2011:26 BBR Oct. 9:11 Scope of application

Residential HVAC System Sizing

Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

RESNET National Rater Test Study Guide Outline

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Existing Housing Stock

Energy savings in the residential area are essential in

Rosslare Case Study Passive House Cost Analysis. Seamus Mullins Quantity Surveyor Michael Bennett Group

Before You Start an Energy Efficiency Retrofit The Building Envelope

Energy Efficiency in Buildings

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

BER Assessors Dwellings Technical Bulletin

Isover Multi-Comfort-House Comfort and Energy Efficiency in Buildings

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

D5.3 Energy audit report

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Twinning «Improvement of the Energy Efficiency in Turkey»

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

The Government s Standard Assessment Procedure for Energy Rating of Dwellings

Improving thermal insulation of concrete sandwich panel buildings

3.14 <NL> The Netherlands

Franciscan Monastery, Graz, Austria

THE IC Y N E N E AD V A N T A G E

Performance of 8 Passive House Envelopes in Cold Climates

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

BEST 3, Atlanta, April 2012 Grahame E. Maisey, P.E.

energy-saving checklist a guide for rental property owners

Building Energy Modelling. prescriptive

Mechanical and Natural Ventilation

FABRIC ENERGY EFFICIENCY FOR PART L 2013

School in Schwanenstadt, Austria

Heating and Ventilation

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

1..GENERAL DATA 2. CLIMATIC DATA. Location

FLORIDA SOLAR ENERGY CENTER

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

PROBIS SUPPORTING PUBLIC PROCUREMENT OF BUILDING INNOVATIVE SOLUTIONS

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Selecting Energy Efficient New Windows in Georgia

Energy audit in Finland

3-D Modeller Rendered Visualisations

Selecting Energy Efficient New Windows in Arizona

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

HEATING-COOLING WALL PANELS SYSTEM IN SLOVENE ETHNOGRAPHIC MUSEUM

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

ZERO CARBON HOMES AND NEARLY ZERO ENERGY BUILDINGS. UK Building Regulations and EU Directives

Energy Efficient HVAC-system and Building Design

Selecting Energy Efficient New Windows in Texas

Module 3.7. Thermal bridging

City of Cornwall Social Housing Division Top 10 Energy & Water Saving Tips. in Multi-Unit Residential Buildings

ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ

Directorate for the Built Environment Building Standards Division

HVAC Code Requirements

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Case Studies in Existing Building Audits

Kvernhuset Lower Secondary School

Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows

Energy efficiency building standards in Japan

ROOFS, SNOW AND ICE DAMS

Affordable Zero Energy

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

Enclosing Timber Frames. Panels. Frank Baker Founder, Riverbend Timber Framing and Insulspan

Energy Concept and Technology in the Rosenheim Solar Decathlon House

Clean Energy Solutions Center IEA Technology Roadmap: Energy Efficient Building Envelopes Launch

Introduction to DEAP for Professionals DWELLING ENERGY ASSESSMENT PROCEDURE (DEAP)

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

Transcription:

14th International Passive House Conference Dresden, May 28, 2010 Michael Klinski Tor Helge Dokka The first apartment house renovation with Passive House components in Norway

168 flats, onebedrooms (55 m²) and twobedrooms (68 m²) 7 similar blocks, 3 storeys high with unheated cellar, built 1968-70 Myhrerenga housing cooperative at Skedsmokorset, 15 km north east of Oslo, nearly same climate with annual mean temperature around 6 C 2

Fine and sad

Cracks Many damages Rot Moisture 4

Myhrerenga before renovation Complaints about poor indoor climate, draft problems and cold floor Exhaust ventilation system Central heating with radiators High energy consumption (275 300 kwh/m²år, overall) 2006: The cooperative wants a facade rehabilitation and larger balconies Housing Bank and SINTEF suggest retrofit with PH-components Demonstration project within EKSBO and IEA SHC task 37 Construction work starts in February 2010 5

Building fabric before renovation 5 10 cm insulation in floors towards cellar, walls and roof construction Poor air tightness Lot of thermal bridges

Renovation concept Added insulation in cellar ceiling, walls and roof Passive House windows and doors Increased air tightness and reduction of thermal bridges Highly efficient balanced ventilation Replacement of oil and electric boilers with air to water heat pumps and solar collectors Reuse of existing heat distribution system Individual energy accounting (heat and electricity) 7

Airtight building envelope including staircase in the cellar

Many details to design Insulation Insulation blown in Airtight building envelope No insulation below, but on wall including staircase in the cellar

Air tightness: expanding foam caulking Test wall

PH-window and vapor permeable wall Existing construction Air tightness: expanding foam caulking Arkitektskap AS OSB-boards and 20 cm unbroken insulation on the existing 10 cm stud wall + new facade lining

Airtight window/wall solution after discussion on-site Existing construction

Insulation blown in Air tightness measures: Existing construction Air tightening OSB frame and between stories Roof and balcony

Balcony and window/door Air tightness measures: Balcony supports Existing construction

Calculated U-values [W/m²K] Construction External walls main façade External walls gable Roof Floor construction* Windows and balcony doors Entry doors U-value before renovation 0.40 ~ 0.45 0.35 0.58 2.8 2.7 U-value after renovation 0.12 0.15 0.11 0.23 0.80 1.20 * U-value included the thermal resistance of the unheated cellar

One central air handling unit per block, placed in the cellar Double cross flow heat exchanger (probably) with high efficient heat recovery ( > 80 %, SFP < 1,5 kw/m³/s Air supply through old garbage chute Air extract through existing extract shaft Balanced >> limited interior work ventilation 16

Energy supply Only one radiator in the living room (1-1,5 kw) + existing radiator in the bath room Individual energy accounting (heat and electricity) Renovated boiler house: 3 air-to-water heat pumps (25 kw each, run in cascade) 44 vacuum solar collectors on the nearest block roof 1 electric boiler kept (peak load) Reuse of existing heat distribution system

New and larger balconies Arkitektskap AS

New entrances Arkitektskap AS

Calculated energy demand Energy Demand [kwh/m²a] Space Heating DHW Fans and pumps Electricity use (lighting and appliances) Sum * Varying from year to year ** To be measured after renovation Before renovation (measured)* 195 220 30 10 40 275 300 After renovation** (simulated) Net energy demand 25 30 10 40 105-88 % Delivered energy 15 15 10 40 80-72%

Increased investment cost for PH-retrofit, in addition to façade renovation but... Project cost million NOK Cost NOK/m² Cost EUR/m² Overall construction cost 70.0 6430 800 Design + construction supervision 4.5 410 50 Overall investment cost PH-retrof. 74.5 6840 850 Conventional façade renovation 53.8 4940 615 Gross additional cost PH-retrofit 20.7 1900 235 Allowances from ENOVA 6.4 590 75 Net additional cost PH-retrofit 14.3 1310 160 VAT included

lower rent per month

and additional advantages like: Increased comfort and indoor climate Lower maintenance cost Substantially higher marked value for the flats, maybe increased by 2000 kr/m² Preliminary conclusions: Cost effective renovation with PH-components is possible in Norwegian average climate Decision making and design/optimization process is more challenging than in Central-Europe