AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction



Similar documents
4 Stage Barracuda RO/DI Instruction & Owner s Manual

FILLING AND PURGING THE SYSTEM

Overheating limit control

Watts Pure Water Systems

Stenner Pump Chlorinator Installation & Start Up Guide

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

LABORATORY PRODUCT GUIDE

ACCUMULATOR INSTALLATION

PRICE LIST Brutto incl.moms Januar 2011

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Drinking water for Gaza Elaboration concept 2

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Water Treatment and Reverse Osmosis Systems

Model 5600 & 5600 Econominder

Model 5600SE Downflow

Centro-Matic Automatic Lubrication Systems System Controls

A meaningful, cost-effective solution for polishing reverse osmosis permeate

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Example. Fluid Power. Circuits

Model 5600 & 5600 Econominder

RiOs 3, 5, 8 Water Purification Systems

Please keep these operating instructions in a safe place.

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

RO Reverse Osmosis equipments

ELECTRIC CENTRAL HEATING FLOW BOILER

Energy Recovery Device isave 21-40

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

How To Replace A Reverse Osmosis Water Tank

Troubleshooting Salt Generators

WHOLESALE DIRECT INC WEST 65TH STREET

Master Programming Manual for TotalCare, CareSoft Elite, CareSoft Pro, Ion Pro and CareClear Pro Models

OPERATING AND MAINTENANCE MANUAL

VOYAGER 570G. 744A Sprayer Control

Direct Water purification system Pure & ultrapure water directly from tap water

Service and support. Did you know? Table of Contents. Less weight, lower fuel costs, higher speeds. Fresh water wash downs

Compressor Service & Maintenance Manual

Owner s Manual / 5600 Econominder

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

EcoSoft Water Softener. General Installation Guide

THE RO+UV Water Purifier USER MANUAL

PWC-500/1000/1010/1500

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Cartridge Filter Application Notes

Pro Logic Version Diagnostics Manual

Automatic Self-Cleaning Strainers

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Designed for multi-injector endurance testing, the

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Kompressoren. Adsorption Dryer AD

OPL BASIC. Dosing System for Professional Laundry machines. Contents

TECHNICAL SPECIFICATIONS

PROGRAMMABLE LOGIC CONTROL

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

What Is Membrane Performance Normalization?

Automation & Sanitization REPLACEMENT PARTS

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Medical Air Systems: Scroll

Watts Family of water quality improvement products and equipment for whole house water treatment.

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

SECTION 11 drinking Water Systems

DIESEL FUEL CONDITIONING

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

GEBCO (PTY) LTD - Netafim Product List - 1st August 2011

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Electrodeionization (EDI)

12 Volt 30 Amp Digital Solar Charge Controller

SECURITY SYSTEM ADP-CAN

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Telefon (+45) Telefax (+45) Installation and operating manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

HERZ-Thermal Actuators

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS

OS Instruction Manual. Electronic Controllers for Reverse Osmosis Plants. Software version

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Portable Swimming Pool Reverse Osmosis Systems

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

INSTRUCTIONS MANUAL PROLINE PLUS PROLINE PLUS PUMP

Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance

Power consumption (kw)

DC Motor control Reversing

Autotrol 460i and 460TC Control System

Aqua Rite & Aqua Rite XL Diagnostics Manual

Troubleshooting Your RO

Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60

10/20 COMBINATION UNIT

User s Manual Before using the inverter, you need to read and save the safety instructions.

Transcription:

Reverse Osmosis Parts Introduction

Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2

Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W) (B) (R) White Black Red GROUNDING Blue Brown ON/ OFF SWITCH Green Black MEMBER W A T E R QUALITY A S S O C I A T I O N Control Box PUMP FLUSH SOURCE FULL POWER R MANUAL WATER FLUSHING CONTROL Green Blue Blue Full water switch TO FLOATING / H.P. SWITCH Yellow Yellow 2T1 1 5 6T3 T O C Red Red Black YELLOW/GREEN A2 MC 95 Flushing Solenoid Valve : Red 1 3 BROWN BLUE Magnetic Switch : Green ( A2, 95) Low Pressure Switch : Yellow Electrical Pressure valve INLET DUAL T.D.S. WATER ON/OFF OUTLET RO PUMP U1 W2 Red 2T1 T.D.S. TEST BAR INLET WATER T.D.S. TEST BAR PURIFIED WATER V1 U2 W1 V2 Black 6T3 RO Pump internal wiring 3

Reverse Osmosis Specification Filter Housing with Cartridges 20" Filter Housing 20" Cartridge: Sediment 5, 1micron Carbon Block Carbon Block Vertical Pump Type: 3HP 4HP 5.5HP Actuator Shutting down while Low pressure switch sends out signal. 1". Solenoid Valve Flushing while control box sends out flushing signal. 1500-2000GPD: 1/2" 3000-4000GPD: 1/2" 4500-6000GPD: 1/2" 6000-8000GPD: 3/4" 10000GPD: 3/4" 4

RO Membrane & RO Housing (A) RO Membrane Housing (B) RO Membrane: 1.Specification of Membrane (1) Max. Operation Pressure: 300PSI O (2) Max. Operation Temperature: 45 C (3) Turbidity (NTU): <1 (4) Chlorine: 0.1PPM (5) PH Range: 2~11 (6) Flow Rate: 10GPM (7) Max. S.D.I. Index: 5 (8) Salt Rejection Rate: 96% 2.Application Data For System Design: (1) Max. Operation Pressure: 190~220PSI O (2) Max. Operation Temperature: 45 C (3) Turbidity (N.T.U.): <1 (4) Chlorine: <0.1PPM (5) PH Range: 4~11 (6) System Inlet Water pressure: 3.5KG+/- 15% (7) Max. S.D.I. Index: 4 (8) Salt Rejection Rate: 96% (9) Product Water Generate: 25% O (C) Testing Environment: 25 C/pH=8 (1) NaCl: 2000 PPM (2) Operating Pressure: 225PSI (3) Recovery Rate: 15% 600PSI` AQUAPRO INDUSTRIAL CO.,LTD Reverse Osmosis Specification Water Inlet pressure Gauge 2 0~15 KG/CM Oil-Filled Pressure Gauge 2 *Not allow to operate under 1.5KG/CM * RO Inlet Water Pressure Gauge 2 0~35KG/CM (30bar)Oil-Filled Pressure Gauge, set the pressure between 150~180PSI to get the maximum performance. Pressure Regulator Adjust Clockwise to boost RO operating pressure, Counterclockwise to Lower operating pressure. Gate Valve Only for vertical pump using. 5

Flow Meter AQUAPRO INDUSTRIAL CO.,LTD Reverse Osmosis Specification 0.2~2GPM 0.5~5GPM 1.0~10GPM 2.0~20GPM Microprocessor Controller Electromagnetic Switch 1HP FOR 1/2 HORSE POWER MOTOR (Single Phase) 3HP FOR 1 HORSE POWER MOTOR (Single Phase) 5HP FOR 3 HORSE POWER MOTOR (Single Phase) 7.5HP FOR 4 OR 5 HORSE POWER MOTOR (Three Phase) Model: MC-2---Six lights microprocessorized automatic flush controller. Power: 230VAC, 50/60Hz, or 24VDC Function: Controller processing steps: (1) Automatically flush for 1 minute and 30 seconds when the machine starts its first time. (2) Water-generating detection: Automatically flush for 1 minute and 30 seconds after the accumulated time reaches 12 hours. (3) Input water detection: It will not start control system (stop pump/solenoid valve) if the low pressure switch delays for 5 seconds (out of source water). (4) Output water detection: When production water is full, Full water lamp is on and stop pump/solenoid valve. Configurations: Water-generating Water-input Full-water Power Pump Flush Sorce Full INDICATION OF EACH LAMP: PUMP: Water-generating, will be on when pump is generating. FLUSH: Auto flush function, will be on when it is flushing automatically. SOURCE: Water-input, will be on when it is short of water. FULL: Full-water, will be on when water tank if full. POWER: Will be always on. MANUAL: Manual flush function, will be on when flushing by manual. WRING INSTRUCTION: 1. Low Pressure Switch- YELLOW with AMP connector 2. Floating/Pressure Switch-BLUE with AMP male connector 3. Flushing Valve-RED with AMP connector 4. Booster Pump-GREEN/BLACK With AMP connector 5. Inlet Valve-GREEN/BLACK With AMP connector 6 Manual

Reverse Osmosis Installation Reminder 1. Make sure the voltage and phase of the system you order, never use wrong setting. 2. Check the pure/concentration water are piping right. 3. The power line core should large enough (not less than 3.5 mm) 4. Be ware do not let brine flow through the system while water softener is backwashing. 5. Make sure the water softener's In/Out are connected correct. 6. Measure feed water pressure with a water pressure gauge. Feed water pressure is preferably to be 35 psi and the minimum is 26 psi. If lower than 26 psi, it should install a booster pump at the feed water location. 7. Check prefilters every week to make sure the water supply. 8. If the equipment comes with Ultraviolet Device, make sure you have a steady Power supply in protection of the U.V. Lamp. Replacement of Filter Cartridges The replacement of filter cartridges depends greatly on the quality and condition of the water in local area where the reverse osmosis system is placed. Please follow the instructions below to ensure good performance of the system. 1. It is most recommended to replace the filter cartridges every three months. 2. After a while's usage, check regularly Reverse Osmosis Panel's Inlet Water Water Pressure Gauge. If its water pressure is 15% lower than the feed water Pressure, it is recommended to replace the filter cartridges. E.g. If the feed water pressure is 2bar (35psi), and the Inlet Water Gauge's Index is 1.7bar (29psi), it is recommended to replace the filter cartridges. 7

Reverse Osmosis Setup Suggestion 1. If possible, install the active carbon filter and water softener to ensure the incoming water quality. 2. Water softener should regenerate the resin by adding salt to its salt tank. Do it regularly. 3. If not install the water softener, lower the pure/concentration water ratio by adjusting the pressure adjust needle valve(ro Needle Valve). 4. Change pure/concentration water ratio, you should always notice the motor operating pressure, adjust it from the PROCON bypass to ensure the motor is running at the best condition. 2 5. If your water incoming pressure lower than 1 kg/cm, remember to add a pump in front of the system. 6. The lines left on side of autoflushing timer are used for level control or high pressure switch (If you are using a pressurize storage device). 7. Please use Hardness Tester (5B) to know your water hardness. Make sure the water softener is working fine. 8. Please use the Chlorine Tester to detect the active carbon's working condition, change active carbon when necessary. 9. Cleaning R.O. membrane when the product rate declined 10% or pressure drop up 15%, the following figure tell you how: a. Take pure water pipe (O) out and put it into drain. b. Put concentration water pipe (P) into cleaning solution (Q). c. Start pump (Notice: Make sure to release the air gather in pipes). d. Close (M) valve, open (N) valve, let cleaning solution suck into R.O. system. e. Adjust needle valve (Pressure adjusting valve) to the maximum level. And let it run for 30 minutes. After 30 minutes, adjust pressure to 60 psi, run for another 30 minutes. f. Put concentration water pipe back to the drain, adjust pressure to maximum level, flush for 1 minute and it's done. Note: Using the right cleaning solution to clean different types of scale, the cleaning solution O PH should range from 3 to 10 at temperature of 35 C. 8

ROUTE FOR ACTUATOR F M T O C INPUT OPEN CLOSED 9

Reminder 1. INLET PIPING SIZE (1) 1500~2000GPD, 1Membrane Inlet Piping: 3/4" ~ 1" (2) 3000~4000GPD, 2 Membranes, 1HP Motor, Procon Pump Inlet Piping: 3/4" ~ 1" (3) 3000~4000GPD, 2 Membranes, 3HP, Grundfos Pump Inlet Piping: 1" (4) 6000~14000GPD, 4 ~ 8 Membranes Inlet Piping: 1" ~ 1-1/4" 2. INSTALLATION OF AN ADDITIONAL PUMP The inlet water pressure must be at least 1.5kg / cm2. When inlet water pressure is under 1.5kg/cm2, equip the system with an additional pump to increase the inlet water pressure. The selection of the additional pump must be based on actual Situations. 10