Water Treatment and Reverse Osmosis Systems

Troubleshooting Your RO

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Basics of Reverse Osmosis

RO / NF Cleaning Guidelines

Wastewater Reuse. Typical treated wastewater is:

1. Inspection and monitoring... 3

Water Info. What is Reverse Osmosis?

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

Drinking water for Gaza Elaboration concept 2

Best Practice in Boiler Water Treatment

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

Reverse Osmosis Membranes for Wastewater Reclamation By Craig R. Bartels, PhD Hydranautics, 401 Jones Road, Oceanside California, USA 92054

Portable Swimming Pool Reverse Osmosis Systems

Rotary screw compressors kw 5,5 7, , bar MODULO

VIPCLEAN Via Goretta 96/A Mappano di Caselle (TO) Tel Fax

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

THE USE OF OZONE IN COOLING TOWERS

Complete. Water Solutions. for Rural India

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Ultra Violet Disinfection

Power consumption (kw)

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

Case Study: Optimizing Scale Inhibition Costs in Reverse Osmosis Desalination Plants

LABORATORY PRODUCT GUIDE

Hydraulic Control Solutions

PRICE LIST Brutto incl.moms Januar 2011

Hydranautics. RO Water Chemistry

drinking water medication short guide

The Grand Miramare Hotel Santa Margherita (Portofino) Italy March 19 22, Inspiring Innovation and Excellence

FVA/A1 saturated-steam sterilizer

2014 Service Technician Training Program Closed Loop Systems

Lenntech Tel Fax

CHEMICAL CLEANING EXPERIMENTS FOR PERFORMANCE RESTORATION OF NF MEMBRANES OPERATED ON SEAWATER FEED 1

Culligan Exchange Tank Deionization Service

7. TECHNICAL ASPECTS OF DESALINATION PLANT

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

A meaningful, cost-effective solution for polishing reverse osmosis permeate

Alfa Laval PureBallast 3.1

Use of Color Removal Membranes on Waste Water Treatment in the Pulp and Paper Industry

MEMCOR membranes for drinking water applications. Water Technologies

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings

8 Chemicals from water treatment and distribution

Water... The essence of life

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

Desalination Systems for Yachts, Boats and Motor Homes

More inside :: Tackle even the toughest water treatment piping challenges with

EcoCWave. The all-round talent for aqueous part cleaning.

WATER TREATMENT GLOBAL PRODUCT SELECTION GUIDE

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Life Sciences USD High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs

A Guide to Trouble-Free Cooling Towers

ACO Cleaning principles for drainage

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Vacuum drying oven for non-flammable solvents

Comparison of multiple port and end port connections for pressure vessels

Water Equipment Technologies. Advanced Membrane Technologies for Solving Worldwide Water Problems

BROADFIELD SECURITY SERVICES WATER FILTRATION AND PURIFICATION SOLUTIONS

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Conductivity and TDS Meters

Direct Water purification system Pure & ultrapure water directly from tap water

PERFECT TECHNOLOGY MAKES THE DIFFERENCE JUDO REFERENCES

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Water Treatment & Purification Chemicals

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Subject: Technical Letter 22 April 1977 Removal of Water Supply Contaminants -- Copper and Zinc

SANIC SEDIMENT CARTRIDGES

7 Years Operation of BWRO Plant with Raw Water from Coastal Aquifer for Agriculture Irrigation

FILMTEC Membranes Strategies for Using FILMTEC Elements to Lower Your Total Cost of Seawater Desalination

Kompressoren. Adsorption Dryer AD

Water Treatment NOTES. Cornell Cooperative Extension, College of Human Ecology. Reverse Osmosis treatment of Drinking Water

FAMILY PROTECTION FROM WATERBORNE DISEASES

Reverse Osmosis (RO) Drinking Water System. Product Manual

Lenntech. Dow Water Solutions. FILMTEC Membranes. Product Information Catalog

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Electric Flow Boiler

Clinic Washer-Disinfectors. Washer-Disinfector Line

Removing biofilm from membranes a practical approach.

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

HOSE, TUBE, AND PIPE CLAMPS

Membrane filtration for sanitary use. The complete line

REVERSE OSMOSIS WATER SYSTEM FOR INDUSTRIAL USE

AQUADA UV Eliminate Bacteria in Your Drinking Water!

SIMPLE... AFFORDABLE... ENERGY EFFICIENT... LOW MAINTENANCE...

Stenner Pump Chlorinator Installation & Start Up Guide

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Ozone in Cooling Towers : Hygiene for us

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

SECTION 11 drinking Water Systems

Cartridge Filter Application Notes

REVERSE OSMOSIS PROCESS AND SYSTEM DESIGN. H. Ohya Department of Chemical Engineering, Yokohama National University, Japan

Pall Aria AP Series Packaged Water Treatment Systems

Workshop Compressors CLASSIC Series

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

Transcription:

RO SYSTEMS RO Reverse Osmosis equipments A range of Reverse Osmosis equipment designed to provide the highest performances with flow rates demand from 50 to 1000 l/h. Every component of the equipment is sourced to provide the most advanced, most reliable solutions in RO while flexibility on components make it possible getting a wide selection of membranes and other equipment parts to respond any requirement from low to average salinity water. RO systems can be equipped with pre- and/or posttreatment units to meet any requirement on water quality. The range is complemented with dedicated chemical products for equipment s operation and maintenance. RO units made by design and specific requirements can be provided on demand.

RO REVERSE OSMOSIS Direct Osmosis is a phenomenon that happens normally in nature, for instance in the cells of all living organisms, and it is the process where with two solutions of different concentration divided by a semipermeable membrane (that is allowing water but no salts to go through), the more diluted solution tends to move naturally towards the more concentrated solution till the concentration of the two solutions becomes the same; the pressure created on the membrane because of this flow is called Osmotic Pressure. Exploiting this principle, it is possible to reverse the process by applying a similar but adverse pressure to the concentrated solution to obtain from it a solution of lower concentration: this process is called Reverse Osmosis. The osmotic membrane carrying out the best filtering level achievable, behaves like a barrier not only against the salts and inorganic substances making up the saline composition of the water, but also against organic substances such as pesticides, pyrogens, viruses and bacteria; a nominal rejection (reduction capacity) of 100% can be reached with bacteria. The bigger the difference between the pressure applied and the osmotic pressure, the bigger is the quantity of water produced per unit of surface of semi-permeable membrane. The supply pressure required varies according to the type of water and salinity to be treated (therefore according to the relative osmotic pressure to overcome): TECHNICAL FEATURES - Domestic uses: cleaning-up of drinking water, elimination of any smells and tastes connected to the presence of chlorine or chlorine derivatives, pesticides, insecticides, fungicides, heavy metals, micro-organisms, strong reduction in salt content. - Technical uses: in all processes where demineralized water is used, production of drinking water from wells or sources with values within their operational conditions. NOTES: The system is suitable to treat water with certain chemical-physical and microbiological characteristics that might require pre-treatments, so it s always necessary to have a complete analysis of the water to be treated. - System water: from 2-3 up to 18-20 bar - Brackish water: from 7-8 up to 34-40 bar - Sea water: from 50-55 up to 70-85 bar The most suitable membrane (as far as type and dimension are concerned) must be chosen for each system, following a modular criterion, so that the chosen membrane is arranged following a system of elements in series and in parallel. A reverse osmosis membrane cannot remove 100% of salts (even if today 99.5% can be achieved) and cannot treat 100% of the supplied solution, therefore a reverse osmosis system has a Supply, a Product (also called Permeate) and a Discharge (also called Reject or Concentrate). These days reverse osmosis technology has undergone such quick development that compact, simple, versatile systems are achieved, characterized by constant output, both in terms of water produced and its quality. No civil or industrial business exists that can do without specifically treated water; from the water for boilers that must have precise chemical-physical specifications to process water (chemical and pharmaceutical, food, drink industries, etc.) that must adhere to stringent production requirements, the possibilities for use of the reverse osmosis process can be considered endless. In this sector too, reverse osmosis technology has conquered a leading role thanks to its adaptability, costeffectiveness and running simplicity. The RO reverse osmosis systems by ATLAS FILTRI use very high quality components and are designed to meet the requirements of any customer, on the basis of the analysis results of the origin water; apart from a standard range, on request ATLAS FILTRI can provide specific solutions. Every installation can be fitted with pre- and post-treatment systems; ATLAS FILTRI can boast a wide experience in the water treatment and filtering sector, with a wide range of items and equipment for both the domestic/civil and industrial sectors. CERTIFICATIONS SYMBOLS LEGEND For domestic use The products are tested and certified under the most stringent procedures worldwide, in compliance with DM 25 (Italy) and GOST (Russia). For technical and industrial use 286 RO systems

RO050.DGT - RO050.ECO Consisting of a 10 DUPLEX filtration group: first stage carbon cartridge, second stage cartridge with 5 micron filtration rate. Made up of a brass rotary vane electric pump with bypass. Consisting of high-productivity and low-consumption reverse osmosis permeator (low energy). The membrane is closed in a polypropylene vessel. Feeding, permeate, high pressure and discharge hoses in 12 bar pressure resistant material. - Pressure gauge for feed pressure at the membranes - Flow restrictor for the adjustment of the draining flow - Protection pressure switch with system lock for low - Protection pressure switch with system lock for permeator supply high pressure (only RO050.DGT version) - Permeate pressure gauge for automatic system stop - Membrane solenoid valve for system supply - Membrane solenoid valve for the of the osmosis module flushing - Conductivity probes for feed water and permeate (only RO050.DGT version) - Tank in plastic suitable for food contact (only RO050.DGT version) SUPPORT FRAME built in AISI 304 stainless steel complete with brackets, vessel and hose fixing collars, valves and connections, leads for the various uses, electric control panel. RO050.DGT - RO050.ECO PERMEATE PRODUCTION 50 LITRES/HOUR EA0500002 RO050.DGT 50 l/h 95 % 20 (%) 750 ppm 3 1 NTU MAX 2 f 0,2 mg/l ABSENT 600 x 310 x H650 mm EA0500001 RO050.ECO 50 l/h 95 % 20 (%) 750 ppm 3 1 NTU MAX 2 f 0,2 mg/l ABSENT 600 x 310 x H600 mm Min/max feed water pressure...1,5 4 bar Min/max feed water temperature...5 C 30 C Feed water minimum flow rate...400 l/h Operating pressure... 10 bar Total installed power...0,30 kw Monophase electrical supply...230 V / 50-60 Hz Supply connection...g 1/2 F Permeate / Discharge connections...ø 10 / 6 mm CONTROL PANEL RO050.DGT CONTROL PANEL RO050.ECO RO050.DGT ELECTRO-MECHANICAL CONTROL PANEL conductivity - Working hours display with maintenance block at x hours - Fluxing automatic timed and at each cycle stop - Automatic system start and stop RO050.ECO ELECTRO-MECHANICAL CONTROL PANEL - With microprocessors and status LED - Alarm with LED display for feed water low pressure - Fluxing automatic at each cycle stop 287 RO systems

RO40 - RO80 - RO120 Made with a 10 single DP filtration stage: CB EC carbon block cartridge with 5 micron filtration rate. Made up of a brass rotary vane electric pump with bypass. Made up of high-productivity and low-consumption reverse osmosis permeators (low energy). The membranes are closed in PRFV vessels capable of withstanding operating pressures of up to 21 bar. RO40: 1 membrane in 1 vessel RO80: 2 membranes in 2 vessels RO120: 3 membranes in 3 vessels Feeding, high pressure and discharge hoses in PVC PN16; permeate hoses in material suitable for pressures until 10 bar. - pressure gauge after the 5 micron filter, feed pressure at the membranes - permeate, concentrate flow sight gauge - fluxing, recirculation and discharge flow regulators - protection pressure switch with system lock for low - protection pressure switch with system lock for permeator supply high pressure - membrane solenoid valve for system supply - membrane solenoid valves for module fluxing - conductivity probes for feed water and permeate FRAME built in AISI 304 stainless steel section complete with brackets, vessel and hose fixing collars, valves and connections, leads for the various uses, electric control panel. RO40 - RO80 - RO120 PERMEATE PRODUCTION 40-80-120 LITRES/HOUR EA0500003 RO40 40 l/h 95 % 27 (%) 1000 ppm 3 1 NTU MAX 2 f 0,2 mg/l ABSENT 660 x 400 x H1430 mm EA0500004 RO80 80 l/h 95 % 45 (%) 1000 ppm 3 1 NTU MAX 2 f 0,2 mg/l ABSENT 660 x 400 x H1430 mm EA0500005 RO120 120 l/h 95 % 58 (%) 1000 ppm 3 1 NTU MAX 2 f 0,2 mg/l ABSENT 660 x 400 x H1430 mm Min/max feed water pressure...1,5 4 bar Min/max feed water temperature...5 C 30 C Feed water minimum flow rate...500 l/h Operating pressure... 12 bar Total installed power...0,30 kw Monophase electrical supply...230 V / 50 Hz Supply connection...g 1/2 F Permeate / Discharge connections...g 1/2 F CONTROL PANEL ELECTRO-MECHANICAL CONTROL PANEL conductivity / pump thermal protection operation - Working hours display with maintenance block at "x" hours - Fluxing automatic timed and at each cycle stop - Storage tank level 288 RO systems

RO200 - RO300 Made with a 10 DUPLEX filtration group: first stage carbon cartridge; second stage cartridge with 5 micron filtration rate. Made up of a brass rotary vane electric pump with bypass. Made up of high-productivity and low-consumption reverse osmosis permeators (low energy). The membranes are closed in PRFV vessels capable of withstanding operating pressures of up to 21 bar. RO200: 2 membranes in 2 vessels RO300: 3 membranes in 3 vessels Feeding, high pressure and discharge hoses in PVC PN16; permeate hoses in material suitable for pressures until 10 bar. - Pressure gauge after the 5 micron filter, feed pressure at the membranes, pressure after the modules - Permeate, concentrate and recirculation flow sight gauge - Fluxing, recirculation and discharge flow regulators - Protection pressure switch with system lock for low - Protection pressure switch with system lock for permeator supply high pressure - Membrane solenoid valve for system supply - Membrane solenoid valves for module fluxing - Conductivity probes for feed water and permeate FRAME built in AISI 304 stainless steel section complete with brackets, vessel and hose fixing collars, valves and connections, leads for the various uses, electric control panel. RO200 - RO300 PERMEATE PRODUCTION 200-300 LITRES/HOUR EA0500006 RO200 180 l/h 95 % 45 (%) 1000 ppm 3 1 NTU MAX 3 f 0,2 mg/l ABSENT 850 x 500 x H1700 mm EA0500007 RO300 270 l/h 95 % 58 (%) 1000 ppm 3 1 NTU MAX 3 f 0,2 mg/l ABSENT 850 x 500 x H1700 mm Min/max feed water pressure...1,5 4 bar Min/max feed water temperature...5 C 30 C Feed water minimum flow rate...1100 l/h Operating pressure... 10 bar Total installed power...0,55 kw Monophase electrical supply...230 V / 50 Hz Supply connection...g 3/4 F Permeate / Discharge connections...g 1/2 F CONTROL PANEL ELECTRO-MECHANICAL CONTROL PANEL conductivity / pump thermal protection operation - Working hours display with maintenance block at "x" hours - Fluxing automatic timed and at each cycle stop - Storage tank level 289 RO systems

RO500 - RO750 - RO1000 Made with a 10 HYDRA TRIO filtration group: first stage: self-cleaning 90 micron filter; second stage: carbon cartridge; third stage: cartridge with 5 micron filtration rate. Made up of an AISI 304 stainless steel vertical multistage centrifugal electric pump. Made up of high-productivity and low-consumption reverse osmosis permeators (low energy). The membranes are closed in PRFV vessels capable of withstanding operating pressures of up to 21 bar. RO500: 2 membranes in 2 vessels RO750: 3 membranes in 3 vessels RO1000: 4 membranes in 4 vessels Feeding, permeate, high pressure and discharge hoses in PVC PN16. - Pressure gauge after the 5 micron filter, feed pressure at the membranes, pressure after the modules - Permeate, concentrate and recirculation flow sight gauge - Fluxing, recirculation and discharge flow regulators - Protection pressure switch with system lock for low - Protection pressure switch with system lock for permeator supply high pressure - Membrane solenoid valve for system supply - Membrane solenoid valves for module fluxing - Conductivity probes for feed water and permeate FRAME built in AISI 304 stainless steel section complete with brackets, vessel and hose fixing collars, valves and connections, leads for the various uses, electric control panel. RO500 - RO750 - RO1000 PERMEATE PRODUCTION 500-750-1000 LITRES/HOUR EA0500008 RO500 500 l/h 95 % 30 50 (%) 1000 ppm 3 1 NTU MAX 3 f 0,2 mg/l ABSENT 900 x 700 x H1540 mm EA0500009 RO750 750 l/h 95 % 50 70 (%) 1000 ppm 3 1 NTU MAX 3 f 0,2 mg/l ABSENT 900 x 700 x H1540 mm EA0500010 RO1000 1000 l/h 95 % 50 75 (%) 1000 ppm 3 1 NTU MAX 3 f 0,2 mg/l ABSENT 900 x 700 x H1540 mm Min/max feed water pressure...1,5 5 bar Min/max feed water temperature...10 C 35 C Feed water minimum flow rate...1500 l/h Operating pressure... 10 bar Total installed power...1,5 kw Monophase electrical supply...380 V / 50 Hz Supply connection...g 3/4 F Permeate / Discharge connections...g 3/4 F CONTROL PANEL ELECTRO-MECHANICAL CONTROL PANEL conductivity / pump thermal protection operation - Working hours display with maintenance block at "x" hours - Fluxing automatic timed and at each cycle stop - Storage tank level 290 RO systems

CHEMICALS FLOCON 135 - ANTISCALANT FOR REVERSE OSMOSIS SYSTEMS Flocon 135 is an aqueous solution of a specialized phosphinocarboxylic acid, highly effective in controlling the deposition of inorganic scale forming salts on membrane surfaces. - Excellent control of carbonate and sulphate scales for cost effective operation - Compatible with all major membranes - International potable water approvals - Dispersant - Iron tolerant Flocon 135 is not affected by chlorine or other oxidizing biocides under normal conditions of use; it may be used in membrane systems using chlorine and sodium metabisulphite. Flocon 135 is an aqueous solution of an organic acid and as such is corrosive in its concentrated form. Corrosion resistant dosing equipment should therefore be used. Examples of suitable materials are 316L stainless steel, or plastics such as GRP, PVC and PE. Flocon 135 is certified to ANSI / NSF Standard 60 for use in reverse osmosis systems producing potable water. FLOCON 260 - ANTISCALANT AND ANTIFOULANT FOR REVERSE OSMOSIS SYSTEMS Flocon 260 is an aqueous solution of a specialized polycarboxylic acid, highly effective in controlling the deposition of inorganic scale forming salts and particulate fouling on membrane surfaces. - Excellent control of carbonate scales, sulphate and fluoride for cost effective operation - Effectively control both soluble and insoluble iron - Effective against silica fouling - Dispersant - Compatible with all major membranes - International potable water approvals Flocon 260 is not affected by chlorine or other oxidising biocides under normal conditions of use; it may be used in membrane systems using chlorine and sodium metabisulphite. Flocon 260 is an aqueous solution of an organic acid and as such is corrosive in its concentrated form. Corrosion resistant dosing equipment should therefore be used. Examples of suitable materials are 316L stainless steel, or plastics such as GRP, PVC and PE. Flocon 260 is certified to ANSI / NSF Standard 60 for use in reverse osmosis systems producing potable water. FLOCON B38 - SANITISER FOR REVERSE OSMOSIS SYSTEMS Flocon B38 is a fast acting high performance biocide for application as a sanitiser in reverse osmosis systems; it can also be added to the feedwater flow for predetermined times in between episodes of system sanitisation to control bio-film growth. - Fast acting - Effective at low concentrations - Effective against a broad spectrum of microorganisms - Compatible with thin film composite membranes Once or twice weekly treatments with Flocon B38 will effectively control bio-film growth. FLOCLEAN MC3 - ACID MEMBRANE CLEANER Floclean MC3 is a low ph formulation that has been designed specifically to remove metal hydroxides, calcium carbonate and other similar scales from polyamide and polysulfone membrane surfaces. - ph adjusted to 3.0+ 0.5 - Highly effective at ambient temperatures - Contains no surfactants and is quickly rinsed away - Contains organic acids, detergent builders and chelating agents It can be used at temperatures from 15 C (60 F) up to the maximum recommended by the membrane manufacturer. FLOCLEAN MC11 - BASIC MEMBRANE CLEANER Floclean MC11 is a high ph formulation that has been designed specifically to remove organics, silt and other particulate deposits from polyamide, polysulfone and thin film composite membrane surfaces. - ph adjusted to 10+ 0.5 - Highly effective at ambient temperatures - Contains no surfactants and is quickly rinsed away - Contains detergent builders, chelating agents It can be used at temperatures from 15 C (60 F) up to the maximum recommended by the membrane manufacturer. ANHYDROUS SODIUM BISULPHITE - CHLORINE NEUTRALIZER FOR REVERSE OSMOSIS MEMBRANES The chlorine neutralizer is a sodium bisulphite reducing formulation suitable to remove free and combined chlorine from supply water in reverse osmosis systems; as a matter of fact it is well known that in time the presence of free chlorine can ruin the membranes and affect the quality of the water produced by the osmosis systems. Thanks to the normal regular shutdowns, the neutralizer is suitable for maintaining the membranes of the reverse osmosis systems. Packaging: 25 kg (net weight) bags 291 RO systems