ARROW-TREROTOLA PTD. Fast and easy removal of thrombi

Similar documents
ARROW VPS G4. BULLSEYE. Hit the mark with precision and confidence

PLEUR EVAC CHEST DRAINAGE SYSTEMS. Great Innovations to Enhance Chest Drainage

Strategies to Prevent Deadly Central-Line Associated

Use of Stents and Stent Grafts to Salvage Angioplasty Failures in Patients with Hemodialysis Grafts

NI USB-6008/6009 OEM USER GUIDE

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Get the benefits of Norgren s unique range of Online services

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

Boston Scientific Spinal Cord Stimulation (SCS) Systems

10.0 FPSB s Country/region-specific Trademark Symbols and Legal Notices

Canada GO 2535 TM World Traveller's edition Maps of North America (Canada, US, Mexico), Western and Central Europe (including Russia) CAD 349,95

INSTRUMENT & ACCESSORY CATALOG

Agenda. Company Platform Customers Partners Competitive Analysis

Accuracy counts! SENSORS WITH ANALOG OUTPUT

IOOF QuantPlus. International Equities Portfolio NZD. Quarterly update

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Brochure More information from

ON OECD I-O DATABASE AND ITS EXTENSION TO INTER-COUNTRY INTER- INDUSTRY ANALYSIS " Norihiko YAMANO"

Axioma Risk Monitor Global Developed Markets 29 June 2016

THE WORLD S LEADING CAR DESIGN MAGAZINE

World Consumer Income and Expenditure Patterns

Resection, Reduction, and Revision of Aneurysmal AV Fistulas

The value of accredited certification

When Procedural Support really matters. Navien TM A+ Intracranial Support Catheter

relating to household s disposable income. A Gini Coefficient of zero indicates

Investor Presentation Q4 2015

How many students study abroad and where do they go?

Reporting practices for domestic and total debt securities

Computer Specifications

Microsoft Voucher Ordering Processes

Supported Payment Methods

Image Lab Software for the GS-900 Densitometer

BROWN BROTHERS HARRIMAN (LUXEMBOURG) S.C.A. Wells Fargo (Lux) Worldwide Fund

Review of R&D Tax Credit. Invitation for Submissions

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Supported Payment Methods

Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

How To Understand Withholding Tax In A Country

Valves for Safety Applications

endotracheal tube guide We provide Rusch quality.

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

TOWARDS PUBLIC PROCUREMENT KEY PERFORMANCE INDICATORS. Paulo Magina Public Sector Integrity Division

Configuring DHCP for ShoreTel IP Phones

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

Delegation in human resource management

PUBLIC VS. PRIVATE HEALTH CARE IN CANADA. Norma Kozhaya, Ph.D Economist, Montreal economic Institute CPBI, Winnipeg June 15, 2007

2015 Growth in data center employment continues but the workforce is changing

Paul E. Lingenfelter President, State Higher Education Executive Officers

International comparisons of obesity prevalence

BT Premium Event Call and Web Rate Card

Software Tax Characterization Helpdesk Quarterly April 2012

Hong Kong s Health Spending 1989 to 2033

Software Tax Characterization Helpdesk Quarterly June 2008

INTERNATIONAL COMPARISONS OF HOURLY COMPENSATION COSTS

Sybase Solutions for Healthcare Adapting to an Evolving Business and Regulatory Environment

Report on Government Information Requests

Brochure More information from

SunGard Best Practice Guide

To install the I/O Module Board: 1. Remove AC power from decoder.

STATISTICS FOR THE FURNITURE INDUSTRY AND TRADE

PERMANENT AND TEMPORARY WORKERS

Building a Global Internet Company: Driving Traffic to Your Site. Benjamin Edelman Harvard Business School

Report on Government Information Requests

Field Safety Notice Urgent Medical Device Correction C Cloudy Appearance and Potential Tears on System Drapes

Global Effective Tax Rates

Appendix 1: Full Country Rankings

Connected Life. Connected Life TNS

How To Get A New Phone System For Your Business

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

- 2 - Chart 2. Annual percent change in hourly compensation costs in manufacturing and exchange rates,

CISCO IP PHONE SERVICES SOFTWARE DEVELOPMENT KIT (SDK)

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: IABP (4227)

Lawson Business Intelligence. Solutions for Healthcare

How To Build A Powerline Box Powerline Generator

PUBLIC & PRIVATE HEALTH CARE IN CANADA

Global AML Resource Map Over 2000 AML professionals

BSN Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

ProteinChip Energy Absorbing Molecules (EAM)

Strategies to Reduce Catheter Use in 2014

Tax Initiatives The Common Reporting Standard

Responding to Healthcare s Most Urgent Business Issues. Gundersen Lutheran Health System Case Study

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

skills mismatches & finding the right talent incl. quarterly mobility, confidence & job satisfaction

We decided that we would build IFS Applications on standards so our customers would not be locked into any particular technology. We still do.

ORGANISATION FOR ECONOMIC CO-OPERATION AND DEVELOPMENT

Trends in Digitally-Enabled Trade in Services. by Maria Borga and Jennifer Koncz-Bruner

Employer Perspectives on Social Networking: Global Key Findings

E-Seminar. E-Commerce Internet Business Solution Seminar

1.5 GHz Active Probe TAP1500 Datasheet

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

E-Seminar. Financial Management Internet Business Solution Seminar

Purchasing Managers Index (PMI ) series are monthly economic surveys of carefully selected companies compiled by Markit.

2012 Country RepTrak Topline Report

AACSB International Accreditation and Joint Programs

How To Use An Ekosonic Endovascular System

[ Care and Use Manual ]

Expenditure and Outputs in the Irish Health System: A Cross Country Comparison

Transcription:

ARROW-TREROTOLA PTD Fast and easy removal of thrombi

ORDERING INFORMATION ARROW-TREROTOLA PTD 5 FR. Ref. Catheter length fragmentation basket sheath included rotator drive unit qty PT-03000-R 3000 rpm 1/case PT-65509* 65 cm 9 mm 1/case PT-45509** 65 cm 9 mm 2/6 Fr. 1/case PT-65509-HFC 65 cm 9 mm 2/6 (HF) Fr. 3000 rpm 1/case ARROW-TREROTOLA OVER-THE-WIRE PTD 7 FR. Ref. Catheter length fragmentation basket Max. guidewire compatibility sheath included rotator drive unit qty PT-03009-RW 3000 rpm 1/case PT-65709-W*** 65 cm 9 mm 0.025" 1/case PT-65709-WC**** 65 cm 9 mm 0.025" 2/7 Fr. 3000 rpm 1/case PT-65709-HFWC**** 65 cm 9 mm 0.025" 2/7 (HF) Fr. 3000 rpm 1/case PT-12709-WC**** 120 cm 9 mm 0.025" 2/7 Fr. 3000 rpm 1/case PTD ACCESSORY COMPONENTS INTRODUCER SHEATHS Ref. sheath size sheath length vessel dilator length Max. guidewire compatibility radiopaque tip marker LARGE-BORE- SideARM colour-coded hub CL-08505 5 Fr. 2" 5" 0.038" grey 10/case CL-08605 6 Fr. 2" 5" 0.038" green 10/case CL-08605-HF 6 Fr. 2" 5" 0.038" green 5/case CL-08705-HF 7 Fr. 2" 5" 0.038" orange 5/case qty Does not contain natural rubber latex. * When ordering this component, the PT-03000-R and CL-08605-HF must also be ordered. ** When ordering this component, the PT-03000-R must also be ordered. *** When ordering this component, the PT-03009-RW and CL-08705-HF must also be ordered. **** Each product includes: two radiopaque polyurethane sheaths with integral side port/hemostasis valve, and one vessel dilator with SnapLock feature. LIBRARY OF CLINICAL SUPPORT Hein, A.N., Vesely, T.M. Use of the Percutaneous Thrombo lytic Device for the Treatment of Thrombosed Pseudoaneurysms During Mechanical Thrombectomy of Hemodialysis Grafts. Journal of Vascular Interventional Radiology. 2002; 13: 201 204. Lajvardi, A., Trerotola, S.O., Strandberg, J.D., Samphilipo, M.A., Magee, C. Evaluation of Venous Injury Caused by a Percutaneous Mechanical Thrombolytic Device. Cardiovascular Interventional Radiology. 1995; 18: 172 178. Lazzaro, C.R., Trerotola, S.O., Shah, H., Namyslowski, J., Moresco, K., Patel, N. Modified Use of the Arrow-Trerotola Percutaneous Thrombolytic Device for the Treatment of Thrombosed Hemodialysis Access Grafts. Journal of Vascular Interventional Radiology. 1999; 10: 1015 1031. McLennan, G., Trerotola, S.O., Davidson, D. et al. The Effects of a Mechanical Thrombolytic Device on Normal Canine Vein Valves. Journal of Vascular Interventional Radiology. 2001; 12:89 94. Patel AA. Tuite CM, Trerotola SO. Cardiovasc. Intervent Radiol. 2005 ;28(6); 704 13 Mechanical Thrombectomy of Hemodialysis Fistulae and Grafts Rocek, M., Peregrin, J.H., Lasovickova, J., Krajickova, D., Slaviokova, M. Mechanical Thrombolysis of Thrombosed Hemodialysis Native Fistulas With Use of the Arrow-Trerotola Percutaneous Thrombolytic Device: Our Preliminary Experience. Journal of Vascular Interventional Radiology. 2000; 11: 1153 1158. Shatsky et al. J.Vasc.Interv.Radiol. 2005 ; 1605 11 Single- Center Experience with the Arrow-Trerotola Percutaneous Thrombectomy Device in the Management of Thrombosed Native Dialysis Fistulas. Trerotola, S.O., Davidson, D.D., Filo, R.S., Dreesen, R.G., Forney, M. Preclinical In Vivo Testing of a Rotational Mechanical Thrombolytic Device. Journal of Vascular Interventional Radiology. 1996; 7: 717 723. Trerotola, S.O., Vesely, T.M., Lund, G.B., Soulen, M.C., Ehrman, K.O., Cardella, J.F. Treatment of Thrombosed Hemodialysis Access Grafts: Arrow-Trerotola Percutaneous Thrombolytic Device Versus Pulse-Spray Thrombolysis. Arrow-Trerotola Percutaneous Thrombolytic Device Clinical Trial. Radiology. 1998; 206: 403 414. Trerotola, S.O., McLennan, G., Davidson D., et al. Preclinical In Vivo Testing of the Arrow-Trerotola Percutaneous Thrombolytic Device for Venous Thrombosis. Journal of Vascular Interventional Radiology. 2001; 12: 95 103. Trerotola, S.O., McLennan, G., Eclavea, A.C. et al. Mechanical Thrombolysis of Venous Thrombosis in an Animal Model With Use of Temporary Caval Filtration. Journal of Vascular Interventional Radiology. 2001; 12: 1075 1085. Trerotola, S.O., Johnson, M.S., Schauwecker, D.S. et al. Pulmonary Emboli From Pulse-Spray and Mechanical Thrombolysis: Evaluation With an Animal Dialysis-Graft Model. Radiology. 1996; 200: 169 176. Vesely, T.M., Hovsepian, D.M., Darcy, M.D., Brown, D.B., Pilgram, T. K. Angioscopic Observations After Percutaneous Thrombectomy of Thrombosed Hemodialysis Grafts. Journal of Vascular Interventional Radiology. 2000; 11: 971 977. Vogel, P.M., Bansal, V., Marshall, M.W. Thrombosed Hemodialysis Grafts: Lyse and Wait With Tissue Plasminogen Activator or Urokinase Compared to Mechanical Thrombolysis With the Arrow-Trerotola Percutaneous Thrombolytic Device. Journal of Vascular Interventional Radiology. 2001; 12: 1157 1165.

ARROW-TREROTOLA PTD PERCUTANEOUS THROMBOLYTIC DEVICE THE MOST PROVEN MECHANICAL THROMBECTOMY TECHNOLOGY AVAILABLE FOR DIALYSIS ACCESS Innovative dialysis access products from Teleflex are designed to meet the needs of clinicians and inspired by theme. The Arrow-Trerotola PTD improves your ability to achieve fast and easy removal of thrombi from both dialysis native AV fistulae and synthetic grafts. SIMPLE The Arrow-Trerotola PTD is easy to assemble and operate, and as it comes with a mechanical thrombectomy catheter, a hand-held disposable rotator drive unit and an introducer sheath, there is no need to purchase additional equipment. catheter lumen sidearm: permits catheter flushing during preparation and use activated spinning basket macerates the thrombus introducer sheath and large-bore sidearm assembly simplifies thrombus removal short procedure time patient can immediately return to dialysis 2 PROVEN Satisfies key benchmarks to achieve better outcomes including K/DOQI guidelines for both immediate and threemonth patency and functionality rates. Arrow-Trerotola PTD is the only mechanical thrombectomy device indicated to pull the arterial plug 3. DIALYSIS ACCESS studies technical patency rate 3-month primary rate K/DOQI Guidelines 1 85 % 40 % PDT vs PSPMT 2 95 % 39 % Modified technique 3 100 % 42 % Use of PTD and native fistulae 4 100 % 70 % SAFE The Arrow-Trerotola PTD conforms to AV graft and AV fistulae walls, enabling you to remove clots with minimal risk of wall damage, and without the use of thrombolytics 5. AV SYNTHETIC GRAFT PTD device in use in a forearm-loop synthetic graft. REFERENCES 1 NNKF-K/DOQI Clinical Practice Guidelines for Vascular Access: Update 2000. American Journal of Kidney Disease. 2000; 37: 137 181. 2 Trerotola, S.O., Vesely, T.M., Lund, G.B., Soulen, M.C., Ehrman, K.O., Cardella, J.F. Treatment of Thrombosed Hemodialysis Access Grafts: Arrow-Trerotola Percutaneous Thrombolytic Device Versus Pulse-Spray Thrombolysis. Arrow-Trerotola Percutaneous Thrombolytic Device Clinical Trial. Radiology. 1998; 206: 403 414. 3 Lazzaro, C.R., Trerotola, S.O., Shah, H., Namyslowski, J., Moresco, K., Patel, N. Modified Use of the Arrow- Trerotola Percutaneous Thrombolytic Device for the Treatment of Thrombosed Hemodialysis Access Grafts. Journal of Vascular Interventional Radiology. 1999; 10: 1025 1031. 4 Rocek, M., et. al. Mechanical Thrombolysis of Thrombosed Hemodialysis Native Fistulas With Use of the Arrow-Trerotola Percutaneous Thrombolytic Device: Our Preliminary Experience. Journal of Vascular Interventional Radiology. 2000; 11: 1153 1158. 5 Lajvardi, A., Trerotola, S.O., Strandberg, J.D., Samphilipo, M.A., Magee, C. Evaluation of Venous Injury Caused by a Percutaneous Mechanical Thrombolytic Device. Cardiovascular Interventional Radiology. 1995; 18: 172 178. 6 Trerotola SO, Johnson MS, Shah H, Namyslowski J. Backbleeding technique for treatment of arterial emboli resulting from dialysis graft thrombolysis. JVIR. 1998;9:141 143.

ARROW-TREROTOLA PTD (5 FR.) ARROW-TREROTOLA PTD OVER-THE-WIRE (7 FR.) CATHETER LUMEN SIDEARM permits catheter flushing during preparation and use AV FISTULAE Pre-thrombectomy assessment of dialysis fistulae. Thrombectomy using the overthe-wire PTD via access sheath. Post-PTD thrombectomy fistulogram showing patent fistulae. Courtesy of Miloslav Rocek, MD, PhD, Institute for Clinical & Interventional Radiology (IKEM), Dept. of Diagnostic & Interventional Radiology Videnska 800, 14000 Prague 4 Czech Republic

FOR USE IN APPLICATIONS Dialysis AV fistulae and synthetic grafts SOFT, FLEXIBLE TIP designed to manoeuvre through vessel easily ACTIVATED SPINNING BASKET macerates the thrombus UNIQUE EXPANDABLE 9 MM FRAGMENTATION BASKET conforms to different diameter walls shown to easily remove residual thrombus from dialysis vessel walls 6

Teleflex is a leading global provider of specialty medical devices used for diagnostic and therapeutic procedures in critical care, urology and surgery. Our mission is to provide solutions that enable healthcare providers to improve outcomes and enhance patient and provider safety. We specialise in devices for general and regional anaesthesia, cardiac care, respiratory care, urology, vascular access and surgery and we serve healthcare providers in more than 140 countries. Teleflex also provides specialty products for medical device manufacturers. Our well known brands include arrow, deknatel, gibeck, hudson RCi, kmedic, lma, pilling, pleur-evac, RÜsCh, sheridan, taut, tfx oem, vasonova and weck, all of which are trademarks or registered trademarks of Teleflex Incorporated. Teleflex global operations: Australia, Austria, Belgium, Canada, China, Czech Republic, France, Germany, Greece, India, Ireland, Italy, Japan, Malaysia, Mexico, Netherlands, New Zealand, Portugal, Singapore, Slovak Republic, South Africa, Spain, Switzerland, United Kingdom, Uruguay and USA. YOUR INTERNATIONAL CONTACTS: TELEFLEX HEADQUARTER INTERNATIONAL, IRELAND Teleflex Medical Europe Ltd., IDA Business and Technology Park, Dublin Road, Athlone, Co Westmeath Phone +353 (0)9 06 46 08 00 Fax +353 (0)14 37 07 73 orders.intl@teleflex.com AUSTRALIA/NEW ZEALAND +61 (0)3 9081 0600 AUSTRIA +43 (0)1 402 47 72 BELGIUM +32 (0)2 333 24 60 CHINA (SHANGHAI) +86 (0)21 6381 6399 CHINA (BEIJING) +86 (0)10 6418 5699 CZECH REPUBLIC +420 (0)495 759 111 FRANCE +33 (0)5 62 18 79 40 GERMANY +49 (0)7151 406 0 GREECE +30 210 67 77 717 INDIA +91 (0)44-2836 5040 ITALY +39 0362 58 911 JAPAN +81 (0)3 3379 1511 NETHERLANDS +31 (0)88 00 215 00 PORTUGAL +351 22 541 90 85 SINGAPORE +65 6447 5022 SLOVAK REPUBLIC +421 (0)3377 254 28 SOUTH AFRICA +27 (0)11 807 4887 SPAIN +34 918 300 451 SWITZERLAND +41 (0)31 818 40 90 UNITED KINGDOM +44 (0)1494 53 27 61 For detailed information see www.teleflex.com The products in this catalogue may not be available in all countries. Please contact your local representative. All data current at time of printing (11/2013). Subject to technical changes without further notice. 94 11 11-00 00 01 REV A MC / WM 11 13 01