e 1 0 0 I N S T RUC TION M ANU A L



Similar documents
Ultrasonic Distance Meter. Operation Manual

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

Leica DISTO TM D210 The original laser distance meter

digital fever alert ear thermometer suitable from birth instruction manual

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos , and

User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Table of Contents. Dewalt DW Delete Memory

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Table of Contents. Stanley TLM330 1

High Temperature InfraRed Thermometer with Laser Pointer

Leica DISTO TM X310 The original laser distance meter

TABLE OF CONTENTS 11.0 WARRANTY

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Portable Multiband Radio ( A) Features Faxback Doc. # 56400

Point of view HDMI Smart TV dongle Mini RF Keyboard

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Pocket Tach 99 (PT99) Non-Contact Tachometer

Wireless Indoor/ Outdoor Thermometer

Digital Fingerprint safe

LASER DIAGRAM TABLE OF CONTENTS. SKY Technologies Inc. Laser Diagram. Technical Specifications. Laser Operation.

NFC Communication Tray Model: HHX-IT3-Z

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Hygro-Thermometer + InfraRed Thermometer Model RH101

Laser Calibration Check

TECHANGLE November 30, 2005 TECHNICAL PAGE

Important Safety Instructions

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

AM/FM PLL Clock/Table Radio

Operating Manual Color Changing Fountains

Manual Ranging MultiMeter

AM/FM Portable Radio

Mini Power Bank and Charger

by QUICK START GUIDE 1

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

LED Security Spotlight User Manual

12 Volt 30 Amp Digital Solar Charge Controller

ER102. Emergency Crank Weather Radio Owner s Manual.

Dual Laser InfraRed (IR) Thermometer with Color Alert

MAINTENANCE & TROUBLESHOOTING

AutoRanging Digital MultiMeter

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

24 Wide Screen LED Monitor with HDMI

METAL DETECTOR OWNER S MANUAL

WSD130 SOLDERING STATION

62 Max/62 Max + Infrared Thermometer

IN-OUT Thermometer with Cable Free Sensor and Clock

How To Use The Visifault Visual Fault Locator

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

ExStik TM ph Waterproof Meters

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

Tympanic Thermometer

User Guide. Temperature and Humidity Datalogger. Model 42280

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Wireless Optical Mouse

Model 349KLX Remote Display Digital Scale User Instructions

Dual Laser InfraRed (IR) Thermometer

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Digital Photo Picture Frame. Operation Manual

Phoenix Body Fat Scale Manual

Features: Mounting the Optic

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

User's Guide Integrating Sound Level Datalogger Model

LG Wireless Remote Controller

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Guide. Model Insulation Tester / Megohmmeter

Instruction manual for Firstline FCS12000CH

Owner s Manual & Safety Instructions

PowerLine Magnetic-Laser Sheave Alignment System Instructions

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Elite Edition Metal Detector

Ireland Australia New Zealand

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Touchless Forehead Thermometer

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

PR-2500 Portable Receiver. Owner s Manual

Jarv Nmotion BTHL-201 Bluetooth Stereo Earbuds Users Guide

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Atomic Projection Alarm Clock model 13021

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

BT Big Button 100. User Guide

REMOTE TERMOMETER TE 219 LED USER MANUAL

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

DAB+ / FM Tuner Model: TU-201

Gold Century GC-1023 Metal Detector

Mini InfraRed Thermometer with Laser Pointer

Seven function digital multimeter

Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3

MEASURING AND LEVELING TOOLS

USER GUIDE. USB 2.0 DVD/CD-ROM Slim External Drive

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

BTH360-S Bluetooth Stereo Headset Specifications & User's Guide

Forehead. Use and Care Manual. Thermometer IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Model V977

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

Transcription:

e 1 0 0 I N S T RUC TION M ANU A L

The Empire Digital Level Accuracy, Readability, Durability one FEATURES: Easy to read back light Display reads right side up even if the level is upside down Audio beep is made at 0 and 90 when within 1º Automatic shut-off Laser can be used when digital level is off Zero button to easily calibrate measurements Units button shows degrees, pitch/slope percentage and in/ft Push-button memory to hold measured angle Horizontal and vertical TrueBlue Level Vials can be used for back-up and calibration Heavy duty 6061 aluminum frame with milled edges offer strength and accuracy Ergonomic rubber hand grips for comfort Dual molded rubber end caps for shock resistance FOR YOUR SAFETY: Important: Read and understand all instructions before using this tool. Failure to follow all of the following instructions may result in fire, electrical shock or other serious injuries. Read and carefully follow directions and warning on battery package. Be sure to insert batteries correctly. Polarity (+ and ) is clearly marked on tool. Do not short battery terminals or charge the batteries. Do not mix old and new batteries. Always replace weak batteries with two (2) AA of the same brand. Immediately remove dead batteries and dispose of them in accordance with your local ordinances. Do not dispose of batteries in fire. Keep batteries out of reach of children. Remove batteries if tool will not be used for several days or longer. 1

The Empire Digital Level Accuracy, Readability, Durability two Laser light emitted from this aperture - Do not stare into light beam. Do not remove or deface any product labels. Always keep it out of the reach of children. Do not attempt to repair or disassemble the Digital laser level. Do not operate the tool in combustible areas. Do not attempt to modify the performance of the laser device in any way. Use of controls, adjustments or the performance of procedures other than those specified in this manual may result in hazardous radiation exposure. The use of optical instruments such as, but not limited to, telescopes or transits to view the laser beam will increase eye hazard. PROBLEM SOLVING: If display screen does not light when level is turned on, be sure that batteries are correctly inserted and check battery charge as replacement may be needed. If you experience other problems, contact the Empire Service Department at 1.800.558.0722. CARE AND MAINTENANCE: Handle your Empire Digital Level with care at all times. Appropriate use and maintenance will help to keep it accurate and in good working order. Wipe clean with a damp cloth (water only) as needed. Do not immerse in water. Do not store level at extreme temperatures above 140 or below 20 F (-6º C to 60º C). ATTENTION: For optimal performance after unpackaging, calibration of the digital unit should be performed prior to utilizing the level - Refer to page 4 for proper calibration procedure. 2

The Empire Digital Level Accuracy, Readability, Durability three HOW TO: Be sure to read all instructions carefully before using your Empire Digital Level. This level can be used both indoors and out for horizontal, vertical and angled alignment. Two (2) AA alkaline batteries (not included) are needed for operation. Button Functions:On/Off Press and hold button to turn level on. Push again to turn back light off. Press and hold the button to turn level off. Level will automatically turn off when position changes less than 1 in 5 minutes to save battery life. Audio Push audio button to hear beep within 1 degree of level or plumb. Audio tone will sleep after 30 pulses. Press any button (except Laser) to restart audio. 3

The Empire Digital Level Accuracy, Readability, Durability four Laser Simply press and hold the button to turn laser on, and press the button to turn off. The laser can be used even if the display is not on. Note: The laser will not automatically turn off after 5 minutes.red light located below digital module indicates when laser is on. Zero Calibration function: Press and hold until flashing For simple calibration of your e100 digital level, follow the three easy steps illustrated below: 1. Place level on a flat surface with the digital display facing you. Push and hold the ZERO button until CAL1 begins to flash on the display. Release the ZERO button and wait for CAL2 to appear on the display. 2. Rotate the level end to end 3. With digital display facing away from you, press the ZERO button. CAL2 will begin to flash on the display. Once CAL2 stops flashing on the display, the display will return to the home screen. Your e100 digital level is now calibrated and ready to use. Always perform this calibration procedure if your level is ever dropped or to verify that the unit is properly calibrated. Zero at Present Position function: Press and release By pressing the zero button and immediately releasing it the tool can be set at zero at that new position, allowing the user to move the tool and start the measurement from that new starting point as zero. 4

The Empire Digital Level Accuracy, Readability, Durability five Units Press to change display units: degrees ( ), slope (%), pitch (IN/FT) (shown plus(+) or minus(-) depending on direction of pitch). Press and hold button to continuously switch display between, %, IN/FT. Memory Push button to hold or release the current display, arrows will blink when display is fixed. DIGITAL DISPLAY READING: Up/Down arrows get shorter as it gets closer to level or plumb. Speaker icon shows in display window when Audio beep is activated., %, IN/FT displays to show measurement mode. Reads right side up no matter how the level is positioned. 5

The Empire Digital Level Accuracy, Readability, Durability six DIGITAL SENSOR ACCURACY: Horizontal & Vertical Position Between +1 degree and -1 degree/ 89 degrees to 90 degrees digital sensor to be accurateto + or -.05 degrees All Other Positions Digital sensor to be accurate to + or -.1 degree Digital Sensor Temperature Range Above mentioned accuracy is measured between 0 and 50 degrees C (32 and 122 degrees F) Laser Module Class II diode with a CAUTION label less than 1mW, 635-665nmLaser dot no larger than 11/32 (8.6mm) at 50 (15.24 meters) Complies with 21CFR parts 1040.10 and 1040.11 MODULE SOUNDS: Beep intervals indicates level position with shorter time between beeps as the level approaches true level or plumb. Then a rapid 6 tones when in the 0 degree level position. Beeping begins within 1 degree of level or plumb. WARRANTY: EMPIRE DIGITAL LASER LEVEL LIMITED ONE YEAR WARRANTY This Empire Digital Laser Level is warranted to be free from imperfections in materials and workmanship. It is an electronic tool with sensitive digital and laser components thus susceptible to damage from shock. Protect this level in the case provided and do not drop the tool. Damage caused by shock is not covered by the warranty. If the level fails under normal use, contact Empire directly for repair or replacement within 1 year of your original date of purchase. Bent frames or broken/cracked components are the result of undue shock and void the warranty. 6

929 Empire Drive PO Box 800 Mukwonago, WI 53149 Toll Free: 800-558-0722 www.empirelevel.com PR400-08/13