Geofoam A Light Weight Fill Alternative



Similar documents
Value of Instrumentation Systems and Real-Time Monitoring: An Owner s Perspective

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

Specification Guidelines: Allan Block Modular Retaining Wall Systems

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

The Original Carbon Fiber Reinforced Polymer System

REPAIR AND RETROFIT OF BRIDGES DAMAGED BY THE 2010 CHILE MAULE EARTHQUAKE

New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations

Bartlett, Negussey, Kimble and Sheeley. Use of Geofoam as Super-Lightweight Fill for I-15 Reconstruction

Safe & Sound Bridge Terminology

SECTION 1 GENERAL REQUIREMENTS

COMMERCIAL BUILDING APPLICATIONS

ROAD CONSTRUCTION. Pavement Base Reinforcement Subgrade Stabilization

SECTION SHEETING, SHORING AND BRACING

REINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:

Managing North Carolina's MSE Wall Assets through Design, Construction and Performance

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Table of Contents. July

ANNEX D1 BASIC CONSIDERATIONS FOR REVIEWING STUDIES IN THE DETAILED RISK ASSESSMENT FOR SAFETY

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Design of Bridges. Introduction. 3 rd to 4 th July Lecture for SPIN Training at the University of Dar es Salaam

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

EXPANDED POLYSTYRENE FOR. ResidentialBuilding Applications

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Drainage Composites. The ready-made solution to sub soil drainage

symptoms of a faulty foundation

Construction Specifications for Keyhole Pavement Coring and Reinstatement

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

PVC PIPE PERFORMANCE FACTORS

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Culvert Rehabilitation A presentation by ms consultants, inc. engineers, architects, planners

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

Green Thread Product Data

Marketing Coordinator Bootcamp Session 2: ABCs of AEC

EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL

BRIDGES ARE relatively expensive but often are

beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...

Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains

Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions

List of Graduate Level Courses in Civil Engineering

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

Soft, diagnostic and proof load testing in routine bridge assessment. Joan R. Casas Technical University of Catalunya (UPC) Barcelona, Spain

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Thermal Stress & Strain. 07 Thermal Stress and Strain Copyright G G Schierle, press Esc to end, for next, for previous slide 3

Chapter 3 Pre-Installation, Foundations and Piers

High Capacity Helical Piles Limited Access Projects

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

CE591 Lecture 8: Shear Walls

Emergency repair of Bridge B421

BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM

SECTION STORM DRAIN SYSTEM

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND TELECOMMUNICATION CABLES IN THE VICINITY OF TRANSPORTATION FACILITIES

7. Do you perform any out of state work?... If yes, in what states and provide details of work performed

CHAPTER 8 CIVIL DESIGN

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Designed and Engineered to Perform

Long-term serviceability of the structure Minimal maintenance requirements Economical construction Improved aesthetics and safety considerations

ARCHITECTURE. Asst. Prof. Meltem VATAN KAPTAN

Precast Modular Block (PMB) for Retaining Wall Systems

Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC October 27, 2015 Session 26

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Structural Performance of Highway Bridges under Given Foundation Settlements

The Verdura Wall check with your local building department

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

The AASHO Road Test site (which eventually became part of I-80) at Ottawa, Illinois, was typical of northern climates (see Table 1).

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

WATERVIEW CONNECTION PROJECT. Ground Settlement WATERVIEW CONNECTION TEAM

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

The unit costs are based on the trend line of the 3 low bids for the average quantity.

Current Status of Seismic Retrofitting Technology

Hunter College school of Social Work Thesis Proposal

Wisconsin Building Products Evaluation

Söderströmtunnel: immersion in downtown Stockholm, Sweden

SECTION EARTH MOVING

Cellar Tech Containment Well Cellar Systems

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

Vacuum Consolidation Dewatering in Sediment Remediation

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Technical Manual - Section 1 Introduction to Lytag lightweight aggregate

1. ASTM C Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

EGYPTIAN CODES FOR DESIGN AND CONSTRUCTION OF BUILDINGS

COSMOS 2012: Earthquakes in Action COSMOS 2012

Transcription:

Geofoam A Light Weight Fill Alternative

Insulfoam A wholly owned subsidiary of Carlisle Construction Materials Headquarters in Puyallup, WA Producer of expanded polystyrene (EPS) for more than 45 years The largest manufacturer of blockmolded expanded polystyrene in North America Insulfoam is the only manufacturer of Expanded Polystyrene (EPS) with the ability to service national customers

Family of Products

Agenda Geofoam applications/projects USACE Pump Station Costco Wheatley Elementary Recent Trends Standards Specifications Placement/handling/installation

ELIMINATE OR REDUCE LATERAL LOADING ON RETAINING STRUCTURES ZERO NET LOADING FOR SOFT SOIL REMEDIATION ENGINEERED FOR SLOPE STABILIZATION PROTECT AND LIGHTEN THE LOAD ON BURIED UTILITIES KEEP IT SIMPLE AND FAST WITH STRUCTURAL VOID FILL CONCRETE APPLICATIONS Lighten the Load 5 MAJOR APPLICATIONS TO CONSIDER GEOFOAM

Eliminate or Reduce Lateral Loads for InsulFoam GF replaces the sliding soil wedge Native soils are self supporting when excavated back to the angle of repose InsulFoam GF is self supporting End result: ZERO lateral load on the retaining structure RETAINING STRUCTURES

I80 & 148th Street Waverly, NE

Hwy 50 Culvert Overpass Carson City, NV

InsulFoam GF Benefits Significantly reduces structural steel, concrete and forming costs/time Decreases or Eliminates the need for geo-grids or mechanical tie-backs Allows walls to be designed taller and in more narrow rights-of-way Eliminates the need for secondary compaction which speeds construction for Retaining Structures

I-680 Interchange Martinez, CA Soft soils only settle when more weight is added on top Calculate the weight of the Geofoam and all other loads Excavate an equivalent weight of native soil End Result: Net ZERO loading Net Zero Load Designs for SOFT SOIL REMEDIATION

Wheatley Elementary School New Orleans, LA

Costco New Orleans, LA

Louis Armstrong Int l Airport New Orleans, LA

InsulFoam GF Benefits for Soft Soil Remediation Increases - Speed of installation Productivity Decreases - Rights-of-way concerns Traffic closures Heavy equipment costs Soil removal costs Borrow-fill placement Eliminates - Surcharging time/cost Soil Settlement Secondary compaction Port of Longview, WA

Heavy Soils + Gravity + H 2 O = High Landslide Potential Geofoam is up to 100 times lighter than soil Using Geofoam reduces the weight and the risk Lighten the driving block for SLOPE STABILIZATION

US 101 - Willits, CA

USACE Lake Cataouatche Pump Station Avondale, LA

USACE Lake Cataouatche Pump Station Avondale, LA

InsulFoam GF Benefits for Slope Stabilization Increases - Speed of installation Productivity Space for additional traffic lanes Decreases - Traffic closures Heavy equipment costs Borrow-fill placement Concerns about future landslide/erosion issues Environmental impact on sensitive hillside jobsites Long-term maintenance and slope failure costs Hillside Restoration in Japan

Reduces dead and lateral loads on underground pipes, culverts and tunnels Protects utility during seismic activity by reducing axial strain Provides high thermal insulation values that protect against severe temperature fluctuations Protect and lighten the load on top of BURIED UTILITY PROTECTION

Royal Brougham Way - Seattle, WA

Maggie Daley Park Chicago, IL

Maggie Daley Park Chicago, IL

Maggie Daley Park Chicago, IL

InsulFoam GF Benefits for Buried Utility Protection Allows construction directly on top of buried utilities Eliminates right-of-way or eminent domain claims to move the utility Allows designers to specify less expensive structural utilities such as box culverts and pipes Reduced dead loads prolongs the life of structure

Eliminates separate concrete pours for vertical wall sections Reduces overall amount of concrete or other heavy fills Reduces dead loads on underlying structures Keep it Simple and Fast with Any shape or slope can be easily fabricated on site STRUCTURAL VOID FILL CONCRETE APPLICATIONS

Pacific Street Bridge Omaha, NE

Box Beam Bridge Girders

Bridge Column Voids

Bridge Column Custom Forms

InsulFoam GF Benefits as a Structural Lightweight Void Fill Eliminates the need to pour the walls separately from the topping slab Decreases labor costs versus heavy soil backfill Decreases forming time and material costs Community College, Scottsdale, AZ Easily supports the weight of concrete slabs

UTA TRAX, Salt lake City, UT Recent Trends

Load Distribution Slab within Assemblage

Shotcrete over Geofoam Topaz Bridge, McCammon, ID

Grimsøyveien, Norway Bridge Abutments

T-Wall with Geofoam Tappan Zee Approach, Tarrytown, NY

ASTM D6817 Understanding ASTM D6817 (different than ASTM C578)

ASTM D6817 vs. C578 Geotechnical Density lb/ft³, min. Insulation Compressive Resistance, min. psi @ 10% deformation Flexural Strength, Min., psi ASTM D6817 EPS 15.90 10.2 25 ASTM C578 Type I.90 10.0 25 ASTM D6817 EPS 19 1.15 16.0 30 ASTM C578 Type VIII 1.15 13.0 30 ASTM D6817 EPS 22 1.35 19.6 40 ASTM C578 Type II 1.35 15.0 35 ASTM D6817 EPS 29 1.80 29.0 50 ASTM C578 Type IX 1.80 25.0 50

Reduce Your Carbon Footprint 1 truckload of Geofoam = 12 dump trucks of fill

Handling

Handling

Hot Wire Cutters

Geofoam works best when used to reduce naturally occurring forces such as from gravity rather than to strengthen or stiffen a structure to resist these forces Philosophy of load reduction as opposed to strength increase Success of geofoam is due to working with the forces of nature rather than resisting natural forces as construction materials are traditionally designed to do

5 MAJOR APPLICATIONS TO CONSIDER GEOFOAM ELIMINATE OR REDUCE LATERAL LOADING ON RETAINING STRUCTURES ZERO NET LOADING FOR SOFT SOIL REMEDIATION ENGINEERED FOR SLOPE STABILIZATION PROTECT AND LIGHTEN THE LOAD ON BURIED UTILITIES KEEP IT SIMPLE AND FAST WITH STRUCTURAL VOID FILL CONCRETE APPLICATIONS