PREPIPED LIQUID FUEL MANIFOLDS PLPM



Similar documents
Your safety and the safety of others are very important.

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

GAS SAFETY PRECAUTIONS

Your safety and the safety of others are very important.

LPM-06 CONVERSION KIT

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

NFPA31FuelOilPiping 1 Revised

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

G670 Intermittent Pilot Ignition Controls

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Operator: Save these instructions for future use!

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Float and Thermostatic Traps Series H, C and X

ECO-STAR II. ECO-nomical ECO-logical the ECO-STAR II. Packaged Low NOx Multi-Fuel Burner. Features. Benefits. Combustion Excellence Since 1888 ESII-1

NAVIEN AMERICA INC FITCH AVENUE

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

CARING FOR YOUR WATER HEATER

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

1805 Series Relief Valves

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

!"" #$% "!&' ( ( ) *

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

NITROUS TRANSFER PUMP INSTRUCTIONS

Air Eliminators and Combination Air Eliminators Strainers

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

SIOUX HYBRID WATER HEATER

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

SELECTION, APPLICATION AND MAINTENANCE

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

San josé OWNER S MANUAL

Technical Data. Installation

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Model 1210C Battery Powered Pump Shown. Description

Oil and Coolant Circulating Heating System. Model - OCSM

Installation Manual DIAPHRAGM WELL TANK

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

TYPE E Main Valve Sizes 3 /8 through 12

OTF Oil Fired Pool Heater

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

300 Series PA Pump and Cooler Assemblies

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

INSTALLATION INSTRUCTIONS

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

167D Series Switching Valves

M A N U A L

Installation Manual DIAPHRAGM WELL TANK

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Commercial & Industrial Propane Regulators and Meters

OPERATING, INSTALLATION AND SERVICE MANUAL

1301 Series High-Pressure Regulators

DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION

BERMAD Fire Protection

Tankless Water Heater

orlando OWNER S MANUAL

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Boiler Preparation, Start-Up and Shutdown

High Efficiency Commercial Gas Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

Installation Instructions for Alarm Module Kit A043F059

Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations

Element D Services Plumbing

Ceiling Mount Air Handler Manual

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

SIZING AND CAPACITIES OF GAS PIPING

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

ASX7-4-IOM-7 J

SL280UHV SERIES GAS FURNACE WARNING

I-768 FireLock NXT Dry Valve

ADMINISTRATIVE SERVICES MANUAL

Service Manual. Condensing Boiler. Getting Service

SIZING AND CAPACITIES OF GAS PIPING

GAS, OIL & DUAL FUEL WATER HEATERS

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

2010 Residential Water Heater Replacement Check List

Transcription:

PREPIPED LIQUID FUEL MANIFOLDS PLPM INSTRUCTIONS WARNING These instructions are intended for use only by experienced, qualified combustion start-up personnel. Adjustment of this equipment and its components, by unqualified personnel, can result in fire, explosion, severe personal injury, or even death. TABLE OF CONTENTS Subject Page A. General Information.. 2 B. Receiving and Inspection. 2 C. Capacities... 2 D. Dimensions. 4 E. Liquid Propane Installation PLPM.. 6 F. Initial Setup. 8 G. Operation 9 H. Maintenance... 9 I. Recommended Spare Parts 9 These instructions are intended to serve as guidelines covering the installation, operation, and maintenance of Hauck equipment. While every attempt has been made to ensure completeness, unforeseen or unspecified applications, details, and variations may preclude covering every possible contingency. WARNING: TO PREVENT THE POSSIBILITY OF SERIOUS BODILY INJURY, DO NOT USE OR OPERATE ANY EQUIPMENT OR COMPONENT WITH ANY PARTS REMOVED OR ANY PARTS NOT APPROVED BY THE MANUFACTURER. Should further information be required or desired or should particular problems arise which are not covered sufficiently for the purchaser's purpose, contact Hauck Mfg. Co. HAUCK MANUFACTURING CO., 100 North Harris Street Cleona, PA 17042 717-272-3051 10/13 www.hauckburner.com Fax: 717-273-9882

Page 2 WARNING This equipment is potentially dangerous with the possibility of serious personal injury and property damage. Hauck Manufacturing Company recommends the use of flame supervisory equipment and fuel safety shutoff valves. Furthermore, Hauck urges rigid adherence to National Fire Protection Association (NFPA) standards and insurance underwriter s requirements. Operation and regular preventative maintenance of this equipment should be performed only by properly trained and qualified personnel. Annual review and upgrading of safety equipment is recommended. A. GENERAL INFORMATION The Hauck PLPM series liquid propane manifold is designed to meet industry-accepted standards for fuel delivery to LP fired combustion systems. B. RECEIVING AND INSPECTION Upon receipt, check each item on the bill of lading and/or invoice to determine that all equipment has been received. A careful examination of all parts should be made to ascertain if there has been any damage in shipment. IMPORTANT If the installation is delayed and the equipment is stored outside, provide adequate protection as dictated by climate and period of exposure. Special care should be given to all motors, bearings and control panels, if applicable, to protect them from rain or excessive moisture. C. CAPACITIES MODEL CONNECTION MAXIMUM FLOW FLOW FACTOR NUMBER SIZE (NPT) (gpm) (gph) C v PLPM 207-1 3/4 NPT 6.6 396 5.5 PLPM 207-2 3/4 NPT 19.3 1,160 11.7 PLPM 212-1 1-1/4 NPT 25.7 1,540 12.3 PLPM 212-2 1-1/4 NPT 38.5 2,310 14.5 Notes: 1. PLPM maximum flow based on liquid propane with 0.50 specific gravity at 60 F. 2. To calculate maximum Btu/hr throughput, multiply liquid propane flow in gal/hr by higher heating value (HHV) of 90,912 Btu/gallon. 3. Liquid Petroleum Gas-based fuels other than liquid propane will have different specific gravities, and consequently, different maximum flow rates. Additionally, heating values for other LPG-based fuels may vary significantly. Consult your fuel supplier for fuel heating value and specific gravity. Table 1. PLPM Capacities

Page 3 C. CAPACITIES (Continued) MODEL CONNECTION MAXIMUM FLOW FLOW FACTOR NUMBER SIZE (NPT) (lpm) (lph) C v PLPM 207-1 3/4 NPT 25.0 1,500 5.5 PLPM 207-2 3/4 NPT 73.1 4,380 11.7 PLPM 212-1 1-1/4 NPT 97.3 5,840 12.3 PLPM 212-2 1-1/4 NPT 146 8,740 14.5 Notes: 1. PLPM maximum flow based on liquid propane with 0.50 specific gravity at 15.5 C. 2. To calculate maximum Btu/hr throughput, multiply liquid propane flow in lit/min by lower heating value (LHV) of 23.5 MJ/liter. 3. Liquid Petroleum Gas-based fuels other than liquid propane will have different specific gravities, and consequently, different maximum flow rates. Additionally, heating values for other LPG-based fuels may vary significantly. Consult your fuel supplier for fuel heating value and specific gravity. Table 2. PLPM Metric Capacities

D. DIMENSIONS Page 4 Note: All dimensions are in inches. Y6053 (NOT TO SCALE) Figure 1. Dimensions

D. DIMENSIONS (Continued) Page 5 Note: All dimensions are in mm. Y6053 METRIC (NOT TO SCALE) Figure 2. Metric Dimensions

Page 6 WARNING Adjustment of this equipment, and its components, by unqualified personnel, can result in fire, explosion, severe personal injury, or even death. Liquid propane is highly flammable and heavier than air. It will accumulate near the ground in the area of a leak and it dissipates relatively slowly. Under no circumstances should personnel smoke, weld or perform any work with an open flame around the propane installation area. E. LIQUID PROPANE INSTALLATION PLPM CAUTION Hauck recommends following NFPA 58 for equipment, installation, and operational guidelines. Failure to use the appropriate equipment or installation practices could create hazardous conditions. NOTE The presence of small amounts of water in liquid propane can result in the formation of internal ice which can result in control valve and nozzle freezing. If freezing continues to be a problem, consult your propane supplier about the addition of alcohol (usually methanol) to your propane supply. The additive combines with the water making it a burnable mixture. MECHANICAL 1. The PLPM is designed to handle liquid propane. Prepare an area within 15 ft (4.6m) of the burner oil inlet to accept the manifold. Attempt to position the manifold as close to the burner as possible. The area should be level and flat. The manifold can be mounted on metal or concrete. Using at least four of the mounting holes in the base, mount the manifold to the mounting structure with appropriate bolts and fasteners. Avoid welding the manifold to its final location unless impractical. The location of the manifold should not be above the horizontal centerline of the burner. In making the connections to the manifold inlet, avoid excessive pressure drops. For example, minimize the number of fittings, elbows and valves. Excessive pressure drops will cause the piping to "freeze up" and result in poor burner performance.

Page 7 Y4059 (NOT TO SCALE) Figure 3. Typical Piping Schematic of PLPM with StarJet Burner 2. The position indication windows on the automatic safety shutoff valves must be visible to equipment operators. The valve heads can be field rotated to accommodate viewing the position indication window. Do not attempt to rotate the valve head consult Hauck or valve manufacturer for instructions. 3. Once the manifold is in place, connect the LP supply piping to the PLPM inlet. It is recommended that a ball valve followed by a tee fitting with a plug in the branch connection and a union in the through connection is installed upstream of the manifold inlet. This will ease manifold maintenance and serve as a leak test pressurization point (see Figure 4). X7642 (NOT TO SCLAE) Figure 4. Typical Schematic of PLPM Leak Test Piping

Page 8 4. Make the piping connection to the manifold outlet. Use an appropriate pipe sealant on all field-piping connections suitable for LP service (Hauck recommends Loctite 565 or equal). Once the piping connections are made, the electrical connections can be started. ELECTRICAL Each PLPM is equipped with three components that require electrical connections (see Table 3). Consult component wiring diagrams (on component cover plates) for component terminal numbers. Component Low/High LP Pressure Switch Main LP Shutoff Valve, Blocking LP Shutoff Valve Connection Type Wired Normally Open. Control Voltage, Neutral, Valve Closed Switch(VCS) And In Some Cases The Valve Open Switch (VOS) Must Be Wired In Accordance With Applicable Control System Schematics; Consult Drawings And Manuals Supplied With Your Control System. Table 3. PLPM Electrical Component Wiring F. INITIAL SET-UP IMPORTANT Before subjecting the manifold to fuel, cycle the automatic shutoff valves 10 times to prepare the valve seat and gate for operation. Once all piping and electrical connections are complete, the system should be leak tested. 1. Close the ball valve at the inlet of the manifold and at the burner fuel inlet. Also close the leak test ball valve. 2. Start the LP pump and leak check all components upstream of the PLPM. 3. If any leaks exist, repair as necessary. 4. Remove the pipe plug from the PLPM leak test connection. 5. Pressurize the PLPM manifold using 250 psig (1725 kpa). 6. Coat all piping connections with a leak test solution of liquid soap and water. If any bubbles appear, a leak exists. Repair the leak before proceeding. CAUTION If any leaks exist downstream of the safety shutoff valves when they are in the "shut" position, contact Hauck or the valve manufacturer immediately.

Page 9 7. Once all leaks on the inlet side of the manifold are repaired, energize the main safety shutoff valve and coat all piping connections downstream of the main safety shutoff valve with the leak test solution. 8. Repair any leaks as necessary. 9. Lastly, energize both safety shutoff valves and coat all piping downstream of the valves with the leak test solution. 10. Repair any leaks as necessary. 11. Depressurize manifold. Switch Adjustment Adjust the low/high LP pressure switch to the desired setting each switch is factory set at 165 and 230 psig (1140 and 1590 kpa), respectively. G. OPERATION Once properly installed and initially set, the prepiped manifold is ready for operation. The combustion control system will automatically cycle and operate the safety shutoff valves and monitor the safety switches. If pressure in any section of the manifold exceeds 450 psig (3100 kpa), one of the overpressure relief valves will relieve gas to the atmosphere. Should this occur, the combustion system must be shut down immediately. Do not remove or plug emergency relief valves. H. MAINTENANCE The manifold does not require any normal maintenance. I. RECOMMENDED SPARE PARTS Item Manifold Type Part No. Description 1 PLPM 301174 Switch, Low/High Pressure 2 PLPM 46956 Relief Valve, Overpressure 3 PLPM 37353 Gauge, Liquid Filled, 0-400 psig Table 4. Manifold Spare Parts List