MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com



Similar documents
Wiring Diagram. Diplomat 400V 3N.

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Technical data. Danfoss DHP-A

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Condensing unit type EPSILON-ECHOS LE Technical information manual

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Failure code manual. content

User manual. 086U6297 Rev. 9 EN

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

, User s Manual

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

User manual. Solid (FR 98,),

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Looking for support? Heat Pump Troubleshooting Guide

User manual. 086U6297 Rev. 6 EN

Installation Guide. Atec.

MP-4000 Alarm List (Software version or later)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Commissioning. Atec.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS

User manual. Atec. 086L0130 Rev. 1 EN

14. Troubleshooting Guide

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SMM. Installation Operation Maintenance

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Aerona Air Source Heat Pumps

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

OWNER S Manual PRINTED IN CANADA 10/2009

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Low Profile Unit Cooler

DIABLO VALLEY COLLEGE CATALOG

ECOCIAT. Domestic hot water heat recovery unit

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

SERVICE MANUAL REFRIGERATION

PANASONIC TROUBLE SHOOTING GUIDE

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Service Instructions. Atec.

Automatic Bypass Control AVDO

MicroTech III Unit Controller for Water Source Heat Pump Units

MicroTech III Unit Controller for Water Source Heat Pump Units

Fully Pumped Systems

Description of functions

REFRIGERATION AND AIR CONDITIONING MECHANIC TRADE REGULATION

SERVICE MANUAL REFRIGERATION

Instruction manual for Firstline FCS12000CH

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

QPCD QPCD-100 Parts List 115 Volt / 1 Phase / 60 Hz / R-134A REFRIGERANT COMPRESSOR, 0.75HP, R-134A DRAIN VALVE, 2-WAY SOLENOID VALVE, 0.

Installation Guide. DEVIreg 530. Electronic Thermostat.

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

How Ground/Water Source Heat Pumps Work

*.ppt 11/2/ :48 PM 1

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Cool Design for Homes and Offices

Hoshizaki America, Inc.

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Housing

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Heat Pumps for Swimming Pools

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

A/C refrigerant system, overview

COMMISSIONING OF HVAC SYSTEMS

10.1 Indoor Unit Error Display

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Laddomat Charging unit

HEAT SIPHON ANSWERBOOK

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Contents. Introduction

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Installation and maintenance instructions. Danfoss Vent

ZUBA-CENTRALTM. Heating & Cooling. Evolved. HEATING AND AIR CONDITIONING FOR WHOLE-HOME, YEAR-ROUND COMFORT

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

marine/bespoke split applications

SWIMMING POOL HEAT PUMP Owners Manual

Labotek Reservedelside

Air Source Heat Pump Installation and Maintenance Manual

DEVIreg 330 (+5 to +45 C)

Air conditioning, electrical testing

Oil and Coolant Circulating Heating System. Model - OCSM

LK Electric Boiler - 4,5

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

30RB/30RQ. Operation and maintenance instructions

SWIMMING POOL HEAT PUMP

Cooling system components, removing and installing

Overheating limit control

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W70A1 W70L1. Models: Contents. General Notes. Important. Description

T-100-R Installation Guide

Tim Sisson - Trane HVAC OVERVIEW

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

How To Use A Water Source Heat Pump

NIBE FIGHTER 2020

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Transcription:

MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com

Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC) Copyright Danfoss A/S

Table of Contents 1 Legend... 4 1.1 Legend... 4 2 20-26kW 400V 3N... 6 2.1 20-26kW 400V 3N... 6 3 35-42kW 400V 3N... 14 3.1 35-42kW 400V 3N... 14 Danfoss Heating Solutions VWIFB102 3

1 Legend 1.1 Legend Number/Note Description 1 Heat pump 3 Outdoor unit 36 Circulation pump (system) 40 Expansion card 50 Outdoor sensor 51 System supply line sensor 52 Sensor for EM-Modul module/ret.line sensor 53 Hot water starting sensor 55 Hot water sensor top 62 Room Sensor 69 Shunted loop 71 Flow guard 115 Immersion heater 117 Additional heater 301 Compressor 302 Brine pump 303 Radiator pump 304 Circulation pump 305 Fan 306 System circulation pump 307 Distribution circulation pump 308 Condenser pump 309 Hot gas pump 310 Reversing valve 311 4 way valve 312 Bypass valve 313 Electronic expansion valve 317 Immersion heater 340 Temperature guard 341 Thermal overload relay 342 Circuit breaker 343 Line circuit breaker 344 Alarm relay 345 Contactor 350 Soft start 351 Capacitor 353 Drip tray heater 354 Compressor Heater 355 Drip tray heater cable 362 Shunt valve control Number/Note Description 363 Reversing valve hot-water 364 Shunt valve hot-water 365 Supply line sensor 366 Return line sensor 367 System shunt 368 Distribution circuit shunt 369 Pool heating valve 370 2nd distribution circuit pump 371 Auxiliary heating Oil/El 372 Auxiliary top heating 373 Distribution circuit shunt 2 374 Shunt defroster 375 Brine valve 376 Shunt cooling 403 Operating pressure switch 405 Heating out sensor 406 Room sensor 407 HGW sensor 408 EVU 410 Hot water 411 Heating return sensor 412 Brine out sensor 413 Brine in sensor 414 High pressure switch 415 Low pressure switch 416 Discharge pipe sensor 417 Defrost sensor 418 Refrigerant 1 sensor 419 Refrigerant 2 sensor 420 Pressure transmitter 421 Suction gas sensor 422 Dewpoint sensor 423 Sensor pool 424 Sensor cooling 425 Sensor buffer tank 426 Sensor system supply line 427 Sensor distribution circuit 1 428 Sensor distribution circuit 2 451 Control unit 452 I/O controller 453 Display 4 VWIFB102 Danfoss Heating Solutions

Number/Note Description 454 Electronic expansion valve controller 455 Indoor hub controller 456 Current limiter 457 WM-HPC Control module 458 HPC-RM Relay module 459 HPC-EM Expansion module 460 HPC-CM Cooling module 461 HPC-OP Operator panel * Note 1 Strapped at delivery * Note 2 blue * Note 2 brown * Note 2 grey * Note 2 green * Note 2 yellow * Note 2 violet * Note 2 pink * Note 2 red * Note 2 black * Note 2 white * Note 3 Can be connected to 230V single phase if auxiliary heater is disconnected. * Note 4 When connected to 230V single phase straps to auxiliary heater shall be removed. * Note 5 Remove jumper when using separate supply of control circuit Number/Note Description * Note 6 Remove jumper when using flowguard * Note 7 Overload relay trip/tripped out * Note 8 Alarm * Note 9 Speed control * Note 10 Please make sure that all supply lines are disconnected before attending any work to internal electrical parts! * Note 11 Fan overload relay * Note 12 To indoor unit * Note 13 To slave unit * Note 14 To electronic expansion unit * Note 15 Immersion heater or external auxiliary heater * Note 16 Potential free contact * Note 17 To outdoor unit * Note 18 To expansion Unit * Note 19 Communication * Note 20 Passive cooling Brine circuit * Note 21 Passive cooling Radiator circuit * Note 22 Combined heat source system * Note 23 Passive cooling * Note 24 Remove jumper when EVU * Note 25 EVU constant power supply * Note 26 Remove jumper if EVU is supplied separately * Note 27 Remove jumper when flowguard or pressure switch Brine is used Danfoss Heating Solutions VWIFB102 5

2 20-26kW 400V 3N 2.1 20-26kW 400V 3N 6 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 7

8 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 9

10 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 11

12 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 13

3 35-42kW 400V 3N 3.1 35-42kW 400V 3N 14 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 15

16 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 17

18 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 19

20 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 21

22 VWIFB102 Danfoss Heating Solutions

Danfoss Heating Solutions VWIFB102 23

Danfoss Heat Pumps Box 950 671 29 ARVIKA Phone +46 570 81300 E-mail: dhpinfo@danfoss.com Internet: www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved. VWIFB102 Produced by Danfoss Heating Solutions 2013