Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 600-800REOZM 600-800REOZMB Weather Standard Features Critical silencer, flexible exhaust connector, and rain cap. Lift base or tank-mounted, steel or aluminum construction with hinged and removable doors. Aluminum enclosures recommended for high humidity and/or high salt/coastal regions. Fade-, scratch-, and corrosion-resistant Kohler cream beige powder-baked finish. Lockable, flush-mounted door latches. Air inlet louvers and damper reduce rain and snow entry. High wind bracing, 241 kph (150 mph). Weather Sound Sound Standard Features Includes all of the weather enclosure features with the substitution of an internal-mounted exhaust silencer and the addition of acoustic insulation material. Vertical air inlet and outlet hoods with 90 degree angles to redirect air and reduce noise. Acoustic insulation that meets UL 94 HF1 flammability classification. Sound attenuated enclosure that offers an average of 80 db(a) sound level at 7 m (23 ft.) using 51 mm (2 in.) of acoustic insulation, acoustic-lined air inlet hoods, and acoustic-lined air discharge hood. Subbase Features The above-ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). Both the inner and outer UL-listed tanks have emergency relief vents. Flexible fuel lines are provided with subbase fuel tank selection. The containment tank s double-wall construction protects against fuel leaks or ruptures. The inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel if the inner tank leaks or ruptures. G6-97 4/08c Page 1
Weather Fixed air flow inlet grille Critical silencer with tailpipe and rain cap Air inlet louvers Automatic door holders provide positive door positions during wind gusts Shown with fill/ spill containment option Fade-, scratch-, and corrosion-resistant powder-baked finish ADV-7431A- Hinged and removable doors for ease of servicing Lockable, flushmounted door latches prevent tampering Oil drain and radiator drains Rodent guards and skid end caps prevent unwanted animal entry Horizontal air discharge through a removable air outlet grille ships assembled on subbase fuel tank or lifting base. Note: 600REOZMB shown, other models are similar. Weather Features Available in steel (14 gauge) or aluminum (2 mm [0.08 in.]) formed panel, solid construction. Preassembled package offering corrosion resistant (aluminum), dent resilient structure mounting directly to lift base or fuel tank. Powder-baked paint. Superior finish, durability, and appearance. External critical exhaust silencer. Offers maximum component life, operator safety, and includes rain shield and cap. Cooling/Combustion Air Intake Weather protective designs using fixed air inlet louvers. Sized for maximum cooling airflow. Cooling Air Discharge Weather protective design featuring horizontal air discharge. Exhausts air through a removable punched air outlet grille. Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. G6-97 4/08c Page 2
Sound Automatic door holders provide positive door positions during wind gusts Fade-, scratch-, and corrosion-resistant powder-baked finish Enclosed insulated exhaust silencer for improved safety and noise reduction Vertical outlet hoods with 90 angles to redirect air and reduce noise Shown with fill/ spill containment option Openings at generator and radiator ends supply ample cooling air flow ADV-7431B- Hinged and removable doors for ease of servicing Lockable, flushmounted door latches prevent tampering Acoustic insulation repels moisture absorption Oil and radiator drains Acoustic insulation meeting UL 94 HF1 flammability classification Rodent guards and skid end caps prevent unwanted animal entry ships assembled on subbase fuel tank or lifting base. Note: 600REOZMB shown, other models are similar. Sound Features Available in steel (14 gauge) or aluminum (2 mm [0.08 in.]) formed panel, solid construction. Preassembled package offering corrosion resistant (aluminum), dent resilient structure mounting directly to lift base or fuel tank. Powder-baked paint. Superior finish, durability, and appearance. Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design. Internal critical exhaust silencer offering maximum component life and operator safety. Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery. Cooling/combustion air intake. Attenuated models offering 90 vertical air inlet and gravity outlet 90 end hoods. The 80 db(a) models include acoustic insulation lining with urethane film. Cooling air discharge. Attenuated models offering 90 vertical air outlet hoods. Redirects cooling air up and above enclosures to reduce noise ambient; 80 db(a) models include acoustic insulation with urethane film. Attenuated design. Acoustic insulation UL 94 HF1 listed for flame resistance; 80 db(a) design offering 51 mm (2 in.) mechanically restrained acoustic insulation in enclosure only. G6-97 4/08c Page 3
Weather and Sound Options Distribution panel heater Thermostat for ventilation fan DC light (qty. 4) Incandescent light (qty. 4) Ventilation fan ADV-7431C- Relay for motorized dampers Battery charger TImer for DC lights 3-way switch with GFCI Panic bars Gravity air outlet louvers Note: 600REOZMB shown, other models are similar. Basic Electrical Package (BEP) Distribution Panel/Load Center. Prewired AC power distribution of all factory-installed features including block heater, two GFCI-protected internal 120-volt service receptacles, internal lighting, and commercial grade wall switch. The load center powered by building source power and protected by a main circuit breaker, rated for 100 amps with capacity and circuit positions for future expansion. AC power distribution installed in accordance with NEC and all wiring within EMT thin wall conduit. Four incandescent or fluorescent lights located within UL-listed fixtures designed for wet locations. BEP available with single-phase load center 120/240 VAC. BEP available with three-phase load center 120/208/ 240 VAC. Heater Heater, 5 kw Ceiling Mounted. Electrical utility heater prewired to load center internal to enclosure. Rated at 17100 Btu includes adjustable louvers offering down flow and horizontal air tuning, built-in thermostat with automatic fan delay controls. Heater available in single phase at 240 VAC. Heater available in three phase at 208 or 240 VAC. DC Light Package DC Light Package (DLP). Prewired DC light package offering an economical alternative light source within the enclosure, as a complement to the BEP or a source of light when AC power is not available. Battery drain limited with fuse protection and controlled through a 0--60 minute, spring-wound, no-hold timer. Miscellaneous Package Options Battery Charger, Mounted. Mounting, prewiring of DC output and AC input when optional BEP is selected. Battery charger located internal of the enclosure and accessible through an access door. Block Heater, Junction Box. Factory-supplied block heater prewired to a junction box providing a convenient location for the customer wiring of the block heater. Heater available in single phase at 240 VAC. Heater available in three phase at 208 or 240 VAC. Design Options Aluminum Steel Panic Bar for each latching door. Provides additional safety for individuals working on the generator set while in the enclosure. Motorized Variable Damper and Ventilation Motorized Air Inlets Aluminum construction Galvanized steel construction (available on sound enclosure only) Motorized Air Outlets (Aluminum construction) Ventilation Fan, 22.6 cm/min. (800 cfm) Wall Mount. Direct drive 3-blade 305 mm (12 in.) aluminum propeller fan with automatic shutters, driven by a totally enclosed air-over motor housed within a corrosion-resistant housing. Remote thermostatically controlled over a temperature range of 27 C to 54 C (80 F to 130 F). All components are prewired and installed. Gravity Air Outlet Louver. Louvers closed when unit is not running. After the unit starts, the forced cooling air opens the outlet louvers. G6-97 4/08c Page 4
Subbase Fuel leak detection switch Electrical stub-up area open to bottom Fuel inlet from supply pump (with user-supplied day tank) Overflow to main tank (with user-supplied day tank Low fuel level switch Additional fitting for optional accessory Emergency inner tank relief vent Fuel fill with lockable cap and 203 mm (8 in.) riser Fuel level gauge Basin drain Removable engine supply dip tube Removable fuel return dip tube Normal vent Emergency outer tank relief vent Note: 600REOZM shown, other models are similar. GM60194- Standard Subbase Features Extended operation. Usable tank capacity offers full load standby operation of up to 72 hours. UL listed. Secondary containment generator set base tank meeting UL 142 tank requirements. NFPA compliant. Designed to comply with the installation standards of NFPA 30 and NFPA 37. Integral external lift lugs. Enables crane with spreader-bar lifting of the complete package (empty tank, mounted generator set, and enclosure) to ensure safety. Emergency pressure relief vents. Meets UL requirements; ensures adequate venting of inner and outer tank under extreme pressure and/or emergency conditions. Normal vent with cap. Vent is raised above lockable fuel fill. Low fuel level switch. Annunciates a 50% low fuel level condition at generator set control. Leak detection switch. Annunciates a contained primary tank fuel leak condition at generator set control. Electrical stub-up. 19 L (5 gal.) Fill/Spill Containment. Above ground fill/spill container for fuel overfill spills during fill-up. External mount or internal mount. Options G6-97 4/08c Page 5
KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-565-3381, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 and Subbase Specifications Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz w/full Load Weather and Subbase Max. Dimensions, mm (in.) Width (with optional fill/spill Length containment) Height With Steel Weight, kg (lb.) With Aluminum Height, mm (in.) 600REOZMB Lifting Base 0 5050 (198.8) 2350 (92.5) 3759 (148.0) 8137 (18015) 7534 (16690) 0 2309 (610) 12 4064 (160.0) 10137 (22427)* 9534 (21102)* 305 (12) 4630 (1223) 24 5127 (201.9) 4369 (172.0) 10474 (23167)* 9871 (21842)* 610 (24) 6965 (1840) 36 2691 (105.9) 4597 (181.0) 10727 (23725)* 10124 (22400)* 838 (33) 9282 (2445) 48 5969 (235.0) 11338 (25090)* 10735 (23765)* 4673 (184.0) 13889 (3669) 72 8509 (335.0) 12427 (27475)* 11824 (26150)* 914 (36) 750/800REOZMB Lifting Base 0 2500 (98.4) 3871 (152.4) 9247 (20375) 8633 (19025) 0 3070 (811) 12 4201 (165.4) 11754 (25903)* 11140 (24553)* 330 (13) 5666 (223.0) 6124 (1618) 24 4481 (176.4) 12204 (26895)* 11590 (25545)* 610 (24) 9206 (2432) 36 2841 (111.8) 12490 (27524)* 11876 (26174)* 12249 (3236) 48 7128 (280.6) 4785 (188.4) 13331 (29379)* 12717 (28029)* 914 (36) 18408 (4863) 72 10253 (403.6) 15059 (32747)* 14445 (31397)* Sound Pressure at 7 m (23 ft.), db(a) Capacity, L (gal.) Est. Fuel Supply Hours at 60 Hz w/full Load Length Sound and Subbase Max. Dimensions, mm (in.) Weight, kg (lb.) Width (with optional fill/spill containment) Height With Steel With Aluminum Height, mm (in.) 600REOZMB Lifting Base 0 2350 (92.5) 3329 (131.1) 8516 (18850) 7675 (17000) 0 2309 (610) 12 3634 (143.1) 10516 (23262)* 9675 (21412)* 305 (12) 4630 (1223) 24 8439 (332.2) 3939 (155.1) 10853 (24002)* 10012 (22152)* 610 (24) 6965 (1840) 36 2691 (105.9) 4167 (164.1) 11106 (24560)* 10265 (22710)* 838 (33) 9282 (2445) 48 4243 (167.1) 11717 (25925)* 10876 (24075)* 13889 (3669) 72 10568 (416.1) 4243 (167.1) 12806 (28310)* 11965 (26460)* 914 (36) 750/800REOZMB Lifting Base 0 2500 (98.4) 3481 (137) 9793 (21589) 8872 (19559) 0 3070 (811) 12 3811 (150) 12300 (27117)* 11379 (25087)* 330 (13) 6124 (1618) 24 9954 (391.8) 4091 (161) 12750 (28109)* 11829 (26079)* 610 (24) 9206 (2432) 36 2841 (111.8) 13036 (28738)* 12115 (26708)* 12249 (3236) 48 4395 (173) 13877 (30593)* 12956 (28563)* 914 (36) 18408 (4863) 72 12748 (501.9) 15605 (33961)* 14684 (31931)* Sound Pressure at 7 m (23 ft.), db(a) 80 80 * Weight includes the generator set (wet), enclosure, silencer, and tank (no fuel). NOTE: The REOZMB data is shown, refer to the respective ADV drawings for details. Refer to the respective ADV drawings for all specifications relating to the REOZM models. DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler generator set distributor for availability. 2008 by Kohler Co. All rights reserved. G6-97 4/08c Page 6