Trees, powerlines and your property



Similar documents
Trees and powerlines. Office of the Technical Regulator. sa.gov.au/energysafe

Trees and powerlines. Office of the Technical Regulator. Web: sa.gov.au/energysafe Phone:

CUSTOMER CONNECTION GUIDE

Tree Management Policy

SA Power Networks Protocol for vegetation management near powerlines

Promoting Tree Health and Electric Safety. Important Numbers

Electrical Safety Tips. Help us keep you safe

Electric Line Clearance Management Plan

TREE CUTTING & TRIMMING INFORMATION As of

Living with Electricity Easements

Guide To Trees And Power Lines

Public Utility District #1 of Jefferson County Vegetation Clearance Policy And Specifications

A GUIDE TO PLANTING AND MANAGING TREES NEAR POWERLINES

Vegetation Management Frequently Asked Questions

Tree Work on District of West Vancouver Property

Q. Why does OG&E clear vegetation away from power lines? A. Trees that grow into power lines can cause problems in multiple ways:

Electronic Communication. 1/2. Applicant s And Agent s Names And Addresses. 3. Tree Location. 4. Tree Ownership

Energex Customer Charter. For residential and small business customers

Application for Tree Works: Works to Trees Subject to a Tree Preservation Order (TPO)

Distribution Substation Manual (DSM) Section I - Introduction

Storm Restoration. Bill Smeaton Distribution Superintendent Provincial Lines

Chapter 162 SHADE TREE COMMISSION

Understanding Line Clearing Efforts. Improving service reliability and promoting the health of your trees.

Vegetation Management. for Distribution Lines

Trimming Trees Near Electric Lines. Understanding Niagara Mohawk s Role and Responsibilities

Planning for Bushfire Risk Mitigation General Code

Tree Trimming Practices. For transmission and distribution power lines. TREE TRIMMING PRACTICES h 1

Street and Reserve Trees Policy

Chapter 29 VEGETATION* ARTICLE I. IN GENERAL

OWNER BUILDER AS AN WHAT ARE MY RESPONSIBILITIES UNDER THE DEVELOPMENT ACT 1993

Indiana Arborist Association Annual Conference January 2013 TREES AND THE LAW IN INDIANA

Tree Management Guidelines

Service & Installation Rules 2014

High Voltage. Hazards

Building Report & Consent

Overhead Power Line Safety for Contractors

3. This writ was filed for the Plaintiff by Mr Brendan Pendergast of Maddens Lawyers, Warrnambool. 7 Vanessa Drive MICKLEHAM Victoria 3064

Avoiding Tree & Utility Conflicts

Trees and Reliable Electric Service. Answers to Questions About Tree Pruning and Electric Power. We re connected to you by more than power lines.

Indicative costs for replacing SWER lines

KUB Tree Pruning: A Customer Guide

Customer Installation Safety Plan. March 2015

BUSHFIRE MITIGATION STRATEGY PLAN

Transmission Business Electrical Incident & Safety Performance Reporting Guide

ALCOA OF AUSTRALIA LIMITED BUSHFIRE MITIGATION AND LINE CLEARANCE PLANS 2013/2014

APPENDIX "F' TREE REMOVAL F-1

The Electrical Safety Regulation (pre and post 1 January 2014)

AVOIDANCE OF ELECTRICAL HAZARDS WHEN WORKING NEAR OVERHEAD ELECTRIC LINES

South East Region Leakage Code of Practice. Affinity Water Limited CODE OF PRACTICE ON LEAKAGE

CLP s Integrated Vegetation Management (IVM) Program. Practical Arboriculture. Training Development and Challenges

CHAPTER 13 NATURAL RESOURCES ARTICLE III. TREES

Considering UNDERGROUND. tampaelectric.com

ARTICLE 167 Shade Tree Commission, Shade Trees

FENCING LAW IN VICTORIA: WHAT ARE MY RESPONSIBILITIES?

Distribution Business Electrical Safety Performance Reporting Guidelines

Transmission/Distribution Vegetation Management Program. Flathead Electric Cooperative,Inc. Powerful Solutions. for our communities

Hendrix Spacer Cable

Service level agreement

BUILDING OR RENOVATING

WORKING IN THE ELECTRIFIED AREA

MOUNT BARKER (DC) DEVELOPMENT PLAN

Does your new building

Proper Pruning For Tree Health and Defensible Space

Standard terms and conditions

Guidance Notes on Tree Pruning

November General Notes. Tree Protection. Tree Protection and New Development Guidance Note

Rural dwellings including bed and breakfast accommodation

SAFETY PERFORMANCE REPORT ON VICTORIAN ELECTRICITY NETWORKS 2014

Everything you should know about smart meters

Complete Solar Photovoltaics Steven Magee. Health and Safety

2002 No ELECTRICITY. The Electricity Safety, Quality and Continuity Regulations 2002

Essential Water. Customer Charter

CAREER NAVIGATOR Worksheet

CITY OF ELBERTON, GEORGIA REQUEST FOR PROPOSAL

Electrical safety rules

Planning requirements for heliports and helicopter landing sites

Treasure Valley Electric Plan - Community Advisory Committee

Practice Note

Review of neighbourly relations. Discussion paper. > Trees

City of Alcoa Electric Department Tree Trimming Policy

Guide to Subdivision and Land Development

Tree Management Policy

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

TransGrid Pesticide Use Notification Plan For Community Consultation

Transcription:

Your safety and responsibility Trees, powerlines and your property

Tree clearing Victoria has well earned the reputation as the Garden State. It s in everyone s interest to help manage the growth and health of our trees. Trees growing too close to powerlines can cause fires, blackouts and power surges. They also present a safety risk to people. The Electricity Safety (Electric Line Clearance) Regulations 2010 set out the minimum clearances required between powerlines and trees. It also outlines the division of responsibilities between councils, power companies and residents in relation to trees and powerlines. Legislation Legislation that underpins the information contained within this brochure include: Electricity Safety Act 1998 Electricity Safety (Electric Line Clearance) Regulations 2010, that incorporates the Code of Practice for Electric Line Clearance Electricity Safety (Installation) Regulations 2009. These publications can be accessed via the Victorian Law Today section at: http://www.legislation.vic.gov.au. About United Energy United Energy (UE) is licensed by the Victorian Government to distribute electricity across Melbourne s south-eastern suburbs and the Mornington Peninsula. We serve some 640,000 customers and own and manage more than 210,000 poles along with about 13,000 kilometres of wires. We are proud to be your local electricity distributor.

Trees in your street In urban areas, local councils generally have the responsibility for maintaining vegetation that interfere with powerlines on road reserves. UE is responsible for trees on road reserves in rural areas within its distribution area. Our commitment to you We will give at least 14 days notification when trees are to be pruned (except in the case of emergencies) Within this time frame we will provide an opportunity for consultation to address any concerns with the vegetation maintenance program. Planting wisely It is recommended that only appropriate tree species be planted near powerlines. For more information on trees that are deemed safe to plant near powerlines, contact our Customer Service Desk on 1300 131 689. Alternatively, visit our website at www.ue.com.au, where our tree planting guide is available to be downloaded. Appearance of the trees Vegetation must be kept well clear of powerlines at all times. It is not always possible to achieve an aesthetically pleasing result from tree pruning around powerlines due to: the type of tree that is planted the position of the tree. It may have either been planted too close to the lines, or even planted directly underneath poor quality of previous maintenance. In some instances, large amounts of the tree may be removed if the tree has not been maintained to appropriate standards in the past. We only use vegetation contractors who are trained to prune trees using arboriculturally sound methods. 1

Trees on your property must be kept clear of powerlines You are responsible for the cutting of trees on your property that may interfere with your own electric service line or private electric line, or a private electric line on an adjoining property Trees near other electric lines that cross your boundary or trees within your property near the electric lines in the street are the responsibility of UE (refer to the diagrams A and B which depict a number of common situations) For safety reasons it is recommended that cutting of trees be done before trees grow to within one metre of an insulated electric service line and two metres of a bare wire electric service line If the trees are closer to these electric lines than the clearances above, or where cutting may cause branches to fall onto electric lines, do not cut them yourself as this may pose a risk to both yourself and your property. In such cases cutting should be done by persons trained to work in the vicinity of electric lines Legislation authorises electricity distribution companies to enter your property to inspect and to maintain electric lines. Safety near powerlines Do Not: Fell a tree within two metres of electric lines Come within one metre of an insulated electric service line Come within two metres of bare electric lines Prune near high voltage electric lines Do: Use qualified vegetation contractors or Registered Electrical Contractors (RECs) Ask United Energy for advice on 1300 131 689 2

Diagram A: Electricity supply from powerlines in the street UE responsibility owner/ occupier service line 2 UE responsibility owner/ occupier private electric line 1, 3 service line 2 Council in most urban areas distribution company in rural areas Diagram B: Powerlines on rural properties powerline including single high voltage lines UE responsibility Land A shed owner/occupier pole UE responsibility private electric line 3 pole Land B owner/occupier (Land B) service line 2 substation 1 This situation is more common in rural areas. 2 For service lines, a minimum of 600mm is required at all times. 3 For private electric lines a minimum of 600mm is required for insulated line and 1.5m for uninsulated lines at all times. 3

Pruning Pruning trees to ensure they are clear of powerlines is essential. The best way to prevent fire and supply interruptions is to remove inappropriate trees. UE prunes trees on a two year cycle. This requires trees to be pruned to beyond the minimum safety clearance to allow for vegetation regrowth as required by the regulations. Once the minimum safety clearance, plus an allowance for regrowth is determined for each branch, it is then trimmed at the nearest collar (or growth point) outside the clearance zone (refer to diagrams C and D). This is a requirement under Australian Standards AS4373. This protects trees from infection or disease and reduces the development of weakly attached growth that can result from trimming trees mid-branch (see below). Appearance of the trees after pruning Limit of clearance required (safety clearance and regrowth allowance) powerline Growth points where branch would be pruned. 4

Diagram C: Pruning in low bushfire risk areas Hazard space Sound limbs may grow over the clearance space for powerlines up to 22kV. Trees shall not be removed without prior consultation (except in emergency situations). Regrowth space 2 years x annual regrowth (2 years = Vegetation Management Cycle) Clearance space Free of vegetation at all times 2m (greater than 1kV, less than 66kV) 2m powerlines 1.5m (upto 1kV) To minimise pruning only species with suitable growth habits should be planted near or under powerlines. Diagram D: Pruning in hazardous bushfire risk areas Hazard space Trees shall not be removed without prior consultation (except in emergency situations). Regrowth space 2 years x annual regrowth (2 years = Vegetation Management Cycle) Clearance space Free of vegetation at all times 2m (greater than 1kV, less than 66kV) 2m powerlines 1.5m (upto 1kV) Unsuitable species on your property may be removed but only with prior appropriate notification. Only species with suitable growth habits shall be planted near or under powerlines or be allowed to remain. 5

Contact us Customer Service Desk Monday to Friday 8am 6pm 1300 131 689 Emergency/Faults 24 hours 132 099 www.ue.com.au This brochure is correct as at May 2012.