RADIATION SAFETY STANDARD



Similar documents
SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Personal Dosimetry in Dental Radiology

HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)

Regulatory Guide. Radiation Safety in Industrial Radiography (FANR-RG-019) Version 0

Safety and Radiation Protection Office Working with X-Ray Equipment

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

portable x-ray survey report

EPA Protocols: Compliance testing of dental X-ray apparatus used for plain radiography

USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

CODE OF PRACTICE & SAFETY GUIDE

Agency for Health Care Administration

Elements of required physical infrastructures: space, schielding, and patient flow..

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

Checklist for submission of application form for Registration

Analytical X-ray Safety Refresh Training. Radiation Safety Officer Department of Environmental Health and Safety

The effects of radiation on the body can be divided into Stochastic (random) effects and deterministic or Non-stochastic effects.

The University of Southern Maine. XRF X-Ray Radiation Protection Program

Radiation Safety Committee College of William and Mary

X-ray Imaging Systems

Order No (1) for 1995 On the Regulation of Practicing The Profession of Radiology (Examination and Treatment)

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

X-ray Radiation Safety Course. James Kane & Rob Deters Office of Radiological Control

PART H RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT. Definitions. As used in this Part, the following definitions apply:

Staff Doses & Practical Radiation Protection in DEXA

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

(Translated Version Jan. 2013)

This section deals with mandatory and optional equipment for your vehicle as well as suggestions for safer road use.

PART 34--LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS

Required RS Training Info

X-ray Imaging Systems

Laser Safety Self-Audit Checklist

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

FIRERAY 2000 Installation Guide

DSM155 Digital LED Light Meter User s Manual DSM155

Understanding Digital Modalities: System Integration and Use

TM Advanced Tracking Technologies, Inc ATTI All rights reserved

LASER-PROTECTION INFORMATION

JB-70 Dental X-Ray System

CONSERVATION AND LIGHTING

Model 70A00-1. GSM Cellular Communications Center

TITLE 32: ENERGY CHAPTER II: ILLINOIS EMERGENCY MANAGEMENT AGENCY SUBCHAPTER b: RADIATION PROTECTION

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Specific local rules for governing the use of the Niton XLt Environmental Analyser (portable XRF): Laboratory

Performance Specification for Pedestrian Facilities at Temporary Standalone Traffic Signals

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Laser Classification. Laser Classes

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

Ell STEERING COLUMN CONTROLS STEERING COLUMN CONTROLS

Operating Manual Color Changing Fountains

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Technical Notes NDT 001 Specific Requirements for Non- Destructive Testing Laboratories

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

igadgitz Bluetooth Audio Transmitter & Receiver (BTT009 / U3442) User Guide

XRS-4 X-RAY SOURCE OPERATOR S MANUAL

Radiation Rule Guide. Veterinary Facilities. Hawaii Administrative Rules, Chapter 11-45, Radiation Control. Hawaii State Department of Health

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

I.7. SOFT TECHNIQUE STILL IN USE IN CHEST RADIOGRAPHY PROS AND CONS

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

Fire Alarm system Installation Guide

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Production of X-rays and Interactions of X-rays with Matter

Bluetooth Stereo Headphone. User Guide. Hive

X-RAY REGULATORY GUIDE

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Video Keyboard Mouse Audio automatic Switch CAS-241, CAS-441, CAS-441-PM

Multi-information Display (see MID )

Standard the the Raising

X-ray Imaging System. X-Ray Circuit. Principles of Imaging Science II (RAD 120) X-ray Imaging System Circuitry

5.8GHz Audio/Video Sender

Guidelines for Excavations

Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project

TO INVESTIGATE THE PROTECTION OF SUNCREAMS AGAINST UV RAYS

XRS-3 X-RAY SOURCE OPERATOR S MANUAL

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Introduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?

X-ray Safety Manual 2013

The Ionising Radiations Regulations 1999 (IRR'99): Guidance Booklet

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

Occupational Health and Safety Amendment (Residual Current Devices) Regulation 2011

PART 1 PRODUCT (GENERAL)...1.

Insulation Resistance Testing of Low Voltage Cables in the Field

AIRCRAFT WARNING LIGHTS

Transcription:

Radiation Safety Act 1999 RADIATION SAFETY STANDARD NM004:2010 Standard for radiation apparatus used to carry out industrial radiography

Preface Under section 17 of the Radiation Safety Act 1999, a possession licensee who, under a licence, possesses an ionising radiation apparatus to carry out a radiation practice, must ensure that the apparatus is not used for this purpose, unless the radiation apparatus complies with the relevant standard. This radiation safety standard NM004:2010 Standard for radiation apparatus used to carry out industrial radiography is made under section 16 of the Radiation Safety Act 1999. This standard sets the minimum safety criteria for radiation apparatus used to carry out industrial radiography. Compliance with this standard will assist in ensuring that public and occupational exposure to radiation is minimised. Queensland Health has prepared this standard based on information derived from reputable sources such as the National Health and Medical Research Council. The standard will be reviewed periodically to re-evaluate its currency and its appropriateness as the standard for radiation apparatus used for industrial radiography. By ensuring compliance with this radiation safety standard, the standard of radiation apparatus used for industrial radiography in Queensland will be significantly enhanced. I, Paul Lucas, Deputy Premier and Minister for Health, pursuant to section 16(1) of the Radiation Safety Act 1999, make the radiation safety standard NM004:2010 Standard for radiation apparatus used to carry out industrial radiography, for the purposes of the Act. SIGNED PAUL LUCAS MP Deputy Premier Minister for Health 19 / 08 / 2010

Contents Section 1 General 1.1 Scope 1.2 Expiry 1.3 Documents 1.4 Definitions Section 2 Standard - Industrial radiography radiation apparatus Appendix A Documents 1 of 6

Standard for radiation apparatus used to carry out industrial radiography Section 1 General 1.1 Scope This radiation safety standard sets out the minimum requirements for radiation apparatus that is used to carry out industrial radiography. 1.2 Expiry This radiation safety standard expires on 1 September 2020. 1.3 Documents Documents that may provide a useful reference are listed in Appendix A. 1.4 Definitions In this standard - "industrial radiography" means the use of the penetrating power of X-rays to obtain information non-destructively on the internal state of objects and materials. kvp means the potential difference applied to an X-ray tube between the anode and the cathode which is expressed by its peak value in kilovolts (kvp). open site means a site at which, due to operational requirements, shielding is not provided, a clearly marked boundary is set up and strict control of access and occupancy is observed. radiation dose rate means the amount of energy from radiation absorbed by a person or thing exposed to the radiation during a particular time. X-ray crawler means industrial radiography radiation apparatus designed to travel automatically or by remote control through pipes to radiograph pipeline welds through the pipe wall. 2 of 6

Section 2 - Standard Industrial radiography radiation apparatus Test Compliance Test Criteria for Passing the Test Radiation dose rate 1 Radiation dose rate The radiation dose rate 1 metre from the housing must not exceed 5000μSv in one hour under conditions of continuous operation at maximum energy and output. 2 Radiation dose rate fluoroscopy Radiation apparatus that is used for direct-viewing fluoroscopy must be shielded such that at no time during exposure can the radiation dose rate at any accessible position exceed 25μSv in one hour. 3 kvp and ma indication on control panel The control panel must be equipped with a device or devices indicating the X-ray beam energy and output in terms of the X- ray tube potential difference (kvp) and current (ma) or electron energy and radiation dose rate, as appropriate. For radiation apparatus that is used at an open site, the values indicated must be clearly legible in bright sunlight. Warning signs 4 Control panel indicator light A red or amber indicator light must: (a) be provided on the control panel; and (b) automatically illuminate when the X-ray tube is energised. 5 Lamp on X-ray tube housing A red or amber indicator lamp must: (a) be provided on the X-ray tube housing; and (b) automatically illuminate when the X-ray tube is energised; and (c) be visible from a distance of at least 10 metres. 6 Indicator lamps fail-safe If an indicator lamp on the X-ray tube housing or on the control panel fails: (a) the X-ray tube must not be able to be energised; and (b) replacement of the lamp must not automatically reenergise the X-ray tube. 3 of 6

Test Compliance Test Criteria for Passing the Test Switches 7 Key switch on control panel A key switch must be fitted to the X-ray control panel. The key must be removable only when the switch is in the "off" position. 8 Function of key switch clearly marked The function of the key switch and its on/off positions must be clearly marked on the control panel. 9 X-ray control switch An X-ray on/off control switch must be physically separate from the key switch. 10 Function of X-ray control switch The function of the X-ray on/off control switch and its on and off positions must be clearly marked on the control panel. Termination of X-rays 11 Termination of X-rays A device must be provided which will terminate the production of X-rays after a preset interval not exceeding 30 minutes or as otherwise approved for the apparatus by the chief executive, in writing. Additional requirements for radiation apparatus used at an open site 12 Control panel fitted with remote flashing light If the radiation apparatus is used at an open site, the control panel must be fitted with a means of connecting a remote flashing light or a series of remote flashing lights which can be used to define a boundary or provide a visible warning when the equipment is energised. 13 Length of cable If the radiation apparatus is used at an open site, the length of cable connecting the control panel to the X-ray tube must not be less than: 7 metres for equipment rated at less than 100kVp 10 metres for equipment rated at less than 200kVp 15 metres for equipment rated at less than 250kVp 20 metres for equipment rated at 250kVp or greater. 4 of 6

Test Compliance Test Criteria for Passing the Test Additional requirements for X-ray crawler equipment 14 Accidental exposure An X-ray crawler, for which exposures are initiated by remote control or by an automatic device such as a trip wheel, must have a safety device fitted to it which prevents the remote control or the automatic device from initiating an unintentional exposure. 15 Power off if malfunction occurs An X-ray crawler must incorporate a safety device which disconnects power from the propulsion unit to the radiation apparatus in the event of a malfunction during operation. 5 of 6

Appendix A Documents National Health and Medical Research Council. Code of practice for the safe use of industrial radiography equipment 1989. NHMRC Publication No. 31, 1989. 6 of 6