Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual



Similar documents
ACS-30-EU-EMDR-10-MOD

Water Leak Detection System

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

THERMAL MANAGEMENT SOLUTIONS

Operation and Installation Manual

LIEBERT VNSA Installation Sheet

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

TSn SERIES Surge Protective Device

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

TMS TANK MANAGEMENT SYSTEM

Owner's/Installation Manual

Advanced Heat-Tracing Control System

SECTION LOW VOLTAGE LIGHTING CONTROLS

Advantium 2 Plus Alarm

HM-W536 Install Guide

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

INSTALLATION & SERVICE MANUAL. Display Panel

HERZ-Thermal Actuators

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Residential Gateway (RG) Battery Backup REV B

CO2 Alarm. Operation. Application

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

INSTALLATION INSTRUCTIONS

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

BroadBand PowerShield. User Manual

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Machine Safety Switches

INSTALLER S & OWNER S MANUAL

Single Station Remote Alarm

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Split units TH with hermetic compressors

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Fire Pump Controllers Remote Alarm Panels

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

, User s Manual

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

HMI display Installation Guide

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

InHome Water Leak Detection Package

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Solid State Timers Type F

2-Pair HDSL1 Adtran Fiber Optic Link System

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

MCR1900 Media Converter 19-Slot Chassis

CQM1-SF200/CS1W-SF200

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

ASCO SERIES 185 Power Transfer Switches

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1D for BSX, RSX, VSX SCTK-2D for KSX, HTSX SCTK-3D for HPT, FP

Comfort Control Relay Panel (CCRP)

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

8146/5 Series Breaker Panelboards

Original instructions Tina 3A/Aps Adaptor unit

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Radiant Temperature Sensor TY7321

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

Model SRMD Setra Remote Monitoring Display

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Single Phase Soft Starter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Five9NS R2100RS Rack Mount Server. Installation Manual

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

Back-UPS Pro 1300/1500 Installation and Operation

Oil and Coolant Circulating Heating System. Model - OCSM

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

For Models #6-5001, #6-7501, # & #10-12K1

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Transcription:

Freeze Protection Thermostats MODELS SST 2 Part Number 22744 MANUAL We Manage Heat Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239 FAX (574) 233-2152 or (888) 234-4238 http://www.networketi.com/ 22804 11/07 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc.

Model SST 2 2 of 12 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 11/07 22804

Safety Make all electrical connections in compliance with the National Electric Code (NFPA 70) and local electrical code. If you have questions concerning the installation or application, contact Customer Service. Model SST 2 Additional Information More information is regularly made available through our website, www.networketi.com. Please visit us online for datasheets, manuals, white papers, technical articles and more. The most current and up to date version of this and every other manual for our products can be found in Acrobat (pdf) format to view online or to print. This is to assist you in installing and using our products to the best effect possible. If you have any comments about this or any other material from Environmental Technology please contact us. Contacting Environmental Technology For assistance, contact Customer Service. Offi ce hours are 8:00 AM until 5:00 PM ET. Voice: Fax: E-mail: Mail: General (800) 234.4239 (USA and Canada) or (574) 233.1202 (elsewhere) (888) 234.4238 (USA and Canada) or (574) 233.2152 (elsewhere) helpdesk@networketi.com Environmental Technology, Inc. 1850 North Sheridan Street South Bend, IN 46628 Description The C-UL-US listed SST 2 Freeze Protection Thermostat replaces electromechanical thermostats in cost-sensitive applications requiring ground fault equipment protection (GFEP). The SST is classifi ed to UL and CSA safety standards by UL for use in temperature-regulation applications. It is the ideal low-cost thermostat for areas not subject to mechanical abuse. Specifi cations General Area of use Approvals Nonhazardous locations 109R Type 873 Temperature Regulating Equipment Enclosure Protection Cover attachment Entries Material Mounting NEMA 4x Polycarbonate cover, machine screws 1 3/4" entry (bottom right) for NEC Class 2 sensor connections 3 1-1/16" entries (bottom left and left) for supply, load power and (right) NEC Class 2 alarm relay connections Polycarbonate Wall mounted 22804 11/07 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 3 of 12

Model SST 2 Front Panel Interface Status indicator Remote Interface Alarm relay Summary alarms Control Supply voltage Contact type Maximum Ratings SUPPLY (green) power applied SUPPLY (green, fl ashing) bad thermistor HEAT (yellow) call for heat GFEP (red) ground fault condition GFEP (red, fl ashing) failed GFEP test GFEP (red, fl ashing, rapid) GFEP test in progress Isolated SPDT 1 AMP Class 2 contact No Power Ground Fault Condition GFEP function test failure Bad or missing Thermistor 120, 208, 240 or 277 volts, single phase (automatically selected) Two Form A DPST Voltage: 277 VAC Current: 30 amps Temperature Sensor Set point 40 F (4.4 C) Dead band 2 F (1 C) Sensor type Thermistor network Circuit type NEC Class 2 Lead Length Up to 2,000' (610m) using 12 AWG 2-wire jacketed cable Up to 500' (152m) using 18 AWG 2-wire jacketed cable Ground Fault Equipment Protection (GFEP) Set point 30 ma Automatic self test Mode A: Verifi es GFEP function before contactors operate Mode B: Verifi es GFEP function every 24 hours Manual test/reset TEST/RESET switch on front panel Environmental Operating temperature Storage temperature 40 F to 130 F ( 40 C to 55 C) 67 F to 167 F ( 55 C to 75 C) Installation Unpacking Immediately inspect the packing material for damage. Unpack the SST 2, taking care not to damage the packaging material. Save the packaging material until normal operation has been established. If the unit must be returned, take care to ensure that it is repackaged as it was received. Packing List 22744 SST 2 Freeze Protection Thermostat 19272 Temperature Sensor 22804 SST 2 Installation and Operation Manual 4 of 12 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 11/07 22804

Initial Inspection Inspect the SST for shipping damage. If any of the following problems are found contact the Customer Service Department. Contents incomplete or incorrect Internal or external mechanical damage Customer service is available between 8:00 a.m. and 5:00 p.m. ET at (574) 233-1202 or (800) 234-4239. In the event of shipping damage, keep the packing materials for inspection by the carrier. Normally, Environmental Technology, Inc. will repair or replace the SST without waiting for the claims settlement. Model SST 2 Location Housed in a NEMA 4X rated enclosure, the SST freeze protection thermostat can be mounted in either indoor or outdoor environments. The SST was designed to operate over an ambient temperature range of 40 to 136 F ( 40 to 58 C). Using the integral mounting fl anges, the SST is intended to be installed on a fi xed, fl at, vertical surface. The mounting fl anges accommodate 1 /4" (6mm) fasteners. The SST freeze protection thermostat nonmetallic enclosure is furnished with two 3 /4" (21mm) conduit entries. The lower conduit entries provide for line voltage supply branch circuit conductors. The conduit entry at the top-left of the enclosure is for heater load branch circuit conductors. The installed weather-tight fi tting is for the low voltage, NEC Class 2, temperature sensor. The Temperature Sensor may be located up to 2,000' (610m) from the SST. Supply Voltage The SST freeze protection thermostat operates from 120, 208, 240 or 277 VAC at 50/60 Hz. For line supply and load connections, use 10 AWG or larger wires rated for at least 75 C (167 F) at 300 VAC. Contactor Ratings The heater contactor provides two (2) Form A (DPST) defi nite purpose contacts rated for up to 30 amp AC heater loads at voltages at or below 277 VAC. 7 7 /16" (189mm) 4 1 /4" (108mm) 1 1 /16 (27mm) Conduit Entry 1 1 /16 (27mm) Conduit Entry 3 /8" (10mm) Ø Temperature Sensor 1 7/16" (37mm) Figure 1: SST 2 dimensions. See Appendix A. 20' (6m) Sensor Cable, 3/16" (5mm) Ø 22804 11/07 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 5 of 12

Model SST 2 CONNECT LINE 2 (OR NEUTRAL) FROM INCOMING POWER TO BOTH LINE 2 RED AND NEUTRAL/WHITE INSIDE SST2 ENCLOSURE. THIS CONNECTION PROVIDES POWER TO THE CONTROLLER. FOR REMOTE ALARM CONTROL VIA ISOLATED SPOT CLASS 2 CONTACT CONNECT BLACK SENSOR WIRE TO ONE BLUE WIRE IN SST2 ENCLOSURE, AND CONNECT RED SENSOR WIRE TO THE OTHER BLUE WIRE. (PRE-WIRED IN AMBIENT SST2-AMB MODEL) 208/240VAC 50/60 HZ SAFETY GROUND PHASE PHASE CONNECT LINE 2 (OR NEUTRAL) FROM INCOMING POWER TO BOTH LINE 2 RED AND NEUTRAL/WHITE INSIDE SST2 ENCLOSURE. THIS CONNECTION PROVIDES POWER TO THE CONTROLLER. FOR REMOTE ALARM ONLY 120, 277VAC 50/60 HZ SAFETY GROUND NEUTRAL PHASE SAFETY GROUND FOR REMOTE ALARM CONTROL VIA ISOLATED SPOT CLASS 2 CONTACT CONNECT BLACK SENSOR WIRE TO ONE BLUE WIRE IN SST2 ENCLOSURE, AND CONNECT RED SENSOR WIRE TO THE OTHER BLUE WIRE IN AMBIENT SENSING SST2-AMB MODEL, SENSOR IS MOUNTED ON SIDE OF ENCLOSURE AND PRE- WIRED. FOR PIPE SENSING APPLICATIONS INSTALL SENSOR ON OPPOSITE SIDE OF PIPE FROM HEATER CABLE. CABLE CAN BE CUT SHORTER OR EXTENDED UP TO 500' IF REQUIRED. FOR EXTENSION USE 2C/ #18 JACKETED CABLE. 6 of 12 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 11/07 22804

NEC Class 2 Low Voltage Connections All low voltage wiring shall use 18 AWG or greater stranded conductors with thermoplastic insulation rated for at least 75 C (194 F) at 300 VAC. The temperature sensor is supplied with a 20' (6m) 2-wire jacketed cable lead. The temperature sensor lead may be up to 500' (152.4m) using 18 AWG 2-wire jacketed cable, or up to 2,000' (609.6m) using 12 AWG 2-wire jacketed cable. Model SST 2 Temperature Sensor The Temperature Sensor is required for the operation of the SST. The Temperature Sensor connects via wire nuts to the two blue wires in the SST enclosure. It does not matter which sensor wire is connected to which blue wire in the enclosure. The sensor should be located near the heater being controlled and is used to monitor its temperature. Operating Instructions Power On Startup Test When power is applied to the SST 2 freeze protection thermostat, the LED indicator lights in the SST enclosure will cycle for two seconds and then turn off, except for the green SUPPLY indicator, which will remain lit whenever the SST senses supply power. Next, the SST 2 freeze protection thermostat performs a self-test of the ground fault circuitry. This is the same test automatically performed approximately every 24 hours. Failure of the ground fault circuitry self-test will disable the SST; call Customer Service. Operation The SST 2 freeze protection thermostat does not require user attention during normal operation. Status indicator SUPPLY (green) power applied SUPPLY (green, fl ashing) bad thermistor HEAT (yellow) call for heat GFEP (red) ground fault condition GFEP (red, fl ashing) failed GFEP test GFEP (red, fl ashing, rapid) GFEP test in progress GFEP Test To manually verify the operation of the ground fault circuitry, momentarily press the GFEP TEST/RESET switch on the SST. This should not normally be necessary as the SST will test the ground fault circuitry when power is applied to the unit and once approximately every 24 hours as long as power is supplied to the unit. GFEP Reset In the event that a ground fault condition is detected by the SST heaters will be turned off, if on, and heaters will be prevented from further operation until the ground fault condition has been reset. The red GFEP Fault indicator will be continuously on as long as there is power to the SST and a ground fault condition 22804 11/07 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 7 of 12

Model SST 2 remains. The ground fault condition will be persistent and will be remembered by the SST even if the unit loses power. To clear the ground fault condition momentarily press the GFEP TEST/RESET switch on the SST. Maintenance The SST 2 does not require routine maintenance. For technical help, questions or comments concerning this product or any Environmental Technology, Inc. prod ucts contact the Customer Service Department between 8:00am and 5:00pm ET at: Voice: Fax: E-mail: 800.234.4239 (USA and Canada) or 574.233.1202 (elsewhere) 888.234.4238 (USA and Canada) or 574.233.2152 (elsewhere) helpdesk@networketi.com 8 of 12 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 11/07 22804

Appendix A. SST 2 Dimensions. Model SST 2 7 7 /16" (189mm) 4 1 /4" (108mm) 1 1 /16 (27mm) Conduit Entry 1 1 /16 (27mm) Conduit Entry 3 / 8" (10mm) Ø Temperature Sensor 1 7/16" (37mm) 20' (6m) Sensor Cable, 3/16" (5mm) Ø 22804 11/07 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 9 of 12

Model SST 2 Appendix B. SST 2 Wiring Diagram. CONNECT LINE 2 (OR NEUTRAL) FROM INCOMING POWER TO BOTH LINE 2 RED AND NEUTRAL/WHITE INSIDE SST2 ENCLOSURE. THIS CONNECTION PROVIDES POWER TO THE CONTROLLER. FOR REMOTE ALARM CONTROL VIA ISOLATED SPOT CLASS 2 CONTACT CONNECT BLACK SENSOR WIRE TO ONE BLUE WIRE IN SST2 ENCLOSURE, AND CONNECT RED SENSOR WIRE TO THE OTHER BLUE WIRE. (PRE-WIRED IN AMBIENT SST2-AMB MODEL) 10 of 12 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 11/07 22804

Appendix C. SST 2 Wiring. Model SST 2 208/240VAC 50/60 HZ SAFETY GROUND PHASE PHASE CONNECT LINE 2 (OR NEUTRAL) FROM INCOMING POWER TO BOTH LINE 2 RED AND NEUTRAL/WHITE INSIDE SST2 ENCLOSURE. THIS CONNECTION PROVIDES POWER TO THE CONTROLLER. FOR REMOTE ALARM ONLY 120, 277VAC 50/60 HZ SAFETY GROUND NEUTRAL PHASE SAFETY GROUND FOR REMOTE ALARM CONTROL VIA ISOLATED SPOT CLASS 2 CONTACT CONNECT BLACK SENSOR WIRE TO ONE BLUE WIRE IN SST2 ENCLOSURE, AND CONNECT RED SENSOR WIRE TO THE OTHER BLUE WIRE IN AMBIENT SENSING SST2-AMB MODEL, SENSOR IS MOUNTED ON SIDE OF ENCLOSURE AND PRE- WIRED. FOR PIPE SENSING APPLICATIONS INSTALL SENSOR ON OPPOSITE SIDE OF PIPE FROM HEATER CABLE. CABLE CAN BE CUT SHORTER OR EXTENDED UP TO 500' IF REQUIRED. FOR EXTENSION USE 2C/ #18 JACKETED CABLE. 22804 11/07 (800) 234-4239 http://www.networketi.com Environmental Technology, Inc. 11 of 12

Model SST 2 ORDERING INFORMATION Order Number Description 22744 Model SST 2 Freeze Protection Thermostat 19272 Temperature Sensor (included) LIMITED WARRANTY ETI s two year limited warranty covering defects in workmanship and materials applies. Contact Cus tom er Service for complete warranty information. DISCLAIMER Environmental Technology, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents of this publication or the products that it describes, and specifically disclaims any implied warranties of mer chant abil i ty or fitness for any particular purpose. En vi ron men tal Technology, Inc. reserves the right to revise this pub li ca tion, and to make changes and im prove ments to the products described in this publication, with out the ob li ga tion of En vi ron men tal Tech nology, Inc. to notify any person or or ga ni za tion of such revisions, chang es or improvements. The ETI logo, Snow Switch, Floorstat, Tracon, We Manage Heat, APS, RCU, CIT, GIT, SIT are reg is tered trademarks of En vi ron men tal Technology, Inc. Copyright 2006 Environmental Technology, Inc. All rights reserved. 12 of 12 Environmental Technology, Inc. http://www.networketi.com (800) 234-4239 11/07 22804